HomeMy WebLinkAboutNOA Supreme AR-3 Tab ShinglesMIAM amw _
PRODUCT CONTROL ECrI,
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 21
BOARD AND CODE ADMIMSTRAMON DMSION Miami, Florida 33175 24'
T (786) 315-2590 F (786) 315-25!
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/econon
Owens Corning Roofing and Asphalt, LLC
1 Owens CorningParkway
Toledo, OR 43659
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction: RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zo.ie of the Florida Building Code.
DESCRIPTION: Supreme AR 3 Tab Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews NOA#07-1116.12 and consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
APPROVED 1
t .. f
NOA No.:12-1204.03
Expiration Date: 03/20/18
Approval Date: 03/07/13
Page 1 of 4
C
ROOFING ASSEMBLY APPROVAL
Category:
Roofing
Sub-Cateeorv:
Asphalt Shingles
Materials
3-Tab
Deck Type:
Wood
SCOPE
This approves Owens Corning Supreme AR as manufactured by Owens Corning described in Section 2 of this Notice
of Acceptance.
PRODUCT DESCRIPTION
Product
Supreme AR
MANUFACTURING LOCATION
1. Atlanta, GA.
2. Jacksonville, FL.
3. Irving, TX.
4. Memphis, TN.
5. Medina, OH.
EVIDENCE SUBMITTED
Test Agency
Underwriters Laboratories, Inc.
Underwriters Laboratories, Inc.
PRI Asphalt Technologies, Inc.
Dimensions Test Product Description
Specifications
12" x 36" TAS 110 A heavy weight, fiberglass reinforced asphalt
shingle.
Test Identifier
Test Name/Report
Date
02NK45241
ASTM D 3462
12/05/97
05CA53426
12/02105
02NK45241
TAS 107
11/14/02
03NK04954
03/20/03
04CA52475
03/23/05
06CA03524
03/30/06
04NK40618
11/12/04
R2453
Reference
01/09/03
OCF-067-02-01
TAS 100
11/12/02
OCF-076-02-01
02/24/04
OCF-094-02-01
08/29/06
OCF-095-02-01
09/22/06
NOA No.: 12-1204.03
Expiration Date: 03/20/18
Approval Date: 03/07/13
Page 2 of 4
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building C
and Rule 9N-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS I IS.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail W, attached.
5. Nailing shall be in compliance with Detail W, attached.
LABELING
Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade
Product Control Approved".
MIAMFDADE COUNTY
BUILDING PERMIT REQUIREMENTS
Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to
evaluate the installation of this system.
M1AMHOADECQUNTY
NOA No.: 12-1204.03
�� Expiration Date: 03/20/18
Approval Date: 03/07/13
Page 3 of 4
E=3
EXPOSURE
DETAIL A
DETAIL B
36'
NAILS r-ADHESIVE STRIPE
6„ 8 „1011
END OF THIS ACCEPTANCE
m
MUd4K Q* NOA No.: 12-1204.03
Expiration Date: 03/20/18
Approval Date: 03/07/13
Page 4 of 4
UL Evaluation Report
UL ER2453-02
Issued: April 5, 2017
Visit UL•s On -Line Certiiicadons Directory. .ul.com/erdirectory
for current status of Report
UL Category Code: ULEZ
CSI MasterFormate 1
DIVISION: 07 00 00 — THERMAL AND MOISTURE PROTECTION
Sub -level 2: 07 30 00 — Steep Slope Roofing
Sub -level 3: 07 3100 — Shingles and Shakes
Sublevel 4: 07 3113 — Asphalt Shingles
COMPANY:
OWENS CORNING
ONE OWENS CORNING PKY
TOLEDO, OH 43659
(419) 248-7060
htto:/hv rr.oveenscomL_g.cornl
1. SUBJECT: Asphalt Shingles
CLASSICS, SUPREME®,
DURATION® PREMIUM, TRUDEFINITIONO DURATIONS, TRUDEFINITIONO DURATIONS STORM'rm,
TRUDEFINITIONO DURATION® MAX"U, TRUDEFINITIONO OAKRiDGEe, OAKRiDGES,
WOODCRESTS, WOODMOORS, TRUDEFINITIONO WEATHERGUARDS HP, BERKSHIRE%
DEVONSHIRE-,
WOODSTARTO STARTER SHINGLE, STARTER STRIP PLUS, STARTER STRIP SHINGLE, AND TRI
BUILT STARTER STRIP
BERKSHIRE@ HIP & RIDGE SHINGLES, HIGH RIDGE HIP & RIDGE SHINGLES WITH SEALANT,
RiZERIDGES HIP & RIDGE SHINGLES WITH SEALANT, WEATHERGUARDS HP HIP S RIDGE
SHINGLES, PROEDGES, DURARIDGE- HIP & RIDGE SHINGLES AND PROEDGES STORMS HIP
