HomeMy WebLinkAboutProduct Approval Metal RoofingFile Copy
Business eProfessionalRegulation.r
■
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts Publications FBC Staff I BCIS Site Map I Links Search
Florid
r'� Product Approval
or
� � USER: Public User
EP.:ra'.vt�.utm
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL11560-R2
Application Type
Revision
Code Version
2014
Application Status
Approved
Comments
Archived ❑
Product Manufacturer Metal Sales Manufacturing Corporation
Address/Phone/Email 545 South 3rd Street, Suite 200
Louisville, KY 40202
(812) 218-7342
dstermer@metalsales.us.com
Authorized Signature David Stermer
dstermer@meta]sales.us.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
7 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Bala Sockalingam
the Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Yoosef Lavi, P.E.
ID Validation Checklist - Hardcopy Received
Certificate of Independence FL11560 R2 COI CertificateIndeoendence.odf
Referenced Standard and Year (of Standard) Standard
TAS 125
UL 1897
UL 1897
UL 580
UL 580
Equivalence of Product Standards
Certified By
Sections from the Code
Year
2003
1998
2004
2006
1994
Florida Licensed Professional Engineer or Architect
FL11560 R2 Eauiv TestEouivalentC2009 2 3 12.odf
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method 1 Option D
03/31/2015
04/07/2015
04/12/2015
06/22/2015
FL # Model, Number or Name Description
11560.1 Aluminum 5V-Crimp 24" wide, nom 0.032" thick (min.) aluminum through
fastened roof panel over min 15/32" thick plywood deck or
7/16" thick OSB with fasteners through panel rib.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11560 R2 II Evaluation ReportC2009 I.pdf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-161.5 Evaluation Reports
Other: Uplift load of 30 psf at fastener spacing of 36" o.c. FL11560 R2 AE EvaluationReportC2009 I.Ddf
and 161.5 psf at fastener spacing of 6" o.c. Created by Independent Third Party: Yes
11560.2 Aluminum Image II 16" wide, nom 0.032" thick (min.) aluminum concealed
fastener roof panel over min 15/32" thick plywood deck or
7/16" thick OSB.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11560 R2 II Eva] uationReportC2009 2.odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-107.35 Evaluation Reports
Other: Uplift load of 22.5 psf at fastener spacing of 24" o.c. FL11560 R2 AE EvaluationReportC2009 2.pdf
and 107.35 psf at fastener spacing of 6" o.c. Created by Independent Third Party: Yes
11560.3
Aluminum Image II
16" wide, nom 0.032" thick (min.) aluminum concealed
fastener roof panel over min 19/32" thick plywood deck
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11560 R2 II Eva IuationReportC2009 3.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-195.0
Evaluation Reports
Other: Uplift load of 22.5 psf at fastener spacing of 24"
FL11560 R2 AE EvaluationReportC2009 3.pdf
o.c., 104.7 psf at fastener spacing of 6" o.c. and 195.0 psf at
Created by Independent Third Party: Yes
fastener spacing of 6" o.c. with support strap.
11560.4
Image II
Min. 26 ga., max. 16" wide standing seam roof panel over
min. 15/32" thick plywood deck
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11560 R2 II Eva luationReportC2009 4.ndf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-84.25
Evaluation Reports
Other: Uplift load of 84.25 psf at fastener spacing of 24"
FL11560 R2 AE EvaluatlonReoortC2009 4.odf
O.C.
Created by Independent Third Party: Yes
11560.5 Image II Min. 26 ga., max. 16" wide standing seam roof panel over
min. 19/32" thick plywood deck
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11560 R2 II Eva IuationReportC2009 5.pdf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-139.1 Evaluation Reports
Other: Uplift load of 84.25 psf @ fastener spacing of 24", FL11560 R2 AE EvaluationReportC2009 5.12df
102.7 psf @ fastener spacing of 6" and 139.1 psf @ fastener Created by Independent Third Party: Yes
spacing of 6" with 3/8" bead adhesive in sidelap
11560.6 I Magna-Loc I Min. 24 ga., 16" wide standing seam roof panel over plywood
deck
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11560 R2 II EvaluationReportC2009 6.Ddf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-166.0 Evaluation Reports
Other: Uplift load of 95.2 psf @ MC clip spacing of 30" o.c., FL11560 R2 AE Eva luationReoortC2009 6.1)df
Created by Independent Third Party: Yes
101.0 psf @ MC clip spacing of 15" o.c., 123.5 psf @ MC clip
spacing of 8" o.c. and 166 psf @ MPW clip spacing of 12" o.c.
