HomeMy WebLinkAboutRHVAC LoadsExpress Arden Lucie Right HVAC Load Calculations for Express Homes FlESIDRPi`iiAL, HVAC LOADS Prepared By: Kristin Kelly Florida Breeze 6928 Vickie Circle Suite B West Melbourne, FI 32904 321-951-8767 Friday, July 14, 2017 : Rhvac is an ACCA approved Manual J and Manual D computer program. File. C®per, Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. vacs Ros denftal'Lig tcom eicraT� C*Load's""U.'`""ss ,k. "):tits Sift dare Devetaprn8nk; {dc f lq�i`"ax8r2eze Express d ciR�ght3 Project; Report GeneraliP`rci act InfQrmaYN Project Title: Express Arden Lucie Right Designed By: Kristin Kelly Project Date: June 22, 2017 Client Name: Express Homes Company Name: Florida Breeze Company Representative: Kristin Kelly Company Address: 6928 Vickie Circle Suite B Company City: West Melbourne, F132904 Company Phone: 321-951-8767 De '1Qat Reference City: ST. LUCIE, FL Building Orientation: Front door faces South Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 n/a n/a 70 n/a Summer: 95 78 47% 50% 75 53 Total Building Supply CFM: 1,234 CFM Per Square ft.: 0.627 Square ft. of Room Area: 1,969 Square ft. Per Ton: 579 Volume (W): 16,379 8u(diriLoac . . Total Heating Required including Ventilation Air: 29,733 Btuh 29.733 MBH Total Sensible Gain: 33,585 Btuh 82 % Total Latent Gain: 7,199 Btuh 18 % Total Cooling Required Including Ventilation Air: 40,784 Btuh 3.40 Tons (Based On Sensible + Latent) !l�§tesU*_ � ;; Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. E:1SanDiskSecureAccess\RHVACIEXPRESS 1969 ARDEN LUCIE RIGHT 4EDB PG.rh9 Friday, July 14, 2017, 4:10 PM Rh�vac 'Re'si_dontial'& Light ercfa{ t 1YAG �oads�' ' -l�lorida Breeze �` "s'` +s ...Flit a Sat ors DeGQtoprnent, !n'c press Arden L cre Rig i Melbou FL 32934 Pa a 3. Miscellaneous Report ystem 1 VI! ole House Odoor Outdao outdoor Indoor indoor Grains to • ufi Data D B Wet u!b Re1.Hum Rel. D., i3ulb t7ifference Winter: 42 39.4 80% n/a 70 n/a Summer: 95 78 47% 50% 75 52.90 D ctjSiFi l_n ur- Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.01000 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft, Minimum Velocity: 550 ft./min 450 ft./min Maximum Velocity: 600 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Q9tsMMMta Winter Summer Infiltration Specified: 0.500 AC/hr 0.260 AC/hr 136 CFM 71 CFM Infiltration Actual: 0.500 AC/hr 0.260 AC/hr Above Grade Volume: X 16,379 Cu.ft. X 16.379 Cu.ft. 8,190 Cu.ft./hr 4,259 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 136 CFM 71 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1-- Infiltration & Ventilation Sensible Gain Multiplier: 21.98 = (1.10 X 0.999 X 20.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 35.94 = (0.68 X 0.999 X 52.90 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infiltration Specified: 0.500 AC/hr (136 CFM), Construction: Average Summer Infiltration Specified: 0.260 AC/hr (71 CFM), Construction: Average bucf oad NE(C-0r Scenarios for S stem 1ill id 11�1 ,Atti Duet D c S ace From i;lo. a Descr • #;on Location Ceili Leaka e t su a ion Area MDp 1 Supply Attic 16B 0.12 6 532 No 1 Return Attic 16B 0.12 6 591 No E:1SanDiskSecureAccesslRHVACIEXPRESS 1969 ARDEN LUCIE RIGHT 4EDB PG.rh9 Friday, July 14, 2017, 4:10 PM Rtiv'ac