EVALUATION REPORT
Tacco Roofing
One Information Way, Suite 225,
Little Rock, AR 72202
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of,"Authorization r39503
353 Christian Street, Unit.13
Oxford, CT 06478
PHONE: (263) 262-9245
FAX: (203)262-9243
Evaluation Report T37910.06.11-R3
FL14672-R3
Date of Issuance. 06/23/2011
Revision 3:12/17/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction: materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code. The.product'described herein has been evaluated for compliance with
the 51h Edition (2014) Florida Building:Code sections noted herein.
DESCRIPTION: LeakBarrierO EasyTorch''AModified Bitumen Roof Systems
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is. valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance.of this
Evaluation Report by the named client constitutes. agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TRINITY IERD .Evaluated" may be displayed 'in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or'its
distributors and shall be available for inspectionat the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 4, plus a 4-page Appendix.
'Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facimilie seal appearing was authorized by Robert Nieminen, P.E.
on 12117/201S. This does not serve as an electronically signed
document. Signed, sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research & Design, LLC. d/b/a TrinityJERD does.not have, nor does it intend to acquire or will it acquire, a
financial interest in any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity) ERD is not owned, operated or controlled by any company manufacturing -
or distributing products it evaluates.
3. Robert Nieminen; P.E. does not have nor will acquire; a financial interest in any company manufacturing or distributing
products for which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval
process of the product.
5- This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained.
specifically for that purpose.
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Modified Bitumen Roof Systems
Compliance Statement: LeakBarrier® EasyTorch?"I Modified Bitumen Roof"Systems, as produced by Tarco Roofing,
have demonstrated compliance with, the following -sections of the Florida Building Code through testing in
accordance with the following Standards. Compliance is subject, to the Installation Requirements and Limitations /
Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
"Year
1504.3.1
Wind
FM 4474
2004
1504.7
Impact
FM 4470
1992
1507.11.2
Physical Properties
ASTM D6163
2000
1567.11.2
Physical Properties
ASTM D6222
2008
3. REFERENCES:
Ent
Examination
Reference
Date
ERD (TST6049)
Wind - FM4470/4474
T6460.06.07-R1
10/09/2007
ERD (TST6049)
Wind - FM4470/4474
T36510.05.11
05/12/2011
ERD (TST6049)
Physical Properties
T35450.06.11
06/22/2011
ERD (TST6049)
FM4470
T39050.11.11
11/18/2011
ERD (TST6049)
Physical Properties
T39040.11.11
11/21/2011
ERD (TST6049)
Wind - FM4470/4474
K39690SC
03/07/2012
ERD (TST6049)
Wind - FM4470/4474
TAR-SC5670:14
12/03/2015
ERD (TST6049)
Wind - FM4470/4474
TAR-SC7960.15
12/03/2015
UL (QUA1743)
Quality Assurance
Service Confirmation
Exp. 05/28/2017
4. PRODUCT DESCRIPTION:
This Evaluation Report covers LeakBarrierO EasyTorch'"' Modified Bitumen Roof Systems:installed in"accordance with
Tarco Roofing published installation instructions, and the Limitations / Conditions of Use herein. The following
products make up the subject systems.
p. Tatile:JL: Roil-Goodslor CeakBariier®rEasyT.orch".''Modified Bitumen Roof Systems:
Type
Product
Specification
Reference
Type
Grade
Base Sheets:
LeakBarrier® EasyLay'
ASTM D226
It
N/A
LeakBarrier EasyNailBase'"
ASTM D4601
(published)
II
N/A
Smooth Surfaced Membranes:
LeakBarriere EasyTorch'" SA Base
ASTM D6163
I
S
LeakBarrier® EasyTorch- APP Smooth
ASTM D6222
I
S
Granule Surfaced Membranes:
LeakBarrier` EasyTorch'" APP Granular
ASTM D6222
I
G
Exterior Research and Design; U.C. Evaluation Report T37910.06.11-R3
Certificate of Authorization #9503 f L14672-R3
Revision 3: 12/.1712015
Page 2 of 4
5., LIMITATIONS:
5.1 This is a. building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Report is not for use in HVHZ jurisdictions.
5.3 Refer to a current Roofing Materials Directory for fire ratings of this product.
5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance
with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1. and 2603.6 apply.
