Loading...
HomeMy WebLinkAboutAluminum Roof Over Plani A ` 024 ALUM ROOF ` 024 ALUM ROOF EXTRUDED ALUM. ATTACH RAIL 024 ALUM ROOF CONT. OVER T RIDGEO POLYSTYRENE INSULATION 2' RIDGED POLYSTYRENE INSULATION wl#8X1114 S.M.S. 3' O.C. FASCIA EDGE DETAIL OR RIDGE WI FACTORY SEAMS @ 48' O.C. EXISTING MOBILE HOME ROOF EXTRUDED ALUM. ATTACH RAIL EXISTING PATIO ROOF BUM RUBBERSEAL GUTTER EDGE DETAIL' wl #BX11/4 S.M.S. T O.C. , r BUM RUBBERSEAL ,_i%T, r .024 ALUM FLASHING INTO PAN % �\--- �r�`� AND CAULK OR CONTINUE : ' -- -- - - - - - - - 024ALUMFLASHING �"LY� FLASHING TO GUTTER ®C----------- - 7.--- __ BUTYLRUBBERSEAL 2-48SMSw/NEOPRENE INSULATION jjj//// UD ALUM. ATTACH RAIL WASHERS TO TOP OF EACH PAN w!#8X11/4 14S.M.S.3'O.C. 2X3 P.T. W/ #8X3' W.S. @ 9' O.C. 024 ALUM ROOF 2X3 P.T. w/#8X3' W.S. (� 6' O.C. /,� EXISTING INTO EXISTINGCOACHFRAME INSULATION ��. �* ��/ MOBILEHOMEROOF SINGLE WIDE (NTS) 2X3 P.T. BLOCKS CUT TO FIT INTO fc�i r, PANS W/ (2) #8 S.M.S. PER PAN FYICTIMr EXISTING COACH OVERHANG � ' FRAME ,/ EXISTING ALUM. POLYSTYRENEFOAM COL. & BEAM INSERT EACH PAN EXISTING PATIO ROOF EXISTING WALL CHANNEL 024 ALUM R ALTERNATE COACH & PATIO ROOF ATTACHMENT #1 ALTERNATE PATIO PAN ROOF ATTACHMENT DETAIL "A" 7RIDGEDPOLYSTYRENE INSULATION CONNECTION DETAIL (NTS) (NO 41hWALL) N.T.S. EXISTINGMOBILE HOME ROOF EXTRUDED ALUM. ATTACH RAIL >; r .024ALUM ROOF wl#BX11/4S.M.S.3'O.C. 30# FELT ON TOP OF BUM RUBBER SEAL 1 024 ALUM ROOF. PA .024 ALUM FLASHING INTO PAN 7 RIDGED POLYSTYRENE INSULATION AND CAULK OR CONTINUE EXISTING MOBILE HOME ROOF i-,EXTRtUEDSA.LU.DM.ATTACH RAIL r FLASHING TO GUTTER 2X3P.TWI#BX3'W.S.@6'0 wl#8X1114MS. 3' O.C. �, �= �, , . INTO EXISTING COACH FRAM M r 1 BURUBBER SEAL 2 #8 SMS wl NEOPRENE WASHERS TO TOP OF EACH PAN 2X3 P.T. WI#BX INTO EXISTING 2X3 P.T. BLOCKS CUT TO FIT It PANS w/ (2) #8 S.M.S. PER PAN EXISTING COACH FRAME 024 ALUM ROOF FLASHING ,r-EXTRUDED ALUM. ATTACH RAIL w/#8XI iW S.M.S.3' O.C. / / 024 ALUM ROOF -30# FELT ON TOP OF -EXISTING PANS w/ INSULATION INSERTS EXISTING ALUM. COL & BEAM ALTERNATE COACH & PATIO ROOF ATTACHMENT #2 CONNECTION DETAIL (NTS) (wl4th WALL) .024 ALUM ROOF 2' RIDGED POLYSTYRENE INSULATION % EXISTING MOBILE HOME ROOF i 7,71 2X3 P.T. W198X3' W.S. ® 4W C INTO DaSTING•,COACH FRAME "X�M EXTRUDED ALUM. ATTACH RAIL wl #8X1 114 S.M.S. Y O.C. rBUTYL RUBBER SEAL r024 ALUM ROOF 1 rINSULATION r EXISTING COACH--7 I L-EXSTING PATIO ROOF FRAME ��i' L�TAPZEDSNSULATION PANW AS REQUIRED XISTING WALL CHANNEL TYPICAL ROOF SECTION N.T.S. EXTRUDED ALUM. ATTACH RAIL w/ #8X1114 S.M.S. T O.C. . RUBBERSEAL #81L W STAINLESS STEEL HEX HEAD FROM ATTACHMENT RAIL TO EXISTING MOBILE HOME FRAME @ 5' O.C. MIN. INTO EXISTING FRAMING 11BY' WIDE BUM RUBBER CONT.--�, .024 ROLL ALUMINUM INSULATION ATTACH CONT. TX4' P.T. TO EXISTING MOBILE HOME FRAMING W/#B)X WOOD SCREWS @ SPACING TO STRAIGHTEN WOOD ONLY, IN LIEU OF FULL FRAMING .024ALUM GUTTER ATTACHMENT PER DETAILS • W/STRAPS@4'-0O.C. EXISTING MOBILE HOME F FRAMING 3 ROOFING %EXISTING ALUM.-PSERTEACHPAN M GUTTER EDGE DETAIL ` ALTERNATE ATTACHM ' COL &BEAM INSERT EACH PAN / 71;- N.T.S. ST. LUC?E COUNTY BUMD]NI DIVISION ALTERNATE PATIO PAN ROOF ATTACHMENT DETAIL "BRE VIEWED FOR Ica; IA�IC N.T.S. VWI<D BY .024'ALUM DATE �.- -- PLANS AP�� FERMI" �IiiS l BE IOLf Obi BUM RUBBER SEAL, OR NO L 1SPECTION WELL BE"MADL � LL rEXTRUDED ALUM. ATTACH RAIL 7 RIDGED.POLYSTYRENE INSULATION OVERLAPPING .024 ALUM ROOF \ EXISTING PANS wl INSULATION INSERTS 2)0 P.T. BLOCKS CUT TO FIT It PANS WI (2) #8 S.M.S. PER PAN OVERHANG w/#8X1114 S.M.S. 3' O.C. 2X3 P.T. wl#8X3' W.S. @ 3' O.C. EXISTING CENTERCAP J N-EXISTING COACH FRAMING DOUBLE WIDE RIDGE DETAIL N.T.S. 7 RIDGED POLYSTYRENE INSULATION OVERLAPPING .024 ALUM ROOF \ 7 RIDGED POLYSTYRENE INSULATION EXISTING MOBILE HOME ROOF-7 EXTRUDED ALUM. ATTACH RAIL wl #8)0% S.M.S. 3' O.C. P.T. WOOD BLOCK WI #8X3' W.S, @ SPANNING TO STRAIGHTEN WOOD ONLY 2X3 P.T. WI #8)i INTO EXISTING ALTERNATE COACH & PATIO ROOF ATTACHMENT #3 EXISTING CENTER CAP J `EXISTING COACH FRAMING CONNECTION DETAIL (NTS) (NO DROP BETWEEN ROOFS) DOUBLE WIDE RIDGE DETAIL USING ALTERNATE #1 ATTACHMENT (NTS) MOBILE HOME ALUMINUM ROOF OVER PLAN FOR 185 MPH EXPOSURE C EXISTING FRAME COACH AND PATIO ROOF CONNECTION DETAILS FOAM INSULATION /—.024 ALUM ROOF PATIO PAN ROOF PATIO ROOF 12' NOTE: THISALTENNATE MAYBEUSEDTOOMRIN