HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2014
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
SKO Co0C -d IZK'-
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the
residential Simulated Performance method shall include
❑ This checklist
❑ A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, e-ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst -case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report (1 page) and an input summary checklist that can
be used for field verification (usually 4 pages/may be greater).
❑ Energy Performance Level (EPL) Display Card (one page)
❑ Mandatory Requirements(three pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation inspection Component Criteria checklist (Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report(usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
Form R405 Duct Leakage Test Report.(usually one page)
9i22/2016 10:47:24 AIM
EnergyGaugeO - USRCZB v5.1
file Copy
Page 1 or 1
FORM R405-2014
'FLORI®A ENERGY EFFICIENCY CODE FOR BUIL®�Nt� CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Name: !7•e V_\0P A.UV3
Project Name Express 1828 Cali PSL RIGHT NEWBuilder
501-1^A_
Street SAL(o Co\aAAaakA P- OIL—
Permit Office:
City, State, Zip, S T LUCIE . FL ,
Permit Number
Jurisdiction: �•� l.-t�
rJr�vner, Express Homes
Design Lrcatlon. FL. ST LUGIE_CD._INTL
County: St. Lucie (Florida Climate Zone 2
1 New ccnstructlon or existing New (Fro^ P3ars)
,. Wall Types(1751, 2 sqf. !
irisatataon Area
a Concrete Block - In' irsul, Extencr
R=4 1 1422 10 ft'
2. Single family or multiple fiamih: Sing±e-fa n+•}'
b Frame -Wood, Adiacert
R=13.0 329.12 ft'
3 Nu,nnber of uniis. if multiple falisly INtA
P.= ft'
4
d NiA
R= '
4 Number of Bed7�ems
10 Ceiling Types (1528 0sgft.}
lrsuloticn Area
5 Is this a w: rst case? Yes
a U^der Attic (Vented)
R=38.0 1823 GO f'
6 C;ordit•onvd ,'loar area ab.ve grade fft l 1828
`' N:A
c NIA
R �,
R= t
Cor•ditioned rigor area ceiow grade i"} 0
11 Ducts
R
7 VJ indowst163 1 soft Descriotion .Area
a Sur. Attic. Ret.'Anic. •AH whoie house 8 150 3
a U-Factor Dbi U=0.34 127 2S v=
SH13C SHGC=O 35
12 �Jnciiny systems
FBtu;hr =_�clen. y
J-Facro- Db+. n . _ ., ft'
� L.= '3
a 3entral Unit
ER 1 30
35 0 S= 5
SHGC SHGC=0 32
c U-Factor N/A ft
cHr,C
13 Heats^g systems
kBtu,hr=fficsency
rJ U F2ct^r NrA ri'
a. Eiectric Heat Pu~}p
34 a HSPF 9 30
SHGC
Area bVetghted A•:erage Overhanc, neptn. 2 75r
.
14 Hot water syste�^�s
Area Wei7n111311. ted Average SHGC
a Electr.c
Cap 50 gaiters
8 Floor Types (1323 C 5gft ) Insuiat cri area
EF: 01)80
a Slab -Or -Grade Edge Insulation R=0 0 1328 CG f =
b Corse,, atior featuras
t NSA P,= "'
None
c PA ?_ V
i5. Credits
?S'3t
Total Proposed ,Modified Loads 56 66
PISS
G:'ASS/'i00' Area: 0.092 5r r�
Total Baseline Loads. 59.99
± hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance viith the Florida energy
specifications covered by this
'ti �. Na 4z
Code /
/ /
calculation indicates wmpliance
with the Florida Energy Code.
PREPARr D BY. _ � .-f — ._----_ —
Before const, action is completed
DATE ---
this building will be inspected for
0
'
_
- - -------- -.__-- --
compliance with Section 553 GO$
I hereby certify that this building, as cesignsd. is in corn:;fiance
Florida Statutes..
with the Florida Energy,42ode
Otr�,NERiAGENT {.. `'---------
-t
BUILDING OFFICIAL
--
DATE:
DATE.
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and insulation inspection Checklist in accordance with R402.4A.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duet leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0,030 Qn for whole house.
