A. DESIGN CRITERIA
1.0 REFERENCED STANDARDS
1.1 FLORIDA BUILDING CODE, 5TH EDITION
1.2 ASCE 7-10
1.3 ASTM SPECIFICATIONS FOR CONCRETE
1.4 ACI 318-LATEST EDITION FOR STRUCTURAL CONCRETE
1.5 ADM 2010
1.6 AA ASM35, AA ADM 1
2.0 DESIGN LOADS
2.1 DEAD LOADS: MEMBER SELF -WEIGHT
2.2 LIVE LOADS: 300 LB VERT. LOAD ON PRIMARY MEMBERS
200 LB VERT LOAD ON PURLINS
2.3 DESIGN WIND SPEED PER F.B.C., CH. 16 LATEST EDITION
Vult: 150 M.P.H.
Vasd: 116 M.P.H.
2.4 RISK CATEGORY: 1
2.5 EXPOSURE CATEGORY: B
2.6 WIND LOADS PER F.B.C. TABLE 2002.4 (MWFRS)
FOR 20x20x0.013" MESH SCREEN:
HOR PRESSURE ON WINDWARD SURFACES: 31 PSF
HOR PRESSURE ON LEEWARD SURFACES: 22 PSF
VERT PRESSURE ON SCREEN SURFACES: 09 PSF
VERT PRESSURE ON SOLID SURFACES: 25 PSF
2.7 FOR 18x14x0.013 MESH SCREEN, APPLIED FACTOR: 0.88
2.8 FACTOR APPLIED TO ALLOWABLE STRESS DESIGN
PRESSURES: 0.6
B. RESPONSIBILITIES
1.0 A LICENSED CONTRACTOR SHALL
PERFORM ALL SITE WORK IN ACCORDANCE WITH APPLICABLE
BUILDING CODES, LOCAL ORDINANCES, ETC.
2.0 CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISITNG
FIELD CONDITIONS AND DIMENSIONS PRIOR TO
COMMENCEMENT OF DEMOLITION, CONSTRUCTION AND/OR
FABRICATION. THE CONTRACTOR SHALL VERIFY THAT THE HOST
STRUCTURE/FOUNDATION IS IN GOOD CONDITION WITH
SUFFICIENT STRENGTH TO SUPPORT PROPOSED STRUCTURE.
THE ENGINEER OF RECORD IS TO BE CONTACTED IN WRITING
FOR CLARIFICATION IF DISCREPANCIES ARISE.
3.0 THE CONTRACTOR IS RESPONSIBLE FOR ALL MEANS AND
METHODS ASSOCIATED WITH WORK TO BE COMPLETED. THIS IS
TO INCLUDE ALL SHORING AND/OR BRACING REQUIRED FOR
COMPLETION OF PROJECT.
4.0 THE ENGINEER SHALL NOT BE RESPONSIBLE FOR DAMAGES
CAUSED AS A RESULT OF THE CONSTRUCTION EFFORTS.
5.0 THESE DRAWINGS AND DETAILS HAVE BEEN PREPARED AND
ENGINEERED BASED ON INFORMATION PROVIDED BY THE
CONTRACTOR AND/OR MANUFACTURER. CONTRACTOR SHALL
NOTIFY THE ENGINEER OF RECORD PRIOR TO CONSTRUCTION
IF SPECIAL SITE CONDITIONS ARISE FOR THE FOUNDATION OR
HOST STRUCTURE "IV
\ \ \
C. MATERIALS \ V 1
1.0 CONCRETE'/FOUNDATION
1.1 SOIL - J
1.1.1 SO BEARING PRESSURE: ASSUMED 1500 PSF
1.1.2 PRI R TO CONCRETE PLACEMENT, TREAT ENTIRE
ACE FOR TERMITES IN ACCORDANCE WI . REQUIREMENTS FOR SUNROOMS.
1.1.3 CONCRETE PLACED OVER A POLY VAPOR SHIELD HERE
APPPCABLE.