w�Resid+ ntiat &pL�g "tfCorrtm�toial HVAE'L°Qads Elite S0 `reaDevglo rneni l 1c: Ftorida, Sreez Metk� mFt: 329.39 Express- o�rden Lucie Righ Pd e 4 Load Preview Report Scope Net Ton ft.2 /Ton Area Sen Gain Lat� Gain Net Gain Sen Loss Sys CFM Sys CFMI Sys Act GF Duct Size Building 3.40 579 1,969 33,585, 7,199 40,784 29,733 363 1,234 1,234 System 1 3,40 579 1,969 33,585 7,199 40,784 29,733 363134", 1,234 15 Supply Duct Latent 329 329 Return Duct 6,452 2,045 8,497 1,772 Zone 1 1,969 27,133 4,825 31,958 27,961 363i''1,23?s, 1,234 i5, 5, 5, 5, 5, 1-First Floor 784 14,327 1,970 16,297 18.482 240 - _652652 5,5,5,5,5, 5 5,5,5,5,5, 2-Second Floor 1,185 12,806 2,855 15,661 9,479 123 583t 583 5,5,5,5,5, 55 E:\SanDiskSecureAccess\RHVAC\EXPRESS 1969 ARDEN LUCIE RIGHT 4EDB PG.rh9 Friday, July 14, 2017, 4:10 PM Rhvac 'Resientiat Elite,Software"$De etopment, lnc' { y Fi3rtia,Brezey ,�*s� c Bpi r �, jd lnress Arden acre Rs ht •u f £ ` A. L'.e. �,a.. �z° w ' w d :Ml art: T YM a . �zf f ,�!'5 ,".y�.$` d1 , Je,j„�',�w�`#"93� a�` Total Building Summary Loads Canapone`�t AreajimSeri L�at S'en To al Descri,tQ�r� Quan Loss. Gain Ganz Gain 2A-v-o: Glazing -Double pane low-e (e = 0.60), operable 146.8 1,401 0 2,489 2,489 window, vinyl frame, u-value 0.34, SHGC 0.35 2A-v-d: Glazing -Double pane low-e (e = 0.60), sliding 40.8 651 0 740 740 glass door, vinyl frame, u-value 0.57, SHGC 0.32 2A-v-o: Glazing -Double pane low-e (e = 0.60), operable 2.5 38 0 57 57 window, vinyl frame, u-value 0,55, SHGC 0.56 11J: Door -Metal - Fiberglass Core 41.2 692 0 766 766 13AB-Ofcs: Wall -Block, no blanket or board insulation, 776.7 3,979 0 3,184 3,184 filled core, siding finish 12C-Osw: Wall -Frame, R-13 insulation in 2 x 4 stud 1342 3,420 0 3,235 3,235 cavity, no board insulation, siding finish, wood studs 166-38: Roof/Ceiling-Under Attic with Insulation on Attic 1969 1,434 0 2,815 2,815 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation 22A-pm: Floor -Slab on grade, No edge insulation, no 129 4,262 0 0 0 insulation below floor, any floor cover, passive, heavy _dry or light wet soil Subtotals for structure: 15,877 0 13,286 13,286 People: 6 1,200 1,380 2,580 Equipment: 1,075 5,701 6,776 Lighting: 0 0 0 Ductwork: 9,656 2,374 11,658 14,032 Infiltration: Winter CFM: 136, Summer CFM: 71 4,200 2,550 1,560 4,110 Ventilation: Winter CFM: 0, Summer CFM: 0 _ _ 0 0 _ _ 0 _ _ 0_ Total Building Load Totals: 29,733 7,199 33,585^� 40,784 -011, kO`E TMes , i Total Building Supply CFM: 1,234 CFM Per Square ft.: 0.627 Square ft. of Room Area: 1,969 Square ft. Per Ton: 579 Volume (ft'): 16,379 Total Heating Required Including Ventilation Air: 29,733 Btuh 29.733 MBH Total Sensible Gain: 33,585 Btuh 82 % Total Latent Gain: 7,199 Btuh 18 % Total Cooling Required Including Ventilation Air: 40,784 Btuh 3.40 Tons (Based On Sensible + Latent) Notesra Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. r E:1SanDiskSecureAccess\RHVACIEXPRESS 1969 ARDEN LUCIE RIGHT 4EDB PG.rh9 Friday, July 14, 2017, 4:10 PM Rhvac ,dsld6Otial,& Light -Commercial HVAG Loads '- � � ,r it ,, mant'rinc;: 7.�,..ysl,.n aY 1 t r{ h .,yki 3+s M9 '. !i* S,�JY. Y k :xb`c }tJ7i4 a*It+t{ yF ,. EY1N "9.d,�.p9.i MYt.1.,. p A'a. q..MY f H.t'�..�..,Iy.{g '} ,r '!�' ...,'i�.lR>d'q'�`Rw*. 