V251'2017 3:39 PiN Energ•;Gaugev USA - FiaRaS2014 Section R405 4 1 Cemoliant SottwareTlle ®„y Page 1 of 4
C(IDRA DAnC;_7r11A
PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Express 1916 Cali PSL RIGH Bedrooms:
User Conditioned Area: 1916
Express Homes Total Stories: 1
1 Worst Case: Yes
Rotate Angle: 225
Cross Ventilation: No
Whole House Fan: No
Single-family
New (From Plans)
Address Type: Street Address
Lot #
Block/SubDivision:
PlatBook:
Street:
County: St. Lucie
City, State, Zip: ST. LUCIE ,
FL,
CLIMATE
Design Location
IECC Design Temp
TMY Site Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Tamp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_IN T L FL_VERO_SEACH_MUNI 2 39 90
70
75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
1916 16860.8
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
In l ID Finished Cooled Heated
1
whole house
1916 16860.8 Yes 5
4
1 Yes Yes Yes
FLOORS
v#
Floor Tyre
Space Perimeter R-Vaiue
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio whole house 199 ft 0
191E ft'
-___ 0.5 0 0.5
ROOF
Iv #
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt Emitt Deck Pitch
Tested Tested Insul. (deg)
1
Hip Composition shingles 2143 tie 0 ft' Dark
0.9
No 0.9 No 0 26.5
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300 1916 ft'
N N
CEILING
Ceiling Type
Space Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
_R-Value
whole house 38 Blown
1916 ft$ 0.11 Wood
9122/2016 10 a7 AM EnergyGaugeV USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
1-vntvt r��v�-cv ��r
WALLS
t
s
Adjacent
Cavity Width Height
Sheathing
Framing Solar
Below
Space
a
_ f
a
f'
1
S=>NE Exterior Concrete Block - Int Insalrhole house
4.1 18 0 8.8
0
158.4 ft2
0
0 0.8
0
_
2
E=>NW Exterior Concrete Block - Int InsiAhole house
4.1 44 0 8.8
0
387.2 ft2
0
0 0.8
0
3
N=>SW Exterior Concrete Block - Int InsAhole house
4.1 39.8 0 8.8
0
350.2 ft2
0
0 0.8
0
4
W=>SE Exterior Concrete Block - Int Insa+hole house
4.1 59.8 0 8.8
0
5262 ft2
0
0 0.8
0
_
5
S=>NE Garage Frame - Wood whole house
13 21.4 0 8.8
0
188.3 ft2
0
0.8
0
- 6
E=>NW Garage Frame - Wood whole house
13 16 -0 8.8
0
140.8 ft2
0
0.23 0.8
0
DOORS
V
# Ornt Door Type Space
Storms
U-Value
Width
WidthArea
Ft
In
Ft
1 S=>NE Insulated whole house
None
.4
3
6.8 20.4 ft'
2 S=>NE Insulated whole house
None
.4
2
8
16 ft2
WINDOWS
Orientation shown is the entered orientation (_>) changed to Worst Case.
Wall
Overhang
V
# Ornt ID Frame Panes NFRC U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
1 S=>NE 1 Vinyl Low-E Double Yes
0.34 0.35
2.5 ft2
5 ft 0 in
2 ft 0 in
None
None
2 S=>NE 1 Vinyl Low-E Double Yes
0.34 0.35
31 2 ft2
1 ft 0 in
4 ft 0 in
None
None
3 E=>NW 2 Vinyl Loam-E Double Yes
034 035
15.6 ft'
1 ft 0 in
2 ft 0 in
None
None
4 N=>SV`! 3 Vinyl Low-E Double Yes
0.34 0.35
62.4 ft2
1 ft 0 in
2 ft 0 in
None
None
5 W=>SE 4 Vinyl Low-E Double Yes
0.34 035
15.6 ft2
'1 ft 0 in
2 ft 0 in
None
None
6 N=>SW 3 Vinyl Low-E Double Yes
0.63 0.32
40.8 ft2
S ft 0 in
2 ft 0 in
None
None
GARAGE
/
# Floor Area Ceiling Area Exposed Wail Perimeter
Avg, Wall Height
Exposed Wall Insulation
1 607.76 ft2 607.76 ft2
64 ft
8.8 ft
13
INFILTRATION
#
Scope Method SLA CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .00028 1405.1 77.14 145.07
.2097
5
HEATING SYSTEM
y
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump Split
HSPF:9
34 kBtu/hr
1
sys#1
9/22/2016 10:47 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
F'UKtVt K4U�-GU 14
COOLING SYSTEM
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit
Split
SEER: 15.5 35 kBtulhr
1077 cfm
0.73
1
sys#1
HOT WATER SYSTEM
V # System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.98 50 gal
70 gal
120 deg
None
SOLAR HOT WATER SYSTEM
VFSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model # Area
Volume
FEF
None None
ft2
DUCTS
Supply --
--- Return ---
Air
CFM 25 CFM25
HVAC #
kf # Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Coot
1 Attic
6 150.3 ft
Attic
87.5 ft2 Proo. Leak Free
whole hous
--- cfm 57.5 cfm 0.03 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jar, [[ Feb
Jan Febki
Mar
Mar
(
j
Apr
Apr
May IX] Jun rlJuf
E may j ]Jun Jul
Aug
Aug
ri
X Se (
4 Sep (�
Oct
Oct
Nov
Nov
Dec
Dec
HeatingX (X
