Loading...
HomeMy WebLinkAboutSolar Improvement Construction DocsA SOLAR PV SYSTEM IMPROVEMENT FOR:0 KAFKA RESIDENCE SOLAR IMPROVEMENT CONSTRUCTION DOCUMENTS FOR THE EXISTING RESIDENTIAL GRID TIED ELECTR"ICAL7� SYSTEM VICINITY MAP INDEX SHEET DRAWING NAME '�+ :�' Yea `_..+• S ,Er CV COVERSHEET 3�sm SLR1 SOLAR SYSTEM EQUIPMENT LOCATION PLAN `� �r 6, °.,�PVR-SS ROOF ATTACHMENT DETAIL - SOLAR ELECTRIC W ' k� g1 �� SLR2 ELECTRICAL 3-LINE DIAGRAM WITH CALCULATIONS �FoRso RIM UyEME }�-------- APPENDIX -- Y 'l. IN HELIENE 30OW MODULE DATA SHEET A�x AP SYSTEMS YC500i MICROINVERTER DATA SHEET BLDG.- DATE: //�� ELEC:�.G .4G4 DATE:�� PLUMB: DATE: MECH: DATE: w w ck: V M Z ui Lu Q in w w 'o IL Q O R C LU w G ::E 0 o Ld zap V Va w w � 0 0 V) d d Li. o r �8 DATE 11/10/2017o DRAWN BY: I JAT CHKD BY: JAT RNO21127 OLSA DRAWING# 11/4 NOT p® ITHOUT 5� I � \ {4P NOV 10 2017 RESIDENTIAL ROOF LAYOUT - WIND ZONES - PV MODULE LAYOUT AND EQUIPMENT LOCATION PLAN SCALE. N.T.S. MATERIALS REQUIRED: (30) HELIENE 30OW MODULES W/ (16) APSYSTEMS YC500i (8) IRONRIDGE MICROINVERTER MOUNTING KITS (NOTE: EACH KIT COMES WITH 2 BOLTS) (2) 17' XRI00 RAIL (8) 14' XR100 RAIL (4) 1 V XR100 RAIL (8) XR-100 INTERNAL BONDED SPLICE KITS (4) GROUNDING LUGS FOR ARRAY CONNECTIONS OF #6 BARE COPPER (70) WIRE MANAGEMENT CLIPS (58) IRONRIDGE L-FOOT WITH LAG SCREWS (16) IRONRIDGE END SLEEVES (16) IRONRIDGE END CAPS FOR RAILS (77) IRONRIDGE GROUNDING UFO CLAMPS (4) APSYSTEMS PAIRS OF MC4 CAPS (3) APSYSTEMS AC TERMINATION CABLES APSYSTEMS EXTENSION CONNECTOR CABLE (1) NEMA 3R RATED ROOF MOUNTED JUNCTION BOXES DISCLAIMER: MATERIALS REQUIRED LIST FOR CONCEPTUAL USE ONLY THE INTENT IS TO AID CONTRACTOR FOR ORDERING REQUIRED MATERIALS FOR THE PROJECT. CONTRACTOR RESPONSIBLE TO VERIFY PRIOR TO SOLAR EQUIPMENT ORDERING. w w Cie V 0 Z w w J 0 Q N w I-- � .0 LL. Q o u- 01 ekev a Q 05 � Y y M w w CC J Lu G Q LL Z Q LLJ ce v� i- ►-w Ce w w a" J--+ � f- O OOpN Cie d 0 DATE 11/10/2017 DRAWN BY: I JAT CHKD BY: JAT REC. NO. # 29127 SCALE I AS NOTED DRAWING # A. ROOF LAYOUT NOTE: L SOLAR PANEL LAYOUT IS CONCEPTUAL, BUT AS PROVIDED, CONFORMS WITH THE REQUIREMENTS SET IN SHEET PVR-SS FOR SPECIFIED ADDRESS. CONTRACTOR MAY ADJUST PANEL LOCATION, BUT SHALL �'.n NOT 00 CONFORM TO THE REQUIREMENTS ON SHEET PVR-SS. SOLID AREAS ON CORNERS OF ROOF ARE WIND N DSO oo ZONE 3 AREAS. AT F ♦ 1 EY ATORRESfE ✓/ RONAL _-4 _ � PHOTOVOLTAIC MODULE GENERAL NOTES: 1. APPLICABLE CODE: 2014 FLORIDA RESIDENTIAL CODE (5TH EDITION) &ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES. 2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER 2014 FLORIDA BUILDING CODE (5TH EDITION) REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A SOUTHER YELLOW PINE (SYP) RESIDENTIAL WOOD ROOF TRUSS AS EMBEDMENT MATERIAL 3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIENTIAL ROOFS, CONSIDERING FROM A 7- TO A MAXIMUM 27" (2/12 TO A MAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. EXISTING RESIDENTIAL ROOF SHALL NOT EXCEED 30'-0" MEAN ROOF HEIGHT. VERIFY IN FIELD. 4, ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511, AND IS THE RESPONSIBILITY OF THE CONTRACTOR TO PILOT FILL ALL HOLES. 5. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO MANUFACTURER MANUAL FOR ALL ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND SOLAR SPECS. 6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESS OTHERWISE NOTED. 7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED. 8. ALL 39" X 65" PV MODULES MAY BE INSTALLED PER THIS STRUCTURAL CONNECTION DRAWING. 9. ALL SOLAR RAILING AND MODULES SHALL BE INSTALLED PER MANUFACTURER INSTRUCTIONS. 10. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2014 FLORIDA RESIDENTIAL CODE (5TH EDITION) OR LOCAL GOVERNING CODE. ULTIMATE WIND ZONE 1 MAX WIND ZONE 2 MAX WIND ZONE 3 MAX EMBED. WIND SPEED SPAN, MAX SPAN , MAX SPAN, MAX DEPTH V,ro(MPH) CANTILEVER CANTILEVER CANTILEVER REQ. 160 4'-0" O.C., V-7" O.C. 4'-0" O.C., V-7" O.C. 2'-0" O.C., 9" O.C. 3- - SCHEDULE REFLECTS COMPONENTS AND CLADDING (C&C) NOMINAL WIND PRESSURES WITH EXPOSURE "B", RISK CATEGORY II , ENCLOSED BUILDING AND h < 60'-0" PER ASCE 7.10 "MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES" AND 2014 F.B.C. * LAG BOLT DEPTH REQUIRED IN WOOD MEMBER EXCLUDES ANY ROOF DECKING THICKNESS. a DIMENSION DEFINED PER ASCE 7-10 SHALL BE 4 FT REGARDLESS AS PER 2014 FLORIDA RESIDENTIAL CODE 5TH EDITION —-------------s—— — — — — — — — — — =---------� i i GABLE END BUILDING 1 HIP END BUILDING ROOF ROOF WIND AREA ZONES WIND AREA ZONES 3— — — — — — — — — 2 _-- ---2--------- I< <I 3 I Q--- (�2-------- I II I I �i ■: I \�`� I mum 14 2 2 PVR3 PVR3 TYPICAL PHOTO LTAI RRAY PITCHED ROOF LAYOUT - WIND ZONES - SCHEDULE - PLAN SCALE: NONE 39" X 65" PHOTOVOLTAIC MODULE TYP. u, w — I n —11 rvn n m i-c nnn Icw^ `MlN1. OLL )%.1:. `-- AJYHALI JHINULtb /METAL 5V ROOF TYP. SCH FOR MAX SPAN REQ. TYPICAL PHOTOVOLTAIC MODULE ARRAY PLAN SCALE: 16"=1'-0" S.Y.P. 2X4 LOCATE BETWEEN TRUSSES AND NAIL WITH 2-16D NAIL PATTERN AT EACH END TO WOOD TRUSS 12" ALUMINUM INTERNAL SPLICE BAR (USE WHEN SPLICE AT MID -SPAN W ® ---- (4) #12-14X5 ST STL SELF ----------------------------------- --- - .__ - TAPPING SCREWS TYP eveeeese.nemee e_ : ---------- - ----- IRONRIDGE XR1000 OR XR100 #12-14X5' ST STL SELF TAPPING ALUM. SOLAR RAIL TYP SCREW TYP 4 PLCS PER BEAM SPLICE TYPICAL SOLAR RAIL BEAM SPLICE DETAIL SCALE: 1 2'=1'-0" 2 PLCS. PER SIDE OF MODULE AND BE CONNECTED < 25% OF MODULE LENGTH. USE ANTI -SEIZE AND. TIGHTEN TO TORQUE PER MANUF. INSTRUCTIONS REFER TO SCHEDULE FOR REQUIRED EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL. ALUMINUM L-FOOT TYP EVERY ROOF PENETRATION e" -16 HEX CAP ST STL BOLT AND ST STL SERRATED FLANGE -NUT TYP. 1 PHOTOVOLTAIC MODULE