Loading...
HomeMy WebLinkAboutBoundary SurveySHEET 1 OF 2 (S7IRVEY SKETCH) ------ SURVEY NOT COMPLETE V,7T-?7UT ALL SHEETS MAP OF I' NDARY SURVEY PREPARED FOR M. SHIRIN ELEVATION NOTES: 1 0 THE BENCHMARK USED FOR THIS SURVEY'S ELEVATIONS IS NATIONAL EXISTING ELEVATION= Xeo GEODETIC SURVEY BENCHMARK "G 401" (PID - AF7490). ALL ELEVATIONS c�0.00 SHOWNARE INNAVD'88. PROPOSED ELEVATION `_ DRAINAGE ARROW=-�-�� SITE BENCHMARK ELEVATION = 20.28 (NAVD'88) o>� S89058'47"E ti�� 302.11' 2°,.��1.1p FIRC 5/8" FIR 5/8" "7025" (NO ID) ' 0 3 & �3 O 45,3 ® 3 03.2 mU Lu ^/' ^ to k N CCu 0 000 11 CONCRE7E i- LFn d�DRIVEWAY � LL- o 0 ( co U v 44.7 PARCEL ID CONCREIF m 1418 213-0010-000-3 ORNEWAY M FIRC 8 5/' WRL 7025' x� ZDD 00.0 30.1 2a i N ai N W 00.1 30.0 00 1. a o FORMBOAR o N ELEVATION = 23.8 o H NZ olq orb >� >� o •sr w . x H SITE BENCHMARK ELEVATION = 20.29 (NAVD'88) tK FIRC 5/8" N89°58'47°W 302.11' FIR 5/8" Zti4v "7025" Z V) (NO ID) W QQ p ('') w m Cti l k.D m OD J `4('M 0 CD Z e Gp FIP 1" Sfi �� `1��� (NO ID) Dad plO"ed SWALLOW LANE '(60' R/W) N NOTES: GRArHIC SCALE PROPERTYAPPEARS TO BE SERVICED BY PUBLIC UTILITIES. ALL BEARINGS AND DISTANCES SHOWNARE RECORD AND MEASURED, UNLESS OTHERWISE SHOWN. P.U.@D.E.- PUBLIC UTTUTYAND DRAINAGE EASEMENT 61 25' 50' T c)` BEARINGS ARE BASED UPON THE RECORD BEARING FOR THE WESTERLY RIGHT OF WAYLRdE OF TREE TOP TRAIL. T I �� = 50, JOB H- 1703-045 REVISION - FORM BOARD SURVEY 09/20/2017 Know 1 1+ . Now, Inc. FIELD DATE - 0312212017 REVISION - DRAWNBY-MW.S. REVISION- PROFESSIONAL SURVEYING AND MAPPING REVISION -ADD PROPOSED BUILDING 41 J2/2017 REVISION- 5220 US HIGHWAY 1, #140 VERO BEACH, FL 32967 FLORIDA BUSINESS CERTIFICATE OF AUTHORIZATION NUMBER LB 6912: Phone (772) 925-2250 SHEET 2 OF 2 (,S' 7--Y DETAILS) ------ SURVEY NOT COMPLETE WITHOUT ALL SHEETS LEGAL DESCRIPTION: JOB NUMBER: 170 THE NORTH a OF THE SOUTHEAST 4 OF THE SOUTHWEST 4 1"]/� Q .. ` `V u OF THE NORTHEAST OF THE NORTHWEST 4 OF SECTION 18, TOWNSHIP 34 SOUTH, RANGE 40 EAST, LYING IN ST. FIELD WORK DATE: 0312212017 LUCIE COUNTY, FLORIDA. PROPERTY ADDRESS: 5077 TREE TOP TRAIL, FORT PIERCE, FL 34951 FLOOD INFORMATION: PANEL NUMBER: 12111 COO 70J FIRM DATE: FEBRUARY 16, 2012 FLOOD ZONE: X BASE FLOOD ELEVATION. • NA AERIAL PHOTOGRAPH I i 1+ l SURVEYOR'S LEGEND FFE = FINSHED FLOOR ELEVATION PCC = POINT OF COMPOUND CURVATURE PIP = FOUND IRON PIPE PCP = PERMANENT CONTOL