Loading...
HomeMy WebLinkAboutScope Of Work21'-1" 31'-11" H:\2020 Projects\013 - 2020 Boraclough\Construction Docs 7920\1 site & exist Pl.dwg, 9/10/2020 12:09:35 PM, DWG To PDF.pc3 EXISTING — REMODELED AREA TO BE REPAIRED, ADJUSTED & COMPLETED PE DE EXISTING 3068 SC DOOR UNFINISHED BEDROOM WALL TO BE BEARING SEE NEW FLOOR PLf AND DETAIL ELECTRIC PANEL TO RELOCATED PLUMBING PLACED (I' FI NEW ELECTRIC PANELTURES) LOCATION UNFINISHED CLOSET u I If N UNFINISHED KITCHEN SCREENED COVERED PORCH UNFINISHED M. BATH II�a LLB I UNFINISHED II PDR RM Ir�REPLACE/REPAIR I EXISTING BEAM II II �I UNFINISHED II LIVING I Ir--- REPLACE/REPAIR EXISTING OPENING SEE DETAIL i I � , SEE DETAIL TO AUGMENT AREAS DESIGNATED BY V AT 4" CMU WALL BASE STRUCTURAL PLAN 4 EXISTING/ DEMO FLOOR PLAN SCALE:1/4" = V-0" EXISTING — MINOR FINISH WORK TO BE COMPLETED AND KITCHEN REMOVED EXISTING OPENING TO BE FILLED IN SEE TYP. DETAIL EXISTING BR 3 _L EXISTING KITCHEN TO BE REMOVED EXISTING CEILING TO BE REPAIRED EXISTING LIVING EXISTING 3032 OPENING REMOVE MATERIAL FROM SILL TO FLOOR EXISTING BR 2 EXISTNG BR 1 I EXISTING CASED —� I OPENING I I EXISTING DEN SCOPE OF WORK • NO FOU11DATION WORK REQUIRED • REMODELED AREA TO BE COMPLETED/REPAIRED AND BROUGH`' TO CODE SPECIFICATIONS INCLUDING ENGINEERING AUGMEN iATION OF STRUCTURE AS NOTED • ELECTRICAL TO BE COMPLETED & WILL COMPLY WITH SECTION R404`.1 OF THE 2017 FLORIDA ENERGY CODE • EXISTED AREA TO HAVE MINOR REPAIRS COMLETED AND EXISTING KITCHEN REMOVED AS NOTED NEW HARDIE PLANK SIDING, TRIM & SHUTTERS SCREENED' OPENINGS AREA OF 4" CMU BEHIND EXISTING WINDOW EAST ELEVATION SCALE:1/4" = 1'-0" f\K>=A Ut' 4" VY I IN uu YV CMU BEHIND WEST ELEVATION SCALE:1/4" = 1'-0" NEW WINDOWS TO MATCH EXISTING WINDOWS SOUTH ELEVATION NEW DECORATIVE BRACKETS EXISTING WINDOW SCANN51) 3Y ST LUCIE COUNTY Y �, �.,� o //lll{ili9 \° 0 i WLL co In n E L 0 'mo NQ0 s71 d)aa I WN 0mn y)huw �mm ww 00 NNZO �� NW .n. N08a co 2 LL � a >�L 11 o� �N Q Q V z� 7 Z uu, > w —wz <z Woo cf 66 1° F " — uj,oOD E CofpIJAN E4a STn LnUC9E COUNTY Bocc C) FILE yy 6 >4 Aeli0 O C\2' CD C\2 1' C'7 21'-1 ° EXISTING — REMODELED AREA TO BE REPAIRED, ADJUSTED & COMPLETED PER CODE „l WI EXISTING — MINOR FINISH WORK TO BE COMPLETED AND KITCHEN REMOVED 4030 SH EXISTING +31/-34 2026 SH MASTER SUITE 5068 SC 81—PASS I I W.I.C. I I I I I L J —t—Dw o — R/OI NEW INK KITCHEN i � 32° ICI L — 4 SCREENED COVERED PORCH STRUCTURAL -GENERAL NOTES DESIGN CRITERIA AND LOADS: 1. WIND DESIGN: / 2668 S DOOR NEW ELES PNL K LNDRY Z SINK NEW 2X4 REINFORCEMENT WALL — SEE STRUCTURAL SHEET FOR DETAILS PR FR DINING ROOM 44X32 SH EXISTING FG 3030 SH EXISTING BR 3 ISTI TH i CASED OPENINGS 'i 4032 SH STING AHU OPEN SHEVES EXISTING LIVING 3030 SH EXISTING EXISTING BR 2 EXISTNG BR 1 22X50 SH 3068SC EXISTING \ DOOR OR `K XISTING INFO RMA T/ON PLAN 1 /4" = 1'-0" WIND SPEED (MPH) V(ADJ)=124 V(ULT)=160 RISK CATEGO II EXPOSURE CATEGORY C ENCLOSURE CLASSIFICATION ENCLOSED INTERNAL PRESSURE COEFFICIENT CPI =+/- 0.18 TOPOGRAPHIC FACTOR KZT =1.0 2. DESIGN LIVE LOADS: ROOF LIVE LOAD 20 PSF 3. DESIGN DEAD LOADS: a. ROOF DEAD LOADS: 17 PSF 4. THE CONTRACTOR HAS THE