HomeMy WebLinkAboutEvaluation Report Boral Roof Underlaymentr)0
�l TRINITY ERD
EVALUATION REPORT
Boral Roofing
7575 Irvine Center Drive
Suite 100
Irvine, CA. 92618
FiLEECGP,AN
DESIGN,LLC.o thorizatin U9503 S EET, UNIT 113
OXFORD, CT 06478
PHONE: (203) 262-9245
tr i. F,Ta ^"� r FAX: (203) 262-9243
3 �oEvalu on Report M35710.12.10-R8
DEC O
FL14317-R7
Date of Issuance: 12/21/2010
BY: ....................... Revision 8: 07/01/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 51h Edition (2014) Florida Building Code sections noted herein.
DESCRIPTION: Boral Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 07/01/2015. This does not serve as an electronically signed
document. Signed, sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
f
�l TRINITY I ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is su bject
to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Uplift
UL 1897
2004
1507.2.4, 1507.2.8, 1507.2.9.2, 1507.4.5.1,
Physical Properties
ASTM D1970
2009
1507.4.5.2, 1507.5.3, 1507.5.3.2,1507.6.3,
1507.6.3.2, 1507.7.3, 1507.7.3.2
1507.3.3
Installation Practice
FRSA/TRI April 2012 (04-12)
2012
1523.6.5.2.1
Physical Properties
TAS 103
1995
3. REFERENCES:
Enifty
Examination
Reference
Date
ERD (TST6049)
Wind Uplift
T6460.06.07-R1
10/09/2007
ERD (TST6049)
Physical Properties
T33190.08.30
08/06/2010
ERD (TST 6049)
Physical Properties
M33180.08.10
10/09/2010
ERD (TST6049)
Wind Uplift
T37610.07.11
07/29/2011
ERD (TST 6049)
Physical Properties
840380.08.12
08/28/2012
ERD (TST 6049)
Physical Properties
C41420.09.12-2
09/11/2012
ERD (TST 6049)
Physical Properties
B41940.09.12
09/13/2012
ERD (TST 6049)
Physical Properties
B47390.07.14-1
07/31/2014
ERD (TST 6049)
Physical Properties
847390.09.14
09/04/2014
PRI (TST 5878)
Physical Properties
NEI-006-02-01
04/01/2002
PRI (TST 5878)
Physical Properties
NEI-034-02-02
03/23/2006
PRI (TST 5878)
Physical Properties
NEI-045-02-01
08/08/2007
PRI (TST 5878)
Physical Properties
NEI-053-02-01
05/01/2008
PRI (TST 5878)
Physical Properties
NEI-070-02-01
08/12/2009
PRI (TST 5878)
Physical Properties
NEI-031-02-02:REV 10.27.10
10/27/2010.
PRI (TST 5878)
Physical Properties
NEI-029-02-01REV: 11.03.10
12/03/2010
PRI (TST 5878)
Physical Properties
NEI-046-02-0IREV
12/17/2010
PRI (TST 5878)
Physical Properties
NEI-034-02-02 / MLT-015-02-01
01/29/2013
PRI (TST 5878)
Wind Uplift
BORR-001-02-01
03/17/2015
PRI (TST 5878)
Wind Uplift
BORR-005-02-01
06/24/2015
UL, LLC. (QUA 9625)
Quality Assurance
Service Confirmation, R14610
Exp. 12/10/2017
UL, U.C. (QUA 9625)
Quality Assurance
Cross -Listing Confirmation, R16744
09/04/2013
UL, LLC. (QUA 9625)
Quality Assurance
Service Confirmation, R16744
Exp. 10/13/2017
4. PRODUCT DESCRIPTION:
4.1 Self -Adhering Underlavments:
4.1.1 Boral TileSeal® 5OHT is a nominal 50-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment.
4.1.2 Boral TileSeal® HT is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlaymeht.
4.1.3 GatorSealm is a nominal 55-mil thick, granular -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen roof
underlayment.
4.1.4 StormSentryTM is a nominal 120-mil thick, mineral -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen
roof underlayment.
4.1.5 Citadel® Plus is a nominal 48-mil thick, fabric -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen
roofing underlayment for use as a base -layer in two-ply underlayment systems.
Exterior Research and Design, U.C.
Certificate ofAuthorization #9503
Evaluation Report M35710.12.10-R8
FL14317-R7
Revision 8: 07/02/2015
Page 2 of 6
QCTRRINITYIERD
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation
combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop Boral Roof Underlayments are follows. Table 1 pertains to use of each listed
underlayment by -itself beneath the stated roof covers. Refer to the installation instructions and Table 2 for two-ply
underlayment options.
