HomeMy WebLinkAboutProject Specificationsi DRAWING INDEX SHEET SHEET TITLE 01 GENERAL NOTES 02, 02A STRUCTURE/FOUNDATION PLANS 03 SUPPLEMENTAL DETAILS 04 SUPPLEMENTAL DETAILS 18 "MIGIMS FIL"Im: Coarry A. DESIGN CRITERIA 1.0 REFERENCED STANDARDS 1.1 FLORIDA BUILDING CODE, 5TH EDITION 1.2 ASCE 7-10 1.3 ASTM SPECIFICATIONS FOR CONCRETE 1.4 ACI 318-LATEST EDITION FOR STRUCTURAL CONCRETE 1.5 ADM 2010 1.6 AA ASM35, AA ADM 1 2.0 DESIGN LOADS 2.1 DEAD LOADS: MEMBER SELF -WEIGHT 2.2 LIVE LOADS: 300 LB VERT. LOAD ON PRIMARY MEMBERS 200 LB VERT LOAD ON PURLINS 2.3 DESIGN WIND SPEED PER F.B.C., CH. 16 LATEST EDITION Vult: 150 M.P.H. Vasd: 116 M.P.H. 2.4 RISK CATEGORY: 1 2.5 EXPOSURE CATEGORY: B 2.6 WIND LOADS PER F.B.C. TABLE 2002.4 (MWFRS) FOR 20x20x0.013" MESH SCREEN: HOR PRESSURE ON WINDWARD SURFACES: 31 PSF HOR PRESSURE ON LEEWARD SURFACES: 22 PSF VERT PRESSURE ON SCREEN SURFACES: 09 PSF VERT PRESSURE ON SOLID SURFACES: 25 PSF 2.7 FOR 18x14x0.013 MESH SCREEN, APPLIED FACTOR: 0.88 2.8 FACTOR APPLIED TO ALLOWABLE STRESS DESIGN PRESSURES: 0.6 B. RESPONSIBILITIES 1.0 A LICENSED CONTRACTOR SHALL PERFORM ALL SITE WORK IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC. 2.0 CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISITNG FIELD CONDITIONS AND DIMENSIONS PRIOR TO COMMENCEMENT OF DEMOLITION, CONSTRUCTION AND/OR FABRICATION. THE CONTRACTOR SHALL VERIFY THAT THE HOST STRUCTURE/FOUNDATION IS IN GOOD CONDITION WITH SUFFICIENT STRENGTH TO SUPPORT PROPOSED STRUCTURE. THE ENGINEER OF RECORD IS TO BE CONTACTED IN WRITING FOR CLARIFICATION IF DISCREPANCIES ARISE. 3.0 THE CONTRACTOR IS RESPONSIBLE FOR ALL MEANS AND METHODS ASSOCIATED WITH WORK TO BE COMPLETED. THIS IS TO INCLUDE ALL SHORING AND/OR BRACING REQUIRED FOR COMPLETION OF PROJECT. 4.0 THE ENGINEER SHALL NOT BE RESPONSIBLE FOR DAMAGES CAUSED AS A RESULT OF THE CONSTRUCTION EFFORTS. 5.0 THESE DRAWINGS AND DETAILS HAVE BEEN PREPARED AND ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND/OR MANUFACTURER. CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD PRIOR TO CONSTRUCTION IF SPECIAL SITE CONDITIONS ARISE FOR THE FOUNDATION OR HOST STRUCTURE "IV \ \ \ C. MATERIALS \ V 1 1.0 CONCRETE'/FOUNDATION 1.1 SOIL - J 1.1.1 SO BEARING PRESSURE: ASSUMED 1500 PSF 1.1.2 PRI R TO CONCRETE PLACEMENT, TREAT ENTIRE ACE FOR TERMITES IN ACCORDANCE WI . REQUIREMENTS FOR SUNROOMS. 