Loading...
HomeMy WebLinkAboutSite Plana Eusebio M. Architect Fla. Lic. # ProposedInteriorRemodeling: MR. JINO DESARME 2880 HARSON WAY FORT PIERCE, FLORIDA 33946 ZONING DATA ZONING: INDUSTRIAL LIGHT — IL HEIGHT (to ridge) — 2 Story — 35ft. max NET LAND AREA LOT COVERAGE (everything under roof)( 2 Story) SET BACKS: FRONT SIDE SIDE STREET REAR REQUIRED 25-0" 10'—O" 15'-0" 25'—O" SCOPE OP \I 0RK 20'-11" 9,225 sq ft 2,700 (29.26%) PROVIDED 31'-2" EXISTING 11'-2" & 5'-8" EXIST. _N/A 70'-3" EXISTING 1. DEMOLITION OF PORTION OF 4" PARTITIONS WALLS. 3. EXISTING A.H.0 TO BE REMOVED & REPLACED IN SAME LOCATION. 4. DEMOLITION OF WOOD WALL TO PROVIDE OPENING FOR ORIGINAL GARAGE DOOR.. 5. ELECTRICAL WORK. SEE ELECTRICAL PLAN. 6. PLUMBING WORK, SEE PLUMBING PLAN. 7. MECHANICAL WORK, SEE MECHANICAL PLAN. Sot ILkg iL R� at �U4 ,IT 07g*:O CONCEALED FASTENERS OR ATTACHMENTS ARE IRE RESPONSIBILITY OF THE CONTRACTOR OF RECORD THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTION': REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE COOLS. �yMpNUFACTUtiES GG C0APt­"CF- ij V FW ENDZ DS "MUNSI F1 �N O �3 ARE APM)VEO � S00*9527" W 74.93' IL PLAN 1/8" HARSON WAY 20,00' ASPHALT PAVEMENT L E G A L DESCRIPTION: LOT 25, BLOCK 59, FIRST ADDITION TO FAI�LAWN ESTATES, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 62, PAGE 41, OF THE PUBLIC RECORDS OF MIAMI—DADE COUNTY, FLORIDA. 8752 Southwest 143rd StI Palmetto Bay, Florida 33 (305) 235-75 moraarch @ bellsouth. W W Q W z Q 1L W W U) 0 w J) W> o�m w 0 Yj 1' Of a LU w A O N C N v m s o (0 o Cam') w a� eV) J c I tL U W Cd cc 6 a- �I Cr CO U_ 0W Q ®® z O CO C ® CO O T_ vA OL 00 w Ooo (L0 C4 J H � F a DRAWNBY. EAC CHECKED BY. EMf ATTACHMENT NO.. ATTACHMENT DRAWING FILE NO.: 2017-03 DATE: 09/01 /201 SCALE. NOTE[ ;r�rL 5 SHEET NUMBER File C Al OF EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING TUB TO BE REMOVED & REPLACED IN SAME LOCATION EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW TO REMAIN TO REMAIN I TO REMAIN TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW To PFUAIM EXISIING WNDUW TO REMAIN EXIST. C.0 UNIT r--- TO BE REMOVED _ AND REPLACED ! (" IN SAME LOCATION I ((( V!! I TO REMAIN EXISIING WINDOW TO REMAIN EXISTING/DEMO FLOOR EXISTING WINDOW TO REMAIN PLAN 2nd FLOOR () EXIST. C.0 UNIT ni ul I TO BE REMOVED tit AND REPLACED EXIST. D00 (X =%n �IN SAME LOCATION TO REMAIN L- EXISTING WINDOW TO REMAIN 1/4W 3 p 0 oz 0 z z U• � z Z� X W X W 3o NEW NB 0 z? �a w z� NO w~ 30 0 L. w w ===� I ----- I Iris ^111 I YL.iJL ___________ -- L J L -----------I `iJIL-- — EXIST. RANGE CAB. TO BE REMOVED EXIST. RANGE CAB. TO BE REMO D AND REPLACED AND REPLACED IN SAME LOCATION IN SAME LOCATION EXIST EXIST. EXIST. KITCHEN EXIST. DINING KITCHEN EXIST. SINK / CAB. EXIST. REFRIG. TO BE REMOVED TO BE REMOVED EXIST. REFRIG. EXIST. SINK /CAB. DINING TO BE REMOVED & REPLACED & REPLACED EXIST. CL. & REPLACED TO BE REMOVED EXIST. & REPLACED CL. r= =--=,r _- 4 - - - - - - - I �, II i L-------------- IL IIr1r II J —- - - - - - - - - - - - - - IIC�CJII— I EXIST. LAV./ CAB. �_____� L--__—_J TO BE REMOVED ��- (-- 1 .%_. o EXIST. LAV./ CAB. AND REPLACED a ` I ! �y=�" TO BE REMOVED &, I EXISIING ELECT. PANEL ! EXISTING ELECT. PANEL � L - REPLACED I II U XIST. BATH--� EXIST. A.H.U. EXIST. A.H.U. r--71 TO BE REMOVED TO BE REMOVED EXIST. TOILET i & REPLACED & REPLACED TO BE REMOVED & TO BE REMOVED MOVEDED L -y --J REPLACED it EXIST. WATER HEATER EXIST. WATER HEATER TO BE REMOVED, REPLACED & RELOCATED TO BE REMOVED, REPLACE & RELOCATED ! II II EXIST EXIST ----- GARAGE ------ GARAGE ------ r---------------� EXIST, - EXIST. LIVING LIVING EXISTING GARAGE DOOR UP. EXISTING WOOD WALL UP. TO BE REMOVED FOR PROVIDE OPENING FOR ORIGINAL GARAGE DOOR \ I I I I - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - I I -----__-- - - - -� F— — �7 I NEW NEW 4" 1 —71 EXIST. W.I.C. 01 W.I.0 PARTITION WALL (BACK TO ORIGIN EXIST. EXIST, BEDROOM EXIST, EXIST. BEDROOM BEDROOM BEDROOM (BACK TO ORIGINAL LAYOUT) EXIST. NEW 4° NEW PARTITION WALL W.I.C. W.I.C. (BA TO ORIGINAL 01 LAYOUT) NEW TOILET NEW LAVATORY & CABINET NEW 4" NEW TOILET NEW TUB PARTITION WALL NEW LAVATORY • EXIST_ NEW & VANITY CABINET CL. (BACK TO ORIGINAL LAYOUT) EXIST. EXIST. BATH. BATH. DN. IAN\) 02 DN I EXIST. EXIST. - --- BEDROOM BEDROOM ---- EXIST. EXIST. (BACK