5.5 The roof system evaluation herein pertains, to above -deck roof components. Roof .decks and structural
members shall be. in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the
roof deck shall be documented through proper.codified and/or FBC Approval documentation.
5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1510.
5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure
for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with
FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design
professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-
29. Assemblies "marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-
29 for Zone 2/3 enhancements.
5.8 for systems where all components are fully adhered, the maximum design :pressure for the selected
assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No
rational analysis is,permitted for these systems,
5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the
existing deck for withdrawal resistance. ,A qualified design professional shall review the data for comparison
to the minimum requirements for the system., Testing and analysis shall be in accordance with TAS:105 or.
ANSI/SPRI FX-1.
5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the
existing deck or existing roof surface shall be.examined for compatibility with the adhesive to be installed. If
any surface conditions exist that bring system performance into question, field uplift testing in accordance
with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124 shall be conducted on mock-ups of the proposed
new roof assembly.
5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof
system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ,
as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52 or TAS 124.
5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with
FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or RAS 111, except the basic
wind speed shall be determined. from FBC Figure 1609.
5.13 All products in the roof assembly shall have quality assurance audit in accordance with the FBC and F.A.C.
Rule 611320-3.
6. INSTALLATION:
6.1 EasyTorchTM' Modified Bitumen Roof Systems shall be installed in accordance with Tarco Roofing published
installation instructions, subject to the Limitations/ Conditions of Use noted herein.
6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects
the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been
applied). Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, LLC. Evaluailon Report T37910.06:11-113
Certificate of Authorization #9503 FL14672-113
Revision 3: 12/17/2015
Page 3 of 4
7. BUILDING PERMIT REQUIREMENTS:
As required by the 'Building Official or Authority Having Jurisdiction in. order to, properly evaluate the installation of
this product.
$. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing.facilities covered by F.A.C. Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
Underwriters Laboratories — QUA1743; (414) 248-6409 Koren.buchmann@us.ul.com
- THE FOUR (4) PAGES THAT FOLLOMFORM PART OF THIS EVALUATION REPORT -
Exterior Research and Design, LLC: Evaluation Report T379.10.06.11-R3
Certificate of Autharizatlon #9503 FL14672-R3
Revision 1 12/17/2615
Page 4 of 4
APPENDIX I'4 TACHMENT REQUIREMENTS FOR WIND UPUFT RESISTANCE
Table
Deck
Application
Type
Description
Page
1A
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
2
1B
Wood.
New, Reroof (Tear -.Off) or Recover
D
Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
2
SC-1
Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover
3
1C-2
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover
4
SD
Wood
New or,Reroof (Tear -Off)
F
Non -insulated, Bonded Roof Cover
4
2A
Concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
4,
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the
roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements:
Wood Deck: OMG #12 or #14 HD with OMG 3 in. Galvalume Steel Plate orTru-Fast DP or HD with MP-3 Plates. Minimum %-inch plywood penetration or minimum.1-inch wood plank embedment.
3. Unless otherwise"noted, insulation may be anyone layer orcombination of polyisocyanurate, polystyrene, wood fiberboard, perlite or gypsum -based roof board that meets the_ QA requirements of F.A.C. Rule 61G20-
3 and is documented as meeting FBC1505.1 and; forfoam plastic, FBC Chapter 26, when installed with the roof cover.
4. For mechanically attached components orpartfailybonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones'2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly'used methods are RAS 117 and FM LPDS 1-29.
Assemblies marked With an asterlsk* carry the limitations set forth in Section 2:2.1.5.1(a) of FM LPDS 1-29for Zone 2/3 enhancements.
5. For assemblies where all components are fully adhered, -the maximum design pressure for the selected'assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no
rational analysis is permitted:
6. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements forthe system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1,
7, For existing substrates in a;bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own.meritto the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52,
' ANSI/SPRI IA-1 or TAS 124. '
8. "MDP" = Maximum Design'Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, I.I.C. d/b/a Trinity l ERD Evaluation Report T37910.06.11-R3 for FL14672-R3
Certificate of Authorization N9503 Revision 3:'12/17/2015
Prepared -by: Robert Nieminen, PE-59166 Appendix 1, Page 1 of-4
TABLE 1A:.WOOD DECKS — NEWCONSTRUCTION, REROOF-(Tear=Off) or RECOVER
SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER.
