HomeMy WebLinkAboutAPPROVED A102 - DEMOLITION PLAN- 01-2022ROLL-UP FIRE DOORIT RACK
REMOVE EXIST.
CARPET
REMOVE
EXISTING
CARPET
REMOVE EXIST.
TILE
REMOVE EXIST.
TILE AND
LAMINATED
FLOOR
REMOVE
EXISTING
RECEPTION
DESK
REMOVE EXIST.
CABINETS IN
ROOM
REMOVE
EXISTING
CARPET
REMOVE
EXISTING
TILE
REMOVE
EXISTING
CARPET
REMOVE
EXISTING
CARPET
REMOVE
EXISTING
PLUMBING
FIXTURE
REMOVE EXISTING
PLUMBING
FIXTURES,
ACCESSORIES,
DOORS, FLOOR AND
WALL TILE
REMOVE
EXISTING
PLUMBING
FIXTURES,
ACCESSORIES,
DOORS, FLOOR
AND WALL TILE
REMOVE EXISTING
CARPET
REMOVE EXISTING
CARPET
REMOVE
EXISTING
STOREFRONT
DOOR
REMOVE
EXISTING
ROLL-UP
DOOR
REMOVE EXISTING LOCKERS
REMOVE
EXISTING
WINDOWS
REMOVE
EXISTING
COUNTER
REMOVE
EXISTING
COUNTER
NO WORK ON THIS AREA
REMOVE EXIST.
CABINETS AND
PLUMB. FIXTURES
REMOVE
EXISTING
TILE
REMOVE EXISTING PLUMBING
FIXTURES, AND ACCESSORIES.
REMOVE
EXISTING
WINDOWS
REMOVE
EXISTING
WINDOWS
EXISTING FIRE BARRIER2HR RATED CMU WALL-UL U905EXISTING 2HR
RATED CMU
WALL-
UL U905EXISTING FIRE BARRIER2HR RATED CMU WALL-UL U905EXISTING FIRE BARRIER2HR RATED CMU WALL-UL U905EXISTING FIRE BARRIER2HR RATED CMU WALL-UL U90590 MIN DOOR W/
SELF CLOSER
90 MIN DOOR W/ SELF
CLOSER
90 MIN DOOR W/
SELF CLOSER
90 MIN DOOR W/
SELF CLOSER
90 MIN DOOR W/
SELF CLOSER
EXIST. STAIR
TO MEZZANINE
REMOVE
EXISTING
WINDOWS
REMOVE
EXISTING
DOOR AND
FRAME
LOBBY
101
WOMEN
115
MEN
114
GENERAL
MANAGER
113
IT ROOM
112
BREAKROOM
111
OFFICE 1
109
PARTS MGR
108
SALES
102
SALES
103
SERVICE MGR
104 SERVICE WRITER
105
DRIVER'S
LOUNGE
106
OFFICE MGR
107
CORRIDOR
117
CORRIDOR
116
PARTS
SHOWROOM
118
TECH'S
RESTROOM
121
OFFICE
120
WAREHOUSE
122
OPEN OFFICE
110
PARTS COUNTER
119
GENERAL DEMOLITION NOTES
THE PURPOSE OF THESE DEMOLITION PLANS, AS MADE PART OF THE CONTRACT DOCUMENTS, IS TO GIVE THE GENERAL
CONTRACTOR A GENERAL IDEA AS TO THE SCOPE OF ARCHITECTURAL DEMOLITION WORK REQUIRED. THESE DRAWINGS
ARE NOT MEANT TO IDENTIFY ALL DEMOLITION WORK REQUIRED, NOR DO THEY ACCURATELY REFLECT ALL EXISTING
CONDITIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE FACILITY, THOROUGHLY EVALUATE AND COMPARE
THE OWNER'S RECORD SET OF DRAWINGS IF AVAILABLE,OF THE EXISTING FACILITY AGAINST THESE DRAWINGS & ACTUAL
SITE CONDITIONS, AND REVIEW ALL CONTRACT DOCUMENTS TO ARRIVE AT THE SCOPE OF DEMOLITION WORK REQUIRED
TO ACHIEVE THE INTENDED RESULTS AND FINISHED PRODUCT.
ALL EXISTING SERVICE UTILITY LINES IN RENOVATED AREAS ARE TO TIE-IN INTO NEW SERVICE LINES OR ARE TO BE
TERMINATED AND CAPPED OFF AS REQUIRED. TERMINATE OR OTHERWISE CAP OFF ALL ABANDONED UTILITIES
BEHIND FINISH WALL SURFACES OR BELOW FLOOR SLABS.