TO ORIGINAL LAYOUT) ------ BEDROOM BEDROOM IF EXIST. EX ST. W.I.C. W..C. 3 p 0 oz 0 z= g Z� �W F� W 0 3 0 0 a � z� z� N� NO ~ X W W 2"X4" WOOD BACKING AT TOP OF WALL CABINET EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISIING WINDOW TO REMAIN F DODEMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN .. wool wom A'1► `• a -. �°" • . • - • EXIST. DOD TO REMAIN EXISTING WINDOW TO RFIAAIN ------------------ NEW 40 GAL. O O NEW 40 GAL. ----------- O WATER HEATER / WATER HEATER O XX� NEW COUNTER. NEW RANGE NEW NEW NEW RANGE NEW COUNTER. NEW WASHER/DRYER KITCHEN NEW STACKABLE WASHER/DRYER NEW STACKABLE NEW EXIST. KITCHEN EXIST. DINING DINING NEW COUNTER. NEW SINK NEW REFRIGERATOR EXIST. EXIST. NEW SINK NEW COUNTER. o C_L CL o --- ---_----- — — -- O -- ------ NEW LAV./ CAB. c EW LAV./ CAB. II II u II II II II II II TIIIIIIII EXIS NEW DOOR BAIi BATH� IIIIIIII NEW TOILET EXIST. i EXIST. NEW TOILET C.L. II II II CCL I II II II EXIST. II II I1 EXIST. - GARAGE GARAGE ------ ____ I I EXIST. -- I I I -- EXIST. LIVING I I I I LIVING I I I I I I I I UP. I I I I I I I I I I i UP. I I I I I I I I I I I I I I I I I I I I I I I EXISTING WINDOW EXIST. DOOR EXIST. DOOR EXISIING WINDOW EXISTING WINDOW EXIST. DOOR EXIST. DOOR EXISTING WINDOW TO REMAIN TO REMAIN TO REMAIN TO REMAIN r//////A TO REMAIN TO REMAIN 03 NEW GARAGE EXIOR ST. GARAGE 771 TO REMAIN THESE PLANS, DOCUMENTS & CALCULATIONS ARE BEING PREPARED IN COMPLIANCE WITH THE FBC 2014 EDITION FBC 2014 - ALTERATIONS LEVEL 2 COMPLIANCE THIS PROJECT SHALL COMPLY WITH THE FLORIDA BUILDING CODE 2014 EXISTING BUILDING, CHAPTER 7 - ALTERATIONS - LEVEL 2 EXISTING/DEMO FLOOR PLAN 1st FLOOR 1/4n WINDOW SCHEDULE MARK I STAND. WIDTH HEIGHT TYPE FRAME REMARKS A HS 34 53 1/8" 50 5/8" SINGLE HUNG ALUMINUM MATCH EGRESS EXIST WINDOW FINISH U-FACTOR=065 SHGC =0.25 NOTES: 1 - SINGLE HUNG EGRESS TYPE WINDOW OPERABLE FROM THE INSIDE WITHOUT THE USE OF TOOLS & PROVIDING A CLEAR OPENING OF NOT LESS THAN 20" IN WIDTH, 24" IN HEIGHT & 5.7 S.F. IN AREA. THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN OFF THE FLOOR. ONE EGRESS TYPE WINDOW TO BE INSTALLED IN EACH BEDROOM. 2 - PROVIDE IMPACT GLASS ® DOORS & WINDOWS AS PER F.B.C. 2014 3 - PROVIDE TRANSLUCENT GLAZING AT BATHROOM WINDOWS. DOOR SCHEDULE MARK WIDTH HEIGHT THICK TYPE DESCRIPTION REMARKS H> .WI'` of 3'-0" 6'-8" 1-3/4" BIFOLD WOOD 02 6'-0" 6'-8" 1-3/4" BIFOLD METAL 03 8'-0" 6'-8" 1-3/4" GARAGE METAL • PR VIDE BACKING FOR VJALL CABINETS F.B.C. 2007 - RESIO. (2.) A MINIMUN 2 X 4 HORIZONTAL WOOD MEMBER, SEC URELY INTE IQR PARTITION WITH A TENED TO NOT LESS THAN 2 SUCH STUDS SHALL BE 3 5 8 METAL STUDS A INSTALLED FOR THE ATTACHEMENT OF EACH WALL HUNG ® 16" O.C. PLUMBING FIXTURE AND WALL CABINET. • PROVIDE 20 GA. MR. STUDS 0 16" O.C. 0 KITCHEN CABINETS WALL TOP OF PLATE 2"X4" WOOD BACKING AT TOP OF WALL WALL LEGEND WALL CABINET Exist. 6" Wood wall to remain Exist. drywall partition wall to remain 2 X4 yypop gq�Kl Exist. drywall partition wall AT BOTTON OF WAND to be demolished HUNG PLUMBING D ATINA W WALL New drywall partition wall SECTION VIEW New 8" Wood wall am WALL HUNG FIXTURE DETAIL 1' PROPOSED FLOOR PLAN 1st FLOOR 1/4 " 1. DEMOLITION OF PORTION OF 4" PARTITIONS WALLS. 2. EXISTING A.H.0 TO BE REMOVED AND REPLACED IN SAME LOCATION. 3. DEMOLITION OF EXIST. WOOD WALL TO PROVIDE OPENING FOR ORIGINAL GARAGE DOOR. 5. ELECTRICAL WORK. SEE ELECTRICAL PLAN. 6. PLUMBING WORK, SEE PLUMBING PLAN. 7. MECHANICAL WORK, SEE MECHANICAL FDLAN. Eusebio M. Mora Architect Fla. Lic. # AR0011732 8752 Southwest 143rd Street Palmetto Bay, Florida 33176 (305) 235 -7500 moraarch @ bellsouth.net Z O J O 2 W 0 �1�Ay Xd W W Y ro W W W W I1J I- Q 0 co Y LU W O Z O a> U c O "p 00 O a> O O_ O� 00 CW) O 'c J IL O 0 0 CD LI Ir ca .� EL a c'ry O rLJJJJ � L� Q ®7 co c 00 oI� 00 CC w L o 00 N � a DRAWN BY MVP CHECKED BY. EMM ATTACHMENT NO. ATTACHMENT# DRAWING FILE NO.: 2017-030 DATE: 09/01 /2017 SCALE. .�1 g®NOTED SH $3& 1C%pdv A2 OF Eusebio M. Mora Architect Fla. Lic. # AR0011732 THESE PLANS, DOCUMENTS and CALCULATIONS ARE BEING PREPARED IN COMPLIANCE WITH THE FBC 2014 EDITION ALTERATIONS LEVEL 2 COMPLIANCE LINE OF BOTTOM CHORD OF WOOD TRUSSES TRACK PLATE 16" 1.) TOP MTL TRACK PLATE 2" x 4" PT. WD. BOT. PLATE CONC. FLOOR INT. PARTITION DETAIL 1" EXIST, ROOF TO REMAIN UNIT Q NEW GAKAUt LUCK03 EXISTING GARAGE DOOR �� ZONt 4 (+53) (-55) I 8752 Southwest 143rd Street Palmetto Bay, Florida 33176 (305) 235 -7500 moraarch @ bellsouth.net m Q W W K W H Q E U) Z O Q W W U C N CID N L N L 0) O C") C) O Cd L. W Cr w CLI� �Q Cn LL EW 0 a °® z Cl) _ �. I o N w®� J p C r Cl- DRAWN BY: MVP CHECKED BY. EMM ATTACHMENT NO.: ATTACHMENT# DRAWING FILE NO.'