PROGRESSINSPECTM S• OFFRAM 3' NOTE THIS CONNECTION MAY BE USEDATALL CONNECTION AREAS AS ALTERNATE CONNECTION RAIL #BN1-114 STAINLESS STEEL SCREWS @ 5' O.C. INTO PRE -PUNCHED HOLES. RAIL FASTENING #1 024 GALVALUME CLEAT 48- O.C. (fYP) "EXTRUDED ALUM. ATTACH RAIL STYRENE-BUTADIENE wl#8X11/4 S.M.S.3.O.C. FACTORY SEAM DESIGN FOR. RUBBER SEALANT ALUMINUM ROOF COVERINGS BETWEEN SHEET & CLEAT ,.,-BUTYL RUBBER SEAL OVER SOLID ROOFS ONLY PRODUCT APPROVAL #FL5739 .024 ALUM FASCIA N.T.S. fAT ADJACENT PATIO ROOF NOTES: PROVIDE .024 FLASHING 1.) THIS DESIGN CONFORMS TO THE 2014 FLORIDA BUILDING CODE FOR A INTO PATIO ROOF (MIN 81 CATEGORY H BUILDING FOR WIND LOADING OF 185 MPH, EXPOSURE C AS wl#8 SMS @ 170.C. DETERMINED BY ASCE STANDARD 7. 2.) THIS DESIGN CONFORMS TO FLORIDA STATUTE 15C-2.008I FOR EXISTING EXTRUDED WALL CHANNEL MOBILE/MA ROOFING IS D SIGNEDOME FOR USE O REMODELING. SOLID � 3.) ALUMINUM ROOFING IS DESIGNED FOR USE OVER A SOLID ROOF ONLY. IT - ���� ' SHALL NOT BE USED AS A STRUCTURAL ROOF SYSTEM. � 4.) THE ROOF COVERING SHALL NOT OVERHANG HE EXISTING ROOF. 5.) ENGINEER IS NOT RESPONSIBLE FOR STRUCTURAL INTEGRITY OF EXISTING ROOF. THE STRUCTURE OF HE EXISTING ROOF SHOULD BE ABLE TO CONSTRUCTIONSUPPORT THE LOADING 6.) MAXIMUM WIDTH OF A SINGLE WIDE HOME NOT TO EXCEED 14'-0. FASCIA EDGE DETAIL 7.) MAXIMUM WIDTH OF A DOUBLE WIDE MOBILE HOME NOT TO EXCEED 2&-0 N.T.S. 8.) INSULATION TO BE POLYSTYRENE FORM APROX. DENSITY 1# PER S.F. 9.) MAXIMUM HEIGHT OF MOBILE HOME NOT TO EXCEED 15'-0-. 10.) MINIMUM THICKNESS OF ALL ROOF FLASHING TO BE .024 ALUM. 11.) THE R-VALUE OF HE 2' EPS INSULATION IS R=6.7. - SHEET No.: S1 Of 2 OWNER: (J (f e� NOT VALI NLESS D D ADDRESS: 13gsg &S NH E SS CITY: ef. ( C(rCe STATE: 1- I , ZIP: ENG 1<7 ES BUSHOUSE, P.E. LOT# BLOCK# RANGE: PROFESSIONAL ENGINEER20311 STATE OF FLORIDA N O O I O to m q ti co w N h; p R1 O C� w o� q oak• � 04 wCO C,2 coo 'IJ to � 4 � o 04 b i -0) CO c� C4C4N O Q4� Ob �4 4 se U iI EXTRUDED ALUM. ATTACH 7 w/ #BXl 1/4 S.M.S. 3' O.C. 12'xl2•x.024 ALUM CAP .024 ALUM 2' RIDGED POLYSTYREI 3' MIN THICK BONDED PANEL—� NOTE: MAX 12 SPAN BONDED PANEL EXISTING ALUM. COL & BEAM OR FRAMING EXTRUDED