System
Deck
Top Insulation Layer
Roof Cover
MDP
No.
{see Note 3)•
Base Insulationaayec
�PsR
Type
Fasteners
Attach
Base Ply
Ply
Cap:
a
SECP-AO4kNO BASE PL'V.;
Nfn:15/32.,
plywood
(Optional) One, or more.
Min. 3/8-inch SECUROCKGypsum-
EasyTorch SA-
(Optional) EasyTorch..
EasyTorch APP Smooth
W-1.
at max. 24"
layers, any
Fiber Roof Board
See Note 2
1 per 1 ft
Base, self
APP Smooth, torch-
or Granular, torch-
-52:5
combination, loose laid
adhering
applied
applied
Min,15/32-" plywood
(Optional) One or more
Min. 2-inch ACFoam II; EnergyGuartl
z
EasyTorch SA
(Optional) EasyTorch
EasyTorch APP Smooth
W-2,
at max. 24" spans
layers; any
Fplyiso ENRGY 3 H-Shield; ISO.95+
See Note 2
1 per 111
Base, self-,
APP Smooth, torch-
or Granular, torch.--
-82.5
'combination, loose laid
GL or Multi-Max;FA3,
adhering
applied
applied
,TOHCH`APPIlEDBASE'PLY _. ` x; '°41
3 �
W-3
-Min.. plywood
{Optional) One or more
layers,
Min..3/8-inchSECUROCK Gypsum-
See Note2
1 z
ffi.'
EasyTorch APP
{Optional) EasyTorch
Smooth, torch-"
EasyTorch APP Smooth
Granular, torch-
=52:5.
at max: 24"
an Y
Fiber Roof Board
per
Smooth, tortih-
APP.
or
combination, loose laid
applied
applied
'applied
TABLE 16: WOOD DECKS.— NEW CONSTRUCTION, REROOF (Tear-Off);or RECOVER
SYSTEM TYPED: ' INSULATED; ,MECHANICALLY ATTACHED BASE SHEET;_BONDED ROOF COVER.
System.
Deck
Insulation. Layer
Base Sheet
Roof,Cover,
MOP
No.
(See Note 1)
Type
Attach
Type . ' -
Fasteners
Attach
Base Ply
Cap
(Rsf)
SEiF-ADHERING BASE PLY'. e
.. ;
Ty
Min. ;15/32" plywood.
A , thickness or
10-inch o c.:irithemin.4-inch'lap and
EasyTorch SA Base,
EasyTorch, APP Srnooth
1N 4.Loose
at max. 24" spans'
Imbl'
-combination
aid
-
Easylay
See Note 2
10 inch o.c in two, equally spaced,
self -adhering
or Granular, torch-
60:0
staggered .center rows
applied ;
Min.:15/32" plywood.
Any type, thickness or
8=inch o.c in the min. 4-inch lap and
EasyTorchSA Base,
EasyTorch APP Smooth
W-5.
of max. 24" spans
n
eombipation
Loose laid
Easylay
See Note 2
Vinch o.c."in four,(4), equally spaced;
self -adhering
or Granular, torch-,
-135.0.
staggered center -rows
applied
Min.15/42" plywood
Any type, thickness or
6-inch o c. in the mih: 4-inch lap and
EasyTorch SA Base,
EasyTorch APP Smooth
'at max. 24"spans
combination
Loose laid ,
EasyNailBase
See Note_ 2
64hch o c, in:four {4), equally spaced;'
self -adhering
or, Granular, torch-
-135.0
staggered center rows
Applied.
Mm,15/32" plywood
An y type, thickness or
6-inch o c .inihe min. 4-inch lap and
EasyTorch APP
EasyTorch' APP Smooth -
7.