POINT A/C = AIR CONDITIONING FIPC = FOUND IRON PIPE AND CAP POB = POINT OF BEGINNING BB = BEARING BASIS FIR = FOUND IRON ROD POC = POINT OF COMMENCEMENT BFP = BACKFLOW PREVENTER FIRC = FOUND IRON ROD AND CAP PP = POOL PUMP BLDG = BUILDING FN = FOUND NAIL PRC = POINT OF REVERSE CURVATURE BLK = BLOCK FN&D = FOUND NAIL AND DISC PRM = PERMANENT REFERENCE MONUMENT BM = BENCHMARK FAD = FOUND PT = POINT OF TANGENCY C = CURVE FPK = FOUND PK NAIL R = RADIUS LINETYPES & SYMBOLS CA TV = CABLE T.V. RISER FPKD = FOUND PK NAIL AND DISC RNG = RANGE CB = CATCH BASIN FRRSPK = FOUND RAILROAD SPIKE R/W - RIGHT OF WAY = BOUNDARY LINE CL = CENTERLINE GAR = GARAGE S = SEPTIC = STRUCTURE LINE CLF = CHAIN LINK FENCE HYD = FIRE HYDRANT SEC = SECTION CLP = CONCRETE LIGHT POLE ID =IDENTIFICATION SIR = SET IRON ROD AND CAP - • • - • • - = CENTERLINE CONC = CONCRETE L = LENGTH SPKD = SET PK NAIL AND DISC _ _ - - _ = EASEMENT LINE CP = CONTROL POINT LB # = LICENSED BUSINESS SV = SEWER VALVE CPP = CONCRETE POWER POLE LS # = LICENSED SURVEYOR IBM = TEMPORARY BENCHMARK = FENCE LINE D = DEED M = MEARSURED TOB = TOP OF BANK DF = DRAINFIELD MB = MAP BOOK TWP = TOWNSHIP FIRE HYDRANT ELEV = ELEVATION MES = MITERED END SECTION TR = TELEPHONE RISER WA TER METER EM = ELECTRIC METER MH = MANHOLE TYP = TYPICAL EOW = EDGE OF WATER MLP = METAL LIGHT POLE WIT = WITNESS = POWER POLE EP = EDGE OF PAVEMENT OHW = OVERHEAD WIRES WLP = WOOD LIGHT POLE WM = WATER METER ®= WELL F = FIELD P = PLAT FCM = FOUND CONCRETE MONUMENT PB = PLAT BOOK WPP = WOOD POWER POLE FDH = FOUND DRILL HOLE PC = POINT OF CURVATURE WV = WATER VALVE = BENCHMARK SURVEYORS NOTES 1. THIS SURVEY DOES NOT DETERMINE OR'INDICATE LAND OWNERSHIP. 2. THE SURVEYOR DID NOT RESEARCH OR ABSTRACT THE LAND RECORDS FOR RIGHTS -OF WAY, EASEMENTS, RESERVATIONS, DEED RESTRICTIONS, ZONING REGULATIONS, SETBACKS, LAND USE PLAN DESIGNATIONS ADJOINING DEEDS LIENS, MURPHY ACT RIGHTS -OF -WAY, AREAS OF LOCAL CONCERN, OR OTHER SIMILAR JURISDICTIONAL DETERMINATIONS. TO THE EXTENT THAT THIS TYPE OF BVFORMA77ON IS SHOWN, IT IS SHOWN SOLELY ON THE BASIS OF INFORMATION PROVIDED BY THE CLIENT OR INFORMATION OTHERWISE KNOWN TO THE SURVEYOR AND MAY NOT BE COMPLETE. 3. UNDERGROUND UTILITIES, BUILDING FOUNDATIONS, AND OTHER UNDERGROUND FIXED IMPROVEMENTS WERE NOT LOCATED, UNLESS OTHERWISE INDICATED. TO THE EXTENT THAT THIS TYPE OF INFORMATION IS SHOWN, IT IS SHOWN SOLELY ON THE BASIS OF SURFACE INDICATIONS OBSERVED BY THE SURVEYOR AND MAY NOT BE COMPLETE. 