. 2017-030 DATE. 09/01 /2017 SCALE: NOTED eli SHEET NUMBER: wile copy A3 OF 3 Eusebio M. Mora Architect Fla. Lic. # AR0011732 ELECTRICAL NOTES 1. GROUNDED ROMEX or 'SMURF' MAY BE USED. 2. RIGID GALVANIZED STEEL CONDUIT SHALL BE USED WHERE EXPOSED UP TO 4 FEET AND SUBJECT TO MECHANICAL INJURY OR IN DAMP OR WET LOCATIONS, 3. STEEL RACEWAY INSTALLED UNDERGROUND SHALL BE PAINTED WITH TWO COATS BITUMASTIC PAINT. 4. WALL OUTLET BOXES SHALL BE 4' SQUARE. CEILING OUTLET BOXES SHALL BE 4" OCTAGON OR SQUARE. 5. CONTRACTOR SHALL FURNISH AND INSTALL ALL ELECTRICAL. PANELS, WIRING DEVICES, CONDUIT, WIRING, MISCELLANEOUS SYSTEM, ETC. AS SHOWN ON PLANS OR AS REQUIRED FOR ACOMPLETE ELECTRICAL INSTALLATION. 6. FIXTURES AND LAMPS SHALL BE FURNISHED BY THE OWNER AND INSTALLED BY THE ELECTRICAL CONTRACTOR, UNLESS NOTED OTHERWISE, SEE NOTE 17. 7. PANELBOARD-ALL CURRENT CARRYING COMPONETS SHALL BE COPPER. SPLIT OR TWIN TYPE BREAKERS ARE NOT ACCEPTABLE. CIRCUIT DIRECTORIES SHALL BE NUMBERED CONSECUTIVELY ON THE LEFT SIDE TO 50X AND CONTINUED ON THE RIGHT SIDE. 8. DISCONNECT SWITCHES SHALL BE GENERAL DUTY. 9. PROVIDE PULL WIRE IN EACH EMPTY RACEWAY. 10. CONTRACTOR SHALL DO ALL CUTTING, SLEEPING, EXCAVATING AND BACKFILLING NECESSARY FOR THE INSTALLATION OF HIS EQUIPMENT AND THE PATCHING THEREAFTER. 11. CONTRACTOR SHALL INSTALL ALL STARTERS AND CONTROL. DEVICES FURNISHED BY OTHER CRAFTS AND COMPLETE WIRING IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS AND APPROVED WIRING DIAGRAMS. ELECTRICAL EQUIPMENT FURNISHED BY OTHERS WILL BE CONNECTED UNDER THIS CONTRACT INCLUDING ALL NECESSARY WIRING, CONDUIT, AND FI i 11NGS. CONTROL WIRING SHALL BE UNDER THE SUPERVISION OF THE SUB -CONTRACTOR FURNISHING THE EQUIPMENT. 12. ELECTRICAL WORK SHALL COMPLY WITH ALL APPLICABLE LOCAL OR NATIONAL CODES AND WITH THE UTILITY COMPANY REGULATIONS. 13. PRIOR TO INSTALLATION OF ROUGH ELECTRICAL WIRING CHECK NAMEPLATE DATA OF AIR CONDITIONING EQUIPMENT, HOT WATER HEATERS, AND OTHER EQUIPMENT TO OBTAIN CORRECT WIRE SIZES AND OVERCURRENT PROTECTION. 14. ELECTRICAL INSTALLATION SHALL CONFORMTO REQUIREMENTS OF N.E.C. 110-16(a) AND N.E.C. 384-2 FOR PANELBOARDS, INCLUDING SPACES ABOVE THE EQUIPMENT 15. CONTRACTOR SHALL PREWIRE ALL TELEPHONE OUTLETS WITH 4/C #24 TELEPHONE CABLE RUN IN PARTITIONS AND DROPPED CEILING FROM INCOMING TELEPHONE JUNCTION BOX. 16. CONTRACTOR SHALL PREWIRE ALL TELEVISION OUTLETS WITH RG6 COAXIAL CABLE RUN IN PARTITIONS AND DROPPED CEILINGS FROM INCOMING CABLE T.V. JUNCTION BOX. 17. CONTRACTOR SHALL PROVIDE 4' RECESSED HI -HAT LIGHTING. COORDINATE SELECTIONS WITH OWNER. ELECTRICAL INSTALLATION DESIGNED OF THIS PLAN IS INCOMPLIANCE AS SET FORTH BY STATE OF FLORIDA STATUTES MODEL ENERGY EFFICIENCY CODES. SYMBOL LEGEND MARK DESCRIPTION MARK DESCRIPTION DUPLEX RECEPTACLE OUTLET SURFACE MTD. FLOURESCENT SWITCHED RECEPTACLE OUTLET RECESSED MTD. FLOURESCENT SINGLE RECEPTACLE OUTLET D(D< FLOODLIGHTS SURFACE MTD. QUADRUPLEX RECEPTACLE OUTLET O® HEAT LAMP & EXHAUST FAN COMBO FLOOR DUPLEX RECEPT OUTLET ® ELECTRICAL PANEL SINGLE SPECIAL PURPOSE OUTLET SINGLE POLE SWITCH TELEPHONE OUTLET $ 3 THREE WAY SWITCH TV TELEVISION OUTLET $ D SINGLE POLE SWITCH W/ DIMMER JQ JUNCTION BOX DISCONNECT SWITCH FAN BOX W/ INCANDESCENT FIXTURE EXHAUST FAN WALL MTD. INCANDESCENT DOOR BELL SURFACE MTD. INCANDESCENT D SMOKE DETECTORS TO BE HARDWIRED & INTERCONNECTED TO NON -SWITCHED CIRCUS S OR BATHROOM LIGHTING 4" RECESSED HI - HAT D COMPUTER DATA / LAN OUTLET COMBINATION ELECT. METER CAN & DISC. 150 AMP WP MAIN DISCONNECT 150 AMP - WP MAIN DISCONNECT INTERSYSTEM BONDING CONNECTION DEVICE TO COMPLY W/ NEC. 250.94 (2) 5/8" x 10 GROUND RODS W/(1) #4 (CU) 1N 3/4" CONDUIT (3)-400 THW (CU} IN 2 1/2" CONDUIT TO F.P.L. X-MER M -1 THW CU & -6 THW CU GND 2" CONDUIT NEW ELECT. PANEL „A„ 150 A W/ MCB BOND TO COLD WATER LINE GROUND TO STL. REINFORCEMENT @ FOUNDATION ELECTRIC RISER N.T.S. NOTE: ALL SAFETY SWITCHES TO HAVE 100,000 RMS SYS MINIMUM