Venting Jan [[ I Feb
Mar
tX
Apr
(lll may t ] Jun Jul
Au
t Se [XI
Oct
X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
11
12
Schedule Type
1
2
3
4 5 6
-
7
8 9
t 0
Cooling (WD) AM
78
78
78
78 78 78
78 76 78
78
78
78 80
78 78
80
78
80
78
80
78
PM
80
80
78
Cooling (WEH) AM
78
78
78
78 78 78
78 78 78
78
78
78 78
78 78
78
78
78
78
78
78
PM
78
78
78
Heating (WD) AM
66
66
66
66 66 68
68 68 668
68
68
68 68
68 68
68
68
68
66
68
66
PM
68
68
68
Heating (WEH) AM
66
68
66
68
66
68
66 66 68
88 68 68
68
68
68 68
68 68
68
68
68
66
68
66
PM
9i2212016 10:47 AM EnergyGaugeQ USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4
FORM R405-2014
I
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the EnergyPerformance Index, the more efficient the home.
ST. LUCIE, FL,
1
Nev construction or existing
New (From Plans) 9. Wall Types Insulation
Area
a. Concrete Block - Int Insul, Exterior R=4.1
1422.10 ft"
2.
Single family or multiple family
Single-family b. Frame - Wood. Adjacent R=13.0
329.12 ftz
3.
Number of units: if multiple family
1 c. N/A R=
ft=
4 d NiA R=
4.
Number of Bedrooms
10. Ceiling Types Insulation
Area
5.
Is this a worst case?
Yes a. Under Attic (Vented) R=38.0
1916.00 ft'
6
Conditioned floor area (ft')
1916 b. NIA R=
R=
ft'
ft2
c. NiA
7
Windows" Description
Area I Ducts
R ft'
a. U-Factor Dbl, U=0 34
127 29 ft' a Sup: Attic, Ret Attic, AH whole house
6 150.3
SHGC- SHGC=O 35
b. U-Factor: Dbl, U=0.63
40.80 ft'
SHGC: SHGC=0.32
12. Cooling systems kStulhr
Efficiency
c U-Factor NIA
ft' a Central Unit 35 0
SEER:15.50
SHGC
d. U-Factor' N/A
fta 13. Heating systems kBtu:hr
Efficiency
SHGC.
a. Electric Heat Pump 34.0
HSPF:9.00
Area Weighted Average Overhang Depth
2.758 `.
Area Weighted Average SHGC.
0.343
8
Floor Types
Hot water systems
Insulation Area 14. stems Cap50 gallons
a. Stab -On -Grade Edge Insulation
R=0.0 is 16 00 ft, a. Electric
EF: 0 98
b NIA
R= ft' b. Conservation features
c. N/A
R= ft' None
15 Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: _ ^ Date:
Address of New Home: (.OW_.ezuS �� , City/FL Zip: _J'-1e_-4,
`Note: This is not a Building Energy Rating. if your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1402 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
"`Label required by Section R303.1 3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
9 22I2016 10:47 ANI EnergyGauge9 USA - FlaRes2014 - Section R405.4 1 Compliant Software Page 1 of 1
FORM R445-2414
Florida Department of Business and Professional Regulations
` Residential Whole Building Performance and Prescriptive Methods
ADDRESS: Permit Number:
ST. LUCIE , FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
O 401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
[Section 553.9085, Florida Statues) requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrator compliance for the building. A copy of the EPL display card can be found in Appendix C.
❑ R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402.4.4.
O R402.4,1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
• R402.4.1.1 Installation. The components of the building thermal envelope as listed to Table R402 4 1 1 shall be installed in
accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1,1, as applicable to the method of construction.
Where required by the code official, an approved third party shall inspect all components and verify compliance.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air
changes per hour in Climate Zones 1 and 2, and 3 air changes per hour in Climate Zones 3 through 3. Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1 Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or
other in; €tration control measures:
2 Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed. but not sealed beyond intended
infiltration control measures:
3 Interior doors, if installed at the time of the test, shall be open:
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed,
5. Heating and cooling systems. if installed at the time of the test. shall be turned off: and
6. Supply and return registers, if installed at the time of the test, shall be fully open.
O R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers and outdoor combustion air.