4. JURISDICTIONAL WETLANDS AND ENDANGERED OR THREATENED SPECIES HABITAT, IF ANY, THAT MAY EXIST ON OR AROUND THE SURVEY SITE WERE NOT DETERMINED OR LOCATED. 5. THE SURVEY DATE IS THE FIELD DATE SHOWN IN THE TITLE BLOCK, NOT THE SIGNATURE DATE. 6. THIS SURVEY MAP OR THE COPIES THEREOF ARE NOT VALID WITHOUT THE SIGNATURE AND THE ELECTRONIC OR ORIGINAL RAISED SEAL OF FLORIDA LICENSED SURVEYOR AND MAPPER Z FENCES SHOWN ON SURVEY ARE FOR ILLUSTRATIVE PURPOSES ONLY. FENCE TIES SHOWN ARE RELATIVE TO THE CENTER OF SAID FENCE. THE SURVEYOR WILL NOT BE RESPONSIBLE FOR DAMAGES RESULTING FROM THE REMOVAL AND/OR CHANGES TO ANY FENCES UNLESS THE SURVEY WAS PROVIDED SPECIFICALLY FOR FENCE LOCATION PURPOSES. 8. PROPERTY LINES AND OR IMPROVEMENTS SHOWN WERE PHYSICALLY LOCATED BYFIELD SURVEY. 9. MONUMENTS FOUND OR SET ARE SHOWN, CALCULATED LINES AND INFORMATION IS NOTED BY (Q. 10. COMPUTATIONS OF LINES AND OR DATA NOT FOUND ARE SHOWNAS (C). 11. ACCURACIES OBTAINED IN THIS SURVEY IS GREATER THAN (RURAL) V IN 5000', (SUBURBAN) !'IN 7500; (COMMERCIAL) FIN 10, 000'. 12. PRIOR TO SURVEYINFORMATION OBTAINED WAS LEGAL DESCRIPTION FROM CLIENT OR FROM'PUBLICL_Y, PUBLISHED COUNTY TAX COLLECTOR SITE, RECORDED PLATS AND OR SECTION CORNER RECORDS IF APPLICABLE. 13. IF ONLY A DIGITAL SURVEY COPYIS REQUIRED A SURVEYREPORT WILL BE PLACED IN FILE. THE DIGITAL SURVEYS NOT,F,ULL AND COMPLETE WITHOUT THE SURVEY REPORT FILE. SURVEYOR'S .SIGNATURE ' CERTIFIED TO: NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED SEAL OR ELECTRONIC SEAL OF THE M. SHIRIN FLORIDA LICENSED SURVEYOR BELOW. THE SURVEYOR HEREBY CERTIFIES THAT THE ELECTRONIC ,ILL SIGNATURE AND SEAL HEREON MEETS PROCEDURES SET FORTH IN CHAPTER Si-17.062 OF THE FLORIDA ADMINISTATIVE CODE, PURSUANT TO SECTION 472.025, FLORIDA STATUTES. THE SURVEYOR HEREBY CERTIFIES THAT THIS SURVEY MEETS THE MINIMUM TECHNICAL STANDARDS FOR SURVEYS, SET FORTH BY THE FLORIDA BOARD OF SURVEYORS AND MAPPERS IN CHAPTER 5J-17.051 AND 5J-17.052 OF THE FLORIDA ADMINISTRATIVE CODE, PURSUANT TO SECTION 472.027, FLORIDA STATUTES. BILLHYATT: DATE Know It, NOW, Inc. SURVEYOR AND MAPPER #4636 PROFESSIONAL SURVEYING AND MAPPING STATE OFFLORIDA 5220 US HIGHWAY 1, #140 VERO BEACH, FL 32967 Phone (772) ,.925-2250 FLORIDA BUSINESS CERTIFICATE OF AUTHORIZATION NUMBER LB 6912