HomeMy WebLinkAboutPlumbing PlanPlumbing Plan
Legend
Pool
-- - — — - —— Returns 1.5'R
Waterfall
_._._ 1.5" R
... Skimmerg
2"
_-._.. _.._ Vac line O
2"
PooVMD�
2.5"
Spa MD o
2.5"
Jets 2" 01
Spa
Return
1.5"
----------------------------.
WIFE "I� _._._ _.I i
IF# R-------I------------•------ ;
1gX30, J
3v \ -tin shelf I I I
o �j sit I
Q ® I
� II
OO
• � I
t_.— �. .•—e .. ®. .-.. .�� .• a
Specifications
Pool Dimensions: 18' x 30' Area: 375 Sq Ft Perimeter:79' LN
Pool returns: 3 Vac Stub Out: Yes with Approved Vac Lock Pool Capacity:. 11220 gallons
Light: (3) 18 watt Savi Melody Skimmer: 1
Interior coating: Game coat . Safety ( Child Barrier )
Decking: New 1366 Sq Ft )f Concrete. Footers: 117 Linear Feet , 8"x8" w/#5R
Pump: Pentair Variable Speed @ 31.16 GPIM turnover Rate: 6 HR
Chlorin .tor: Salt Filtei Pentair 200 sq ft cartridge Clean and Uear
Spa 6. Round. Hydro jets 6, returns 2. ( 1 HP Air Blower )
2500 PSI ncrete 8"
4 8„
o 8" #3 Rebar
(1) # 5 rebar 12" 0 IB
or (2) #3
- Undisturbed soil underneath
rebar tooter _ _ —
continuous
Footer Detail N.T.S. Swim In Bench Detail
N.T.S.
Pum
P
WP Manual Blaner
Separate Circuit swllol lyp) Time Clock
for motor and light
GFI Panel
Breaker br �
pump WI CFI 10'.20EPump Motor
rom water
S. P. S.T • Junction Box
Toggle Pod
Switch Ligat Ground all Metal boxes.(hght,motor,ed).(Savi Melody light chat requires `w ground) With
#8 wire (solid)
light fuWres do not require ground fault interrupter
Electric Diagram N.T.S.
#8 Solid copper be
e w/ Appd.
Clamps(one we as
side of pool 4 lots
(1) 48 Bare cropper wire
tended 10 pool steel as
shown
EQUOPOTENTIAL
BONDING DETAIL
Per FL Build Code Adoplalion of
N.E.C. 2008 sec680.26
Pump & Filter to be screwed down
with 1.5 " long 1/8 or larger approved
concrete anchors.
Filter
Water
tin
2
deep
PVC/
Flex
Pipe .Bench
Cross 18. 18' N912"O.CI
( section Bw
1" Mtn cement 8 we /
coverage
channel Drain Ant i Min
ickness
Thick
s Entrapment Thfloor
Min Thick
PVC Piping In
Gunnite Spa X Section N.T.S.
Gel Cole over Compacted
Fiberglass fill
Pump & Filter Tie Down N.T.S Wall Section Cantilever
N.T.S
O 1 b of of reoosa&fL,Llarthar- 4" UnKtiti
REBAR Ca 12" O/C each way
3 FT to 5 FT- 6" Thick w/#3 Rebar®6" O/C each way
Q_i FTa" Thick w/43 Rebai@ 6" O/C each way
Angle Of
Dose N.T.S.
i
*
Excavation of angle of repose Is allowed providing
1- Shoring Is installed on excavaled surfaces sufficient to secure wil from
erosion or se8lemem.
2No undermining occurs, if undermining occurs consult a design professional
3. Compaction test of the hackfilled material are provided at C.O. of the pool.
216D
2" x 4"
@ 4'
2-hard toll T Nails .099
0,1 4 EMS
e
ngWall
aterial)lab
Shoring Detail N.T.S.