HIRS CH PROPERTY
7988 PLANTATION LAKES DR, PORT ST LUCIE, FL 34986
1.2 CONCRETE
1.2.1 ALL CONCRETE SHALL BE 3000 PSI MINIMUM.
1.2.2 CONCRETE SHALL CONFORM TO ASTM C94 FOR:
1.2.2.1 PORTLAND CEMENT, TYPE 1 - ASTM[ C150
1.2.2.2 3/4" AGGREGATE MAXIMUM - AS ITZ C33
1.2.2.3 AIR ENTRAINING, +/- I % - ASTM C260
1.2.2.4 WATER REDUCING AGENT - ASTM C494
1.2.2.5 CLEAN POTABLE WATER
1.2.2.6 OTHER ADMIXTURES SHALL NOT BE PERMITTED
1.23 ALL SLABS ON GRADE SHALL BE 4" THICK MINIMUM
1.3 REINFORCEMENT
1.3.1 FIBERMESH (3/4" PER CU. YD.) MAY BE USED IN LIEU OF
WELDED WIRE MESH IF APPROPRIATE ACI AND ASTM
REQUIREMENTS ARE MET.
1.3.2 METAL WELDED WIRE MESH (WWM) SHALL CONFORM'
TO ASTM AI85.
1.33 STEEL REINFORCEMENT SHALL BE ASTIV A615 GRADE 60
WITH Fy = 60 KSI (U.O.N.)
1.4 PREPARE AND PLACE CONCRETE IN ACCORDANCE WITH ACI
MANUAL STANDARD PRACTICE PARTS 1,2 & 5 ALONG WITH
HOT WEATHER CONDITION RECOMMENDATIONS.
1.5 IF UTILIZING AN EXISTING SLAB/FOOTING, CONCRETE SLAB
SHALL BE A MINIMUM OF 4" THICK AND VISIBLY FREE OF
DETERIORATION, SPALLING OR EXCESSIVE CRACKING.
CONTRACTOR TO VERIFY THAT EXISTING FOOTING IS A
MINIMUM OF 12" WIDE AND 8" DEEP BELOW EXISTING SLAB.
IF NOT, SEE FOOTING DETAILS FOR FOOTING DESIGN
MINIMUM REQUIREMENTS.
2.0 ALUIVIINUM
2.1 ALL STRUCTURAL ALUMINUM SHALL BE MIIJ:
2.1.1 EXTRUSIONS: 6005 T5 ALLOY
2.1.2 TUBES: 6063 T6 ALLOY
2.2 STRUCTURAL ALUMINUM DESIGN SHALL CONFORM TO
"PART 1-A - SPECIFICATIONS FOR ALUMINU1*vI STRUCTURES -
ALLOWABLE STRESS DESIGN" OR "PART 1-B SPECIFICATIONS
FOR ALUMINUM STRUCTURES - BUILDING LOAD AND
RESISTANCE FACTOR DESIGN' OF THE LATEST ALUNUNUM
DESIGN MANUAL.
2.3 PROVIDE DIELECTRIC SEPARATION WHERE ALUMINUM COMES
IN CONTACT WITH STEEL OR PRESSURE TREATED LUMBER
2.4 ACTUAL WALL THICKNESS OF EXTRUDED ALUMINUM
MEMBERS SHALL NOT BE LESS THAN 0.040 INCH
2.5 SELF -MATING BEAM SECTIONS TO BE STITCHED WITH #12 SMS
SPACED AT 6" ON -CENTER FROM THE ENDS AND 24"
ON -CENTER THROUGHOUT THE REMAINDER.
2.6 MINIMUM THICKNESS FOR FORMED SHEET ALUMR"
STRUCTURAL WALL PANELS (KICK -PLATES) SHALL BE 0.024".
2.7 18x14x0.013" MESH SCREEN SHALL BE USED UNLESS APPROVED
BY THE ENGINEER OF RECORD.
2.8 ROOF BRACING SHALL BE A MINIMUM OF 2"x2"x0.050"
2.9 DOOR LOCATIONS MAY BE DETERMINED INTHE FIELD BY
CONTRACTOR.
2.10 FOR PICTURE WINDOW MODIFICATIONS TO EXISTING
SCREEN ENCLOSURES, THE CONTRACTOR SHALL VERIFY
THE EXISTING SCREEN ENCLOSURE IS IN STRUCTURALLY
SOUND CONDITION AND MEETS THE REQUIREMENTS OF
THE DETAILS WITHIN THESE PLANS.
