HomeMy WebLinkAboutProduct Evaluation Reportr-�
JB&B Engineering Consultants, LLC
5203 Silver Charm Terrace
Wesley Chapel, FL 33544
Phone: 813-545-1323
Email: TSullivaneng(Mmmail.com
rida Certificateu ho iz ti # 0 03
Product Evaluation Report (R1K _ 4ff(FL #21388.1) 'F0AE'COU
Dynamic 1.0" Nail Strip 24 a e Gal IJB')1�1G>•IIJXSIDN
�9.9 , . - -D dR CQi LIA11 E Mon-HVHZ "
DATE R a
Pi1,AAT 3 PERMIT METST BE ONJIIJB
1.0 Product Manufacturer: Dynamic Metals, LLC OR NO EiSPECTION `ML BE MADE.
3201 SE Dominica Terrace
Stuart, FL 34997
2.0 Code edition: Florida Building Code 5th edition (2014)-Building Volume-Non-HVHZ
Sections 1504.3.2 and 1504.7
3.0 Evaluation Method: Engineering Evaluation (method 1 D) in accordance with 61 G20-3.005 F.A.C.
4.0 Product Category: Roofing
4.1 Product Sub -Category: Metal Roofing
5.0 Product Description:
5.1 General Description: Dynamic 1.0" nailstrip 24 gage steel non structural roof deck
5.2 Fy= 50 ksi
5.3 Panel Thickness: 20 Gage (0.0276") minimum coated thickness
5.4 Corrosion Resistance to comply with Florida Building Code 5th ed. (2014), section 1507.4.3
5.5 Width: 15" maximum coverage
5.6 Rib Height: 1.0" major rib height @ 15" o.c.
6.0 Panel Fastener: #10 x V pancake head fastener through the nail strip 6" from ends and 6" o.c. with
an integral male/female integral snaplock with adhesive. Corrosion resistance per Florida Building Code
5th edition (2014), sections 1506.6 and 1507.4.4
6.1 Substrate Description: 1 layer of 30# organic felt paper or other underlayment compliant
with FBC chapter 15 over minimum 7/16" OSB (or 15/32" 4-ply APA plywood) over 2x SYP rafters
spaced no more than 24" o.c. Substrate must meet all applicable requirements and be designed
with the Florida Building Code 51h edition (2014)
6.2 Design Uplift Pressures:
Field Installation 412.0 psf/2=206.0 psf (Fasteners spaced 6" o.c. And 6" from ends)
7.0 Code Testing Performance Requirements:
7.1 UL 580-06-Test for Uplift Resistance of Roof Assemblies
7.2 UL 1897-04-Uplift Test for Roof Covering Systems
8.0 Performance Test Results Summary:
8.1 Architectural Testing, Inc. West Palm Beach, FL (TST 1527), Report #G11 95.06-450-44
8.1.1 Signed/Sealed by Charles Anderson, P.E. on October 215t, 2016
8.1.2 UL580-06/ UL 1897-04 Field Installation (-412.0.0 psf)
9.0 Installation Instructions:
9.1 Per manufacturer's installation instructions and fastening patterns described herein
Page112
JB&B Engineering Consultants, LLC
5203 Silver Charm Terrace
Wesley Chapel, FL 33544
Phone: 813-545-1323
Email: TSullivaneng(o)_amail.com
Florida Certificate of Authorization #30903
10.0 Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined
using Chapter 16 of the Florida Building Code 2014 for roof cladding wind loads. These component wind
loads for roof cladding are compared to the allowable design pressures listed herein. The design
professional shall select the the appropriate erection details to reference in his drawings for proper fastener
attachment to his/her structure and analyze the panel fasteners for pullout and pullover. Support framing
must be in compliance with Florida Building Code 2014 chapter 22 for steel, chapter 23 for wood and
chapter 16 for structural loading.
11.0 Limits and Conditions of Use:
11.1 Maximum allowable design pressures listed in this report
11.2 Fire classification has not been considered and is outside the scope of this report
11.3 Panels were not evaluated structurally to resist shear diaphragm, axial, transverse or
racking loads
11.4 Alternate conditions not specifically addressed by this approval shall be designed by a
registered Florida Professional Engineer or Architect
11.5 The structural adequacy of the substrate bearing the wind loads superimposed by this
product are the responsibility of others
11.6 Underlayment shall comply with the Florida Building Code 5t' edition (2014)
11.7 Minimum slope shall comply with the Florida Building Code 5th edition (2014, including
section 1507.4.2 and in accordance with the. manufacturers recommendations. For
slopes less than 3:12, lap sealant must be used in the panel side laps
12.0 Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61 G20-3.005(3) for manufacturing under a quality
assurance program audited by an approved quality assurance agency.
13.0 Certificate of Independence: Pursuant to the requirements of 61 G20-3 F.A.C, I hereby certify that
this Florida Professional Engineer, performing this evaluation, does not have nor will acquire an interest in
any company manufacturing or distributing products for which the report is being issued. This is also to
certify that this Florida Professional Engineer, does not have,nor will acquire a financial interest in any
other entity involved in the approval process of this product.