111560.7 1 Magna-LOC
Limits of Use
Approved for use in HVHZ: No
Approved for -use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-168.5
Other: Uplift load of 59.7 psf @ MC clip spacing of 36" o.c.
and 168.5 psf @ MPW clip spacing of 12" o.c.
11560.8 1 Stile
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-102.7
Other: Uplift load of 85.8 psf at fastener spacing of 24" D.C.
and 102.7 psf at fastener spacing of 12" o.c.
11560.9 1 Stile
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-149.6
Other: Uplift load of 50.4 psf at fastener spacing of 36"
o.c., 106.8 psf at fastener spacing of 24" o4 and 149.6 psf
at fastener spacing of 12" o.c.
11560.10 1 Vertical Seam
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-114.25
Other: Uplift load of 30.0 psf at clip spacing of 48" o.c.,
73.0 psf at clip spacing of 24" o.c. and 114.25 psf at clip
spacing of 8" o.c.
11560.11 1 Vertical Seam
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-105
Other: Uplift load of 30.0 psf at clip spacing of 48" o.c.,
82.5 psf at clip spacing of 12" o.c. and 105.0 psf at clip
spacing of 12" o.c. with sidelap adhesive.
11560.12 1 Vertical Seam
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-81.3
Other: Uplift load of 30.0 psf at clip spacing of 48" o.c. and
81.3 psf at clip spacing of 6" o.c.
Min. 24 ga., 16" wide standing seam roof panel over steel
deck
Installation Instructions
FL11560 R2 II EvaluationReportC2009 7.pdf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
Evaluation Reports
FL11560 R2 AE Evaluation ReportC2009 7.odf
Created by Independent Third Party: Yes
Min. 26 ga., 39.4" wide through fastened roof panel over
min. 15/32" thick plywood deck
Installation Instructions
FL11560 R2 II Eva luationRepo rtC2009 8.Ddf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
Evaluation Reports
FL11560 R2 'AE Eva IUationReDOrtC2009 8.Ddf
Created by Independent Third Party: Yes
Min. 26 ga., 39.4" wide through fastened roof panel over
min. 19/32" thick plywood deck
Installation Instructions
FL11560 R2 II EvaluationReportC2009 9.pdf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
Evaluation Reports
FL11560 R2 AE EvaluationReDortC2009 9.Ddf
Created by Independent Third Party: Yes
Min 24 ga., max. 16" wide standing seam roof panel over
min. 15/32" thick plywood deck
Installation Instructions
FL11560 R2 II Evaluation ReoortC2009 10.odf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
Evaluation Reports
FL11560 R2 AE EvaluationReDortC2009 10.Ddf
Created by Independent Third Party: Yes
Min 24 ga., max. 18" wide standing seam roof panel over
min. 15/32" thick plywood deck
Installation Instructions
FL11560 R2 II EvaluationReoortC2009 11.Ddf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
Evaluation Reports
FL11560 R2 AE EvaluationReDOrtC2009 11.Ddf
Created by Independent Third Party: Yes
Min. 26 ga., 16" wide standing seam roof panel over min.
15/32" thick plywood deck
Installation Instructions
FL11560 R2 II EvaluationReoortC2009 12.Ddf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
Evaluation Reports
FL11560 R2 AE EvaluationReDOrtC2009 12.1df
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please
click here .
EVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
126 GA. IMAGE II PANEL'
FLORIDA BUILDING CODE 5TH EDITION (2014)
FLORIDA PRODUCT APPROVAL
FL 11560.5-R2
ROOFING
METAL ROOFING
Prepared For:
Metal Sales Manufacturing Corporation
545 South 3m Street, Suite 200
Louisville, KY 40202
Telephone: (502) 855-4300
Fax: (502) 855-4290
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (866) 366-1543
This report consists of
Evaluation Report (3 Pages including cover)
Installation Details (1 Page)
Report No. C2009-5
Date: 3.27.15
�01%111uu0#1i
No 62240
"fl
W
:� STATE OF : W�
Manufacturer:
Product Name:
Panel Description:
Materials:
Deck Description:
Deck Attachment:
(Minimum)
Underlayment:
Slope:
FL 11560.5-R2
C2009-5
3.27.15
Page 2 of 3
Metal Sales Manufacturing Corporation
Image 11
Max. 16" wide coverage with V high ribs
Min. 26 ,ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792) or painted steel (ASTM A755).