1.1.3 CONCRETE PLACED OVER A POLY VAPOR SHIELD HERE APPPCABLE. HIRS CH PROPERTY 7988 PLANTATION LAKES DR, PORT ST LUCIE, FL 34986 1.2 CONCRETE 1.2.1 ALL CONCRETE SHALL BE 3000 PSI MINIMUM. 1.2.2 CONCRETE SHALL CONFORM TO ASTM C94 FOR: 1.2.2.1 PORTLAND CEMENT, TYPE 1 - ASTM[ C150 1.2.2.2 3/4" AGGREGATE MAXIMUM - AS ITZ C33 1.2.2.3 AIR ENTRAINING, +/- I % - ASTM C260 1.2.2.4 WATER REDUCING AGENT - ASTM C494 1.2.2.5 CLEAN POTABLE WATER 1.2.2.6 OTHER ADMIXTURES SHALL NOT BE PERMITTED 1.23 ALL SLABS ON GRADE SHALL BE 4" THICK MINIMUM 1.3 REINFORCEMENT 1.3.1 FIBERMESH (3/4" PER CU. YD.) MAY BE USED IN LIEU OF WELDED WIRE MESH IF APPROPRIATE ACI AND ASTM REQUIREMENTS ARE MET. 1.3.2 METAL WELDED WIRE MESH (WWM) SHALL CONFORM' TO ASTM AI85. 1.33 STEEL REINFORCEMENT SHALL BE ASTIV A615 GRADE 60 WITH Fy = 60 KSI (U.O.N.) 1.4 PREPARE AND PLACE CONCRETE IN ACCORDANCE WITH ACI MANUAL STANDARD PRACTICE PARTS 1,2 & 5 ALONG WITH HOT WEATHER CONDITION RECOMMENDATIONS. 1.5 IF UTILIZING AN EXISTING SLAB/FOOTING, CONCRETE SLAB SHALL BE A MINIMUM OF 4" THICK AND VISIBLY FREE OF DETERIORATION, SPALLING OR EXCESSIVE CRACKING. CONTRACTOR TO VERIFY THAT EXISTING FOOTING IS A MINIMUM OF 12" WIDE AND 8" DEEP BELOW EXISTING SLAB. IF NOT, SEE FOOTING DETAILS FOR FOOTING DESIGN MINIMUM REQUIREMENTS. 2.0 ALUIVIINUM 2.1 ALL STRUCTURAL ALUMINUM SHALL BE MIIJ: 2.1.1 EXTRUSIONS: 6005 T5 ALLOY 2.1.2 TUBES: 6063 T6 ALLOY 2.2 STRUCTURAL ALUMINUM DESIGN SHALL CONFORM TO "PART 1-A - SPECIFICATIONS FOR ALUMINU1*vI STRUCTURES - ALLOWABLE STRESS DESIGN" OR "PART 1-B SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN' OF THE LATEST ALUNUNUM DESIGN MANUAL. 2.3 PROVIDE DIELECTRIC SEPARATION WHERE ALUMINUM COMES IN CONTACT WITH STEEL OR PRESSURE TREATED LUMBER 2.4 ACTUAL WALL THICKNESS OF EXTRUDED ALUMINUM MEMBERS SHALL NOT BE LESS THAN 0.040 INCH 2.5 SELF -MATING BEAM SECTIONS TO BE STITCHED WITH #12 SMS SPACED AT 6" ON -CENTER FROM THE ENDS AND 24" ON -CENTER THROUGHOUT THE REMAINDER. 2.6 MINIMUM THICKNESS FOR FORMED SHEET ALUMR" STRUCTURAL WALL PANELS (KICK -PLATES) SHALL BE 0.024". 2.7 18x14x0.013" MESH SCREEN SHALL BE USED UNLESS APPROVED BY THE ENGINEER OF RECORD. 2.8 ROOF BRACING SHALL BE A MINIMUM OF 2"x2"x0.050" 2.9 DOOR LOCATIONS MAY BE DETERMINED INTHE FIELD BY CONTRACTOR. 2.10 FOR PICTURE WINDOW MODIFICATIONS TO EXISTING SCREEN ENCLOSURES, THE CONTRACTOR SHALL VERIFY THE EXISTING SCREEN ENCLOSURE IS IN STRUCTURALLY SOUND CONDITION AND MEETS THE REQUIREMENTS OF THE DETAILS WITHIN THESE PLANS. 