Loading...
HomeMy WebLinkAboutProduct Approval-Affidavit-Asphalt ShinglesBuilding Permit # Planning & Development Services Department Building & Regulations Division Product Review Affidavit Owners NameLeOtM tee( Applicant: 0V\25A- `{)CAQY-'�L,C• CN�ht� Product Opening Design Pressures Product Rated Design Pressure Manufacturer Model Number Product Approval NuMbpq Glass pe Method of Attachment Windows Mullions V Fixed Glass Block Glass Skylights Sliding Glass Doors Swing Type Doors French Doors Garage Doors Hurricane Protection Roof Ventilation Roofing Material �UKhS Cor�nW� r �.. �d(p1y— 1 I �j ►� r od'f��� 1f�a►�S j �eck (D v mkl s ., Revised 07/22/2014 I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. Name: Signature: seal Design Prof: Cert. No. Date: Page 1 of 2 ggmgggg BCIS Home ? Log In i User Registration ' Hot Topics S Submit Surcharge Stats & Facts Publication' ,: y FBC}Staff . BCIS Site.Map ; links Search g flu; Product Approval , USER: Public User Product Aporor� '4=r9 > Product or Awlic-�jo, Search > Application List > Application Detail FL # _ FL10674-R12 Application Type Code Version Revision Application Status 2014 } Approved `*A-pproved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission If necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method +` Owens Corning -=';,•One Owens,Coming Parkway i�Toledo;'OH 43659 (740) 404-7829 greg. keeler@owenscorning.com Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Greg Keeler greg.keeler@owenscorning.com Mel Sancrant 1 Owens Corning PKWY Toledo, OH 43659 (419) 376-8360 rnel.sancrant@owenscornig.com DEC 0 5 2017 Q-RiMI171NG St. Lucie County, FL - Asphalt Shingles _ —'� Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer i .t Evaluation Report - Hardcopy Received Robert J.M. Nieminen PE-59166 UL LLC 05/16/2020 John W. Knezevich, PE Yj Validation Checklist - Hardcopy Received FL10674 R12 COI 2016 01 COI Nieminen odf Standard ASTM D3161 ASTM D3462 ASTM D7158 Year 2009 2009 2008 https://www.floridabuilding.org/prlpr_app_dtl.aspx?paramn wGEVXQwtDgtBNbEY5VD/o... 12/1/2017 1,1w1ua Dunuing i-oae unline Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 04/18/2016 Date Validated 04/19/2016 Date Pending FBC Approval 04/20/2016 Date Approved 06/08/2016 Date Revised 10/10/2017 Summary of Products FL # Model, Number or Name Description 10674.1 Owens Corning Asphalt Roofing Shingles and Starters Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to ER, Section 5. 3-tab, 4-tab, 5-tab, laminated, starter and hip & ridge shingles Installation Instructions FL10674 R12 II 2016 04 FINAL ER OC ASPHALT SHINGLES FL1067�-R'•2 odf Verified By: Robert]. M. Nieminen PE - 59166 Created by Independent Third Party: Yes Evaluation Reports FL10674 R12 AE 2016 04 FINAL ER OC ASPHALT SHINGLES FI 10674-R12 odf Created by Independent Third Party: Yes Sack l Next Contact :: 2601 Blair Stone Read Tallahassee FL 32399 _Phone: 850-487-1824 The State of Florida IS an WEED employer. Coovrioht 2007 201a SrAjq of Florida. :: Privacy Statement :; A[cessibiliN romonr •• -� .. Refund S aw_nu.,r Under Florida law, email addresses are public records. If you do not want your e-mail address released in response [o apublic-records request, do not Send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact cords request, 'Pursuant to Sthey ection have one. The Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email addrrnss if supply a personal ddressa�pl asevprovide the Departmentwith anmemail addressmunication nwhich licensee. be made available er alto the pub. To determineare Public record. (yofu You are aOnot licensee huto nder Chapter 455, F.S., please click here . Product Approval Accepts: https://www.floridabuilding.org/pr/pr_app_dtl.aspx?paratn=wGEVXQwtDgtBNbEY5 V%... 12/1/2017 . �4"�"1 TRINITYERD EVALUATION REPORT Owens Corning One Owens Corning Parkway Toledo, OH 43659 SCOPE: EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #95o3 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report 037940.02.12-R7 FL10674-1112 Date of Issuance: 02/06/2012 Revision 7: 04/18/2016 This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 04/18/2016. This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the CERTIFICATION OF INDEPENDENCE: Product Approval Administrator and to the named client 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ROOFING SYSTEMS EVALUATION: 1. SCOPE: TRINITY ERD Product Category: Roofing Sub -Category- Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Pro a Standard 1507.2.5, R905.2.4 Physical Properties Year 1507.2.7.1, R905.2.6.1 Wind ResistASTM Dance ASTM D3163461 2009 1 1507.2.7.1, R905.2.6.1 Wind Resistance 200 ASTM D7158 2008 3. REFERENCES: 99!!ty Examination Reference UL LLC (CER9626) Date Physicals & Wind Resistance File R2453, Vol. 3 02/1 UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 02/15/2007 UL LLC (TST9628) Physical Properties 05/16/2012 (TST9628) ULLLC06CA20263 04/18/2006 Wind Resistance 11CA34308 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/ /201 UL LLC (TST9628) Wind Resistance 02/O1/2014 UL LLC TST9628 4786126532 02/10/2014 (TST9628) Physical Properties Classification letter UL LLC (TST9628) Physical Properties 02/13/2014 CER1592 Classification letter 10/02/2015 Miami -Dade ( ) FBC HVHZ Compliance Various NOAs UL LLC (QUA9625) Quality Control Various Service Confirmation, R2453 Exp. 08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme' are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 DevonshireTM' are fiberglass reinforced, 5-tab asphalt roof shingles. 