HomeMy WebLinkAboutProduct Approval & Evaluation Report Roofing Tiles%On1OA OQPAQM3M OF
Business & Professional Regulation
BCIS Home I Log In I User Registration I Hot Topics
db
a
l :: J Product Approval
USER: Public User
j lit "
Submit Surcharge Stats & Facts I Publications I FBC Staff I BCIS Site Map I Links I Search
File Copy
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL7804-R9
Application Type
Revision
Code Version
2014
Application Status
Approved
Comments
Archived ❑
Product Manufacturer lEn, te ra Roof Tile Inc.
Address/Phone/Email 1289 NE 9th Avenue
Okeechobee, FL 34972
(863) 467-0042 Ext 1228
tjohnson@rooftile.com
Authorized Signature Terry Johnson
tjohnson@rooftile.com
Technical Representative Jim Deyarmond
Address/Phone/Email 1289 NE 9th Avenue
Okeechobee, FL 34972
(863)467-0042
JDeyarmond@rooftile.com
Quality Assurance Representative Terry Johnson
Address/Phone/Email 819 South Federal Hwy Suite 300
Stuart, FL 34994
(800) 586-7663
tjohnson@rooftile.com
Category Roofing
Subcategory Roofing Tiles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 11/04/2017
Validated By John W. Knezevich, PE
0 Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL7804 R9 COI 2016 01 COI Nieminen.odf
Standard
Year
ASTM C1492
2003
FRSA/TRI April 2012
2012
SSTD 11
1997
TAS 100
1995
TAS 101
1995
TAS 102
1995
TAS 102(A)
1995
TAS 112
1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
04/19/2016
Date Validated
04/20/2016
Date Pending FBC Approval
04/24/2016
Date Approved
06/08/2016
Summary of Products
FL #
Model, Number or Name
Description
7804.1
Entegra COnCriete Roof Tiiles (IHUHLZ
Concrete Roof Tile
jurisdictions)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: No
FL17.804 R9 II 2016 04 FINAL ER ENTEGRA FL7BE7
R9 FiUH2.pdfa
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use. Refer to ER
Evaluation Reports
Section 6 for Installation.
FL7804 R9 AE 2016 04 FINAL ER ENTEGRA FL7804-
R9 HVHZ.pdf
Created by Independent Third Party: Yes
7804.2
Entegra Concrete Roof Tiles (non-
Concrete Roof Tile
HVHZ jurisdictions)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL7804 R9 II 2016 04 FINAL ER ENTEGRA FL7804-
R9 NON-HVHZ.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use. Refer to ER
Evaluation Reports
Section 6 for Installation.
FL7804 R9 AE 2016 04 FINAL ER ENTEGRA FL7804-
R9 NON-HVHZ.odf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
® ® ® acted
Credit Card
Safe
C)o
-,l TRINITY ERD
EVALUATION REPORT
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
lll� A Entegra Roof Tile, LLC Evaluation Report E39310.11.11-1-R3
rNTEGR 1 1289 NE 9" Avenue FL7804-1119
R O O F T I L E Okeechobee, FL 34972 Date of Issuance: 11/02/2011
Revision 3: 04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
(HVHZ) sections noted herein.
DESCRIPTION:
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nleminen,
P.E. on 04/18/2016. This does not serve as an electronically signed
document. Signed, sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity) ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
QOTRINITYIERD
ROOFING SYSTEM EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Tiles
Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section
Property
Standard
Year
1523.6.5.2
Physical Properties
TAS 112
1995
1523.6.5.2
Wind Driven Rain
TAS 100
1995
1523.6.5.2.2
Static Uplift Resistance
TAS 101
1995
1523.6.5.2.3
Static Uplift Resistance
TAS 102
1995
1523.6.5.2.3
Static Uplift Resistance
TAS 102(A)
1995
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST6049)
TAS 101
P39740.02.12
02/21/2012
ATL (TST3782)
Physical Properties
RT0624.05-14
07/03/2014
ATL (TST3782)
Physical Properties
RT0624.04-14
07/07/2014
ATL (TST3782)
Physical Properties
RT1210.02-15
12/17/2015
ATL (TST3782)
Physical Properties
RT1210.03-15
12/17/2015
ATL (TST 3782)
Physical Properties
RT1103.01-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.02-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.03-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.04-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.05-15
11/07/2015
Miami -Dade (CER1592)
HVHZ Compliance
14-0416.12
11/27/2014
Miami -Dade (CER1592)
HVHZ Compliance
15-0721.04
11/05/2015
Miami -Dade (CER1592)
HVHZ Compliance
16-0112.06
02/25/2016
Miami -Dade (CER1592)
HVHZ Compliance
16-0112.07
02/25/2016
Miami -Dade (CER1592)
HVHZ Compliance
16-0112.08
02/25/2016
Tile Roof Institute
TAS 100, TAS 101, 102, 102(A)
Membership Confirmation
Current
PRI (QUA9110)