2.11 IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE ENCLOSURE SHALL MEET THE FLORIDA BUILDING CODE, RESIDENTIAL SECTION R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS IN ITS ENTIRETY. 2.12 SCREEN ROOM ALUMINUM ROOF SECTIONS (COMPOSITE OR PAN) SHALL BE SELECTED/DESIGNED FOR THE WIND PRESSURE STATED WITHIN THE WIND LOADS SECTION OF THESE GENERAL NOTES. THE SELECTION OF THESE ROOF SECTIONS WAS BASED ON THE SPAN TABLES PUBLISHED AND CERTIFIED BY INDEPENDENT FLORIDA LICENSED ENGINEERS WITH THE UP-TO-DATE N.O.A. RECEIVED JAN 18 2018 ST. Lucie County, Permitting 3.0 FASTENERS 3.1 ALL FASTENERS SHALL COMPLY WITH ASTM A153. 3.2 ALL CONCRETE SCEWS SHALL BE TAPCON, SIMPSON, HILTI, REDHEAD OR APPROVED EQUAL. 3.3 ALL LAG BOLTS SHALL HAVE A MIN. EMBED OF 8x BOLT DIA INTO STRUCTURAL FRAMING. 3.4 USE STAINLESS STEEL TYPE 300 18-8 FOR FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER, UNLESS OTHERWISE NOTED ON PLANS OR MANUFACTURER OF GALVANIZED BOLTS SPECIFIES FOR USE WITH ACE PRESSURE TREATED WOOD. 3.5 THE MIN CENTER TO CENTER SPACING FOR SMS SHALL BE 3/4" AND THE MIN CENTER TO EDGE DISTANCE SHALL BE 1/2" UNLESS OTHERWISE NOTED. 3.6 FOR Ix2 MEMBERS TO MASONRY/CONCRETE USE GALVANIZED 1/4"x2-3/4" TAPCONS OR SIMILAR AT 24" O.C. 3.7 FOR Ix2 MEMBERS TO WOOD FRAME USE #14x2-3/4" WOOD SCREW AT 24" O.C. (TYP.) 3.8 FOR 1x2 MEMBERS TO ALUMINUM USE #10x1-1/2" SMS OR TEK SCREWS AT 24" O.C. (TYP.) 3.9 FOR Ix2 MEMBERS INSTALLED THROUGHOUT AN "OPEN VIEW" OR "PICTURE WINDOW" ASSEMBLY, THE FASTENER SPACING SHALL BE REDUCED TO 12" O.C. MAX. ALUMINUM EXTRUSION DIMENSIONS HOLLOW SECTIONS 2x2 2"x2"x0.050" 2x3 2"x3"x0.050" 2x4 2"x4"x0.050" 2x5 2"x5"x0.050" OPEN -BACK SECTIONS lx2 Vx2"x0.044" Ix3 Vx3"x0.045" SNAP SECTIONS 2x2 2"x2"x0.045" 2x3 2"x3"x0.050" 2 x 4 2" x 4" x 0.045" SELF -MATING SECTIONS (SMB) 2x4 2" x 4" x 0.044" x 0.100" 2x5 2"x5"x0.050"z0.118" 2x6 2" x 6" x 0.050" x 0.120" 2x7 2" x 7" x 0.057" x 0.120" 2 x 8 2" x 8" x 0.072" x 0.224" 2 x 9 2" x 9" x0.082" x 0.224" 2 x 10 2" x 10" x 0.092" x 0.374" ~ 1'Illi WEL rn I `t p: I (941) 456-7535 e: admin@southsunengineering.com w: www.southsunengineering.com CONTRACTOR: TREASURE COAST HOME INIPROVEMENTS, INC. PROPERTY ADDRESS: 7988 PLANTATION LAKES DR PORT ST LUCIE, FL 34986 DATE: 11/30/2017 PROJECT NO: A1702155 SHEET: Sol DRAWING INDEX SHEET