2.11 IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE
ENCLOSURE SHALL MEET THE FLORIDA BUILDING CODE,
RESIDENTIAL SECTION R4501.17 RESIDENTIAL SWIMMING
BARRIER REQUIREMENTS IN ITS ENTIRETY.
2.12 SCREEN ROOM ALUMINUM ROOF SECTIONS (COMPOSITE
OR PAN) SHALL BE SELECTED/DESIGNED FOR THE WIND
PRESSURE STATED WITHIN THE WIND LOADS SECTION OF
THESE GENERAL NOTES. THE SELECTION OF THESE ROOF
SECTIONS WAS BASED ON THE SPAN TABLES PUBLISHED
AND CERTIFIED BY INDEPENDENT FLORIDA LICENSED
ENGINEERS WITH THE UP-TO-DATE N.O.A.
RECEIVED
JAN 18 2018
ST. Lucie County, Permitting
3.0 FASTENERS
3.1 ALL FASTENERS SHALL COMPLY WITH ASTM A153.
3.2 ALL CONCRETE SCEWS SHALL BE TAPCON, SIMPSON, HILTI,
REDHEAD OR APPROVED EQUAL.
3.3 ALL LAG BOLTS SHALL HAVE A MIN. EMBED OF 8x BOLT DIA
INTO STRUCTURAL FRAMING.
3.4 USE STAINLESS STEEL TYPE 300 18-8 FOR FASTENERS
CONNECTING ALUMINUM COMPONENTS OR PRESSURE
TREATED LUMBER, UNLESS OTHERWISE NOTED ON PLANS
OR MANUFACTURER OF GALVANIZED BOLTS SPECIFIES FOR
USE WITH ACE PRESSURE TREATED WOOD.
3.5 THE MIN CENTER TO CENTER SPACING FOR SMS SHALL BE
3/4" AND THE MIN CENTER TO EDGE DISTANCE SHALL BE
1/2" UNLESS OTHERWISE NOTED.
3.6 FOR Ix2 MEMBERS TO MASONRY/CONCRETE USE
GALVANIZED 1/4"x2-3/4" TAPCONS OR SIMILAR AT 24" O.C.
3.7 FOR Ix2 MEMBERS TO WOOD FRAME USE
#14x2-3/4" WOOD SCREW AT 24" O.C. (TYP.)
3.8 FOR 1x2 MEMBERS TO ALUMINUM USE #10x1-1/2" SMS
OR TEK SCREWS AT 24" O.C. (TYP.)
3.9 FOR Ix2 MEMBERS INSTALLED THROUGHOUT AN "OPEN
VIEW" OR "PICTURE WINDOW" ASSEMBLY, THE
FASTENER SPACING SHALL BE REDUCED TO 12" O.C. MAX.
ALUMINUM EXTRUSION DIMENSIONS
HOLLOW SECTIONS
2x2
2"x2"x0.050"
2x3
2"x3"x0.050"
2x4
2"x4"x0.050"
2x5
2"x5"x0.050"
OPEN -BACK SECTIONS
lx2
Vx2"x0.044"
Ix3
Vx3"x0.045"
SNAP SECTIONS
2x2
2"x2"x0.045"
2x3
2"x3"x0.050"
2 x 4
2" x 4" x 0.045"
SELF -MATING
SECTIONS (SMB)
2x4
2" x 4" x 0.044" x 0.100"
2x5
2"x5"x0.050"z0.118"
2x6
2" x 6" x 0.050" x 0.120"
2x7
2" x 7" x 0.057" x 0.120"
2 x 8
2" x 8" x 0.072" x 0.224"
2 x 9
2" x 9" x0.082" x 0.224"
2 x 10
2" x 10" x 0.092" x 0.374"
~ 1'Illi
WEL
rn I `t
p: I (941) 456-7535
e: admin@southsunengineering.com
w: www.southsunengineering.com
CONTRACTOR:
TREASURE COAST HOME
INIPROVEMENTS, INC.