EW-
at max: 24"spans,
combination
Loose laid
Ea3 iVailBase
y
See Nofe 2
equally spaced,
6-inch o.c. in four(4),. q y p ced;
Smooth; torch-
or Granular, torch-
t
�-135:0
staggered centerrows
applietl
applied
Exterior Research:and Design, LLC. d/b/a Trinity] ERD Evaluation Report T37910.06.11-R3 fnr FL14672-R3
Certificate afAutharization.0503. Revision,3: 12/17/2015
Preparediby: Robert Nieminen, PE-59166 Appendix 1, Page 2 of 4. .
TABLE 1C-1: WOOD DECKS -NEW CONSTRUCTION or.REROOF (Tear -Off);.
SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (nails), BONDED ROOF COVER
System
Deck
Base Sheet
Roof Cover
MDP
No:
(See Note 1)
(Psf)
Type
Fasteners
Attach
Base Ply
Cap
$Elf-ADHER1t1GB/15EPtY' r
Min. 19/32";plywood
12 ga. annular ring shank nails and min. 32 ga.,
7Anch'o.c. in the 4-.inch lap and 7-inch.o.c.
EasyTcrch,SA Base,
EasyTorch APP'Smooth
W-B.
at max. 24" spans
Easylay
-
1+5/V diameter tin-caips. {Ref: FBC 1517-.5) .
in three; equallyspaced,staggered center
self -adhering
or Granular, torch-
-60.0
rows.
applied
Min: 15/32" plywood
8-inch:o.c. In the min. 4-inch lap and 8-
EasyTorch SA Base,
'EasyTorch APP Smooth
1N 9.
at max. ,24"spans
Eas lay
y
Simplex MAXX Cap Fastener
inch o:c, in four (4), equa11, spaced,
y
self -adhering
or Granular; torch-
-82:5
staggered center rows.
applied
W-10..
Min:15 32" i
plywood
EasyLay
12 ga: annular ring shank nails and min. 32 ga.,
4-inch'o:c inthe 44 chlap and 4=iiich o c.
in four (4), equally spaced, staggered
EasyTorch SA Base,
EasyTorch APP:Smooth -
or Granular, torch-
-120.0.
atmax,.24" spans
1-5/B" diameter tin -caps. (Ref: FBC 1517:5)
center rows
self;adhering
applied
W-11: , .•
Min. plywood
EasyNailBase,
12 ga. anriularring shank nails and"min.32 ga:,
4-inch o i h o
.c in the 4= nchaap and 4-inchO.C.EasyTorch
in five (5), equally spaced, staggered
SA Base,
EasyTorch APP Smooth
or Granular, torch-
-126.0
at max..24' spans'
1-5A' diameter tin -caps. (Ref: FBC 1517.5)
center rows
self -adhering
applied
TORCH AiML1E0
BASE Ply A T x
Min.15/32'plywood
9incho.c in'thetnin•2-Irichlap and .18-'
'.(Optional) EasyTorch
Easy TorchAPP:Smooth
W-12:
aYmax-.24" spans
EasyNailBase-
Simplex MAXX'Cap Fastener `
inch o.c. in two (2), equailyspaced,
APP Smooth, -torch-
or Granular, torch-
-45.0`'
staggered center rows.
applied
applied.
Min.15132" plywood
9-inch o.c. in the min. 2-Inch tap arid,12-
(Optional) EasyTorch
EasyTorch APP Smooth
W-13."
-at max..24" spans
EasyNailftse4
Simplex'MA)X Cap Fastener
inch o.c. in two (2), equally spaced,.
APP Smooth, torch-
or Granular, torch-
752:5 ;
staggered center.rows ,
applied
applied
Min:15/32" plywood
6-inch o.c: in the mm..2-inch lap and 6-
(Optional):EasyTorch
EasyTorch APP Smooth
W-14.
at max.:24,"spans
EasyNailBase•
Simplex MAXX Cap Fastener
inch o.c. in two (2), equallyspaced,
AP•P Smooth, torch
or Granular, torch
90 Os
= staggered center row.'s
applied
applied
Min.15/32" plywood
,6-inch o.c. in the min 2-inch lap and>6-
(Optional)'EasyTorch
EasyTorch APP, Smooth
1N-15,.
of maxr.24- spans
EasyNailBase
Simplex MAXX Cap Fastener
inch o.c. in three (3), equally spaced,
APP Smooth, torch-
or Granular, torch-
-105:0'
staggered,centerroWs
applied
applied
Min.'15/32"plywood
12.ga:.annulavringshank nails and min. 32 ga.;
4-inch o.c. in:the 4-inch lap:and 4-inch o.c.