O R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square ,loot (1.5 Uslm2), and swinging doors no more than 0.5 cfm per square foot (2.6 Uslm2), when tested according to NFRC 400 or
AAMAANDMA/CSA 10111 S.21A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more than 2.0 cfm (0.944 Us) vvhen tested in accordance with ASTM E 283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering
❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.2.2 Sealing (Mandatory)Ail ducts, air handlers, and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers, shall be constructed and seated in accordance
with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post -construction
or Tough -in testing below.
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section
553.99, Florida Statutes, or as authorized by Florida Statutes, to be 'substantially leak free` by either of the following:
1. Post -construction test: Total leakage shall be less than or equal to 4 cfm (113 Umin) per 100 square feet (9.29 m2) of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the entire system. including the manufacturer's air handler enclosure. All
register boots shall be taped or otherwise sealed during the test.
2 Rough -in test: Total leakage shall be less than or equal to 4 cfrn (113 Umin) per 100 square feet (9.29 m2) of conditioned floor area when tested
at a pressure differential of 0 1 inches w.g. (25Pa) across the system, including the manufacturers air handler enclosure. All registers shall be
taped or otherwise sealed during the test. If the air handler is not installed at the time of the test. total leakage shall be less than or equal to 3 cfm
(85 Umin) per 100 square feet (9.29 m2) of conditioned floor area.
Exceptions:
1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope.
2. Duct testing is not mandatory for buildings complying by Section R405 of this code.
9/22/2016 10:47 AM EnergyGaugeO USA - FlaRes2014 - Section R405A.1 Com Page 1 of 3
FORM R405-2014
IN
MANDATORY REQUIREMENTS - (Continued)
R403.2.3 Building Cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
R403.3 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105'F (41'C)
or below 55'F (13°C) shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping insulation.
R403.4.1 Circulating hot water systems (Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can turn of, the hot-water circulating pump when the system is not in use.
❑ R403.4.3 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shalt have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at feast 3'/2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible
to the storage tank.
❑ R403.4.4 Water heater efficiencies (Mandatory).
O R403.4.4.1 Storage water heater temperature controls
R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum
temperature setting range shall be from 100'F to 140'F (38'C to 60" C).
R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s)
of combustion types of service water heating systems to be turned off.
0 R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation. Commercial Provisions, for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1.
R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol, Collectors in installed solar water
heating systems should meet the following criteria-
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.5 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
❑ R403.6 Heating and cooling equipment (Mandatory). The following sections are mandatory for cooling and heating equipment.
O R403.6A Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated An accordance with ACCA Manual J or other approved heating and cooling calculation methodologies.
based on building toads for the directional orientation of the building. The manufacturer and model number of the outdoor and
indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302,1. This code does not allow designer safety factors, provisions for future expansion or other factors
which affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
• R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load, but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.6, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
gi22/2016 10:47 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Com Page 2 of 3
FORM R405-2014
' MANDATORY REQUIREMENTS - (Continued)
0 R403.6.1.1 Cooling equipment capacity. (continued) The published value for AHRI total capacity is a nominal, rating -test value and
shall not be used for equipment sizing. Manufacture's expanded performance data shall be used to select cooling -only equipment. This
selection shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry bulb temperature for the
load calculation (or entering water temperature for water -source equipment), the blower cfm provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multi -family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida -registered engineer, in attached single- and multi -family units, the capacity of
equipment may be sized in accordance with good design practice.
O R403.6.1.2 Heating equipment capacity
R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section
R403 6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403,6.1.
R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shalt not be less than the design load calculated in accordance with Section, R403 6.1
0 R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized
11 R403.7 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
❑ R403.8 Snow melt system controls (Mandatory). Snow and ice -melting systems, supplied through energy service to the building, shall
include automatic controls capable of shutting off the system when the pavement temperature is above 55°F, and no precipitation is falling
and an automatic or manual control that will allow shutoff, when the outdoor temperature is above 40°F.
0 R403.9 Swimming pools, inground spas and portable spas (Mandatory). The energy requirements for residential pools and
inground spas shall be as specified in Sections 13403.9.1 through R403.8 3 and in accordance with ANSItAPSP-15. The energy
requirements for portable spas shall be in accordance with ANSIfAPSP-14
0 R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on -off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
R403,9.1,1 Gas and oil -fired pool and spa heaters. All gas- and oil -fired pool and space heaters small have a minimum
thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013 when tested in accordance vvitil ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
0 R403.9.2 Time switches. Time switches or other control method that can automatically turn off, and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps. Heaters, pumps and motors that have built in timers shall be deemed in
compliance with this equipment
Exceptions:
• 1. Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor -retardant cover on or
at the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Outdoor pools deriving over 70 percent of the energy for heating from site -recovered energy, such as a heat pump or
solar energy source computed over an operating season.