SHEET TITLE 01 GENERAL NOTES 02, 02A STRUCTURE/FOUNDATION PLANS__ 03 SUPPLEMENTAL DETAILS 04 SUPPLEMENTAL DETAILS GENERAL NOTES -7)2-ofn A. DESIGN CRITERIA 1.0 REFERENCED STANDARDS 1.1 FLORIDA BUILDING CODE, 5TH EDITION 1.2 ASCE 7-10 1.3 ASTM SPECIFICATIONS FOR CONCRETE 1.4 ACI 318-LATEST EDITION FOR STRUCTURAL CONCRETE 1.5 ADM 2010 1.6 AA ASM35, AA ADM 1 2.0 DESIGN LOADS 2.1 DEAD LOADS: MEMBER SELF -WEIGHT 2.2 LIVE LOADS: 300 LB VERT. LOAD ON PRIMARY MEMBERS 200 LB VERT LOAD ON PURLINS 2.3 DESIGN WIND SPEED PER F.B.C., CH. 16 LATEST EDITION Vult: 150 M.P.H. Vasd: 116 M.P.H. 2.4 RISK CATEGORY: 1 2.5 EXPOSURE CATEGORY: B 2.6 WIND LOADS PER F.B.C. TABLE 2002.4 (MWFRS) FOR 20x200.013" MESH SCREEN: HOR PRESSURE ON WINDWARD SURFACES: 31 PSF HOR PRESSURE ON LEEWARD SURFACES: 22 PSF VERT PRESSURE ON SCREEN SURFACES: 09 PSF VERT PRESSURE ON SOLID SURFACES: 25 PSF 2.7 FOR 18x14x0.0I3" MESH SCREEN, APPLIED FACTOR: 0.88 2.8 FACTOR APPLIED TO ALLOWABLE STRESS DESIGN PRESSURES: 0.6 B. RESPONSIBILITIES 1.0 A LICENSED CONTRACTOR SHALL PERFORM ALL SITE WORK IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL'ORDINANCES, ETC. 2.0 CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISITNG FIELD CONDITIONS AND DIMENSIONS PRIOR TO COMMENCEMENT OF DEMOLITION, CONSTRUCTION AND/OR FABRICATION. THE CONTRACTOR SHALL VERIFY THAT THE HOST STRUCTURENOUNDATION IS IN GOOD CONDITION WITH SUFFICIENT STRENGTH TO SUPPORT PROPOSED STRUCTURE. THE ENGINEER OF RECORD IS TO BE CONTACTED IN WRITING FOR CLARIFICATION IF DISCREPANCIES ARISE. 3.0 THE CONTRACTOR IS RESPONSIBLE FOR ALL MEANS AND METHODS ASSOCIATED WITH WORK TO BE COMPLETED. THIS IS TO INCLUDE ALL SHORING AND/OR BRACING REQUIRED FOR COMPLETION OF PROJECT. 4.0 THE ENGINEER SHALL NOT BE RESPONSIBLE FOR DAMAGES CAUSED AS A RESULT OF THE CONSTRUCTION EFFORTS. 5.0 THESE DRAWINGS AND DETAILS HAVE BEEN PREPARED AND ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND/OR MANUFACTURER. CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD PRIOR TO CONSTRUCTION IF SPECIAL SITE CONDITIONS ARISE FOR THE FOUNDATION OR HOST STRUCTURE. \ \ C. MATERIALS 1.0 CONCRETE'/ FOUNDATION 1.1 SOIL 1.1.1 SO BEARING PRESSURE: ASSUMED- 1500 PSF 1. 1.2 PRI R TO CONCRETE PLACEMENT, TREAT ENTIRE SUBACE FOR TERMITES IN ACCORDANCE WI F.B.C. REQUIREMENTS FOR SUNROOMS. 