Loading...
HomeMy WebLinkAboutEngineering�FL #: FL 17022.1 R6 Mate: 12 / 22 / 16 CBUCK Engineering Page rt No.: 5 - 6-5V-S6W-ER 7 Specialty Structural Engineerlinq CBUCK, Inc. Certificate of Authorization #8064 Installation: Installation Method: (Refer to "TABLE A" below and drawings at the end of this evaluation report.) ■ Fastener Spacing: Refer to "TABLE A" Below (attached to the tops of the V's for a total of 3 screws across the width of the panel.) ■ Row Spacing: Refer to "TABLE A" Below (along the length of the panel) ■ Rib Interlock: Lapped ■ 3/16" min. fastener penetration through deck or 5/8" min. embedment into wood plank ■ For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. TABLE "A" ALLOWABLE LOADS METHOD 1: M OD 2: METHOD 3: MET 4: Design Pressure (ASD)*: - 86 PSF - 93.5 PS -101 PSF - 228 PSF Row Spacing: 16 o.c.. 16" o.c. " o. 6" o.c. Fastener Spacing (along rows): 12 o.c. 12" o 12" O.C. " O.C. Fastener Size: #9 #10 #10 #10 *Allowable design pressure(s) for allowable stress design (ASD) with a margin of safety of 2 to 1. Install the 5-V Crimp roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 5th Edition (2014). The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Referenced Data: 1. UL 580-06 & UL 1897-04 — Uplift Test By Architectural Testing, Inc. - West Palm Beach, FL (FBC Organization #TST ID: 1527) Report No.: D5893.01-450-18, Date: 05 / 02./14 Report No.: F3366.01-450-18, Date: 12 / 18 /15 2. TAS 125 — Uplift Test By Architectural Testing, Inc. - West Palm Beach, FL (FBC Organization #TST ID: 1527) Report No.: D5893.02-450-18, Date: 07 / 22 /14 3. Quality Assurance Keystone Certifications, Inc. (FBC Organization ID# QUA 1824) Extreme Metal Fabricators, Inc. Licensee #974 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) —FL #: FL 17022.1 R6 ate: 12 / 22 / 16 CBUCK Engineerinq page Report No.: 6 -1676-5V-S6W-ER Specldlty Structurdl EnglnePrtnq CBUCK, Inc. Certificate of Authorization #8064 Installation Method Extreme Metal Fabricators, LLC. 5-V Crimp (26 Gauge steel) Roof Panel attached to Wood Deck Drawings -00 24" 12" 3/8" TOPTIONAL STRIATIONS Panel Profile Nominal 12" o.c. I Nominal 12" o.c. Fastener #9 x 1-1/2" Min. or #10 X 1-1/2" Min. per Table "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Width Panel Overlap Refer to Table "A" for Spacing Along Panel Length Deck: -15/32" or greater Plywood, or - VVood plank Typical Assembly Profile View (Typical Fastening Pattern Accross Width - Interior) _ GL #: FL 17022.1 R6 gate: 12 / 22 / 16 i CSUCK Engineerin Page Report No.:1 - 76-5V-S6W-ER N Speclalty Structural Engtneering CBUCK, Inc. Certificate of Authorization #8064 Installation Method Extreme Metal Fabricators, LLC. 5-V Crimp (26 Gauge steel) Roof Panel attached to Wood Deck 1 \1y14 11 IJ41QUV1 I -15/32" or greater Plywood, or Thickness 3" ftdrnum - Wood plank Typical Roof Assembly Isometric View (Optional) Rigid Insulation Board per Page 4 of this report TABLE "A" ALLOWABLE LOADS METHOD 1: M OD 2: METHOD 3: METH Design Pressure (ASD)*: - 86 PSF - 93.5 PS -101 PSF - 28 PSF Row Spacing: 16' o.c. 16" o.c. 8" 6" o.c. Fastener Spacing (across panel width): 12" o.c. 12" ox 12" o.c: " o.c. Fastener Size: #9 10 #10 #10 * Allowable design pressure(s) for allowable stress design (ASD) with a margin of safety of 2 to 1.