14.0 Certification: In the professional opinion of this evaluating engineer the aforementioned product,
meets the requirer.%l�gtA �f p Florida Building Code 2014 (5th edition), specifically sections 1504.3.2 and
1504.7 for use-i;t�0A6& `@:ZzWe.P utilized within the limits of use noted herein.
o° \ C
n
No 55358
e o
•C10 EUFThom s
o�p
FL PE # D3 8 °°°Bo� AL1 ENGo`°°°o
ooeeaeo�a
Page212
w
JB&'B L:;'NGINEERING, LLC
CONDYNAMIC ,METALS, LLC 5203 Sii"e"Gr m.CharNRS TeErrace
3201 SE Dominica Terrace Wesley Chapel, FL 33644
Stuart, Florida 34997 Phone (813)646-1323
Email"TSullivaneng®gmaii, coin
FL Ceri f'tcate of Authorization #30903
Drawings
Panel Profile
CS
o•
°
41 kYl y°0
°°
S�< °
° e
o °��Ci
-
NS•°��pO
°58
i J
e m
L m
(�
ti41.5 q�
o
. Yf C.
us
E QCOMPLI68 FLORIDA BUILDING CODE 5TH ED. (2014)
NO, 216-1062 I DATE: 10-29-2016
70
NAL
f:''.1VI*I,%ra
MAXIMUM DESIGN UPLIFT PRESSURE=206.0 PSF
ANCHORS TO BE SPACED 6FROM ENDS & 6" O.C.
Client Name: DYNAMIC METALS, LLC
Project Name: DYNAMIC NAIL 1.0" STRIP 24 go STEEL
Project Address: FLORIDA PRODUCT APPROVAL
Florida Building Code Onlir-
Page 1 of 3
�M
/Yt 1 I li
Cusjn,�ss & P-WessionalRegulo,tion
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search
FI dda
1 W Product Approval
pper�.. lt7t USER: Pubilc User
EITye...*. [Jabs
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL # FL21388-R1
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived ❑
Product Manufacturer Dynamic Metals
Address/Phone/Email 3201 SE Dominica Terace
Stuart, FL 34997
(772) 872-8030
juan@dynamicmetal.net
Authorized Signature Juan Martinez
juan@dynamicmetal.net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Thomas D. Sullivan
the Evaluation Report
Florida License PE-55358
Quality Assurance Entity. Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/06/2026
Validated By Joseph A Reed, PE'
L7 Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
FL21388 RI COI FL21388 RO COI Letter of Independence
-Sullivan.odf
Standard Year
UL580 2006
Method 1 Option D
http ://www. floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtD gve0O7nSKOaGD... 1 / 1 /2018
Florida Building Code Onlir
Page 2 of 3
Date Submitted 04/13/2017
Date Validated 04/21/2017
Date Pending FBC Approval 04/21/2017
Date Approved 06/13/2017
Summary of Products
FL #
I Model, Number or Name
Description
21388.1
1" Nailstrip-24 Ga Steel Galvalume
1" Nailstrip, 24 Ga Steel Galvalume non-structural roof panel
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL21388 R1 II Dynamic 1,0 24 gage steel.pdf
Approved for use outside HVHZ: Yes
Verified By: Thomas D. Sullivan 55358
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-206
Evaluation Reports
Other: Fasteners at 6" OC and 6" from ends. Uplift DP
FL21388 R1 AE FL21388.1 Eval Report 1.0 24.odf
Created by Independent Third Party: Yes
equals 206 psf (includes FS=2)
21388.2
1-1/2" Nailstrip-.032 Aluminum
1-1/2" Nailstrip, .032 Aluminum non-structural roof panel
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FI-21388 R1 II 1.5 nailstrio 032 Aliuminum SS.pdf
Verified By: Thomas D. Sullivan 55358
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-168.5
Evaluation Reports
Other: Fasteners 6" OC and 6" from ends
FL21388 R1 AE FL21388.2 Eva] Report 1.5 32 nail
strip.odf
Created by Independent Third Party: Yes
21388.3
1-1/2" Nailstrip-24 Ga Steel
1-1/2" Nailstrip, 24 Ga Steel non-structural roof panel
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL21388 R1 II 1.5 Nailstrip 24 gape steel SS.odf
Verified By: Thomas D. Sullivan 55358
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-153.5
Evaluation Reports
Other: Fasteners 6" OC and 6" from ends
FL21388 R1 AE FL21388.3 Eval Report 1.5 24 nail
strio.pdf
Created by Independent Third Party: Yes
21388.4
1-3/4" Snaplock-.032 Aluminum
1-3/4" Snaplock-.032 Aluminum non-structural roof panel
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL21388 R1 II 1.75 Snaolock 032 Alum SS.odf
Approved for use outside HVHZ: Yes
Verified By: Thomas D. Sullivan 55358
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-f91
Evaluation Reports
Other: Field Installation Uplift DP: clips at 16" OC and
FL21388 RI AE FL21388.4 Eval Report 1.75 32.pdf
Created by Independent Third Party: Yes
4"from ends equals 146 psf (includes FS=2); Corner
Installation Uplift DP: clips at 8" OC and 4" from ends equals
191 psf (includes FS=2)
21388.5
1-3/4" Snaplock-24 Ga Steel
1-3/4" Snaplock, 24 Ga Steel non-structural roof panel
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL21388 R1 II 1.75 Snaolock 24 Gage SS.pdf
Approved for use outside HVHZ: Yes
Verified By: Thomas D. Sullivan 55358
Impact Resistant: N/A
Created by Independent Third Party; Yes
Design Pressure: +N?A/-243
Evaluation Reports
Other: Field Installation Uplift DP: Clips at 16" OC, equals
FL21388 R1 AE FL21388.5 Eval Report 1.75 24.1)df
Created by Independent Third Party: Yes
-176 psf (includes FS=2); Corner Installation Uplift DP: Clips
at 8" OC, equals 243 psf (includes FS=2)
21388.E 5V Crimp-.032 Aluminum 5V Crimp, .032 Aluminum non-structural roof panel
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL21388 R1 II FL21388.6 Drawing 5v 32.pdf
Approved for use outside HVHZ: Yes Verified By: Thomas D. Sullivan 55358
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-183 Evaluation Reports
Other: Fasteners at 12" OC and 6" from ends. Uplift DP of FL21388 R1 AE FL21388.6 Eval Report 5v 32.odf