4.1.4 Durations, TruDefinitione Duration" Duration' Premium Cool, TruDefinition' Duration' Designer Color Collection, TruDefinition Oakridge , Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire' Hip & Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgel Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, LLC. certificate of Authorization #95o3 Evaluation Report 037940.02.12-R7 FL10674-R12 Revision 7: 04/18/2016 Page 208 10 \"j 5_4 Wind Classification: TR NIWIERD 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (V,,,r = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd =150 mph (V,,,t =194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. S.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 61G20-3. 6. INSTALLATION: *6.1 Underlavment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6_2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire shingles require minimum five (5) nails per shingle. ➢ WeatherGuard® HP shingles require minimum six (6) nails per shingle. ➢ Devonshire'" shingles require minimum six (6) nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. , 1,6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC �" 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing —Starter Strip Shingle and Starter Strip Plus: Felt undedayment peck Self.adheWeatherred r fir nderiayment edge Drip edge Nails located Y' 3"from eave Install first Self seaastg adhasive StarterSip positioned along eave 6" n moved Starter Strip shingle overhangs eaves and rakes �14c =:j" Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R7 CertrTicate of Authorization #9503 FL10674-R12 Revision 7: 04/18/2016 Page 3 of 8 6.2.6 Minimum Nailing — Classic° & Supreme: Normal RUnvard or Aree pem Wind Areas. N+Bh'LWnd Hoxvanes y Area Pam vtantos »ormeiea Artier went. fuertea 2. �' Eacposuee £erprt9%i� 6.2.7 Minimum Nailing — Berkshire°: Standard Fastening Pattern =a 1'003g1Bf.PMXM cer—tod8?SCho*W fto I KIN, ITY I ERD WKara! Areal �•or e Ame torn vmntos nwm+/+yo Areas vietmoa.l rtes rzi 2" r If. IJ 6 6t8' Eatpaxura f1rPairiiin Mansard or Steep Slope Fastening Pattern 6-Nail Fastening Pattern Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 037940.02.12-R7 FL10674-R12 Revision 7: 04/18/2016 Page 4 of 8 6.2.8 Minimum Nailing— Devonshire—: 53/8° exposure Exposicibn de 5.518 ping Sealant location Ubicacibn del sellador Jianaara b-Nail Fastening Pattern 4-'4R.1-9 Minimum Nailing — Duration®, TruDefinition° Du Designer Color Collection: "aa Fastening Pattern suettaS�tu�ogp aeawdmli Standard Fastening Pattern Exterior Research and Design, I.I.C. certificate ofAuthorization #9503 `TRINITY.jERD I wIdnsara or xeep Slope Fastening Pattern Duration° Premium Cool & TruDefinition' Dura 'one 6adatt Fastening PattQm I, ,s r' ' mansard or Steep Slope Fastening Pattern Evaluation Report 037940.02.12-117 F1.10674-1112 Revision 7: 04/18/2016 Page 5 of 8 Q TRINITY ► ERD i 6.2.1 Minimum Nailing—TruDefinition'Oakridge®, Oakridge®: 4 N91 Pattom Ew-eras con4 claws 55i8" Exposute xpasSti6rtde3Bpt¢ Balls. Cral'os Fa}wsiGori iti<33/Spu'� Standard Fastening Pattern EWema Om 6P.aros I6518`-� Txaes �oad6n�P5fit8yuta G€avos lyp�.I mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing — WeatherGuard4 HP: Exterior Research and Design, LLC. Certificate of Authorization #9503 r o-rvan rastenmg Pattern sines -We view 55"rEwsum , I Fxpmgww & SS18ptdp Evaluation Report 037940.02.12-R7 FL10674-R12 Revision 7: 04/18/2016 Page 6 of 8 r \ I �j. TRINITY I ERD 6_3 HiD & Ridge Shingles: 6.3.1 Installat�eShin idge Shingles, High Ridge, WeatherGuarde HP Hip and Ridge Shingles and roEdgecomply with the manufacturer's current published instructions, using four f DuraRidge' Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. �.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC ��ll 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing— Berkshire® Hip & Ridge and High Ridge: t Fia..1 04 c4 4,\N { { { \ r It— :r—il 2 -- 7aPtdac wdeV4u ! lap la lwged d" i I wh.1i t I 'j I .4{ i � V I I 6.3.4 Minimum Nailing — WeatherGuardo HP Hip and Ridge: Fig..0 Hip: Ridge Shingle Easterling 76pVk77 _I I aal's aa{� e�osaee Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7 Certifcate ofAnthorrzotion #9503 FL10674-R12 Revision 7: 04/18/2016 Page 7 of 8 TRINITY ERD 6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles: PrevaBing Standard 1NindDhection SeaimtSf* Fastening 11° \, Pattern } tI r 12` I } Sealsart Fasten 7ikt .. 77h'ROO 6° Espasrira wVMh 6.3.6 Minimum Nailing — DuraRidgeTM' Hip & Ridge Shingles: Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning Published installation instructions for their minimum requirements. Top Vier !� it Van se�rFpr i-I r A I I I Ilb 2L i 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Qualit herein. y Assurance Agency noted 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. H. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC— QUA9625 ; (414) 248-6409; karen.buchmannPul com - END OF EVALUATION REPORT - Exterior Research and Design, I.I.C. Certificate ofAothorization #_g503 Evaluation Report 037940.02.12-R7 F1.10674-1112 Revision 7: 04/18/2016 Page 8 of 8