FAULT CURRENT RATING. (USE TYPE R FUSES REJECTION KIT AND SOLID NEUTRAL.) PANEL SHALL BE DEAD FRONT CIRCUIT BREAKER TYPE AS SCHEDULED. CICUIT BREAKERS SEAL HAVE A MIN. INTERRUPTING RATING OF 10,000 AMPS AT 120 VOLTS / 15,000 AMPS AT 277 VOLTS. �1�-6 THW (CU3 ND IN 2' CONDUIT NEW ELECT. PANEL „B„ 150 A W/ MCB ALL RECEPTACLES SPECIFIED IN NEC 210.8, 120 V, 15 OR 20 AMPS, SHALL HAVE GROUND FAULT CIRCUIT INTERRUPTER PROTECTION (GFCI PROTECTION). ALL 120 V, SINGLE PHASE 15 OR 20 AMPS BRANCH CIRCUITS SPECIFIED IN NEC 210.12 (B) SHALL BE PROTECTED BY AFCI BREAKERS. ALL RECEPTACLES SPECIFIED IN NEC 210.52, 120 V, 15 OR 20 AMPS, SHALL BE LISTED TAMPER -RESISTANT RECEPTACLES (NEC 406.11). LIGHTING EQUIPMENT SHALL BE IN COMPLIANCE W/ FBC SECTION 404 LIGHTING EQUIP. A MINIMUM OF 75% OF THE LAMPS IN PERMANENTELY INSTALLED LIGHTING FIXTURES SHALL BE HIGH -EFFICACY LAMPS. THE MINIMUM EFFICACY SHALL BE: 1. - 60 LUMENS/WATTS FOR LAMPS OVER 40 WATTS 2. - 50 LUMENS/WATTS FOR LAMPS OVER 15 WATTS TO 40 WATTS 1. - 40 LUMENS/WATTS FOR LAMPS 15 WATTS OR LESS ALL RECESSED LIGHTING FIXTURES TO BE IC RATED AND AIR TIGHT (*)- NON -LOCKING RECEPTACLES IN DAMP AND WET LOCATIONS SHALL BE LISTED WEATHER RESISTANT TYPE WITH A WEATHER PROOF ENCLOSURE AS PER NEC 406.8 (A) & (B). PROVIDE SMOKE DETECTORS INSIDE & OUTSIDE OF ALL SLEEPING AREAS AS PER FBC 907.2.10.1.2(1) & (2). ONE INITIATING DEVICE SHALL BE A COMBINATION OF SMOKE & CARBON MONOXIDE DETECTOR ALL SMOKE ALARMS TO BE INTERCONNECTED SO THAT THE ACTUATION OF ONE DEVICE WILL ACTIVATE ALL ALARMS AND SHALL BE INSTALLED N ACCORDANCE WITH WITH FBC R314, 2014 EDITION AND NEC 2011 THESE PLANS, DOCUMENTS & CALCULATIONS ARE BEING PREPARED IN COMPLIANCE WITH THE FBC 2014 EDITION & NEC 2011 PANELS 'A' AND "B' ARE EQUAL. ELECTRICAL SCHEDULE 'A' 120 / 240 V - 10- 3 WIRE 150 A FLUSH MTD, PANEL CIRCUIT NUMBER WIRE SIZE DESCRIPTION POLES C/B TRIP LOAD (WATTS) DEMAND NO. DEM. EXISTING LOADS EXIST. # 14 LIGHTS / RECEPT. (3W x 1524 S.F.) 1P-15 A 4572 EXIST. # 12 GFI RECEPTACLES 0 BATHROOM 1P-20 A 1500 EXIST. I # 12 REFRIGERATOR 1000 EXIST. # 12 DISHWASHER 1P-20 A 1500 EXIST. # 12 SMALL APPLIANCES (2 @ 1500 W) 1P-15 A 3000 EXIST. # 6 RANGE 1P-20 A 12000 EXIST. # 12 EXHAUST FAN OVER COOKTOP 2P-50 A 1000 EXIST. # 8 A/C-1 - C.U. 0 125% 1 2P-40 A 6200 * EXIST. # 8 A/C-1 - A.H.U. W/ 5.0 KW HEATER 1P-20 A 6500 * NEW LOADS A-27,28,2S # 14 LIGHTS / RECEPT. (3W x 242 S.F.) 1P-15 A 726 A-30,32 # 6 WATER HEATER 2P-30 A 3500 A-31 # 12 WASHER 1P-20 A 1500 A-33,35 # 8 DRYER 2P-30 A 5000 TOTAL LOAD 35,298 6500 * NON -CONCURRENT LOADS LOAD CALCULATIONS: FIRST 10,000 VA @ 100% = 10,000 VA 30,619/240 = 127.58 AMPS REMAINING 25,298 VA @ 40% = 14,119 VA A/C LOAD 6,500 VA @ 100% = 6,500 VA TOTAL LOAD = 30,619 VA PRIOR TO INSTALLATION OF ROUGH ELECTRICAL WIRING CHECK NAMEPLATE DATA OF AIR CONDITIONING EQUIPMENT, HOT WATER HEATERS, AND OTHER EQUIPMENT TO OBTAIN CORRECT WIRE SIZES AND OVERCURRENT PROTECTION. RANGE & DRYER SHALL BE PROVIDED W/ 4 CONDUCTORS AS PER NEC 250.140 For RANGE - 3 6 and (1) # 10 Ground For DRYER - �3� 10 and (1) # 10 Ground LOAD STUDY: PANEL DEMAND NOMA DEMAND PANEL 'A' 35,298 W 6,500 W PANEL 'B' 35,298 W 6,500 W SUBTOTAL 70,596 W 13,000 W FIRST 10,000 W @ 100% = 10,000 WATTS REMAINING 70,596 W @ 40% = 28,238 WATTS A/C LOAD 13,000 W @ 100% = 13,000 WATTS TOTAL LOAD = 51,238 WATTS 51,238 / 240 = 214 AMPS 1. REMOVE, REPLACE & RELOCATE. 2. PROVIDE NEW HI HATS IN KITCHEN. 3. PROVIDE NEW CIRCUIT FOR ILLUMINATION EGRESS. 4. PROVIDE NEW GFI, ILLUMINATION AND EXHAUTS CIRCUITS IN NEW BATHROOM (1 FLOOR) . 5. PROVIDE NEW OUTLETS AND ILLUMINATION CIRCUITS IN NEW BEDROOM . 6. RELOCATE CIRCUITS FOR WATER HEATER & WASHER/DRYER. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. NEW EAST. BEDROOM Al I, C. - SMOKE DETECTORS TO BE HARDWIRED SMOKE DETECTORSECTE TO BE HARDWIRED W''C. EXIST. & INTERCONNECTED TO NON -SWITCHED &INTERCONNECTED TO NON -SWITCHED KITCHEN OR BATHROOM LIGHTING (BACK ORICINAL BEDROOM KITCHEN OR BATHROOM LIGHTING CIRCUITS. YOUT CIRCUITS. EXIST EXIST. EXIST. EXIST. EXIST. BEDROOM EXIST. EXIST. EXIST. BEDROOM NEW EXIST. NEW NEW SU W.I.0 C NEW NEW S W.I.C. -C EXIST. (BAC TO ORIGINAL EXIST. =0 EXIST. LAYOUT EXIST. rEAT. NEW EXIST. A-29 FI ° NEW SC SC EW o G. T. EXIST._ EXIS. L. _NEW CL. BACK TO ORIGINAL AST. EXIST. LAYOUT) EXIST. un ST. EXIST. EXIST, E TH. BATH. BATH. DN. (PA DN. AN29(jj) tt EXIST. EXIST. EXIST. NEW Sc EXIST. r NEW EXIST. NEWS EXIST. C NEW EXIS . EXIST. - - BEDR OM B DROOM EXIST. EXIST. rEA T. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. NEW BEDROOM BEDROOM EXIST. I EXIST EX ST. W.1.C. W.�'C. EXIST. EXIST. EXIST. EXIST. EXIST. < EXIST. EXIST. EXIST. EXIST. O NEW A 34,36 EGRESS LUMINATION ELECTRICAL PLAN i EGRESS IWMINATION O NEW A 34,36 _ EXIST. E'X,1- EXIST. EXIST sT. EXIST. EXIST GFI GFI O GFI zlsT: GET A W N A_ sT. 2 .FI EXIST, EXIST. GFI O O cFI cFl If H EE GAL. WA �HEA R RANGE / RANGE EXIST. _ EXIST. EXIST. NEW 33,35 NEW A 33,3 AEW31 EXIST. EXIST. EAST. NEW A-28 NEW - N / NEW NEW A-28 EXIST. KITCHEN KITCHEN - EXIST._ DINING SINK REFRIGERATOR NEW S�C EXIST. EXIST. 80 NEW REFRIGERATOR SM DINING - O0---0- - - - - - - - - - - - - - - - - - - o �J C. L C . L ----o -- 0 -- lt� � 'I 'I RTIp�P�pAFq E ANT A-2T7 ApFECI RESISTANT �r--- I O a EXIST. ELECT. u 1 EXIST. ELECT. IEXIST. PANEL EXIST. BATH. PANEL ; BATH. EXIST. II II EXIST. II II EXIST. II II II II EXIST. EXIST. EXIST. C_L ii ii C. EXIST. EXIST. EXIST. EXIST. ------ GARAGE GARAGE -------- EXIST. - ------- ____ A-28 A-28 i --- EXIST. -- i - EXIST. LIVING i I I I I LIVING EXIST. I I I I I I I I EXIST. EXIST. UP. I I I I I I I I I I I I I I I I UP. EXIST. - _ _ _ __ __ __ _ __ _ BLw LUMINATION ANEW 9 ILUMINSATION It If/-2T/t 1 8752 Southwest 143rd Street Palmetto Bay, Florida 33176 (305) 235 -7500 moraarch @ bellsouth.net J Q U W J W w J F- F m 0 w w rr ui 0 Y rr DI O z O Q 4) N t O 0 CID CV) N c J LL' U L m U Cd LL ca 5 W F- ® WI 4) ®0 Q ® ®I O e zl 00 /^a 5� ` N J IL L Q � F a DRAWN BY MVP CHECKED BY: EMM ATTACHMENT NO.. ATTACHMENT# DRAWING FILE NO.: 2017-030 DATE: 09/01/2017 SCALE. NOTED SHEETNUMBER. Fite COPY E1 OF 1 Eusebio M. Mol Architect Fla. Lic. # AR0011 SEALED CEILING PENETRA THREAD -CUTTING SCREW (TYPE F) (2) #10-32NF 04" PLENUM OC. FACTORY INSTALLED CIRCUIT BREAK -A" OD SUCTION PIPE TO C/U ON NORTH WALL, INSULATED WITH 8" R-4 PIPE INSULATION. OD LIQUID PIPE TO C/U. 0i"OD DRAIN PVC DRAIN PIPE VENT. ,j" OD DRAIN PIPE TO - SOIL AREA, 12" AWAY FROM DWELLING AND 6" ABOVE SOIL. DRAIN PUMP LITTLE GIANT MODEL VCMA-15ULS, 115 V, 65 GALS X H 0 1", 5' HP OR EQUAL. (OPTIONAL) PROVIDE A LEVEL DETECTION SWITCH TO BE INSTALLED ON THE SAFETY OVERFLOW OUTLET OF THE EQUIPMENT SUPPLIED DRAIN PAN, TO SHUT DOWN THE HVAC SYSTEM UPON DETECTION OF HIGH DRAIN LEVEL. ATTIC PROVIDE 3" CLEARANCE AROUND AIR HANDLER. EOPRENE PADS 23"W x 22"H x 23"L ALUMINUM STAND SECURE TO FLOOR SLAB THRU ANCHOR BOLTS. AIR HANDLER # (1 2) INSTALLATION DETAIL n. t. s. HVAC GENERAL NOTES 1. THE WORK TO BE DONE UNDER THIS HEADING INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS, EQUIPMENT, PERMITS, FEES, INSPECTIONS, TESTS, INSURANCE, ETC. REQUIRED FOR THE COMPLETION OF THE HVAC SYSTEM SHOWN ON DRAWINGS AND/OR LISTED BELOW. 2. THE CONTRACTOR SHALL, BEFORE SUBMITTING ANY PROPOSAL, EXAMINE THE PROPOSED SITE AND SHALL DETERMINE FOR HIMSELF THE CONDITIONS THAT MAY AFFECT THE WORK. NO ALLOWANCE SHALL BE MADE IF THE CONTRACTOR FAILS TO MAKE SUCH EXAMINATION. 3. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE FLORIDA BUILDING CODE AND ALL LOCAL CODES. 4. CONTRACTOR SHALL VERIFY SPACE CONDITIONS AND DIMENSIONS AND SHALL COORDINATE WORK WITH ALL OTHER TRADES AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF DUCTWORK AND EQUIPMENT. 5. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH PROGRESS OF CONSTRUCTION AND IN STRICT COMPLIANCE WITH ALL APPLICABLE CODES AND STANDARDS. 6. NEW DUCTWORK TO BE R-4. ALL DUCT SIZES SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. 7. VERIFY ALL VOLTAGES WITH ELECTRICAL CONTRACTOR BEFORE ORDERING ANY EQUIPMENT. 8. ALL EQUIPMENT AND MATERIALS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR. COMPRESSOR SHALL CARRY 10 YEAR FACTORY GUARANTEE. 9. VIBRATION ISOLATION: ALL EQUIPMENT AS PER MANUFACTURER'S RECOMMENDATIONS OR AS SCHEDULED ON DRAWINGS. 10. ALL OUTSIDE EQUIPMENT SHALL BE SECURED TO WITHSTAND 165 M.P.H. WINDS. 11. DO NOT SCALE THIS DRAWING FOR EXACT DIMENSIONS AT THE JOB SITE. THE MECHANICAL PLANS ARE INTENDED TO BE DIAGRAMMATIC AND ARE BASED ON ONE MANUFACTURER EQUIPMENT AND THEY ARE NOT INTENDED TO SHOW EVERY ITEM IN ITS EXACT LOCATION, THE EXACT DIMENSIONS, OR ALL THE DETAILS OF THE EQUIPMENT. THE CONTRACTOR SHALL VERIFY THE ACTUAL DIMENSION OF THE EQUIPMENT PROPOSED TO ENSURE THAT THE EQUIPMENT WILL BE FIT IN THE AVAILABLE SPACE. 