'i,A`.ki.i`�I.,M I,..n. 1 Igr�tla Breeze Sr r.:x dte qa a} rfjk'W' en i-uc�eXRigr ig a ray , , , i �$Express,Ar AeAc System 1 Whole House Summary Loads ililkVCorhponent Are Se' t_at Se Total D�s,Grr tlon Quan Loss Gain Gain Ga,n 2A-v-o: Glazing -Double pane low-e (e = 0.60), operable 146.8 1,401 0 2,489 2,489 window, vinyl frame, u-value 0.34, SHGC 0.35 2A-v-d: Glazing -Double pane low-e (e = 0.60), sliding 40.8 651 0 740 740 glass door, vinyl frame, u-value 0.57, SHGC 0.32 2A-v-o: Glazing -Double pane low-e (e = 0.60), operable 2.5 38 0 57 57 window, vinyl frame, u-value 0.55, SHGC 0.56 11J: Door -Metal - Fiberglass Core 41.2 692 0 766 766 13AB-0fcs: Wall -Block, no blanket or board insulation, 776.7 3,979 0 3,184 3,184 filled core, siding finish 12C-Osw: Wall -Frame, R-13 insulation in 2 x 4 stud 1342 3,420 0 3,235 3,235 cavity, no board insulation, siding finish, wood studs 16B-38: Roof/Ceiling-Under Attic with Insulation on Attic 1969 1,434 0 2,815 2,815 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation 22A-pm: Floor -Slab on grade, No edge insulation, no 129 4,262 0 0 0 insulation below floor, any floor cover, passive, heavy dry or light wet soil Subtotals for structure: 15,877 0 13,286 13,286 People: 6 1,200 1,380 2,580 Equipment: 1,075 5,701 6,776 Lighting: 0 0 0 Ductwork: 9,656 2,374 11,658 14,032 Infiltration: Winter CFM: 136, Summer CFM: 71 4,200 2,550 1,560 4,110 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 System 1 Whole House Load Totals: 29,733 7,199 33,585 40,784 FORAP � u', 0" i Supply CFM: 1,234 CFM Per Square ft.: 0.627 Square ft. of Room Area: 1,969 Square ft. Per Ton: 579 Volume (ft'): 16,379 -St stetLoaris;A„ Total Heating Required Including Ventilation Air: 29,733 Btuh 29.733 MBH Total Sensible Gain: 33,585 Btuh 82 % Total Latent Gain: 7,199 Btuh 18 % Total Cooling Required Including Ventilation Air: 40,784 Btuh 3.40 Tons (Based On Sensible + Latent) 1Q701f s F b+ ,riei r, $. Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. E:1SanDiskSecureAccess\RHVACIEXPRESS 1969 ARDEN LUCIE RIGHT 4EDB PG.rh9 Friday, July 14, 2017, 4:10 PM Equipment Data - System 1- Whole House Cooling System Type: Outdoor Model: Indoor Model: Tradename: Outdoor Manufacturer: Description: AHRI Reference No.: Capacity: Efficiency: Heating System Type: Model: Tradename: Manufacturer: Description: Capacity: Efficiency: Air Source Heat Pump 25HBC542A**30 FV4CN6006 CARRIER AIR CONDITIONING CARRIER AIR CONDITIONING Air Source Heat Pump 3646152 45133 16 SEER Air Source Heat Pump 25HBC542A**30 CARRIER AIR CONDITIONING CARRIER AIR CONDITIONING Air Source Heat Pump 42000 9 HSPF This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 95F, SOWB: 78F, WODB: 42F, SIDS: 75F, SIRH: 50%, WIDB: 70F, Sen. gain: 33,585 Btuh, Lat. gain: 7,199 Btuh, Sen. loss: 29,733 Btuh, Entering clg. coil DB: 79.7F, Entering c)g. coil WB: 64.6F, Entering htg. coil DB: 65.6F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 1234 CFM, Req. htg. airflow: 363 CFM E:\SanDiskSecureAccesslRHVAC\EXPRESS 1969 ARDEN LUCIE RIGHT 4EDB PG.rh9 Friday, July 14, 2017, 4:10 PM ;Rhva��' Resldent►�tf;&�LigiZtGorr►riie Vial 6J1d`q'��laads�3, �� � '` �� ��-4, 'Flonda��Bre a � _` „ ,w "Eiife &d "ar'r�'Developr,�antliic. Exp