& RIDGE SHINGLES
2. SCOPE OF EVALUATION
■ 2015, 2012, 2009, and 2006 lntemational Building Code S (IBC)
■ 2015, 2012, 2009, and 2006 lntemationa/ Residential Code S (IRC)
■ [CC ES Acceptance Criteria for Quality Documentation (AC10), Dated December 2012
■ ICC ES Acceptance Criteria for Alternative Asphalt Roofing Shingles (AC438), Dated March 2012
The products were evaluated for the following properties:
■ External Fire Exposure (ANSI/UL790, ASTM El08)
■ Wind Resistance (ASTM D3161; ASTM D7158)
■ Physical Properties ( ICC-ES AC438)
3. REFERENCED DOCUMENTS
■ ANSi/UL790 Eighth Edition, (ASTM E108), Standard Test Methods for Fire Tests of Roof Coverings
■ ASTM D3161-13, Standard Test Method for Wind -Resistance of Steep Slope Roofing Products
(Fan -induced Method)
■ ASTM D7158-11, Standard Test Method for Wind Resistance of Asphalt Shingles (Uplift Force/uplift
Resistance Method)
■ UL Subject 2375, Outline of Investigation for Hip and Ridge Shingles (UL Fire and Wind Tests)
■ ICC-ES Acceptance Criteria for Alternative Asphalt Roofing Shingles (AC438), Dated March 2012
4. USES
OWENS CORNING asphalt shingles described in this report are alternatives to asphalt shingles
complying with Section 1507.2.6 of the 2015, 2012, 2009 and 2006 IBC and Section R905.2.4 of the
2016, 2012, 2009, and 2006 IRC, and are Class A roof coverings for new and existing roofs.
S. PRODUCT DESCRIPTION
OWENS CORNING asphalt shingles are roof covering materials complying with the following properties
when installed as described in this report. The products are three -tab shingles, laminated shingles and
hip & ridge shingles. The products are available in standard and metric sizes.
Fire Classification: OWENS CORNING asphalt shingles covered under this Report have been tested for
fire classification Class A in accordance with UL790 (ASTM El08). Shingles tested in accordance with
UL790 (ASTM E108) qualify for use under Section 1505.1 of the 2015, 2012, 2009 and 2006 iBC and
Section R902.1 of the 2015, 2012, 2009 and 2006 IRC.
Wind Resistance: OWENS CORNING asphalt shingles covered under this Report have been tested for
wind resistance in accordance with ASTM D3161 or ASTM D7158.
Shingles tested in accordance with ASTM D3161 are classified as Class F or Class A and qualify for use
under the exception to Section 1507.2.8.1 of the 20151 BC, Section 1507.2.7.1 of the 2012, 2009 and
2006 iBC, or the exception to Section R905.2.4.1 of the 2015, 2012, 2009 and 2006 IRC.
'Shingles tested in accordance with ASTM D7158 are classified as Class H and qualify for use in locations
as shown in Table 1504.1.1 of the 2015 IBC, Table 1507.2.7.1 of the 2012 and 2009 IBC or Table
R905.2.4.1 of the 2015, 2012 and 2009 IRC, where the maximum basic wind speed is 150 mph (67 m/s)
or less with exposure category of B or C (ASCE 7) and a maximum building height of 60 feet (18.3 m).
Installation must be in accordance with Section 1507.2.7 of the 2015, 2012, 2009 and 2006 IBC or
Section R905.2.6 of the 2015, 2012, 2009 and 2006 IRC, as applicable.
Physical Properties: OWENS CORNING asphalt shingles covered under this Report have been tested
for physical properties in accordance with AC 438. Shingles tested in accordance with AC438 qualify as
an alternative roof covering for use under Section 1507.2.5 of the 2015, 2012, 2009 and 2006 IBC or
Section R905.2.4 of the 2015, 2012, 2009 and 2006 IRC. When installed in new construction in
accordance with this report and the OWENS CORNING installation instructions, the shingles are a Class
A fire classification roof covering. When the shingles are installed over existing roof coverings, the fire
classification is maintained.
Page 2 of 30