12. THERMOSTAT SHALL BE LOW VOLTAGE COOL WITH FAN AND SELECTOR SWITCHES ON SUB BASE MOUNT ON WALL WHERE SHOWN ON PLANS 5'-0" ABOVE FINISHED FLOOR OR PER HANDICAP CODE REQUIREMENT. 13. PROVIDE TURNING VANES AT ALL ELBOWS =OR > 45. PROVIDE AS SHOWN (4) J" ANCHOR BOLTS OF 500 LBS MIN. PULL OUT CAPACITY ON THE BASE OF THE PAN TO PENETRATE CONCRETE 1-Y2" MIN AS PER MANUFACTURER RECOMMENDATION TO WITHSTAND 175 MPH WINDS. 4" CONC. SLAB LINES IN 6" PVC SLEEVE. n. VENTILATION FAN SCHEDULE UNIT DESIGNATION TEF-1 AREA SERVED TOILETS LOCATION CEILING FAN TYPE CEILING TOTAL AIR CFM 80 FAN WHEEL TYPE CENT. DRIVE TYPE DIRECT FAN TIP SPEED,RPM MAX - FAN SPEED,RPM - TOTAL STATIC PRESSURE,IN. OF H2O 0.10 z FAN MOTOR HP NON OVERLOAD 1.1 AMP FAN MOTOR STARTER TYPE - STARTER FURNISHED BY - ELECTRICAL SERVICE AVAILABLE 120-1-60 DESIGN MANUFACTURER NUTONE MODEL NUMBER LS 80L SERVICE SWITCH - SMOKE DETECTORS - FIRE DAMPER - CONSTRUCTION STEEL w MULTIBLADE BACKDRAFT DAMPER YES 'or BIRDSCREEN YES o CONTROL TYPE - C AUTOMATIC SHUTTER - FACTORY FABRICATED CURB - SO N ES 0.8 NOTES: 1. INTERLOCK TEF-1 WITH LIGHTS. 2. ACCEPTABLE MANUFACTURERS ARE COOK, GREENHECK OR PENN. I INSTALLATION DETAI WEATHER PROOF, 04" SHE NON -HARDENING METAL DU SILICON CAULK. GA. 26. WALL CAP ASSEMBLY TO Y WITHSTAND WITHOUT SCREEN. STAINLESS STEEL)) N­ BACKDRAFT FLAP HOSE CLAMP. ANCHORS WALL DRYER WALL CAP DETAIL nts 0 A 4" CONCRETE PAD o 0 BASE OF COMPRESSOR UNIT PROVIDE (4) J" ANCHOR BOLTS OF 500 LBS MIN. PULL OUT CAPACITY ON THE BASE OF THE PAN TO PENETRATE CONCRETE 1-)/2" MIN AS PER MANUFACTURER RECOMMENDATION TO WITHSTAND 175 MPH WINDS. RECOMMENED ANCHORS: A) 1/4" x 1-1/4" TAPCON. B) 1-1/2" PIN WITH WASHER INEW A/C EQUIPMENT SCHEDULE INDOOR UNIT - "GOODMAN" CA*F4860*6D* OUTDOOR UNIT - "GOODMAN" GSX160421F* TOTAL CAPACITY - 40,000 (BTU/H) NET SENSIBLE - 31,200 (BTU/H) SEER RATING - 15.0 INDOOR CFM - 1,310 AHU HEATER - 5.0 KW (17,060 BTU) HVAC DESIGN REQUIRES: YES NO Duct Smoke Detector Fire Damper(s) Smoke Damper(s) Fire Rated Enclosure Fire Rated RZCeiling Assembly Fire Stopping Smoke Control DRYER D(HUAST THRU WALL W( 4 DIAM. GALV. ME1 DUCT (26 GA.) C.U-UNR1 COND. DRAINFROM SECOND FLOOR (2' �NEW 141 CA - UNIT 2 2' CONE. DRAIN FROM SECOND FLOOR rS0W 14X1( N O O it I\ MOO--- ------ NEW EXIST. KITCHEN NEW EXIST. DINING KITCHEN DINING o EXIST. EXIST.d M o ----------------- O II II E ST it O it II I I XI BA H. i NEW l B TH. tIj I AHU UNff 1 II II II II NEW AHU UNR 2 II II II II II EXIST. C.L If ;; EXIST. II II CL II ------ __ I I I I EXIST. - LIVING I I I I - EXIST. i LIVING 1 I I I I I I I UP I I I I I I I I I 1 i i UP. f I I I I I I I I I I ------------- I I I I I I I\j j 8752 Southwest 143rd Stl Palmetto Bay, Florida 33 (305) 235 -75 moraarch @ bellsouth. m 0 w U) Of 1 U) Y Uj W I 7 r`, O L-W caCc Cc Q 0 OW O 0 O N Z 00 0 6- O W tL h P 93 vaill CHECKED BY: I- C) W O x a EM ATTACHMENT NO.-. ATTACHMENT DRAWING FILE NO.. 1/4� zo17-o� DATE. ;I�!]LIS�h�1y SCALE: NOTE SHEET NUMBER File Copy M1 OF 1 Eusebio M. Mora Architect Fla. Lic. # AR0011732 PLUMBING SPECIFICATIONS 1 THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT SHOWN OR INDICATED FOR A COMPLETE PLUMBING SYSTEM IN ACCORDANCE WITH THESE DRAWINGS AND WITH THE LOCAL PLUMBING AND BUILDING CODES. 2 CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL TRADES IN ORDER TO AVOID CONFLICTS. NO CHANGES WILL BE ,ACCEPTED UNLESS A PRIOR WRITTEN APPROVAL HAS BEEN ISSUED FROM THE ARCHITECT/ENGINEER. s CONTRACTOR COMPANIES IINSHALL OR ER COORDINATE VVERFY THE POINTS OF WITH CORRESPONDING UTILITY OF CONNECTION. 4 CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF ALL EQUIPMENT AND THEIR CORRESPONDING SHOP DRAWINGS BEFORE ROUGH -IN. 5 PROVIDE ALL EXCAVATION, BACKFILL AND COMPACTION REQUIRED BY ALL PLUMBING WORK. 6 PROV)DE COMPLETE ACCESS TO ALL SYSTEMS. LOCATE CLEAN -OUTS ON WALLS AND/OR FLOORS AS NECESSARY, FOR ACCESS AND OF USE PROVIDE PANELS WHERE NECESSARY FOR THE WATER DISTRIBUTION SYSTEM. 7 PLUMBING CONTRACTOR TO PROVIDE ALL FLASHING AND PITCH PANS AS REQUIRED AT ALL ROOF PENETRATIONS TO ROOFING CONTRACTOR. B BUILDING DRAINAGE SYSTEM DESIGN BASED ON 1 8" FT. MINIMUM FALL, ANY DEVIATIONS SHALL BE APPROVED BY THE ARCHITECT AND ENGINEER. 