es �ttett t_ticl fight a _ S stem 1 Room Load -Summary F-Itg Mi R�'n .a Ctg Cig Mi Act ciom Are Sens 9 Duct D ct Se s Lat C g Sys No Marne S Btuh CFM Siz Val Btuh B u CFM CFM. ---Zone 1--- 1 First Floor 784 18,482 240 5,5,5,5, - 14,327 1,970 652 652 5,5,5,5, 5,5,5 2 Second Floor 1,185 9,479 123 5,5,5,5, - 12,806 2,855 583 583 5,5,5,5, -- 5,5,5,5— Duct Latent _ 329 _Return Duct 1,772 6,452__ _ _ System 1 total 1,969 29,733 363_ 7,199 1,234 1,234 _ System 1 Main Trunk Size: 15 in. _33,585 Velocity: 1,008 ft./min Loss per 100 ft.: 0.093 in.wg Duct size results above are from Manual D Ductsize. Runout duct velocities are not printed with duct size results from Manual D Ductsize since they can vary within the room. See the Manual D Ductsize report for duct velocities and other data. otiin ste Sig ��ax Cooling Sensibie/La ent Se tole Laten fi 1 `ions S GG Stu Btu i3 uhk Net Required: 3.40 82% / 18% 33,585 7,199 40,784 Actual:' 3.76 90% / 10% 40,589 4,544 45,133 _ W° , entDdta Heating System Cooling System Type: Air Source Heat Pump Air Source Heat Pump Model: 25HBC542A**30 25HBC542A**30 Indoor Model: FV4CNB006 Brand: CARRIER AIR CONDITIONING CARRIER AIR CONDITIONING Description: Air Source Heat Pump Air Source Heat Pump Efficiency: 9 HSPF 16 SEER Sound: 0 0 Capacity: 42,000 Btuh 45,133 Btuh Sensible Capacity: n/a 40,589 Btuh Latent Capacity: n/a 4,544 Btuh AHRI Reference No.: n/a 3646152 This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 95F, SOWB: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDB: 70F, Sen. gain: 33,585 Stuh, Lat. gain: 7,199 Btuh, Sen. loss: 29,733 Btuh, Entering clg. coil DB: 79.7F, Entering clg. coil WB: 64.6F, Entering htg. coil DB: 65.6F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. cig, airflow: 1234 CFM, Req. htg. airflow: 363 CFM E:\SanDiskSecureAccess\RHVAC\EXPRESS 1969 ARDEN LUCIE RIGHT 4EDB PG.rh9 Friday, July 14, 2017, 4:10 PM County, Town, Municipality, Jurisdiction Header Information REQUIRED ATTACHMENTS' Manual J1 Form (and supporting worksheets): or MJ1AE Formz (and supporting worksheets): OEM performance data (heating, cooling, blower): Manual D Friction Rate Worksheet: Duct distribution system sketch: Home Address (Street or Lot#, Block, Subdivision) Desiqn Conditions Winter Design Conditions Outdoor temperature 42 OF Indoor temperature - 70 OF Total heat loss 29733 Btu/h Summer Design Conditions Outdoor temperature 95 OF Indoor temperature 75 OF Grains difference 53 A Gr @ 50 % Rh Sensible heat gain 33585 Btu/h Latent heat gain 7199 Btu/h Total heat gain L0784. Btu/h Heating. E uipment Data Equipment type Heat pump Furnace, Heat pump, Sailer, etc. Model 25HBC542A**30 Form RIPER 1.01 8 Mar 10 ATTACHED Yes QX No Yes ❑ No QX Yes QX No Yes ❑ No ❑X Yes ❑ No Q Building Construction Information Building Orientation (Front door faces) South North, East, West, South, Northeast, Northwest, Southeast, T.uthwest Number of bedrooms 5 Conditioned floor area 1 969 Sq Ft Number of occupants 6 Windows Eave overhang depth Internal shade Blinds, drapes, etc Number of skylights Cooling Equipment Data Equipment type Heat pump Air Conditioner, Heat pump, etc Model 25HBC542A**30 Heating output capacity 42000 Btu/h Sensible cooling capacity Heat