PROPERTY ADDRESS:
7988 PLANTATION LAKES DR
PORT ST LUCIE, FL 34986
DATE:
11/30/2017
PROJECT NO:
A1702155
SHEET:
Sol
DRAWING INDEX
SHEET
SHEET TITLE
01
GENERAL NOTES
02, 02A
STRUCTURE/FOUNDATION PLANS__
03
SUPPLEMENTAL DETAILS
04
SUPPLEMENTAL DETAILS
GENERAL NOTES
-7)2-ofn
A. DESIGN CRITERIA
1.0 REFERENCED STANDARDS
1.1 FLORIDA BUILDING CODE, 5TH EDITION
1.2 ASCE 7-10
1.3 ASTM SPECIFICATIONS FOR CONCRETE
1.4 ACI 318-LATEST EDITION FOR STRUCTURAL CONCRETE
1.5 ADM 2010
1.6 AA ASM35, AA ADM 1
2.0 DESIGN LOADS
2.1 DEAD LOADS: MEMBER SELF -WEIGHT
2.2 LIVE LOADS: 300 LB VERT. LOAD ON PRIMARY MEMBERS
200 LB VERT LOAD ON PURLINS
2.3 DESIGN WIND SPEED PER F.B.C., CH. 16 LATEST EDITION
Vult: 150 M.P.H.
Vasd: 116 M.P.H.
2.4 RISK CATEGORY: 1
2.5 EXPOSURE CATEGORY: B
2.6 WIND LOADS PER F.B.C. TABLE 2002.4 (MWFRS)
FOR 20x200.013" MESH SCREEN:
HOR PRESSURE ON WINDWARD SURFACES: 31 PSF
HOR PRESSURE ON LEEWARD SURFACES: 22 PSF
VERT PRESSURE ON SCREEN SURFACES: 09 PSF
VERT PRESSURE ON SOLID SURFACES: 25 PSF
2.7 FOR 18x14x0.0I3" MESH SCREEN, APPLIED FACTOR: 0.88
2.8 FACTOR APPLIED TO ALLOWABLE STRESS DESIGN
PRESSURES: 0.6
B. RESPONSIBILITIES
1.0 A LICENSED CONTRACTOR SHALL
PERFORM ALL SITE WORK IN ACCORDANCE WITH APPLICABLE
BUILDING CODES, LOCAL'ORDINANCES, ETC.
2.0 CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISITNG
FIELD CONDITIONS AND DIMENSIONS PRIOR TO
COMMENCEMENT OF DEMOLITION, CONSTRUCTION AND/OR
FABRICATION. THE CONTRACTOR SHALL VERIFY THAT THE HOST
STRUCTURENOUNDATION IS IN GOOD CONDITION WITH
SUFFICIENT STRENGTH TO SUPPORT PROPOSED STRUCTURE.
THE ENGINEER OF RECORD IS TO BE CONTACTED IN WRITING
FOR CLARIFICATION IF DISCREPANCIES ARISE.
3.0 THE CONTRACTOR IS RESPONSIBLE FOR ALL MEANS AND
METHODS ASSOCIATED WITH WORK TO BE COMPLETED. THIS IS
TO INCLUDE ALL SHORING AND/OR BRACING REQUIRED FOR
COMPLETION OF PROJECT.
4.0 THE ENGINEER SHALL NOT BE RESPONSIBLE FOR DAMAGES
CAUSED AS A RESULT OF THE CONSTRUCTION EFFORTS.
5.0 THESE DRAWINGS AND DETAILS HAVE BEEN PREPARED AND
ENGINEERED BASED ON INFORMATION PROVIDED BY THE
CONTRACTOR AND/OR MANUFACTURER. CONTRACTOR SHALL
NOTIFY THE ENGINEER OF RECORD PRIOR TO CONSTRUCTION
IF SPECIAL SITE CONDITIONS ARISE FOR THE FOUNDATION OR
HOST STRUCTURE. \ \
C. MATERIALS
1.0 CONCRETE'/ FOUNDATION
1.1 SOIL
1.1.1 SO BEARING PRESSURE: ASSUMED- 1500 PSF
1. 1.2 PRI R TO CONCRETE PLACEMENT, TREAT ENTIRE
SUBACE FOR TERMITES IN ACCORDANCE WI
F.B.C. REQUIREMENTS FOR SUNROOMS.
1.1.3 CONCRETE PLACED OVER A POLY VAPOR SHIELD RE
APP ABLE.