• RR404A Lighting equipment (Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shalt be
high -efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low -voltage lighting shall not be required to utilize high -efficacy lamps.
0 R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
• R405.2 Performance ONLY. Ail ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
0 R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19 Where single assemby of the exposed deck and beam type or
concrete deck roofs do not have sufficent space, R-10 is allowed.
9122/2016 10:47 AM EnergyGaugeO USA - FlaRes2014 - Section R405.4.1 Com Page 3 of 3
FORM R405-2014 TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Express 1916 Cali PSL RIGHT NEW Builder Name:
Street: Permit Office:
City, State, Zip: ST. LUCIE . FL, Permit Number.
Owner: Express Homes Jurisdiction:
Design Location: FL, ST_LUCIE_CO_INTL
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Comers and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
from the showers and tubs.
barrier installed separating them
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shalf have
gasketed doors
9/22/2016 10:47 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software rage 1 or 1
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: Express 1916 Cali PSL RIGHT NEW Builder Name:
Street: Permit Office:
City. State, Zip: ST. LUCIE , FL, Permit Number:
Design Location. FL, ST_LUCIE_CC_INTL Jurisdiction.
Cond. Floor Area:: 1916 sq ft. Cond. Volume: 16361 cu ft.
Envelope Leakage Test Results
Regression Data:
C• n:-- R:
Sinqle or Multi Point Test Data
HOUSE PRESSURE I FLOW:
Leakage Characteristics
CFM(50)--
ELA:
EgLA.
ACH.
ACH(50):
SLA.
R402.4.1.2 Testing. The building or dwelling unit shall be tested aria verified as having an air leakaga rate of not exceeding 5 air changes per hour
in Climate Zones 1 and 2, 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2
inches w a (50 Pascals' Where required by the code official, testing shall be conducted by an approved third party A written report of the results of the
test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all
oenetrations of the building thermal envelope.
During testing.
Exterior windows and door, fireplace and stove doors shall be closed, but not sealed, beyond the 'intended weatherstripping or other
infiltration control measures;
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not seated beyond intended infiltration
control measures
3. Interior doors, if installed at the time of the test, shall be open,
4 Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed,
5, Heating and cooling systems, if installed at the time of the test, shall be turned off; and
6. Supply and return registers, if installed at the time of the test, shall be fully open.
I hereby certify that the above envelope leakage
performance results demonstrate compliance
with Florida Energy Code requirements in
accordance with Section R402 4.1.2.
SIGNATURE:
PRINTED NAME:
DATE:
Where required by the code official,
testing shall be conducted by an
approved third party. A written
report of the results of the test shall
be signed by the third party
conducting the test and provided to
the code official.
BUILDING OFFICIAL:
DATE:
91'2212016 10:47 AM EnergyGauge® USA - FlaRes2014 - Section R405 4 1 Compliant Software Page 1 of 1
FORM R405-2014 Duct Leakage Test Report Performance Method
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Form R405 Duct Leakage Test Report
Performance Method
Project Name: Express 1916 Cali PSL RIGHT NEW Builder Name:
Street: Permit Office:
City. State, Zip: ST. LUCIE , FL, Permit Number:
Design Location: FL, ST_LUCIE_CO INTL Jurisdiction:
Duct Test Time: Post Construction
nI lrt 1 Pakane Test Results
i
CFM25 Duct Leakage Test Values
Line System Outside Duct Leakage
1 System 1 _ cfm25(Out)
2 ? System 2 y
cfm25(Out)
j
3 j System 3
cfm25(Out)
I
4 System 4
cfm25(Out)
5 i Total House
Sum lines 1-4
Duct System
Divide b y
I Leakage
� f g
j (rota! Conditioned Floor Area)
I +
i !
I
! i
l = (Qn,Out) !
I
l
I certify the tested duct leakage to outside, Qn, is
not greater than the proposed duct leakage Qn
specified on Form R405-2014-
SIGNATURE:
PRINTED NAME:
DATE:
Duct tightness shall be verified by
testing to Section 803 of the RESNET
Standards by an energy rater certified in
accordance with Section 553.99,
Florida Statutes.
BUILDING OFFICIAL:
DATE:
9122/2016 10:47 AM EnergyGaugeV USA - FlaRes2014 - Section R405.4.1 Compliant S Page 1 of 1