Loading...
HomeMy WebLinkAboutAPPROVED A102 - DEMOLITION PLAN- 01-2022ROLL-UP FIRE DOORIT RACK REMOVE EXIST. CARPET REMOVE EXISTING CARPET REMOVE EXIST. TILE REMOVE EXIST. TILE AND LAMINATED FLOOR REMOVE EXISTING RECEPTION DESK REMOVE EXIST. CABINETS IN ROOM REMOVE EXISTING CARPET REMOVE EXISTING TILE REMOVE EXISTING CARPET REMOVE EXISTING CARPET REMOVE EXISTING PLUMBING FIXTURE REMOVE EXISTING PLUMBING FIXTURES, ACCESSORIES, DOORS, FLOOR AND WALL TILE REMOVE EXISTING PLUMBING FIXTURES, ACCESSORIES, DOORS, FLOOR AND WALL TILE REMOVE EXISTING CARPET REMOVE EXISTING CARPET REMOVE EXISTING STOREFRONT DOOR REMOVE EXISTING ROLL-UP DOOR REMOVE EXISTING LOCKERS REMOVE EXISTING WINDOWS REMOVE EXISTING COUNTER REMOVE EXISTING COUNTER NO WORK ON THIS AREA REMOVE EXIST. CABINETS AND PLUMB. FIXTURES REMOVE EXISTING TILE REMOVE EXISTING PLUMBING FIXTURES, AND ACCESSORIES. REMOVE EXISTING WINDOWS REMOVE EXISTING WINDOWS EXISTING FIRE BARRIER2HR RATED CMU WALL-UL U905EXISTING 2HR RATED CMU WALL- UL U905EXISTING FIRE BARRIER2HR RATED CMU WALL-UL U905EXISTING FIRE BARRIER2HR RATED CMU WALL-UL U905EXISTING FIRE BARRIER2HR RATED CMU WALL-UL U90590 MIN DOOR W/ SELF CLOSER 90 MIN DOOR W/ SELF CLOSER 90 MIN DOOR W/ SELF CLOSER 90 MIN DOOR W/ SELF CLOSER 90 MIN DOOR W/ SELF CLOSER EXIST. STAIR TO MEZZANINE REMOVE EXISTING WINDOWS REMOVE EXISTING DOOR AND FRAME LOBBY 101 WOMEN 115 MEN 114 GENERAL MANAGER 113 IT ROOM 112 BREAKROOM 111 OFFICE 1 109 PARTS MGR 108 SALES 102 SALES 103 SERVICE MGR 104 SERVICE WRITER 105 DRIVER'S LOUNGE 106 OFFICE MGR 107 CORRIDOR 117 CORRIDOR 116 PARTS SHOWROOM 118 TECH'S RESTROOM 121 OFFICE 120 WAREHOUSE 122 OPEN OFFICE 110 PARTS COUNTER 119 GENERAL DEMOLITION NOTES THE PURPOSE OF THESE DEMOLITION PLANS, AS MADE PART OF THE CONTRACT DOCUMENTS, IS TO GIVE THE GENERAL CONTRACTOR A GENERAL IDEA AS TO THE SCOPE OF ARCHITECTURAL DEMOLITION WORK REQUIRED. THESE DRAWINGS ARE NOT MEANT TO IDENTIFY ALL DEMOLITION WORK REQUIRED, NOR DO THEY ACCURATELY REFLECT ALL EXISTING CONDITIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE FACILITY, THOROUGHLY EVALUATE AND COMPARE THE OWNER'S RECORD SET OF DRAWINGS IF AVAILABLE,OF THE EXISTING FACILITY AGAINST THESE DRAWINGS & ACTUAL SITE CONDITIONS, AND REVIEW ALL CONTRACT DOCUMENTS TO ARRIVE AT THE SCOPE OF DEMOLITION WORK REQUIRED TO ACHIEVE THE INTENDED RESULTS AND FINISHED PRODUCT. ALL EXISTING SERVICE UTILITY LINES IN RENOVATED AREAS ARE TO TIE-IN INTO NEW SERVICE LINES OR ARE TO BE TERMINATED AND CAPPED OFF AS REQUIRED. TERMINATE OR OTHERWISE CAP OFF ALL ABANDONED UTILITIES BEHIND FINISH WALL SURFACES OR BELOW FLOOR SLABS. ALL CONCRETE, MASONRY, TILE AND PLASTER SURFACES INDICATED TO BE CUT AND PATCHED OR ARE ON A SURFACE IN WHICH A DOOR, WINDOW, OR PORTION OF THE SURFACE IS TO BE REMOVED, SHALL BE CUT WITH MASONRY SAWS OR SCORED FOR CLEAN JOINTS AND PATCHED FLUSH TO RECEIVE NEW MATCHING MATERIALS AND FINISHES. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE REGULAR REMOVAL OF ALL WASTE MATERIAL FROM THE PROJECT SITE AS IT PERTAINS TO THE RENOVATION ACTIVITIES, AND ALL AREAS USED BY BUILDING PERSONNEL SHALL BE KEPT CLEAN. IN LOCATIONS WHERE EXISTING WALLS ARE REMOVED, PATCH ADJACENT WALLS AS REQUIRED WITH MATERIALS AND FINISHES TO MATCH EXISTING OR AS SCHEDULED BY THE DRAWINGS. ALL ABANDONED OR REMOVED ELECTRICAL OUTLETS, LIGHT SWITCHES AND RELATED WALL OR CEILING BOXES SHALL HAVE ALL WIRE REMOVED COMPLETELY BACK TO THE ELECTRICAL PANEL. SOLID OUTLET COVERS MAY BE USED OVER THE ABANDONED SWITCHES OR OUTLETS PROVIDED. THESE ARE TO BE LOCATED NO LESS THAN 6" FROM AN ADJACENT WALL OR FIXTURE. IF MORE THAN 6", THE CONTRACTOR SHALL REMOVE THE BOX AND PATCH THE HOLE TO MATCH NEW FINISHES. ALL CEILING BOXES ABANDONED SHALL BE REMOVED-IF REQUIRED. THROUGHOUT ENTIRE PROJECT AREA: COMPLETELY REMOVE ALL PLUMBING FIXTURES AND ASSOCIATED WATER & WASTE PIPING, ALL FLOOR DRAINS AND CAP LINES. REFER TO PLUMBING DRAWINGS FOR SPECIFIC NOTES.THROUGHOUT ENTIRE PROJECT AREA: COMPLETELY REMOVE ALL FLOORINGS TO THE SUBSTRATE. EXPOSED SUBSTRATES ARE TO BE GROUND CLEAN OR OTHERWISE PREPARED TO RECEIVE NEW FINISHES. ABANDONED FLOOR DRAINS ARE TO BE REMOVED. LEVEL DEPRESSIONS TO ADJACENT FLOOR SLAB ELEVATIONS WITH THE SPECIFIED LEVELING COMPOUND. COMPLETELY REMOVE ALL CEILING GRID, TILE, LIGHTS, MECHANICAL DIFFUSERS AND EXIT SIGNS (REMOVE ASSOCIATED CEILING SUPPORTED ITEMS.) ALL OTHER COMPONENTS OF THE EXISTING CONSTRUCTION, NOT ESSENTIAL TO REMAIN, THAT WOULD INTERFERE WITH THE INSTALLATION OF NEW WORK OR INTERFERE WITH THE INSTALLATION OF NEW FLUSH, UNBROKEN PLUMB AND LEVEL WALL, CEILING, AND FLOOR SURFACES SHALL BE REMOVED. REMOVE EXISTING SHELVING, COUNTERTOPS, CASE WORK ETC. WITH RELATED TRIM, BLOCKING, FASTENERS, PLUMBING, AND ELECTRICAL. CAP ALL PIPING NOTED TO BE REMOVED AS PER PLUMBING DRAWINGS AND SPECS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY WALL AND/ OR FLOOR SURFACES BEHIND OR UNDER OBJECTS THAT ARE TO BE REMOVED. THE WORK IS TO INCLUDE BUT NOT LIMITED TO INSTALLING NEW GYP. BD., FLOORING AND PAINTING. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A SMOOTH LEVEL SURFACE IN ALL AREAS OF RENOVATION.CADFILE: 24x36DRAWN BY: CHECKED BY:L I L I A N A R. T O B O NAIA, LEED AP, NCARBSCALE DATE: REV.A r c h i t e c t3512 PRESTO N TRAIL M ARTINEZ, G A 30907TEL (706) 288-8273LTO BO N@ THEPETESTO RE.CO M1/4/2022 12:33:21 PMC:\Users\Liliana Tobon\Dropbox (The Pete Store)\LILIANA'S FILES\The Pete Store- 28- Fort Pierce, FL\existing drawings\FortPierce, FL- Existing OPT2.rvtAs indicated Author Checker JAN 3, 2022 22-001 A102 DEMOLITION PLANINTERIOR RENOVATIONPALM WAY INVESTMENTS, LLC5750 ORANGE AVENUE FORT PIERCE, FL 349473/16" = 1'-0"1 DEMOLITION PLAN REVDATEBYD E S C R I P T I O N