5.5.1
5.6
5.6.1
5.6.2
5.6.2.1
TABLE 1: ROOF COVER OPTIONS
Underlayment
Asphalt
Nail -On Tile
Foam -On Tile
Metal
Wood Shakes
Slate
Shingles
& Shingles
Boral TileSeal 50"r
Yes
Yes
No
Yes
Yes
Yes
(battens only)
Boral TileSeal"r
Yes
Yes
Yes
Yes.
Yes
Yes
(See 5.5.1)
GatorSeal
Yes
Yes
No
No
Yes
Yes
(battens only)
StormSentry
Yes
Yes
No
No
Yes
Yes
"Foam -On Tile" is limited to use of the following unless tensile adhesion / long term aging data from an accredited
testing laboratory is provided.
Underlayment
Tile Adhesives
3MTM 2-Component Foam Roof Tile Adhesive AH-160 (FL6332)
3MTM Roof Tile Adhesive RTA-1(FL6276)
Boral TileSeal"T
Dow TILE BOND- Roof Tile Adhesive (FL717)
Convenience Products' Touch 'n Seal StormBond Roof Tile Adhesive (FL14506)
Allowable Substrates:
Direct -Bond to Deck:
Citadel Plus, Boral TileSeal 50"T, Boral TileSeal"T, StormSentry or GatorSeal:
➢ Plywood (unprimed or primed with ASTM D41 primer).
Boral TileSeal"T:
➢ OSB primed with ASTM D41 primer.
Wind Resistance of Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
prescriptively addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on the applications. Maximum Design
Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate
passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI
April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads.
Maximum Design Pressure =-105 Psf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Ply: (Optional) Citadel Plus, self -adhered
Underlayment: Boral TileSeal"T self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1X" ring shank
nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
Exterior Research and Design, I.I.C. Evaluation Report M35710.12.10-R8
CertWcate of Authorization #9503 FL14317-117
Revision 8: 07/01/2015
Page 3 of 6
6.
TRINITY 1 ERD
5.6.2.2 Maximum Design Pressure = -202.5 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: ASTM D41 to the plywood deck
Base Ply: (Optional) Citadel Plus, self -adhered
Underlayment: Boral TileSeal"r, self -adhered, and back -nailed within the selvedge -edge side laps using 12 ga. x 1'/<" ring shank
nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
5.6.3 Bond to Base Laver Underlavment:
Citadel Plus, Boral TileSeal 50"T, Boral TileSeal"T or GatorSeal:
➢ ASTM D226, Type II felt; Citadel Plus.
StormSentry:
➢ ASTM D226, Type II felt; Citadel Plus.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1 or as tested in accordance with FBC Section
1504.3.1.
5.6.4 Bond to Other Substrate Types:
Citadel Plus, Boral TileSeal 50"T, Boral TileSeal"T, StormSentry or GatorSeal:
➢ ASTM D41 primed metal (e.g., flashing metal, valley metal, etc).
Boral TileSeal"T:
➢ Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime.
Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval.
5.7 Exposure Limitations:
5.7.1 GatorSeal shall not be left exposed for longer than 30-days after installation, prior to placement of final roof cover.
5.7.2 StormSentry shall not be left exposed for longer than 90-days after installation, prior to placement of final roof cover.
5.7.3 Alcazar, Boral TileSeal 50"T and Boral TileSeal"T shall not be left exposed for longer than 180-days after installation,
prior to placement of final roof cover.
5.7.4 Citadel Plus, for use as a base -layer in a two-ply underlayment system, shall not be left exposed for longer than 180-
days after installation, prior to placement of subsequent underlayment layer.
INSTALLATION:
6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Install self -adhering underlayment when ambient and surface temperatures are minimum 40°F and rising.
6.4 Citadel Plus:
6.4.1 Citadel Plus is limited to use as a base or mid -layer in multi -ply underlayment systems beneath Boral TileSeal 50"T,
Boral TileSeal "T, GatorSeal or StormSentry.
6.4.2 Slope limitations are those associated with the top -layer underlayment.
6.4.3 Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by %-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the
membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a
weighted roller.
Boral recommends fastening of the top edge of the sheet to the deck with roofing nails, nails & tin -tags or 1-inch
diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and
greater. Overlap successive courses minimum 2 inches (horizontal lap) and minimum 4" end (vertical) laps.
Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50"r, Boral
TileSeal"r, GatorSeal or StormSentry.