9 CONTRACTOR TO PROVIDE 1" MINIMUM WATER PIPE CAPPED AT EVERY ELECTRICAL SWITCHGRAR ROOM OR METER ROOM TO BE USED AS GROUND (IF APPLICABLE). 10ALL VALVES UNDERGROUND TO BE INSTALLED IN PROCAST CONCRETE BOXES, BROOKS OR EQUAL. 11ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND AS FOLLOWS: A SANITARY WASTE AND VENT PIPES AND FITTINGS SHALL BE PVC OR DWV (ASTM -D- 2662) B AC CONDENSATE DRAIN SHALL BE SCHEDULE 40 P.V.C. c HOT AND COOL WATER LINES SHALL BE COPPER (ASTM-B-88) TYPE "L" ABOVE GOUND. TYPE "K" UNDERGROUND. D PROVIDE DI- ELECTRIC COUPLINGS AS REQUIRED FOR CONNECTION TO DIFFERENT MATERIALS S PP HUT -OFF VALVES AT FIXTURES AND EQUIPMENT E INSULATE ALL HOT WATER LINES WITH 1/2" FIBERGLASS WITH SELF SEALING UNIVERSAL JACKET. F PLUMBING FIXTURES- AMERICAN STANDARD, KOHLER, CRANE OR EQUAL. G FLOOR AND ROOF DRAINS, IF USED, JOSAN OR EQUAL, FLOOR DRAINS SHALL BE RESEALED. H ELECTRICAL WATER HEATERS- GLASSLINED, 5 YEARS GUARANTEED A.O. SMITH OR EQUAL. VALVES - 125 PSI NIBCO SCOTT OR EQUAL. K HOSE BIBBS CHICAGO 952, OR EQUAL. L ALL EXPOSED PIPENG AT FIXTURES AND EQUIPMENT SHALL BE CHROME PLATE ESCUTCHEONS AS REQUIRED. 12 PERFORM THE FOLLOWING TESTS: A WATER PIPING SHALL BE SUBJECTED TO HYDROSTATIC PRESSURE TEST OF 100 PSG. FOR A PERIOD OF TIME SUFFICIENT TO EXAMINE ENTIRE SYSTEM BUT NOT LESS THAN ONE HOUR. B DRAINAGE PIPING - BEFORE INSTALLATION OF ANY DRAINS, THE ENDS OF SYSTEM SHALL BE CAPPED AND ALL LINES FILLED WITH WATER TO HIGHEST POINT AND ALLOWED TO STAND UNTIL INSPECTION IS MADE AND WATER LEVEL REMAINS CONSTANT. c CORRECT ALL DEFECTS DISCLOSED BY ABOVE TEST, 13 STERILIZE ALL WATER LINES WITH MIXTURE OF (2 TWO POUNDS OF CHLORINATED LIME TO EACH 1000 GALLONS OF ATER (50 PPM OF AVAILABLE CHLORINE). RETAIN MIXTURE IN PIPES 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE WATER BEFORE PLACING IN SERVICE. 14 COMPLETE SYSTEM, FIXTURES AND EQUIPMENT SHALL BE GIVEN AN IN- SERVICE TEST AFTER COMPLETION OF THE INSTALLATION. 15PLUMBING CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL PLUMBING WORK SHALL BE FREE FROM DEFECTS OF MATERIALS &WORKMANSHIP FOR A PERIOD OF ONE YEAR, FROM DATE OF FINAL ACCEPTANCE, AND THAT HE WILL, AT THIS EXPENSE REPAIR AND REPLACE ALL WORK WHICH BECOMES DEFECTIVE DURING GUARANTEE PERIOD. 16 AS PER FBCR P2708.3. SHOWER CONTROL VALVES. INDIVIDUAL SHOWER AND TUB/ SHOWER COMBINATION VALVES SHALL BE EQUIPPED WITH CONTROL VALVES OF THE PREASURE-BALANCE, THERMOSTATIC -MIXING OR COMBINATION PREASURE-BALANCI THERMOSTATIC -MIXING VALVES TYPES WITH A HIGH LIMIT STOP IN ACCORDANCE W ASSE 1016 OR CSA B125. THE HIGH LIMIT STOP SHALL BE SET TO LIMIT WATER TEMPERATURE TO A MAXIMUM OF 120 DEGREE F (49 C). IN -LINE THERMOSTATIC VALVES SHALL NOT BE USED FOR COMPLIANCE WITH THIS SECTION. AIR CHAMBER / r-- / FIXTURE CONNECTION FIXTURE W. H.W. TRAP F.U. REMARKS CONN CONN SIZE COUNT LAVATORY \" \" 1\" 2 BATHTUB \" \° A. 2 SHOWER \" \" 2" 2 WATER CLOSET (TANK) \" - 3" 3 KITCHEN SINK \" \" 1\" 2 WASHING MACHINE \" \° 2" 3 HOSE BIB \" - - - DISHWASHER - \" 1\" 2 LAUNDRY SINK \" \" 1 2 BIDET \" \" IV 2 URINAL \" \" 1\" 4 FLOOR DRAIN 2" 2 DRINKING FOUNTAIN 1 11. 1 L LAVATORY F.U. FIXTURE UNITS W.C. WATER CLOSET R.V.D. RELIEF VALVE DISCHARGE SK. SINK C.D. CONDENSATE DRAIN W.G. WATER HEATER SOIL OR WASTE LINE C.O. CLEANOUT VENT LINE V VENT INDIRECT DRAIN V.T.R. 'BENT-THRU-ROOF COLD WATER LINE W WASTE — - - — HOT WATER LINE C.W. COLD WATER CONDENSATE DRAIN F.C.O. FLUSH CLEANOUT RELIEF VALVE DISCHARGE LINE H.B. HOSE BIB w/BACK- — — HOSE BIB w/BACK FLOW PREVENTER FLOW PREVENTER & AND SHUT-OFF VALVE SHUT-OFF VALVE — — GATE VALVE D.W. DISHWASHER TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES, FIXTURE FITTINGS AND APPLIANCES PLUMBING FIXTURE MAXIMUM FLOW RATE LAVATORY, PRIVATE 1.0 GPM AT 60 PSI LAVATORY, PUBLIC, METERING 0.25 GAL. PER METERING CYCLE LAVATORY, PUBLIC 0.5 GPM AT 60 PSI SHOWER HEAD 1.5 GPM AT 80 PSI SINK FAUCET 1.0 GPM AT 60 PSI URINAL 0.5 GPM PER FLUSHING CYCLE WATER CLOSET 1.28 GAL PER FLUSHING CYCLE DISHWASHER (RESIDENTIAL) 6.5 GAL PER CYCLE OR LESS DISHWASHER (COMMERCIAL) LESS THAN 1.2 GAL PER RACK FOR FILL AND DUMP MACHINES AND LESS THAN 0.9 GAL PER RACK FOR ALL OTHER TYPES OF MACHINES UNDER COUNTER MACHINES 1.0 GAL OR LESS PER RACK FOR HIGH TEMP. MACHINES AND 1.7 GAL PER RACK FOR LOW TEMP. MACHINES WASHING MACHINE WATER FACTOR OF 8 OR LOWER HOT WA I ER - 112 3/4„ T COED WATERX GATE VALVE EXisr. 