Min. 19/32" plywood for new and existing constructions. Designed
and installed as per FBC 2014.
8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c.
in the plywood field and edges
Minimum underlayment as per FBC 2014 Section 1507.4.5.1
2:12 or greater in accordance with FBC 2014 Section 1507.4.2
Design Uplift Pressure: 84.25 psf @ fastener spacing of 24" o.c.
(Factor of Safety =•2) 102.7 psf @ fastener spacing of 6" o.c.
139.1 psf @ fastener spacing of 6" o.c. with 3/8" bead adhesive in
panel sidelap
I
Fastener Pattern:
At panel seam #10-12 pancake head screws along panel seam. Fastener shall be of
sufficient length to penetrate through the deck a minimum of
Sidelap Adhesive: Schnee -Morehead SM7108 Permathane adhesive
Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard
Requirements for Metal Roofing Systems'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2014 Section 1507.4
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Refer to current NOA for use of this product in High
Velocity Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. "Refer . to FBC 2014 Section 1505 and current
approved roofing materials directory or ASTM E108/UL790 report
from an accredited laboratory for fire ratings of this product.
FL 11560.5-R2
C2009-5
127.15
Page 3 of 3
Supporting Documents: TAS 125 Test Reports
Farabaugh Engineering and Testing Inc
Project No. T241-07, Reporting Date 7/23/07
Hurricane Test Laboratory, LLC
HTL Report #: 0103-0714-09, Reporting Date 9/1/09
a
SEE DETAIL 1 MAX, 16" I PANEL FASTENER
ROOF PANEL r SPACING PER ALLOWABLE
/ PRESSURE TABLE.
PLYWOOD
UNDERLAYMENT SHALL BE INSTALLED
AS PER MANUFACTURER'S INSTALLATION O x 2.5" LONG RING SHANK NAIL 19/32" THICK (MIN.)
` GUIDELINES OR #8 x 2" LONG WOOD SCREWS
MIN. 2X_ WOOD RAFTER/JOIST/ SPACED ® 6" O.C. IN THE FIELD &
TRUSS AT MAX. 24" O.C. AT PLYWOOD EDGES
FASTENING PATTERN 1
SEE DETAIL 2 -�
ROOF PANEL--�
GUIDELINES — V. A
MIN. 2X- WOOD RAFTER/JOIST/ SPACED @ 6" D.C. IN THE FIELD &
TRUSS AT MAX. 24" O.C. AT PLYWOOD EDGES
. FASTENING PATTERN 2
TYPICAL PANEL INSTALLATION X-SECTION
MIN 26 GA. PANEL —
Al I nWARI F I IPI IFT PPFCSI IP17
P X 1" LONG
PANCAKE SCREWS
.DETAIL AT MAX. 6' D.C.
y
UNDERLAYMENT :f WPLYWOOD
19/32" THICK (MIN.)
SIDELAP ADHESIVE
NOM.
NOM. 3/8" BEAD
MIN 26 GA. PANEL
#10-12 X i" LONG
PANCAKE SCREWS SIDELAP ADHESIVE
DETAIL 2 AT MAX. 6" O.C.' LOCATION
t_
UNDERLAYMENT — PLYWOOD
19/32" THICK (MIN.)
PANEL FASTENER
SPACING PER ALLOWABLE
PRESSURE TABLE,
FASTENING'
PATTERN
FASTENER
SPACING
(IN)
ADHESIVE
BEAD SIZE
"
PRESSURE
(PSF)
1
24
NONE
84.25
1
6
NONE
102.7
2
6
3/8'
139.1
• SIDELAP ADHESIVE IN THE PANEL SIDElAP
GENERAL NOTES:
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE WjBC).
2. ROOF PANELS SHALL BE MIN. 26 GA (t = 0.0167'. MAX. EFFECTIVE COVERING
WIDTH OF PANEL - 16".
J. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
SPECIFIED ON THIS DRAWING.
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS
PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS
ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CODE, IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL.
6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
1 OF 1
1p
41
File Copy,