ALL CONCRETE, MASONRY, TILE AND PLASTER SURFACES INDICATED TO BE CUT AND PATCHED OR ARE ON A SURFACE
IN WHICH A DOOR, WINDOW, OR PORTION OF THE SURFACE IS TO BE REMOVED, SHALL BE CUT WITH MASONRY SAWS
OR SCORED FOR CLEAN JOINTS AND PATCHED FLUSH TO RECEIVE NEW MATCHING MATERIALS AND FINISHES.
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE REGULAR REMOVAL OF ALL WASTE MATERIAL
FROM THE PROJECT SITE AS IT PERTAINS TO THE RENOVATION ACTIVITIES, AND ALL AREAS USED BY BUILDING
PERSONNEL SHALL BE KEPT CLEAN. IN LOCATIONS WHERE EXISTING WALLS ARE REMOVED, PATCH ADJACENT
WALLS AS REQUIRED WITH MATERIALS AND FINISHES TO MATCH EXISTING OR AS SCHEDULED BY THE DRAWINGS.
ALL ABANDONED OR REMOVED ELECTRICAL OUTLETS, LIGHT SWITCHES AND RELATED WALL OR CEILING
BOXES SHALL HAVE ALL WIRE REMOVED COMPLETELY BACK TO THE ELECTRICAL PANEL. SOLID OUTLET
COVERS MAY BE USED OVER THE ABANDONED SWITCHES OR OUTLETS PROVIDED. THESE ARE TO BE
LOCATED NO LESS THAN 6" FROM AN ADJACENT WALL OR FIXTURE. IF MORE THAN 6", THE CONTRACTOR
SHALL REMOVE THE BOX AND PATCH THE HOLE TO MATCH NEW FINISHES. ALL CEILING BOXES ABANDONED
SHALL BE REMOVED-IF REQUIRED.
THROUGHOUT ENTIRE PROJECT AREA: COMPLETELY REMOVE ALL PLUMBING FIXTURES AND ASSOCIATED
WATER & WASTE PIPING, ALL FLOOR DRAINS AND CAP LINES. REFER TO PLUMBING DRAWINGS FOR SPECIFIC
NOTES.THROUGHOUT ENTIRE PROJECT AREA: COMPLETELY REMOVE ALL FLOORINGS TO THE SUBSTRATE. EXPOSED
SUBSTRATES ARE TO BE GROUND CLEAN OR OTHERWISE PREPARED TO RECEIVE NEW FINISHES. ABANDONED
FLOOR DRAINS ARE TO BE REMOVED. LEVEL DEPRESSIONS TO ADJACENT FLOOR SLAB ELEVATIONS WITH THE
SPECIFIED LEVELING COMPOUND.
COMPLETELY REMOVE ALL CEILING GRID, TILE, LIGHTS, MECHANICAL DIFFUSERS AND EXIT SIGNS (REMOVE
ASSOCIATED CEILING SUPPORTED ITEMS.)
ALL OTHER COMPONENTS OF THE EXISTING CONSTRUCTION, NOT ESSENTIAL TO REMAIN, THAT WOULD
INTERFERE WITH THE INSTALLATION OF NEW WORK OR INTERFERE WITH THE INSTALLATION OF NEW FLUSH,
UNBROKEN PLUMB AND LEVEL WALL, CEILING, AND FLOOR SURFACES SHALL BE REMOVED.
REMOVE EXISTING SHELVING, COUNTERTOPS, CASE WORK ETC. WITH RELATED TRIM, BLOCKING, FASTENERS,
PLUMBING, AND ELECTRICAL. CAP ALL PIPING NOTED TO BE REMOVED AS PER PLUMBING DRAWINGS AND SPECS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY WALL AND/ OR FLOOR SURFACES
BEHIND OR UNDER OBJECTS THAT ARE TO BE REMOVED. THE WORK IS TO INCLUDE BUT NOT LIMITED TO
INSTALLING NEW GYP. BD., FLOORING AND PAINTING.
CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A SMOOTH LEVEL SURFACE IN ALL AREAS OF RENOVATION.CADFILE: 24x36DRAWN BY:
CHECKED BY:L I L I A N A R. T O B O NAIA, LEED AP, NCARBSCALE
DATE:
REV.A r c h i t e c t3512 PRESTO N TRAIL M ARTINEZ, G A 30907TEL (706) 288-8273LTO BO N@ THEPETESTO RE.CO M1/4/2022 12:33:21 PMC:\Users\Liliana Tobon\Dropbox (The Pete Store)\LILIANA'S FILES\The Pete Store- 28- Fort Pierce, FL\existing drawings\FortPierce, FL- Existing OPT2.rvtAs indicated
Author
Checker
JAN 3, 2022
22-001
A102
DEMOLITION