Loading...
HomeMy WebLinkAboutTotal Dynamic Head CalculationIle Copy PROJECT NAME: PROJECT ADDRESS IMRAN MALIK POOL 8335 CALUMET CT. PORT ST. LUCIE, FL TOTAL DYNAMIC HEAD (TDH) CALCULATION DETERMINE MAXIMUM FLOW RATE PER ANSI / ASPS -15 2013 MINIMUM FLOW RATE REQUIRED: 35 gpm / SKIMMER 1 SKIMMER PER 800 ftZ OF SURFACE AREA SURFACE AREA = 375 ftZ MEAN DEPTH = 3.9995 ft POOLVOLUME = 375 ftZ X 3.9995 ft X 7.481 gal/ft3 = 11220 gal TURNOVER TIME = 6 hr X 60 min./hr = 360 min. MAXIMUM FLOW RATE = POOL VOLUME / TURNOVER = 31.17 gpm SPA FLOW RATE = 31.17 gpm MAX PIPE SIZES AT MAXIMUM SYSTEM FLOW RATE BRANCH PIPING SHALL BE N/A inch AT 6 fps MAX AT #N/A gpm TRUNK PIPING SHALL BE 2.5 inch AT 8 fps MAX AT 119 gpm RETURN PIPING SHALL BE 1.5 inch AT 10 fps MAX AT 63 gpm PUMP MAKE / TYPE INTELLIFLO VS 3.0 HP MAX MAIN DRAIN / COVER AQUASTAR 32 CDFL 32" APPROVED COVER RATE 316 gpm CERT. # PR 25255017 Sheet 1 of 3 SIGNATURE / DATE PAUL WELCH INC. PAUL WELCH P.E. CERT# 29945 7/28/2017 -;,rl r A PROJECT NAME: IMRAN MALIK POOL PROJECT ADDRESS: 8335 CALUMET CT. PORT ST. LUCIE, FL TOTAL DYNAMIC HEAD (TDH) CALCULATION WORKSHEET DETERMINE MAXIMUM FLOW RATE PER ANSI / ASPS -15 2013 FRICTION LOSS FOR 2.5 inch SUCTION PIPE PER ft AT 119 gpm = 0.08 ft (PER TABLE) } FRICTION LOSS FOR 1.5 inch RETURN PIPE PER ft AT 63 gpm = 0.21 ft (PER TABLE) 50 ft. SUCT. PIPE X 0.08 ft HEAD / ft = 4 TDH FOR SUCT. PIPE 50 ft. RETURN PIPE X 0.21 ftHEAD / ft = 10.5 TDH FOR RETURN PIPE TABLE: SMOOTH PIPE SCH 40 PVC / FLOW AND FRICTION LOSS PER FT PIPE DIAMETER in 6 ft/sec 8 ft/sec 10 ft/sec 1 16 gpm 0.13 ft 22 gpm 0.23 ft 27 1 gpm 0.35 1 ft 1.5 38 gpm 0.08 ft 51 gpm 0.14 ft 63 1 gpm 0.211 ft 2 63 gpm 0.06 ft 84 gpm 0.10 ft 105 gpm 0.16 ft 2.5 90 gpm 0.05 ft 119 gpm 0.08 ft 149 gpm 0.13 ft 3 138 gpm 0.04 ft 184 1 gpm 1 0.071 ft 1 230 gpm 0.10 ft 4 238 gpm 0.03 1 ft 317 i gpm 1 0.0.51 ft 1 397 gpm 1 0.07 ft 7/28/2017 af UR /DATE SIGNATURE°/ DATE NTRA O R:: VITALI BEDERAK PAU.L WELCH INC. RT. # PR 25255017 PAUL WELCH P.E. Sheet 2 of 3 CERT# 29945 PROJECT NAME: PROJECT ADDRESS: 100 • 90 so 0 30 H 20 10 0 IMRAN MALIK POOL 8335 CALUMET CT. PORT ST. LUCIE, FL . ........ Factory Preset Speeds i r: t s 9 I 31 t0 RPM 2J50RPM {500 RPM _ 750 RPM r- �, 0 20 40 60 80 10D 120 140 160 Flow Race in U.S. GPM NOTE The chirt above demonstrates perfotn-ance rates at (ictory preset speeds of 7S0 RPM. IS40 RPM.23S0 RPM and 3110 RPM.Howeve ,flaw mws' can also be custom Programmed between the range; of 400 RPM and 34SO RPM as indicated by the blue tint. TDH IN PIPING: 14.5 ft FILTER LOSS IN TDH: 8.0 ft HEATER LOSS IN TDH 0.0 ft OTHER LOSSES IN TDH: 0.0 ft TOTAL SIMPLIFIED TDH: 22.5 ft NOTES: 1) PUMP OR HEATER MAKE / MODEL MAY NOT BE CHANGED 2) INSTALLATION SHALL COMPLY WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. 3) EQUIPMENT LOCATIONS MAY NOT BE CHANGED. 4) VARIABLE SPEED PUMP USE MAXIMUM FLOW IN CALCULATION. SI U E / T CO TRA TOR: VITALI BEDERAK CERT. # PR 25255017 Sheet 3 of 3 SIGNATURE [DATE PAUL WELCH INC. PAU.L WELCH P.E. CERT# 29945 7/28/2017