RESPONSIBILITY TO NOTIFY THE STRUCTURAL ENGINEER OF RECORD (SER) OF ANY ARCHITECTURAL, MECHANICAL, ELECTRICAL, OR PLUMBING LOAD IMPOSED ONTO THE STRUCTURE THAT DIFFERS FROM, OR THAT IS NOT DOCUMENTED ON THE ORIGINAL CONTRACT DOCUMENTS (ARCHITECTURAL/ STRUCTURAL/ MECHANICAL/ ELECTRICAL OR PLUMBING DRAWINGS). PROVIDE DOCUMENTATION OF LOCATION, LOAD, SIZE AND ANCHORAGE OF ALL UNDOCUMENTED LOADS IN EXCESS OF 400 POUNDS. PROVIDE MARKED -UP STRUCTURAL PLAN INDICATING LOCATIONS OF ANY NEW EQUIPMENT OR LOADS. SUBMIT PLANS TO THE ENGINEER FOR REVIEW PRIOR TO INSTALLATION. GENERAL REQUIREMENTS 1. PLAN AND DETAIL NOTES AND SPECIFIC LOADING DATA PROVIDED ON INDIVIDUAL PLANS AND DETAIL DRAWINGS SUPPLEMENTS INFORMATION IN THE STRUCTURAL GENERAL NOTES. 2. THE DESIGN AND CONSTRUCTION OF THIS PROJECT IS GOVERNED BY THE "FLORIDA BUILDING CODE (FBC)", SIXTH EDITION, HEREAFTER REFERRED TO AS THE FBC, AS ADOPTED AND MODIFIED BY THE AUTHORITY HAVING JURISDICTION (AHJ). 3. WHERE OTHER STANDARDS ARE NOTED IN THE DRAWINGS, USE THE LATEST EDITION OF THE STANDARD UNLESS A SPECIFIC DATE IS INDICATED. REFERENCE TO A SPECIFIC SECTION IN A CODE DOES NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE ENTIRE STANDARD. +31 /-34 3030 SH +31 /-34 EXISTING DEN I 3043 SH EXISTING 4. REFER TO THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, CIVIL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION INCLUDING BUT NOT LIMITED TO: DIMENSIONS, ELEVATIONS, SLOPES, DOOR AND WINDOW OPENINGS, NON -BEARING WALLS, STAIRS, FINISHES, DRAINS, WATERPROOFING, RAILINGS, CURTAIN WALLS, DEPRESSIONS, MECHANICAL UNIT LOCATIONS, AND OTHER NONSTRUCTURAL ITEMS. 5. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING DETAILS AND ACCURACY OF THE WORK WITH ARCHITECT, ENGINEER(S) AND OTHER TRADES; FOR CONFIRMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS; FOR SELECTING FABRICATION PROCESSES; FOR TECHNIQUES OF ASSEMBLY; AND FOR PERFORMING WORK IN A SAFE AND SECURE MANNER. 6. IN CASE OF DISCREPANCIES BETWEEN THE GENERAL NOTES, SPECIFICATIONS PLAN/DETAILS, REFERENCE STANDARDS, THE ENGINEER SHALL DETERMINE WHICH SHALL GOVERN. SHOULD ANY DISCREPANCY BE FOUND IN THE CONTRACT DOCUMENTS, THE CONTRACTOR WILL BE DEEMED TO HAVE INCLUDED IN THE PRICE THE MOST EXPENSIVE WAY OF COMPLETING THE WORK, UNLESS PRIOR TO THE SUBMISSION OF THE PRICE, THE CONTRACTOR ASKS FOR A DECISION FROM THE ENGINEER AS TO WHICH SHALL GOVERN. ACCORDINGLY, ANY CONFLICT IN OR BETWEEN THE CONTRACT DOCUMENTS SHALL NOT BE A BASIS FOR ADJUSTMENT IN THE CONTRACT PRICE. 7. THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION AND ALL JOB RELATED SAFETY STANDARDS SUCH AS OSHA AND DOSH (DEPARTMENT OF OCCUPATIONAL SAFETY AND HEALTH). 8. THE STRUCTURAL DRAWINGS ARE INTENDED TO SHO W THE GENERAL CHARACTER AND EXTENT OF THE PROJECT AND ARE NOT INTENDED TO SHOW ALL DETAILS OF THE WORK. ARCHITECTURAL DRAWINGS SHALL GOVERN THE WORK FOR ALL DIMENSIONS. 