Quality Assurance
Inspection Report
11/04/2015
Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-113
Certificate of Authorization #9503 F1.7804-119
Revision 3: 04/18/2016
Page 2 of 9
(-)0-
"QTRINITYIERD
4.2 BELLA HIGH "S" are TAS 112, Type 1a (interlocking, high -profile) concrete roof tiles.
Bella High "S"
4.3 ESTATE 5 and HACIENDA are TAS 112, T e 1b linter oc -in , low- ro i a concrete roo tiles.
Estate S
Hacienda
Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R3
Certificate of Authorization #9503 FL7804-R9
Revision 3: 04/18/2016
Page 4 of 9
QOTRINITYIERD
4.4 GALENA SPANISH "S" and REGAL are TAS 112, Type 2a (non -interlocking, high -profile) concrete roof tiles.
17"
Galena Spanish "S"
10"
Regal
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or other jurisdictions adopting FBC HVHZ
requirements.
5.3 Fire classification is not part of this evaluation; refer to FBC Section 1516 or current Approved Roofing
Materials Directory for fire rating of this product.
5.4 Reference is made to FBC Section 1512.4.2.4 regarding field testing of completed tile roof installations.
5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in
accordance with TAS 112, Appendix 'A'. Such testing shall be submitted to Trinity) ERD for review.
5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment
products shall hold Florida Statewide Product Approval or Local Approval for use in tile roof assemblies in
HVHZ jurisdictions.
5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements.
5.8 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C. Rule 61G20-3.
Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R3
Certificate of Authorization #9503 FL7804-119
Revision 3: 04/18/2016
Page 5 of 9
(_)0
V TRINITY ERD
6. INSTALLATION:
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall
comply with manufacturer's current published instructions, but not less than the requirements of RAS 118,
RAS 119 or RAS 120, as applicable.
6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in
accordance with RAS 127-11 using the data outlined herein.
TABLE 1: AERODYNAMIC MULTIPLIER
Tile
Batten Application
Direct -Deck Application
Bermuda Flat
0.189
0.205
Plantation Flat
0.267
0.289
Horizon Flat
0.305
0.330
Bella High "S"
0.349
0.378
Estate S
0.267
0.289
Hacienda
0.267
0.289
Galena Spanish "S"
N/A
0.235
Regal
0.287
0.311
TABLE 2: RESTORING MOMENT DUE TO GRAVITYY M.)FT-LBF)
Roof Slope (0)
Tile
2:12 < 0 < 3:12
3:12 < 0 < 4:12
4:12 < 0 < 5:12
5:12 < 0 < 6:12
6r12 < < 7:12
0 > 7:12
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Bermuda Flat
5.22
6.43
5.17
6.37
5.09
6.27
4.98
6.15
4.86
6.00
4.72
5.83
Plantation Flat
7.22
7.91
6.85
7.79
6.75
7.67
6.61
7.52
6.44
7.32
6.26
7.04
Horizon
7.60
8.32
7.52
8.24
7.41
8.12
7.26
7.95
7.09
7.76
6.89
7.55
Bella High "S"
6.19
6.89
6.11
6.80
5.99,
6.67
5.85
6.51
5.68
6.33
5.50
6.13
state
6.14
6.84
5.91
6.74
5.82
6.64
5.70
6.50
5.56
M
5.40
6.14
Hacienda
5.92
6.80
5.92
6.80
5.82
6.69
5.70
6.55
5.56
6.39
5.41
6.22
Galena Spanish "S"
N/A
6.20,
N/A
6.13
N/A
6.03
N/A
5.89
N/A
5.74
N/A
5.57
Regal
7.77
8.34
7.77
8.34
7.65
8.20
7.49
8.03
7.30
7.83
7.10
7.61
Exterior Research and Design, LLC. Evaluation Report E39330.11.31-1-R3
Certificate of Authorization #9503 FL7804-119
Revision 3: 04/18/2016
Page 6 of 9
QOTRINITYIERD
TABLE 3A-1: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT- MF. (FT-LBF)
FLAT PROFILE TILES, MECHANICALLY ATTACHED SYSTEMS
Tile
Fastener
Direct -Deck
(min.15/32"
plywood)
Direct -Deck
(min.19/32"
plywood)
Battens
Type
#
Size
Shank
Clip
Nail
One (1)
10d
Smooth or Screw
N/A
7.3
9.8
4.9
Nail
Two (2)
10d
Smooth or Screw
N/A
14.0
18.8
7.4
Nail
One (1)
10d
Smooth or Screw
Eave
19.0
19.0
22.1
Nail
One (1)
10d
Smooth or Screw
Field
24.3
24.3
24.2
Bermuda Flat,
Nail
Two (2)
10d
Smooth or Screw
Eave
31.9
31.9
32.2
Plantation Flat or
Nail
Two (2)
10d
Smooth or Screw
Field
35.5
35.5
34.8
Horizon
Nail
Two (2)
10d
Ring
N/A
30.9
38.1
17.2
Nail'
Two (2)1
10d'
Ring'
N/A
50.3'
65.51
48.31
Screw
One (1)
#8
N/A
N/A
30.8
30.8
18.2
[�crew
Two (2)
#8
N/A
N/A
51.7
51.7
24.4
1lnstallation with a 4-inch the headlap and fasteners located min. 2'/:-inch from head of tile.
