HomeMy WebLinkAboutAPPROVED A101 - COVER SHEET- 01-2022LOBBY
101
WOMEN
115
MEN
114
GENERAL
MANAGER
113
IT ROOM
112
BREAKROOM
111
OFFICE 1
109
PARTS MGR
108
SALES
102
SALES
103
SERVICE MGR
104
SERVICE WRITER
105
DRIVER'S
LOUNGE
106
OFFICE MGR
107
CORRIDOR
117
CORRIDOR
116
PARTS
SHOWROOM
118
TECH'S
RESTROOM
121
OFFICE
120
1985 SF
WAREHOUSE
122
SERVICE BAY 1
123
SERVICE BAY 2
124
SERVICE BAY 3
125
SERVICE BAY 4
126
SERVICE BAY 5
127
SERVICE BAY 15
136
SERVICE BAY 14
135
SERVICE BAY 13
134
SERVICE BAY 12
133
SERVICE BAY 11
132 SERVICE BAY 10
131 SERVICE BAY 9
130
SERVICE BAY 8
129
SERVICE BAY 7
128
OPEN OFFICE
110
IT RACK
PARTS COUNTER
119
USED OIL AREA
137
NO WORK IN SERVICE BAYS
NO WORK IN WAREHOUSE (OPEN TO ELEMENTS)
WORK AREA
B
S-1
S-1
9.
A. EXIT ENCLOSURE AND EXIT PASSAGEWAY
B. CORRIDORS
C. ROOMS AND ENCLOSED SPACES
11.REQUIRED FIRE RATINGS
INTERIOR FINISHES RATING-NEW FINISHES IN BUSINESS OCCUPANCY-NO WORK IN S-1
CHAPTER 8-FBC
BUILDING FLOOR AREA ALLOWED PER FLOOR (IBC TABLE 503)-PER EXISTING CONDITIONS
TYPE OF CONSTRUCTION-PER EXISTING CONDITIONS
OCCUPANT LOAD (FBC SECT. 1004 & TABLE 1004.5) =
PRIMARY OCCUPANCY CLASSIFICATION (FBC CHAPTER 3)
FLOOR ALLOWED-S-1
BUILDING NON-SPRINKLERED
INTERIOR RENOVATION-LEVEL 2-
4.
3.
2.
1.
PROJECT DESIGNED IN ACCORDANCE WITH:
FBC V B
S-1/ B
IMC -INTERNATIONAL MECHANICAL CODE
FLORIDA FIRE PREVENTION CODE
FLORIDA EXISTING BUILDING CODE
FLORIDA BUILDING CODE 2020 (7th EDITION)
A. SEPARATION BETWEEN OCCUPANCIES
REQUIRED SEPARATION OF OCCUPANCIES-PER EXISTING CONSTRUCTION5.
A. CORRIDORS 0 HR ( NO CORRIDOR EXCEEDS MORE THAN 30 PEOPLE)
9,000 SF
SEPARATION BUSINESS GROUP
EXISTING BUSINESS AREA = 4,346 SF GROSS EXISTING STORAGE-1 AREA = 11,189 SF GROSS
TOTAL BUSINESS OCCUPANCY= 29 PEOPLE
A
B
C
FLORIDA PLUMBING CODE
2020 (7TH EDITION)
FLORIDA FUEL GAS CODE
NATIONAL ELECTRIC CODE 2017 EDITION
FLORIDA BUILDING CODE- ENERGY CONSERVATION
2020 (7TH EDITION)
EXISTING FLOOR-S-1 8,986 SF
FLOOR ALLOWED-B 9,000 SF
4,346 SFEXISTING FLOOR-B
FBC 2 HR
2020 (7TH EDITION)
2020 (7TH EDITION)
2020 (7TH EDITION)
2020 (7TH EDITION)
TOTAL SQUARE FOOTAGE OF EXISTING BUILDING= 15,600 SF
WORK AREA (BUSINESS) = 4,346 SF (28% OF BUILDING TOTAL)
4,346 SF GROSS @ 150 GROSS= 29 PEOPLE WAREHOUSE 2,250 SF GROSS @ 500 GROSS= 4 PEOPLE