50 GAL EF. _. 92 MIN. RELIEF LINE (DISCHARGE 6" ABOVE GRADE. EXTEND LINE 12" TO THE EXTERIOR OF BUILDING WITH DISCHARGE FACING DOWN) NEW TYP. WATER HEATER LAYOUT N.T.S STUDOR VENT EACH VALVE SHALL EXISTING NB TO BE REMOVED & REPLACED - IN SAME LOCATION SHOWER CONTROL VALVES Individual shower and tub/ shower combination valves shall be equipped with control valves of the pressure -balance, thermostatic -mixing or combination pressure-balance/thermostatic-mixing valve types with a high limit stop in accordance with ASSE 1016 or ASME A112.18.1/CSA 3125.1. The high limit stop shall be set to limit the water temperature to not greater than 1207 (49°C). In -line thermostatic valves shall not be used for compliance with this section. WATER HAMMER CONTROL The flow velocity of the water distribution system shall be controlled to reduce the possibility of water hammer. Water -hammer arrestors shall be installed in accordance with the manufacturer's instalration instructions. Water hammer arrestors shall conform to ASSE 1010. ' CABINETS. CABINET EAL. TYP. LOCATION OF STUDOR VENT (A.A.V.) N.T.S NOTE: TUB COMPARTMENTS SHALL HAVE FLOORS & WALLS ( NU OR EQUAL AND CONSTRUCTED OF SMOOTH AND NONABSORBENT ATER-RESISTANT MATERIALS TO A HEIGHT OF NOT LESS THAN 72' ABOVE THE COMPARTMENT FLOOR AT THE DRAIN. (FBC R307.2) CEMENT BASED "WONDERBOARD", DUROROCK" OR APPROVED EQUAL. ON ,,3-5[B" MTL STUDS (20 Go) 016 CERAMIC T11 E GREEN EDGE SEAL MUD SET ON RIGID GALV. MTL LATH TUB TYR TUB DETAIL/ SECTION VItW N.T.S EXIST. EXIST. W.I.C. W.I.C. EXIST. EXIST. BEDROOM EXIST. BEDROOM NEW BEDROOM BEDROOM EXIST, W.I.C. EXIST. TOILET TO BE REMOVED & REPLACED EXIST. LAV./ CAB. TO BE REMOVED & REPLACED EXIST. LAV. CAB, TO BE REMOVED & REPLACED EXIST. TOILET TO BE REMOVED & REPLACED IN SAME LOCATION IN SAME LOCATION IN SAME LOCATION rIN SAME LOCATION EXIST_ EXIST_ CL. CL. EXIST. EXIST. BATH. DN. DN. BATH. EXIST. - EXIST. --- BEDROOM ---- EXIST. BEDROOM NEW BEDROOM BEDROOM EXIST. EX ST. W.I.C. VV. .C. EXIST. 4° SAN. SEWER LINE (CONT. TO VERIFY LOCATION) 3", (3 FU) II 1 EXIST - SAN. SEWER UNE /1"' . TO VERIFY LOCATION KI 3°- (3 FU; ;jii TAI101WOTAW0= • f 1/4" EXISTING TUB752 Southwest 143rd Street -& REEPLAECEmetto Bay, Florida 33176 (305) 235 -7500 moraarch @ bellsouth.net --------- O----------- - WATER HEALER 00 ` AIEROH A R __ O --- 10- ,11O- l f,(2FU) NEW NEW Y(4 U) STACK (2N EXIST. W7D (2 STACK W/D DINING ' "" 2* 3/4"C/H & NEW EXIST. KITCHEN DINING WATER ONES NEW ~ ST.�� 1IEXIST. THRU COUNG 1 KITCHEN �I CL o 1 Q -- o---- II 'I �I 1 O II O O EXIST. I I I BATH. II I I EXIST. ATER UNES WATER i EXIST. C. L THRU CEILING II Ii THRU COLIN C. L POINT OF '—lT ----------- — — IL — — - — - — - .- POINT OF ECHO& - - -I --- -- ----------------- TO CO - -- CONNECTION 3� / ,_ EXIST. WATER HEATER WATER4UCNES TO BE REMOVED EXIST. WATER HEATER TO 1 2 - H & TO BE REMOVED '- 3/4 C/H REPLACEDAND EXIST, EXIST. REPLACED ATED WWATER LINES --- -- GARAGE GARAGE — ---- EXIST.\EI LIVING I I I I I I I I UP. I I I I I I I I I I i UP. I I I I I I I I I I I I I I I I I I NOTES: is SLOPE 2" SAN. LINES 1/4" PER FT. MIN 2: SLOPE 3"& 4" SAN. LINES 1/8" PER FT. MIN 3: PROVIDE ANTI -SCALD VALVE AT TUB / SHOWER 4: PROVIDE CLEAN -OUT AT BASE OF EACH STACK 5: ALL WORK PERFORMED SHALL BE DONE IN WITH THE FBCR PLUMBING 2014 PLUMBING CODE 6: PROVIDE SHUT OFF VALVE FOR EACH H/C WATER LINES AT EACH PLUMBING FIXVRES AT CONNECTION POINT THESE PLANS, DOCUMENTS& CALCULATIONS ARE BEING PREPARED IN COMPLIANCE WITH THE FBC 2014 EDITION PLUMBING PLAN 1st FLOOR 1/4" F- - -\� WALL CLE INTERIOR PARTITION WALL CONSTRUCTION CHROME PLATED ACCESS COVER WITH CLEANOUT PLUG JOSAM 58890 SERIES. CONC. SLAB -a e 1 .tea.. .° 4°.'s SANITARY OF WASTE PIPING NOUT DETAIL PIPE SIZE WALL SIZE 2" 4" 3" 4" 4" 6" 0 Z D J CL w S- in 0 w w Of ui 0 6i Y a LU OL OL z O lU U N 00 N O O O M 03 M > _J C LL U W Cd W tz L. W ca 0 �- + M F- rQ^ O � VJ LL EW Q a ® 3 ®7® O L C L 0 CL I- w OL I 00 N p F of EL DRAWN BY MVP CHECKED BY. EMM ATTACHMENT NO.. ATTACHMENT# DRAWING FILE NO.'. 2017-030 DATE: 09/01 /2017 SCALE. NOTED SHEET NUMBER. File Copy P1 OF 1 NTS