HomeMy WebLinkAboutManufacturer Home Stairs 5-9-22STAIRS/LANDING/DECK
NOT CONNECTED TO
MOBILE HOME
TYP LANDING]
AS REQUIRED
TYP STAIR IS MIN 36" WIDE
NOTE:
TREADS - +/- 10"
RISERS = MAX 1.15"
TYP. STAIRS /
TYP. +/- 36" TALL RAILING
w/ 2 x 2 PICKETS
MAX 4" BETWEEN OPENING
TYP LANDING
TREADS SCREWED
g EACH STRINGER
w/ MIN (2) 010
3" DECKING SCREWS
TYP 4 x 4 PT POST ■
LIED t0 TOP OF FILLED BLOCK
w/ STEEL BRACKET - BLOCK IS
EPDXIED TO SLAB
TYP
ENTRY
Derr STAIRS
3t Pe,mrt� a�
TO 38"
WOOD RAILING NTS
MIN (3)
U U
F2x 12 PT STRINGERS
EXISTING]
'
v
v
MIN GRADE
POST CONNECTION
TYP MIN. 4 x 4 PT POST
A
A
V
5/4 PT
MIN. 12" x IS" x 24" CONC.
'
DECKING
F°OST MIN, 20" IN CONC.
A
TREADS
BELOW GRADE
A
AY
2x6 PT DECKING
DECK INFO
w/ (2) DECK SCREWS PER JOIST
(2) 2xS PT GIRDER BEAMS
TIED TO CONCRETE w/ (4)
MIN 2 x 8 Pt M2 SYP
2
MOBILE HOME TIE DOWN STRAPS
P.
TY P.
(2)
DECK JOIST 1 O.C.
SITTING ON FILLED BLOCK
2 x 8 PT JOISTS 9 MAX IS O.C.
_
THRU BOLTS
EACH BRG. OF JOISTS TO BEAM
OR
(2) 2 x 8 PT
w/ SIMPSON H3 CLIPS
LAGS BOLTS
—
BEAMS
2 x ro PT DECKING
OR EQUAL
ON
w/ (2) DECK SCREWS o EA JOIST
FASTENER
FILLED
FOR 2x8 PT
BLOCK
UNDERSIDE OF DECK
TO REMAIN OPEN
TYP,
DECK/LANDING DETAIL
NTS
AS -BUILT MANUFACTURED HOME
STAIRS/LANDING/DECK PLAN
FOR THE MOLLER RESIDENCE
10125 S OCEAN DR. - UNIT 529
JENSEN BEACH, FL 3495l
STEVEN G. WOOD
PROFESSIONAL ENGINEER
STATE OF FLORIDA PE - 34398
950 S.W. Sultan Drive
PORT ST. LUCIE , FL. 3495
PH (772) 878-7324
DECK
IS +/- 48" ABOI
EXISTING SLAI
TYP
RAILING6
REVISED LAYOUT FOR SETSACKS
5-S-22
'THIS STRUCTURE MEETS THE REQUIREMENTS OF CHAPTER 3,
SECTION 322, SUB -SECTIONS R322.1.8, R322.1.10, 4 R322.3.S
OF THE 2020 ZTH ED. FLORIDA RESIDENTIAL BUILDING CODE
9THE
K d STAIRS IN COMPLIANCE WITH PERMIT * 2105-0111
1105 WIND ZONE REQUIREMENTS
REVIEWED FOR
`."'ODE COMPLIANCE
ST' LUCIE COUNTY
13OCC