1.1.3 CONCRETE PLACED OVER A POLY VAPOR SHIELD RE APP ABLE. HIRS CH PROPERTY 7988 PLANTATION LAKES DR, PORT ST LUCIE, FL 34986 1.2 CONCRETE 1.2.1 ALL CONCRETE SHALL BE 3000 PSI MINIMUM. 1.2.2 CONCRETE SHALL CONFORM TO ASTM C94 FOR: 1.2.2.1 PORTLAND CEMENT, TYPE 1 - ASTM C150 1.2.2.2 3/4" AGGREGATE MAXIMUM - ASTM C33 1.2.2.3 AIR ENTRAINING, +/- 1% - ASTM C260 1.2.2.4 WATER REDUCING AGENT - ASTM C494 1.2.2.5 CLEAN POTABLE WATER 1.2.2.6 OTHER ADMIXTURES SHALL NOT BE PERMITTED 1.2.3 ALL SLABS ON GRADE SHALL BE 4" THICK MINIMUM 1.3 REINFORCEMENT 1.3.1 FIBERMESH (3/4" PER CU. YD.) MAY BE USED IN LIEU OF WELDED WIRE MESH IF APPROPRIATE ACI AND ASTM REQUIREMENTS ARE MET. 1.3.2 METAL WELDED WIRE MESH (WWM) SHALL CONFORM' TO ASTM A185. 1.3.3 STEEL REINFORCEMENT SHALL BE ASTM A615 GRADE 60 WITH Fy = 60 KSI (U.O.N.) 1.4 PREPARE AND PLACE CONCRETE IN ACCORDANCE WITH ACI MANUAL STANDARD PRACTICE PARTS 1,2 & 3 ALONG WITH HOT WEATHER CONDITION RECOMMENDATIONS. 1.5 IF UTILIZING AN EXISTING SLABNOOTING, CONCRETE SLAB SHALL BE A MINIMUM OF 4" THICK AND VISIBLY FREE OF DETERIORATION, SPALLING OR EXCESSIVE CRACKING. CONTRACTOR TO VERIFY THAT EXISTING FOOTING IS A MINIMUM OF 12" WIDE AND 8" DEEP BELOW EXISTING SLAB. IF NOT, SEE FOOTING DETAILS FOR FOOTING DESIGN MINIMUM REQUIREMENTS. 2.0 ALUMINUM 2.1 ALL STRUCTURAL ALUMINUM SHALL BE MIN: 2.1.1 EXTRUSIONS: 6005 T5 ALLOY 2.1.2 TUBES: 6063 T6 ALLOY 2.2 STRUCTURAL ALUMI IIUM DESIGN SHALL CONFORM TO PART 1-A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN" OR "PART 1-B - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN" OF THE LATEST ALUMINUM DESIGN MANUAL. 2.3 PROVIDE DIELECTRIC SEPARATION WHERE ALUMINUM COMES IN CONTACT WITH STEEL OR PRESSURE TREATED LUMBER 2.4 ACTUAL WALL THICKNESS OF EXTRUDED ALUMINUM MEMBERS SHALL NOT BE LESS THAN 0.040 INCH 2.5 SELF -MATING BEAM SECTIONS TO BE STITCHED WITH #12 SMS SPACED AT 6" ON -CENTER FROM THE ENDS AND 24" ON -CENTER THROUGHOUT THE REMAINDER. 2.6 MINIMUM THICKNESS FOR FORMED SHEET ALUMINUM STRUCTURAL WALL PANELS (KICK -PLATES) SHALL BE 0.024". 2.7 18x14x0.013" MESH SCREEN SHALL BE USED UNLESS APPROVED BY THE ENGINEER OF RECORD. 2.8 ROOF BRACING SHALL BE A MINIMUM OF 2"x2"x0.050" 2.9 DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY CONTRACTOR 2.10 FOR PICTURE WINDOW MODIFICATIONS TO EXISTING SCREEN ENCLOSURES; THE CONTRACTOR SHALL VERIFY THE EXISTING SCREEN ENCLOSURE IS IN STRUCTURALLY SOUND CONDITION AND MEETS THE REQUIREMENTS OF THE DETAILS WITHIN THESE PLANS. 