TYP. b� V3, S END -CLAMP W/ 4" - 20 HEX CAP ST STL BOLT AND ST STL \ —ASPHALT SERRATED SHINGLES / FLANGE -NUT TYP. IRONRIDGE XR1000METAL 5V END -CLAMP SIZE OR XR100 ALUM.OD mg ROOFING TYP. VARIES. SOLAR RAIL TYP.THING 8"ST STL LAG BOLT. SEE ROOF SCH FOR EMBED DEPTH TRUSS TYP. REQ. TYP EACH L-FOOT ASPHALT SHINGLES/ _ TYP_I-CAL-P__V_SOLAR-RAIL END CONNECTION DETAIL 3 METAL 5V ROOFING TYP. SCALE: 1 z"=1'-0" VR3 REFER TO SCHEDULE FOR REQUIRED EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL. aIDbk-STEEL ALL-THRD OD W/ NUT - WASHERS - LOCTITE ALL NUTS TYP. ALL CONNECTIONS OPTIONAL SPANNER CONNECTION DETAILS SCALE: 1 Z =1'-0" ALUMINUM L-FOOT- TYP EVERY ROOF PENETRATION 8' -16 HEX CAP ST STL BOLT AND ST STL SERRATED FLANGE NUT TYP. i PHOTOVOLTAIC MODULE TYP. IRONRIDGE XR1000 OR XR100 ALUM. SOLAR RAIL TYP. WOOD J SHEATHING TYPICAL PV SOLAR SCALE: 1 2"=1'-0" r Y a 0 G; PROJECT- O O o :— O= > �0 a Wo oN z� ~LU NW W J J d 0 �z QVP p N N ch J c === J R W Z C 0 LL � -z<u cx zWW� <,ZOO"n-e >cnOCie ae0 <va- ck-u- DATE:11-10-2017 DRAWN BY: JAT �93 CHKD BY: JAT A RECORD #: 1 29127 SCALE: I AS NOTED CENTER -CLAMP WITH 4° - 20 HEX CAP ST STL BOLT AND (1) ST STL SERRATED FLANGE NUT TYP. SHINGLES —FRONT SIDE BEAM SPLCE@+ METAL 5V LOCATION. SEE TYI`4iAIL WOOD ROOFING 8' ST STL LAG BOLT. SEE SCE ROOF TYP.FOR EMBED. DEPTH REQ. TY2 TRUSS TYP. EACH L-FOOT - RAIL MID CONNECTION DETAIL it �o R� a� DRAWING# 0E !� o N A. j`0. ss WHO�"/RHOU &8w Dsk R / I I ICI 91 0�\\ NOV 10 2017 POWER TABLE: SYSTEM SYSTEM SYSTEM '. GENERAL PHOTOVOLTAIC 3-LINE DIAGRAM SPECIFIC FLAG NOTES: DC -SIDE A B C 1ST BRNCH C 2ND BRNCh C 2ND BRNCH AC -SIDE OBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES PRIOR TO THE COMMENCEMENT OF WORK # PV MODULE 1 1 6 4 6 INVERTER MANUF HIEIENE APSYSIFMSTC5W, MODEL 60M 500 W 3000 W 2000 W 3000 W RATED POWER EQUIPMENT SHALL BE INSTALLED PER THE 2011 NATIONAL ELECTRICAL � CODE (NEC), ALL APPLICABLE OR GOVERNING CODES, MANUFACTURER REQUIREMENTS OF AND PER THE GOVERNING UTILITY COMPANY. POWER PO aoo wP.d� sae w 328 3zee w z19z w 320 a2ee w MAX POWER 39.83 VDc 24D VAC VAC 24D VAC VAC VOLTAGE ISc 2.08A 12ABA 8.32A 12ABA NOM CURRENT VMP 2.28 A 13.68A 9.12 A 13.68A MAX CURRENT LISTING AGENT NAME AND NUMBER SHALL BE INDICATED PER NEC 3 110.3(B). ]W3.14VDC 60 HZ �.� .,,...... 60 HZ ..�.�,..,. 60 HZ _ . 60 HZ FREQUENCY CONDUCTOR WIRE SIZES SHOWN BASED SOLELY ON AMPACITY REQUIREMENTS. TO PREVENT AN INCREASE IN AC VOLTAGE LEVEL AND AVOID ANY NUISANCE FAULTS, IT IS RECOMMENDED TO SIZE CONDUCTOR FOR A TOTAL VOLTAGE DROP OF 2% OR LESS PER INV. MANUFACTURER. LABEL DEVICE PER NEC 690.14(C)(2), AND SECURE PER NEC 690.7(D). LABEL BREAKER PER NEC 690.54, 705.12(D) AND 705.10. BI-DIRECTIONAL (TYP.) UTILITY KWH METER TO UTILITY GRID 120/240 VAC SINGLE PHASE A B TC-ER Z�I- CABLE SYSTEM C INVERTER OUTPUT CIRCUIT CABLE _ OUTDOOR / INDOOR CONDITIONS 4 (9) # 10 AWG CU, INSULATION: THHN/THWN-2 SYSTEM A (3) # 10 AWG CU: IN THHN/THWN-2 IT 1) MODULES/ (6) INVERTERS IS BRANCH CIRCUIT Ar J CONDUIT SIZE: I" MINIMUM ll ATTIC SPACE / WALL INTERIOR RUN ONLY JUNCTION BOX WIRING OPTION TERMINATOR CAP = = NEMA 3R (9) # 10 AWG W/ (3) #10 GROUND EHE INSTALLED ^ ENCLOSURE NM ROMEX CABLE, OF CABLE OR ON END OF TC-ER TC-ER #12 AWG CU 90 C TC-ER #1 AWG CU EQUIVALENT (90"C RATED) CABLE SYSTEM RATED INSULATED CABLE 90 C RAT INSULATED CABLE L1 6 3 5 L2 6 CONTINUOUS #6 AWG CU CONDUCTOR BONDING SOLAR #6 AWG SOLID CU GROUND TYP. RAIL, MODULES, AND AP YCSOOA MICROINVERTER TYP. MICROINVERTERS W/ WEEB G LUGS OR MODULES AND #6 AWG SOLID CU GROUND TYP. 8 20A/2P MICROINVERTERS MAY BRANCH CIRCUIT B TO BE CONNECTED THE SAME L1 BE BONDED TO RAIL WITH SYSTEM B AS BRANCH CIRCUIT A WITH SAME INVERTER WEEB WASHERS, INTEGRATED 07 MODULES/ (4) INVERTERS AND MODULE TYPE ALONG CABLE SYSTEM 20A/2P GROUNDING MID CLAMP OR IN BRANCH CIRCUIT EQUIVALENT TO SIMPLIFY FF L2 INSTALLATION. TC-ER 90 C RATED INSULATED CABLE OA/2P L2 Ll L2 A SYSTEM C BRANCH CIRCUIT C TO BE CONNECTED THE SAME AS BRANCH CIRCUIT A WITH SAME (12) MODULES / (6) INVERTERS INVERTER AND MODULE TYPE ALONG G P1 BRANCH CIRCUIT CABLE SYSTEM TC-ER 90 C RATED INSULATED CABLE NEC 2011 LABELING REQUIREMENTS PHOTOVOLTAIC AC DISCONNECT MAXIMUM AC OPERATING CURRENT: 36.48 A MAXIMUM AC OPERATING VOLTAGE: 240 V (PER NEC 690.54 - PROVIDE AT EXTERNAL AC DISCONNECT OR MAIN SERVICE PANEL IF APPLICABLE) MAIN PV SYSTEM DISCONNECT PER NEC 690.14(2) - PROVIDE AT MAIN SERVICE PANEL G WARNING ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL PER NEC 690.17 - PROVIDE AT MAIN SERVICE PANEL WARNING DEDICATED SOLAR PANEL DO NOT CONNECT LOADS LABEL PER NEC 11031-PROVIDE ATNEWSUB A R N I LNSERVICE PANEL BF REQUIRED) INVERTER OUTPUT CONNECTION - DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL PER NEC 705-12(D)(7) - PROVIDEAT MAIN SERVICE PANEL 0/ I G TO MAIN DISTRIBUTION PANEL LINE SIDE TAP - COMPLY W/ NEC 705.12(A) DISCONNECT OUTPUT CIRCUIT (3) #6 AWG, INSULATION: THHN/THWN-2 CONDUCTOR CONDUIT SIZE: 4"MINIMUM LENGTH OFRUN —10FT 60 AMP FUSED SERVICE RATED DISCONNECT. BOND #8 AWG CU FROM DISCONNECT TO NEW OR EXISTING EARTH NEW 60 AMP DEDICATED SOLAR SUB PANEL r SERVICE PANEL OUTPUT CIRCUIT (3) # 6 AWG, INSULATION: THHN/TH\ (1) # 6 AWG, GROUND CONDUCTOR CONDUIT SIZE: 4" MINIMUM LENGTH OF RUN ^ 10 FT NOTE: MAXIMUM OF 7 INVERTERS PER BRANCH CIRCUIT PER MANUFACTURER RECOMMENDATIONS. WARNING DUAL POWER SOURCE SECOND SOURCE IS PV SYSTEM PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED LABEL PER NEC 705.12(D)(4) - PROVIDE AT MAIN SERVICE PANEL LLJ Lu V � Z Lq Lu U, LLJ N LLJ H .p LL- Q O CT Zr-;L iY Y N M wLii LU � p t- >- Z Q Q W W a: O � Oe cle 0 to d d Li - DATE 1 11/10/2017 DRAWN BY: I JAT CHKD BY: JAT REC. NO. # 29127 SCALE I AS NOTED e�lliilll�e� NOV 10 2017