{Optional)' EasyTorch
EasyTorch APP Smooth
1N-1.6.
atimax.24."`spans
EasyNailBase:
1-5/8"'diametertin-caps.. (Ref: FBC 1517,5)
in five (5), e_qualiy spaced, staggered
APP Smooth; torch-
or Granular, torch-
-120,0,
center rows
applied
'applied
Exterior Research'.and Design, LLC. d/b/a.TrinityI ERD
' Certificate ofAuthorization #9503
Prepared'by: Robert Nieminen, PE-59166
EvaluationReport T3.7910-06.11-R3 for FL14672-R3
Revision 3: 12/17/2015
Appendix 1, Page 3 of 4
s 16
TABLE'1C-2: WOOD DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER
SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (screws & plates), BONDED ROOF COVER
System
Deck
Base Sheet
Roof Cover
MDP
No:
(See Note 1)
Type
Fasteners
Attach
Base Ply
Cap
(psf)
SELFADHERING BASE PLY.
W-17.
Min. 15/32" plywood
fasyLay
See Note 2
10-inch o.c. in the min. 4-inch lap and 10-inch o.c. in two,
EasyTorch SA Base, self-
EasyTorch APP Smooth or
60.0
at max. 24" spans
equally spaced, staggered center rows
adhering.
Granular, torch -applied
W-18.
Min.15/32".plywood
EasLay
See Note 2
&inch o.c. in the min. 4-inch lap and 8-inch o.c. in four (4),
EasyTorch SA Base, self-
EasyTorch APP Smooth or
135.0
at max. 24" spans
equally spaced, staggered center rows
adhering
Granular, torch -applied
V✓-19.
Min.,15/32" plywood
EasyNailBase
See Note 2
6-inch o.c. in the min. 4-inch lap and 6-inch o.c. in four (4),
EasyTorch SA Base, self-
EasyTorch APP Smooth or
135.0
at max. 24" spans
equally spaced, staggered center rows
adhering
Granular, torch -applied
.: TORCH -APPLIED SASE PLY:
W 20
Min.15/32" plywood
EasyMailBase
See Note 2
6-inch o.c. in the min. 4-inch lap and 6-inch o.c. in four (4),
(Optional) EasyTorch APP
EasyTorch APP Smooth or
-135,0
at max. 24" spans
equally spaced; staggered center rows
Smooth, torch -applied
Granular, torch -applied
TABLE 11): WOOD DECKS — NEW CONSTRUCTION or,REROOF,(Tear-Off)
SYSTEM TYPE F: BONOED'ROOF COVER
System
Deck (See WWI)
Roof Cover
MDp-
No.
Type
Joint Treatment
Base Ply
Ply
Cap
(Psf)
W 21.
-Min. plywood
None
EasyTorch SA Base, self-
(Optional) EasyTorch APP
EasyTorch ARP Smooth or
75.0
'at max. 24" spans
adhering
Smooth, torch -applied
Granular, torch -applied
W Z2.
Min. 15/31" plywood
Plywood joints are covered with 4-inch wide strips of EasyBase, rolled into
EasyTorch SA Base, self-
(Optional) EasyTorch APP
EasyTorch APP Smooth or
-120.0
at max. 24" spans
place to create continuous bond'.
adhering
Smooth, torch -applied
Granular, torch -applied
TABLE 2A: CONCRETE DECKS - NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER"
System
Deck
Primer
Roof Cover
MDP
Base Ply
Ply
Cap
No.
(See Note 1)
(Psf)
C-1.
Concrete
ASTM D41
EasyTorch APP Smooth, torch -applied
(Optional) EasyTorch APP Smooth, torch-
EasyTorch APP Smooth or Granular, torch-
-670.0
applied
applied
Exterior Research and Design, I.I.C. d/b/a Trinity( ERD Evaluation Report T3:7910.06.11-R3 for FL14672-R3
Certi)rcateofAuthorization #9503 Revision 3:12/17/2015
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 4 of 4