TABLE 3A-2: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT- MF (FT-LBF)
FLAT PROFILE TILES, ADHESIVE -SET SYSTEMS
Tile
Application
Adhesive
Size (inch)
Weight (g)
Mf (ft-lbf)
To
Substrate
To Tile
To
Substrate
To Tile
Bermuda Flat,
Plantation Flat or
Horizon
Inter -
Dependent
TILE BOND'"'
1 x 6
1 x 6
-11
-11
40.6
Touch 'n Seal- StormBond
1.25 x 10
1.25 x 8
-8.3
-10.2
73.2
ICP Adhesives Polyset RTA-1;
cross -bond
-5" long
oblong
-4.5"
across head
-9
-5
51.8
ICP Adhesives Polyset AH-160
4 x 4
2 x 4
-16
-8
42.8
Independent
ICP Adhesives Polyset AH-160
2 x 7
N/A
-30
N/A
50.9
2 x 10
N/A'
-45
N/A
91.9
TABLE 3B-1; ATTACHMENT RESISTANCE EXPRESSED AS A,MOMENT- MF (FT-LBF)
LOW PROFILE TILES, MECHANICALLY ATTACHED SYSTEMS
Tile
Fastener
Q�rect.Dec
(Utr- ectrDe_ck_�
Battens
Type
#
Size
Shank
Clip
0o
o0
Nail
One (1)2
10d
Smooth or Screw
N/A
8.81
11.8'
4.12
Nail
Two (2)
10d
Smooth or Screw
N/A
16.4
21.9
7.1
Nail
One (1)2
10d
Smooth or Screw
Eave
1 19.02
19.0,
22.12
Nail
One (1) Z
10d
Smooth or Screw
Field
24.3 Z
24.3 z
24.2'
Nail
Two (2)
10d
Smooth or Screw
Eave
31.9
31.9
32.2
Nail
Two (2)
10d
Smooth or Screw
Field
35.5
35.5
34.8
Estate S or Hacienda
Nail
Two (2)
10d
Ring
N/A
27.8
37.4
28.8
Nail'
Two (2)1
10d'
Ring'
N/A
43.01
67.5'
50.91
Screw
One (1) z
#8
N/A
N/A
25.81
25.8 Z
22.9 Z
crew
wo 2
®
N A
I
47.1
7.1
49.1
' Installation with a 4-inch tile headlap and fasteners located min. 2Y.-inch from head of tile.
1 For one (1) fastener installations, utilize hole that is approximately 4%-inch from the interlocking edge.
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503
Evaluation Report E39310.11.11-1-R3
FL7804-R9
Revision 3: 04/18/2026
Page 7 of 9
�I TRINITY IERD
7. LABELING:
7.1 Each unit -shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed
`-below. Tile"lots.shall be labeled in accordance with the requirements of the Accredited Quality Assurance
Agency noted herein.
and/or
NT R R
Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S"
Hanson
Labeling: Horizon Flat, Hacienda, Regal
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Plant
Profiles
Okeechobee, FL
Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S"
Ft. Myers, FL
Horizon Flat, Hacienda
Deerfield Beach, FL
Horizon Flat, Hacienda, Regal
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies, LLC. — QUA9110; (813) 621-5777
- END OF EVALUATION REPORT —
Exterior Research and Design, LLC. Evaluation Report E39310.11.11-1-R3
Certificate of Authorization #9503 FL7804-119
Revision 3: 04/18/2016
Page 9 of 9