HIRS CH PROPERTY
7988 PLANTATION LAKES DR, PORT ST LUCIE, FL 34986
1.2 CONCRETE
1.2.1 ALL CONCRETE SHALL BE 3000 PSI MINIMUM.
1.2.2 CONCRETE SHALL CONFORM TO ASTM C94 FOR:
1.2.2.1 PORTLAND CEMENT, TYPE 1 - ASTM C150
1.2.2.2 3/4" AGGREGATE MAXIMUM - ASTM C33
1.2.2.3 AIR ENTRAINING, +/- 1% - ASTM C260
1.2.2.4 WATER REDUCING AGENT - ASTM C494
1.2.2.5 CLEAN POTABLE WATER
1.2.2.6 OTHER ADMIXTURES SHALL NOT BE PERMITTED
1.2.3 ALL SLABS ON GRADE SHALL BE 4" THICK MINIMUM
1.3 REINFORCEMENT
1.3.1 FIBERMESH (3/4" PER CU. YD.) MAY BE USED IN LIEU OF
WELDED WIRE MESH IF APPROPRIATE ACI AND ASTM
REQUIREMENTS ARE MET.
1.3.2 METAL WELDED WIRE MESH (WWM) SHALL CONFORM'
TO ASTM A185.
1.3.3 STEEL REINFORCEMENT SHALL BE ASTM A615 GRADE 60
WITH Fy = 60 KSI (U.O.N.)
1.4 PREPARE AND PLACE CONCRETE IN ACCORDANCE WITH ACI
MANUAL STANDARD PRACTICE PARTS 1,2 & 3 ALONG WITH
HOT WEATHER CONDITION RECOMMENDATIONS.
1.5 IF UTILIZING AN EXISTING SLABNOOTING, CONCRETE SLAB
SHALL BE A MINIMUM OF 4" THICK AND VISIBLY FREE OF
DETERIORATION, SPALLING OR EXCESSIVE CRACKING.
CONTRACTOR TO VERIFY THAT EXISTING FOOTING IS A
MINIMUM OF 12" WIDE AND 8" DEEP BELOW EXISTING SLAB.
IF NOT, SEE FOOTING DETAILS FOR FOOTING DESIGN
MINIMUM REQUIREMENTS.
2.0 ALUMINUM
2.1 ALL STRUCTURAL ALUMINUM SHALL BE MIN:
2.1.1 EXTRUSIONS: 6005 T5 ALLOY
2.1.2 TUBES: 6063 T6 ALLOY
2.2 STRUCTURAL ALUMI IIUM DESIGN SHALL CONFORM TO
PART 1-A - SPECIFICATIONS FOR ALUMINUM STRUCTURES -
ALLOWABLE STRESS DESIGN" OR "PART 1-B - SPECIFICATIONS
FOR ALUMINUM STRUCTURES - BUILDING LOAD AND
RESISTANCE FACTOR DESIGN" OF THE LATEST ALUMINUM
DESIGN MANUAL.
2.3 PROVIDE DIELECTRIC SEPARATION WHERE ALUMINUM COMES
IN CONTACT WITH STEEL OR PRESSURE TREATED LUMBER
2.4 ACTUAL WALL THICKNESS OF EXTRUDED ALUMINUM
MEMBERS SHALL NOT BE LESS THAN 0.040 INCH
2.5 SELF -MATING BEAM SECTIONS TO BE STITCHED WITH #12 SMS
SPACED AT 6" ON -CENTER FROM THE ENDS AND 24"
ON -CENTER THROUGHOUT THE REMAINDER.
2.6 MINIMUM THICKNESS FOR FORMED SHEET ALUMINUM
STRUCTURAL WALL PANELS (KICK -PLATES) SHALL BE 0.024".
2.7 18x14x0.013" MESH SCREEN SHALL BE USED UNLESS APPROVED
BY THE ENGINEER OF RECORD.
2.8 ROOF BRACING SHALL BE A MINIMUM OF 2"x2"x0.050"
2.9 DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY
CONTRACTOR
2.10 FOR PICTURE WINDOW MODIFICATIONS TO EXISTING
SCREEN ENCLOSURES; THE CONTRACTOR SHALL VERIFY
THE EXISTING SCREEN ENCLOSURE IS IN STRUCTURALLY
SOUND CONDITION AND MEETS THE REQUIREMENTS OF
THE DETAILS WITHIN THESE PLANS.