ALUM. ATTACH RAIL wl #8X1114 S.M.S. S.O.C. BUTYL RUBBER SEAL 2)T PTwl 114)6 TEX SCREWS @ S' O.C. THRU BONDED PANEL INTO EXISTING BEAM 024 ALUM FLASHING - _ EXTRUDED ALUM. ATTACH RAIL w/l�8X1 1/4 S.M.S. 3' O.C. �BUTYL RUBBER SEAL ALUM FLASHING OVERHANG MAX 29 WIDTH PARK MODEL DETAIL A N.T.S. EXTRUDED ALUM. ATTACH RAIL- w/ #8XI 1/4 S.M.S. 3' O.C. 12'x12'x.024 ALUM CAP LAP OF ROOF ROLL TO BE ON DOWNWARD SIDE .024 ALUM ROOF T RIDGED POLYSTYRENE EXTRUDED ALUM. ATTACH RAIL INSULATION wl#8X1114S.M.S.3'O.C. BUTYLRUBBERSEAL .024 ALUM FLASHING T MIN THICK BONDED PANEL / 250' PTw1 #B:Ci• SMS ® 4' INTO NOTE: EXTRUDED METAL & BONDED PANEL MAX 12 SPAN BONDED PANEL j I'MAX. O.H. \-.032 EXTRUDED FASCIA EXISTING ALUM. / EXISTING OR GUTTER COL ♦E BEAM / OVERHANG �+ OR FRAMING. BONDED PANEL ROOF EDGE DETAIL #1 N.T.S. MOBILE. HOME ALUMINUM ROOF OVER PLAN FOR 185 MPH EXPOSURE C MAX 14' WIDTH PARK MODEL DETAIL B N.T.S. - 0 RUBBER SEAL 2'x4' PT CONT. w/ #Bx3' WOOD SCREWS @ 6• O.C. TO RIDGE BEAM & 1484' WOOD SCREW TO EACH TRUSS .024 ALUM ROOF-. r 2• RIDGED POLYSTYRENE INSULATION -2W WOOD TRUSS @ 24.0.C. w/ IM SHEATHING EXTRUDED ALUM. ATTACH RAIL w/.#8X1 1/4. S.M.S. 3' O.C. �. �JJJj1'� BUM RUBBER SEAL /j/j/j/ /-SEE / FASCIA UEEDDGE3 DETAILS, S-1 2x4 P.T. w/#Bx3'WOOD SCREWS MAX 18' O.H. --� @ W O.C. TO FASCIAw/ 1-#W TO EACH TRUSS TAIL @ 24'O.C. CONTINUOUS 2' FASCIA TYP. YL RUBBER SEAL 2k4• PT CONT. W/2 0x3• WOOD SCREWS T66CH TRt;§S !_ \ .024 ALUM ROOF 2' RIDGED POLYSTYRENE INSULATION 2'x4' WOOD TRUSS @ �T 24.O.C. w/ 1/2' SHEATHING EXTRUDED ALUM. ATTACH RAIL G rj.� _ w/ #8X1 1/4 S.M.S. 3' O.C. �BUTYL RUBBER SEAL SEE FASCIA GUTTER DETAILS, s-1 2x4 P.T. w/#8x3'WOOD SCREWS MAX 18' O.H. @ 12' O.C. TO FASCIAW/ 1-#8x3' TO EACH TRUSS TAIL @ 24'O.C. CONTINUOUS 2' FASCIA TYP. OWNER: � (/ U i /� Lcceil e ADDRESS: (3�S co dy-n c) CITY- _ ( r-rc ✓ STATE: F f ZIP: ' LOT# BLOCK# RANGE r N O O I O cc 0 o0/i q D2 w to Qo y 40 40 o, I Q 4 0 Z LU � Q _ U SHEET NO.: S2 Of 2 NOTALjl UNLESS &S DWIT24E t N co w ob E to m co V4•N O�ch cmco I� Cp dq � cq N• w b to 1 00j 44j •qm IlkV q C4 4 .t to h4o w Qq Q I lC�f/' ES BUSH USE, P.E. Z PROFESSIONAL ENGINEER20311 Y STATE OF FLORIDA U