Loading...
HomeMy WebLinkAboutLaboratory Test ReportMIAM_I - MDADE CONSTRUCTION MATERIALS r•�s. TECHNOLOGIES ACCREDITED LABORATORY TEST REPORT Report for: Woodland Industries Date: July 27, 2009 1520 Kalamazoo Drive Griffin, GA 30224 Attention: Dina Crownover Product Name: No. 15 Manufacturer: Woodland Industries Date Received: June 25, 2009 Source: Woodland Industries PRI Report No.: WII-005-02-02 Dates of Testing: July 1 —July 14, 2009 Subject: The purpose of this project was to test Woodland Industries No.15 asphalt felt underlayment for compliance with the Florida Building Code 2007, Sections 1507.2.3, 1507.5.3, 1507.6.3, 1507.7.3, 1507.9.3, and 1507.8.3: Underlayment using ASTM D 4869-04: Standard Specification forAsphalt-Saturated Organic Felt Undedayment Used in Steep Slope Roofing, Type 1 (#8) and for compliance ASTM D 4869-05fl: Standard Specification for Asphalt - Saturated Organic Felt Underlayment Used in Steep Slope Roofing, Type 1 (#8). Test Methods: The test methods used included those found in ASTM D 4869: Standard Specification for Asphalt -Saturated Organic Felt Underlayment Used in Steep Slope Roofing and including: ASTM D 146: Standard Test Methods for Sampling and Testing Bitumen -Saturated Felts and Woven Fabrics for Roofing and Waterproofing, ASTM D 228: Standard Test Methods for Sampling, Testing, and Analysis of Asphalt Roll Roofing, Cap Sheets, and Shingles Used in Roofing and Waterproofing; ASTM D 1922: Standard Test Method for Propagation Tear Resistance of Plastic Film and Thin Sheeting by Pendulum Method, ASTM D 6136: Standard Test Method for Kerosene Number of Unsaturated (Dry) Felt by the Vacuum Method, ASTM F 1087: Standard Test Method for Linear Dimensional Stability of Gasket Material to Moisture. Sample The sample received from Woodland Industries on June 25, 2009 and was a full factory Description: labeled roll of felt. WII-005-02-02 PRI Accreditations: IAS-ES TL-189; State of Florida TST5878; Metro -Dade 06-1116.02; CRRC The test results, opinions, or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced except in full without the written approval of this laboratory. PRI Construction Materials Technologies, LLC. assumes no responsibility nor makes a performance or warranty statement for this material or products and processes containing this material in connection with this report PRI Conswction Materials Technologies, I.L.C. 6408 Badger Drive Tampa, FL 33610 Tel: 813-6215M Fax: 81M21-5840 e-mail materialslesting a@pricmt.ccm WebSlte: htlp:/Mnvw.pdcmt.com Woodland Industries Laboratory Test Report for No. 15 Felt Page 2 of 3 �l ResU IKS Or I estin : , Property ASTM Test Method• Result ,;,• 5. Materials • Mfg. 5.1 Saturation Uniformity D 4869 Pass Uniform 5.2 Upon tearing D 4869P2SS �'�°°'*�'`� -No lumps or.- forei n sub. 6.0 Physical Requirements g To if4 .il d1 ear, tren 73 F N lr !1 !? { 4 �@ . , C,�.,,,.'.r MD r72 0.45 Min CMD 0 9ti k s 0.45 min "_ I. ^ ' , im ! v Phabl4fy<@73 F,t uI� : � r �. ,,.a, r D „ •, rc t a !rr t * r' r a ,; ,� MDPasxsu'' Pass 0.5" CMD '° 'Pass Pass,0.5" Loss on Heating @ 2217, % D 146 6 max Liquid Water Transmission D 4869 Pass Pass ' r , Bteaktng S�r"engthL MD .30 min , CMD` 161 _' 15 min . � r t jy 'rr-! �, 4� , , iv ! , k„ v j . i i � i ! iti r •: MD Low to high humidity 2.00 max CMD Low to high humidity 2,00 2.00"max Width of roll, in D 146 ` '" 36 '- 36 t 0.7%A t: Area of roll, sq. ft. D 146 n..x_ A 3t8 432 min Net mass, satd. felt, Ib/100 ft2 D 146 3 8 O.min Net mass saturant, Ib/100 ft2 D 146 4.0 4.0 min' Net mass desaturated felt, Ib/100 ft2 D 146 4.0 min ° Saturation by wt., /° D 146 "� 1�09 a� : ,100 min_ _= Moisture at time of manufacture, % D 95 2`0� 2.0 ,max Saturating Efficiency, % by Wt. D 4869 78 ; ,; 75.0 min ` Shall not crack 6.2 Unrollingat 32°F and 140OF D 4869 'PaS.S orbs steariEl cause teari wu ,ram otherdam Note A: Or, as agreed upon by purchaser and seller. WII-005-02-02 PRI Accreditations: IAS-ES TL-189; State of Florida TST5878; Metro -Dade 06-1116.02; CRRC The test results, opinions, or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced except in full without the written approval of this laboratory. PRI Construction Materials Technologies, LLC. assumes no responsibility nor makes a performance or warranty statement for this material or products and processes containing this material in connection with this report PRI Construction Materials Technologies, LLC, 6408 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail materialstesling@pricmLcorn webSlte;,htlpJAvww.pdcmLcom Woodland Industries Laboratory Test Report for No. 15 Felt Page 3 of 3 Statement of Compliance: This product complies with all of the requirements the Florida Building Code 2007, Sections 1507.2.3, 1507.5.3, 1507.6.3, 1507.7.3, 1507.9.3, and 1507.8.3: underlayment using ASTM D 4869-04: Standard Specification forAsphalt-Saturated Organic Felt Underlayment Used in Steep Slope Roofing, Type 1(#8). This product also complies with all of the requirements of ASTM D 4869-05`': Standard Specification forAsphalt- Saturated Organic Felt Underlayment Used in Steep Slope Roofing, Type 1(#8). Limitations: Not for use in Dade County. Signed: CiV���G�k� :� A Donald C. P6Afolio President Date: / z d Signed: Duc T. Nguyb Florida Registered Prc5fessional Engineer R. E. Number: 65034 Date: ---�4 i WII-005-02-02 PRI Accreditations: IAS-ES TL-189; State of FloridaTST5878; Metro -Dade 06-1116.02; CRRC The test results, opinions, or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated client. No reproduction or facsimile in any form can be made without the clients permission. This report shall not be reproduced except in full without the written approval of this laboratory. PRI Construction Materials Technologies, LLC, assumes no responsibility nor makes a performance or warranty statement for this material or products and processes containing this material in connection with this report PRI Construction Materials Technologies, U.C. 6408 Badger Drive Tampa, FL 33610 Tel: 813-621.5777 Fax: 813-621-5840 e-mail materialstesting@pricml.com WebSite: htlpJAvww.pdcmtcom