PARKING GARAGES 8,939SF GROSS @ 200 GROSS= 45 PEOPLE
TOTAL S-1 OCCUPANCY= 45 PEOPLE
EXISTING STRUCTURE BUILT IN 1996. EXTERIOR WALLS= 8"CMU, INTERIOR PARTITIONS 2X4 WOOD FRAMING
NO EXTERIOR WORK TO BE PERFORMED, NO ROOF ALTERATIONS OR REPLACEMENT, NO STRUCTURAL
COMPONENTS TO BE MODIFIED OR REWORKED.CADFILE: 24x36DRAWN BY:
CHECKED BY:L I L I A N A R. T O B O NAIA, LEED AP, NCARBSCALE
DATE:
REV.A r c h i t e c t3512 PRESTO N TRAIL M ARTINEZ, G A 30907TEL (706) 288-8273LTO BO N@ THEPETESTO RE.CO M1/4/2022 12:38:07 PMC:\Users\Liliana Tobon\Dropbox (The Pete Store)\LILIANA'S FILES\The Pete Store- 28- Fort Pierce, FL\existing drawings\FortPierce, FL- Existing OPT2.rvtAs indicated
LTOBON
Checker
JAN 3, 2022
22-001
A101
COVER SHEETINTERIOR RENOVATIONPALM WAY INVESTMENTS, LLC5750 ORANGE AVENUE FORT PIERCE, FL 34947PROJECT DIRECTORY
ARCHITECT:
LILIANA TOBON, AIA
THE PETE STORE, LLC
706-288-8273
LTOBON@THEPETESTORE.COM
OWNER:
PALM WAY INVESTMENTS, LLC
582 PALM WAY
GULF STREAM, FL 33483
MECHANICAL ENGINEER
FORT PIERCE ENGINEERING, INC
315 SOUTH 7TH STREET
FORT PIERCE, FL 34950
(772) 672-4636
PLUMBING ENGINEER
FORT PIERCE ENGINEERING, INC
315 SOUTH 7TH STREET
FORT PIERCE, FL 34950
(772) 672-4636
FIRE PROTECTION ENGINEER
N/A
ELECTRICAL ENGINEER
FORT PIERCE ENGINEERING, INC
315 SOUTH 7TH STREET
FORT PIERCE, FL 34950
(772) 672-4636
CIVIL ENGINEER
N/A
STRUCTURAL ENGINEER
N/A
PROJECT LOCATION
INTERIOR RENOVATION
THE PETERBILT STORE
5750 ORANGE AVENUE FORT PIERCE, FLORIDA 34947
CODE ANALYSIS DRAWING LIST
ARCHITECTURAL
A101-COVER SHEET
LS101-LIFE SAFETY PLAN
A102-DEMOLITION PLAN
A201-NEW FLOOR PLAN
A301-REFLECTED CEILING PLAN
A801-INTERIOR ELEVATIONS-MILLWORK
ID201-INTERIOR FINISHES/ FURNITURE
ID202-FLOORING PLAN
MECHANICAL
M1.0-HVAC GENERAL NOTES, SYMBOLS & SCHEDULES
M2.1-HVAC DEMO PLAN
M2.2-HVAC PLAN
M3.1-MECHANICAL DETAILS
PLUMBING
P1.0-PLUMBING LEGEND, NOTES , SCHEDULE & DETAILS
P2.1-PLUMBING PLAN
P2.2-PLUMBING PLAN
P3.1-PLUMBING WASTE-VENT & WATER RISERS
ELECTRICAL
E1.0-ELECTRICAL LEGEND, SPECIFICATIONS & ABBREVIATIONS
E2.1-ELECTRICAL POWER, SYSTEMS, DEMOLITION PLAN
E2.2-ELECTRICAL POWER SYSTEMS, NEW WORK PLAN
E3.1-LIGHTING PLAN AND LIGHTING FIXTURE SCHEDULE
E4.1-PANEL SCHEDULES, RISER, DETAILS AND CALCULATIONS
REVDATEBYD E S C R I P T I O N