pumps - capacity a! winter design outdoor conditions Latent cooling Capacity Auxiliary heat output capacity Btu/h Total cooling capacity Design airflow External Static Pressure (ESP) A114— wc�8aa,� Contractor Florida Breeze Mechanical License # CAC1814113 Building Plan # 1237 CFM 0.32 Iwc Component Pressure Losses (CPL) 0 25 lwc Available Static Pressure (ASP) 0.073 iwc ASP = ESP - CPL 40589 Btu/h 4544 Btu/h 45133 Btu/h Longest supply duct: 60 Ft Longest return duct: _ n Ft Total Effective Length (TEL) 90 Ft Friction Rate: 0.08 IWC Friction Rate = (ASP ■ 100) - TEL Ft Rlrmvehr rl,+n Roof Eave Depth Window Heating CFM 1446 CFM Cooling CFM 1._446 CFM Duct Materials Used (circle) Trunk Duct: Duct board Flex, Sheet metal, Lined sheet metal, Other (specify) Branch Duct: Duct board, lex sheet metal, Lined sheet metal, Other (specify) Contractor's Printed Name Kristin Kell/ Date 1 /10/2016 Contractor's Signature ' The AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors, see list on page 2 of instructions. If abridged version of Manual J is used for load calculation, then verify residence meets requirements, see Abridged Edition Checklist on page 13 of instructions. Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program. Air Conditioning Contractors of America Manual S (Residential Equipment Selection) M Project Information Cooling Design Information Name: Outdoor Design Temp: 91 °F db Summer City: Outdoor Design Temp: 43 °F db IWinter State: E_1 Altitude: = Altitude Adjustment: 1 _0_0_1 Indoor Design Temp: 75 °F db 50 %RH 63 °F wb Manual u Low caicuiaaons Total Load Sensible Latent SHR Heat Loss 40784 33585 7199 0.823 Airflow Calculations Design TD for Airflow F78 Design Sensible CFM F 1696 OEM Information Manufacturer: Icarder Furnace Model #: AFUE: Coil or Fan -Coil Model #: JFV4CNF006T00 Condenser Model #: 125HBC542000 SEER: 16.0 HSPF: 9.00 (A) Manufacturer's Cooling Performance Data Lower Return Air Outdoor Temperature = 95 (F db) Entering Coil Temperature = 75 (F db) CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR Rated CFM @ Rated RA Temperature F 67 45,650 31,320 14,330 0.686 Rated CFM @ Design RA Temperature F 1225 63 42,218 35,720 6,498 0.846 Rated CFM @Rated RA Temperature 62 41,360 36,820 4,540 0.89 (B) Manufacturer's Cooling Performance Data Higher Return Air Outdoor Temperature F 95 (F db) Entering Coil Temperature = 75 (F db) CFM IF wb) Total BTUH Sensible BTUH Latent BTUH SHR Rated CFM @Rated RA Temperature fi7F 47.450 35,190 F 127260 FO.742 44,074 40,510 3.564 0.919 Rated CFM @ Rated RA Temperature 62 43.230 41,840 1,390 0.968 wauu�acwic� s wuwiy renonnan[;e ua[a tm[erpoia[ea1 ----- Design Return Air Outdoor Temperature = 95 (F db) CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR 43,244 1, 990 0.958 Excess Latent Capacity Calculation + -2,655 - -2,655 Capacity @ Design CFM I RA (F wb) 1696 63 45,133 40,589 4,544 0.899 Equipment Capacity as a % of Design 110.66% 120.85% 63.12°/a Manufacturers Heat Pump Data Capacity Capacity Balance Supplemental @ 4 7 °F db � @ 17db PointHeat Required 41,790 �°F 24,580 25.8 15.87 � Manufacturer's Furnace Data Input Output Desired Calculated Capacity Capacity AFUE Temp. Rise Airflow C� �7 I C P _a Y . 4 r•`� . �i t.d..