2.11 IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE
ENCLOSURE SHALL MEET THE FLORIDA BUILDING CODE,
RESIDENTIAL SECTION R4501.17 RESIDENTIAL- SWIMMING
BARRIER REQUIREMENTS IN ITS ENTIRETY.
2.12 SCREEN ROOM ALUMINUM ROOF SECTIONS (COMPOSITE
OR PAN) SHALL BE SELECTED/DESIGNED FOR THE WIND
PRESSURE STATED WITHIN THE WIND LOADS SECTION OF
THESE GENERAL NOTES. THE SELECTION OF THESE ROOF
SECTIONS WAS BASED ON THE SPAN TABLES PUBLISHED
AND CERTIFIED BY INDEPENDENT FLORIDA LICENSED
ENGINEERS WITH THE UP-TO-DATE N.O.A.
Q
RECEIVED
z
o W
AN 18 2018 5 Wc)
U
ST. Lucie County, Permitting C°
3.0 FASTENERS
3.1 ALL FASTENERS SHALL COMPLY WITH ASTM A153.
3.2 ALL CONCRETE SCEWS SHALL BE TAPCON, SIMPSON, HILTI,
REDHEAD OR APPROVED EQUAL.
3.3 ALL LAG BOLTS SHALL HAVE A MIN. EMBED OF 8x BOLT DIA
INTO STRUCTURAL FRAMING.
3.4 USE STAINLESS STEEL TYPE 300 18-8 FOR FASTENERS
CONNECTING ALUMINUM COMPONENTS OR PRESSURE
TREATED LUMBER, UNLESS OTHERWISE NOTED ON PLANS
OR MANUFACTURER OF GALVANIZED BOLTS SPECIFIES FOR
USE WITH ACE PRESSURE TREATED WOOD.
3.5 THE MIN CENTER TO CENTER SPACING FOR SMS SHALL BE
3/4" AND THE MIN CENTER TO EDGE DISTANCE SHALL BE
1/2" UNLESS OTHERWISE NOTED.
3.6 FOR lx2 MEMBERS TO MASONRY/CONCRETE USE
GALVANIZED 1/4"x2-3/4" TAPCONS OR SIMILAR AT 24" O.C.
3.7 FOR lx2 MEMBERS TO WOOD FRAME USE
#14x2-3/4" WOOD SCREW AT 24" O.C. (TYP.)
3.8 FOR lx2 MEMBERS TO ALUMINUM USE # 10x1-1/2" SMS
OR TEK SCREWS AT 24" O.C. (TYP.)
3.9 FOR lx2 MEMBERS INSTALLED THROUGHOUT AN "OPEN
VIEW" OR "PICTURE WINDOW" ASSEMBLY, THE
FASTENER SPACING SHALL BE REDUCED TO 12" O.C. MAX.
ALUMINUM EXTRUSION DIMENSIONS
HOLLOW SECTIONS
2 x 2
2" x 2" x 0.050"
2x3
2"x3"x0.050"
2 x 4
2" x 4" x 0.050"
2x5
2"x5"x0.050"
OPEN -BACK SECTIONS
l x 2
1" x 2" x 0.044"
1x3 I
1"x3"x0.045"
SNAP SECTIONS
2x2
2"x2"x0.045"
2x3
2"x3"x0.050"
2x4
2"x4"x0.045"
SELF -MATING
SECTIONS (SMB)
2 x 4
2" x 4" x 0.044'-'-x 0.100"
2x5
2" x 5" x 0.050" x 0. 118"
2x6
2" x 6" x 0.050" x 0.120"
2x7
2" x 7" x 0.057" x 0.120"
2 x 8
2" x 8" x 0.072" x 0.224"
2 x 9
2" x 9" x0.082" x 0.224"
2 x 10
2" x 10" x 0.092" x 0.374"
IIni
N
M
44 /
``� =Sy
/
a a
w w
-/
� •�� � a�
��
0
_\
Hz
\
`
�
a
ozW
a
w
p: I (941) 456-7535
e: admin@southsunengineering.com
w: www.southsunengineering.com
CONTRACTOR:
TREASURE COAST HOME
IMPROVEMENTS, INC.
PROPERTY ADDRESS:
7988 PLANTATION LAKES DR
PORT ST LUCIE, FL 34986
DATE:
11/30/2017
PROJECT NO:
A1702155
SHEET:
Sol