2.11 IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE ENCLOSURE SHALL MEET THE FLORIDA BUILDING CODE, RESIDENTIAL SECTION R4501.17 RESIDENTIAL- SWIMMING BARRIER REQUIREMENTS IN ITS ENTIRETY. 2.12 SCREEN ROOM ALUMINUM ROOF SECTIONS (COMPOSITE OR PAN) SHALL BE SELECTED/DESIGNED FOR THE WIND PRESSURE STATED WITHIN THE WIND LOADS SECTION OF THESE GENERAL NOTES. THE SELECTION OF THESE ROOF SECTIONS WAS BASED ON THE SPAN TABLES PUBLISHED AND CERTIFIED BY INDEPENDENT FLORIDA LICENSED ENGINEERS WITH THE UP-TO-DATE N.O.A. Q RECEIVED z o W AN 18 2018 5 Wc) U ST. Lucie County, Permitting C° 3.0 FASTENERS 3.1 ALL FASTENERS SHALL COMPLY WITH ASTM A153. 3.2 ALL CONCRETE SCEWS SHALL BE TAPCON, SIMPSON, HILTI, REDHEAD OR APPROVED EQUAL. 3.3 ALL LAG BOLTS SHALL HAVE A MIN. EMBED OF 8x BOLT DIA INTO STRUCTURAL FRAMING. 3.4 USE STAINLESS STEEL TYPE 300 18-8 FOR FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER, UNLESS OTHERWISE NOTED ON PLANS OR MANUFACTURER OF GALVANIZED BOLTS SPECIFIES FOR USE WITH ACE PRESSURE TREATED WOOD. 3.5 THE MIN CENTER TO CENTER SPACING FOR SMS SHALL BE 3/4" AND THE MIN CENTER TO EDGE DISTANCE SHALL BE 1/2" UNLESS OTHERWISE NOTED. 3.6 FOR lx2 MEMBERS TO MASONRY/CONCRETE USE GALVANIZED 1/4"x2-3/4" TAPCONS OR SIMILAR AT 24" O.C. 3.7 FOR lx2 MEMBERS TO WOOD FRAME USE #14x2-3/4" WOOD SCREW AT 24" O.C. (TYP.) 3.8 FOR lx2 MEMBERS TO ALUMINUM USE # 10x1-1/2" SMS OR TEK SCREWS AT 24" O.C. (TYP.) 3.9 FOR lx2 MEMBERS INSTALLED THROUGHOUT AN "OPEN VIEW" OR "PICTURE WINDOW" ASSEMBLY, THE FASTENER SPACING SHALL BE REDUCED TO 12" O.C. MAX. ALUMINUM EXTRUSION DIMENSIONS HOLLOW SECTIONS 2 x 2 2" x 2" x 0.050" 2x3 2"x3"x0.050" 2 x 4 2" x 4" x 0.050" 2x5 2"x5"x0.050" OPEN -BACK SECTIONS l x 2 1" x 2" x 0.044" 1x3 I 1"x3"x0.045" SNAP SECTIONS 2x2 2"x2"x0.045" 2x3 2"x3"x0.050" 2x4 2"x4"x0.045" SELF -MATING SECTIONS (SMB) 2 x 4 2" x 4" x 0.044'-'-x 0.100" 2x5 2" x 5" x 0.050" x 0. 118" 2x6 2" x 6" x 0.050" x 0.120" 2x7 2" x 7" x 0.057" x 0.120" 2 x 8 2" x 8" x 0.072" x 0.224" 2 x 9 2" x 9" x0.082" x 0.224" 2 x 10 2" x 10" x 0.092" x 0.374" IIni N M 44 / ``� =Sy / a a w w -/ � •�� � a� �� 0 _\ Hz \ ` � a ozW a w p: I (941) 456-7535 e: admin@southsunengineering.com w: www.southsunengineering.com CONTRACTOR: TREASURE COAST HOME IMPROVEMENTS, INC. PROPERTY ADDRESS: 7988 PLANTATION LAKES DR PORT ST LUCIE, FL 34986 DATE: 11/30/2017 PROJECT NO: A1702155 SHEET: Sol