Water line
12 volt
1" sch 40 Transformer
pvc
4 inch NoJ-Box
min to 1,5 soh 40 PVC Needed
Ions z
14 inch min 1.5" conduit
No Bonding
needed
Light Detail SAVI MELODY
N.T.S.
TYP -1 12"
10" Edge
Edge
TJe
i
Steps N.T.S.
32"
I F
3 Y." J C Leal Tree Cover
2.5"SP x T'SOC x:
2.5
Spa/ Pool Drain N.T.S.
Rock waterfalls
Wafer Level
Concrete or Paver dead
2" or 1.5" PVC sch.
4� Pump Suction Side
Skimmer Detail N.T.S.
From Beam 22'
Total pool Lergth
Typical section through POOL N.T.S.
:). s",
.rzi;- d"':-. <f �
ifr sotisn•r -_U
11,
.iA ".ia...
<Fff
i�
$ I P
i Vf I
e
66f
f axtl,
N - ( ��
J 4 M
',• r•
II PLANS AND c ld,il N IRll`J,)RD it) fCf,iAN� �.
FVI,�l1 Ok r. n11
AN
NSI/lAS€T3, AN`;irCSRI 1, l15I;/NIPA5, ANY/11"PI6 ,r,dAN�FtAt'Sr /
ALL CONSTROCTION Aj,ab i iiki i +.TION4 CO CU IV Ili r ';?
'32011, AN:I/flWI 3 ANTI "14, ANSIINSPA'5, lid".}r/NSPt f, eIiJAN"I,fAP`rP
;( GUNITEtSti) I TF If Ikk i0fio Psi aAIFLF1, Il =:a1
,I) ALL STEEL SLIM LFt (,RA[)( MINIMUM
„ c - a .� ;CI �,r �. Y �, INSTALLATIOF,• `,1i4 1,,r)M LY WiTII FBC f'Ll1tt961Nc.
1 I , ALL PIPING SHALL L. c
2014
At I �� CO`V Ih,IfDUS SOIL BEARING ON CLEAN COMPACTED SOILIIVITN 7f7001'SL
r.j ,ALLPOOL
miNIN1
RAINIPv1')M. '
NDRAI' S, LADDERS, LIGHTS SHAi t BE BONDED WITH #S GROUND WIRE PER NEt- 580
S} POOL .ANDSPA SHALLBE PROVIDED WI III APPROVCD CHILD GARRiER OR SCREENFNCLOSURE, HOUSE
SAFTE`f BARRIER OR ALARM SYSTEM AtL IN ACt ORDAI`dCE WITH FBCR 4502.17.1,
9( ALL GAS AND FUEL PIPING SIiALL LEPER F BC rUFi AND GAS2014 (SEPARATF CONTRACTOR).
10) At l ELECTRICAL INSTALfATIi)NS SH,A_L BF IN ACCORDANCE WITH NEC 2011 EDITION.
1S) POC1k AND SPA E1IUIPNIENI SHALL BESECURED To CONCRETE PAD,
3}' At iER COMPLETION OF POOL HOMEOWNER SHALL CONSUO LISCFNSED POOL.
LoNFRACIOR IN ORDER 10 DRAIN POOL ii SO DESiRFD.
HEATING Et41UPh,1ENT SI IALI COICJpLV WITH FSt 11 7Q1Ik
Pools By
Vitali,INC
Do not duplicate - This
drawing is the property of
(Family Pools Inc) and may
PAGE DEPT
be purchased separately for
$250. No duplication allowed.
violators may be prosecuted. Scale:l-=10,
Imran Malik
8335 Calumet CT.
Port ST. Lucie. FL.
Pools By Vltali,INC.
State Lie. CPC# 1458526
DESIGNER
Vitali Bederak
SHEET 1 OF 1
.P,; ; •rVELCH INC.
ME..CH-ELr_C:"'! .',,iVIL ENG. 1
1984 UILI`N11 ST. #114 i
PORT SAINT Luc,1E, FL 34984
PAUL WELCH P.E.
FLA REG 1110.29945 1�ul_ 2 Zp7