Exterior Research and Design, I.I.C. Evaluation Report M35710.12.10-R8
Certificate of Authorization #9503 F1.14317-117
Revision 8: 07/01/2015
Page 4 of 6
r`
TRINITY,I ERD
6.4.4 To Base Sheet:
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral
Roofing published installation instructions and Section 6.4.3 and when used as part of a multi -ply system.
Install Citadel Plus as a mid -ply in accordance with Boral Roofing published installation instructions and Section 6.4.3.
Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50"% Boral
TileSeal'T, GatorSeal or StormSentry.
6.5 Boral TileSeal 50"T:
6.5.1 Install Boral TileSeal 50"T in compliance with manufacturer's published installation instructions and the requirements
for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.5.2 Do not use Boral TileSeal 50"T on roof pitches less than 2:12.
6.5.3 Non -Tile Applications, Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by %-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the
membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a
weighted roller.
Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1-inch
diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and
greater. Overlap successive courses the width of the black -selvedge area, minimum 3-inch.
Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam method
detailed in Boral Roofing published installation instructions.
6.5.4 Non -Tile Applications, to Base Sheet:
Install ASTM D226, Type II felt in accordance with Code requirements.
Install Boral TileSeal 50"T in accordance with Boral Roofing published installation instructions and Section 6.5.3, except
end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.5.5 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted
above as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
Battens must be used for all tile installations atop Boral TileSeal 50"T. Boral Roofing's Elevated Batten System' or
counter battens are required for roof pitches of 2 Y,.:12 to less than 4:12.
6.6 GatorSeal and StormSentry:
6.6.1 Install GatorSeal and StormSentry in compliance with manufacturer's published installation instructions and the
requirements for ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be
installed.
6.6.2 Do not use GatorSeal on roof pitches less than 2:12. Do not use StormSentry on roof pitches less than Y2:12 while
ensuring there is no possibility for ponding water on the surface of StormSentry.
6.6.3 Non -Tile applications. Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by %-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the
membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a
weighted roller.
Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1-inch
diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and
greater. Overlap successive courses the width of the black -selvedge area, minimum 3-inch.
Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self -adhering
bituminous underside is in contact with the granular or mineral top surface, rolling the interface into place with a
weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published installation instructions.
Exterior Research and Design, I.I.C. Evaluation Report M35710.12.10-118
CertiTicate ojAuthorization #9503 FL14317-117
Revision 8: 07/01/2015
Page 5 of 6
7
8.
9.
I , j
TRINITY I ERD
6.6.4 Non -Tile Applications. to Base Sheet:
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral
Roofing published installation instructions and Section 6.4.
Install GatorSeal or StormSentry over ASTM D226, Type II felt or Citadel Plus in accordance with Boral Roofing
published installation instructions and Section 6.6.3 except end (vertical) laps, described below.
Apply SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the granular top surface, rolling the interface into place with a weighted roller.
6.6.5 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted
above as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
Battens must be used for all tile installations atop GatorSeal.
6.7 Boral TileSeal "T:
6.7.1 Install Boral TileSeal HT in compliance with manufacturer's published installation instructions and the requirements for
ASTM D1970 underlayments in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.7.2 Do not use Boral TileSeal HT on roof pitches less than 2:12.
6.7.3 Non -Tile Applications, Direct to Deck:
For OSB substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into
manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by %-inch. Fold
the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed
rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller.
Boral recommends fastening of the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1-inch
diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and
greater. Overlap successive courses the width of the black -selvedge area, minimum 3-inch.
Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam method
detailed in Boral Roofing published installation instructions.
6.7.4 Non -Tile Applications, to Base Sheet:
Install ASTM D226, Type 11 felt in accordance with Code requirements or install Citadel Plus in accordance with Boral
Roofing published installation instructions and Section 6.4.
Install Boral TileSeal "T in accordance with Boral Roofing published installation instructions and Section 6.7.3, except
end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.7.5 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted
above as a guideline. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
Battens must be used for all tile installations atop Boral TileSeal "T with roof pitches of 2% to less than 3:12. Boral
Roofing's Elevated Batten System or counter battens are required.
Approved foam adhesive may be used for roof slopes 2:12 and greater.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on plants covered under Rule 61G20-3 QA requirements.
QUALITY ASSURANCE ENTITY:
UL, LLC. — QUA9625; (414) 248-6409; Karen.buchmann@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, U.C. Evaluation Report M35710.12.10-R8
Certificate ofAuthorization #9503 FL14317-R7
Revision 8: 07/01/2015
Page 6 of 6