9. ALTERNATE PRODUCTS OF SIMILAR STRENGTH, NATURE AND FORM FOR SPECIFIED ITEMS MAY BE SUBMITTED WITH ADEQUATE TECHNICAL DOCUMENTATION TO THE ENGINEER FOR REVIEW. ALTERNATE MATERIALS THAT ARE SUBMITTED WITHOUT ADEQUATE TECHNICAL DOCUMENTATION THAT SIGNIFICANTLY DEVIATE FROM THE DESIGN INTENT OF MATERIALS SPECIFIED MAY BE RETURNED WITHOUT REVIEW. ALTERNATES THAT REQUIRE SUBSTANTIAL EFFORT TO REVIEW WILL NOT BE REVIEWED UNLESS AUTHORIZED BY THE OWNER. 10. CHANGES AND ADDITIONS MADE ON RE -SUBMITTALS SHALL BE CLEARLY CLOUDED AND NOTED. ENGINEER REVIEW WILL BE LIMITED TO THOSE ITEMS CAUSING THE RE -SUBMITTAL. 11. DISCREPANCIES, OMISSIONS, OR INCONSISTENCIES WITH APPLICABLE CODE REQUIREMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IN WRITING BEFORE SUBMITTING A BID OR PROCEEDING WITH THE WORK. 12. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDItIONS AT THE SITE. CONFLICTS BETWEEN THE DRAWINGS AND ACTUAL SITE CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IN WRITING BEFORE PROCEEDING WITH THE WORK. I ALL ELECTRIC IN PLACE EXISTING 13. THE CONTRACTOR IS RESPONSIBLE FOR THE STRENGTH AND STABILITY OF THE STRUCTURE DURING CONSTRUCTION AND SHALL PROVIDE TEMPORARY SHORING, BRACING AND OTHER ELEMENTS REQUIRED TO MAINTAIN STABILITY UNTIL THE STRUCTURE IS COMPLETE. DO NOT LOAD STRUCTURES, NEW OR EXISTING, WITH WEIGHT THAT WILL ENDANGER STRUCTURE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO BE FAMILIAR WITH THE WORK REQUIRED IN THE CONSTRUCTION DOCUMENTS AND THE REQUIREMENTS FOR EXECUTING IT PROPERLY. DOORS AND WINDOWS 1. THE DESIGN PRESSURES FOR THE DOORS AND WINDOWS SHALL BE NOT LESS THAN THE VALUES SHOWN IN THE PLANS OR SCHEDULE. 2. THE DOORS AND WINDOWS SHALL BE INSTALLED IN STRICT COMPLIANCE WITH THE MANUFACTURER'S NOTICE OF APPROVAL (MIAMI NOA OR FBC APPROVAL). 3. THE DOORS AND WINDOWS MUST WITHSTAND THE IMPACT OF WIND BORNE MISSILES, OR SHALL BE PROTECTED WITH AN APPROVED IMPACT RESISTANT COVERING. 4. EACH UNIT SHALL BEAR A LABEL WITH THE MANUFACTURER'S NAME AND DESIGN PRESSURES. 5. PRIOR TO INSTALLATION, ALL FRAMES MUST BE CHECKED FOR RACK, TWIST AND OUT OF SQUARE. 6. FOLLOW FMA (FENESTRATION MANUFACTURERS ASSOCIATION) GUIDELINES FOR a. CAULK ALL INSIDE CORNERS OF FLASHING ALL OPENINGS. OPENINGS WITH O APPROVED SEALANT. AN APPR b. APPLY AN APPROVED FLASHING TO ALL FOUR SIDES OF OPENINGS. C. APPLY A HEAVY, UNINTERRUPTED BEAD OF APPROVED SEALANT TO THE BUCKS PRIOR TO ATTACHING TO THE OPENING PER WINDOW / DOOR DETAILS. d. SEAL BUCKS WITH AN APPROVED FLASHING MATERIAL. e. INSTALL DOOR / WINDOW AND APPLY BEAD OF APPROVED SEALANT AROUND PERIMETER. 7. APPROVED CORROSION RESISTANT FLASHING SHALL BE APPLIED IN SINGLE FASHION IN A MANNER TO PREVENT ENTRY OR PENETRATION OF WATER TO THE BUILDINGS STRUCTURAL FRAMING COMPONENTS. 8. SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. 9. ALL EGRESS WINDOWS SHALL MEET FBC SECTION 1029 OR FBC-R 310, AS APPLICABLE. L_-VlgENS/ON PLAN 1 /4' 1'-0" go TV 0 FoLo 0 w N M r m W no0 J 0 M N =2Lof, as N w r N u u MNv Z U Ld [Q hK �O=X oa maw rw wL > C2 U O Of Lj L/\U JII IL/1L/LI\ CONNECTOR SCHEDULE MARK STRAP UL MAX (Ibs.) FASTENERS OA MTS 16 990 (14) 10d X 12 NAILS ABU46 Z 2405 (12) 16d X 31" NAILS TO POST AND (1)5/8" ANCHOR BOLT W/4" MIN. EMBED BEAM SCHEDULE MARK TYPE REINFORCEMENT BM-1 (3) 2X8 P.T. SYP PER BEAM PLY DETAIL COLUMN SCHEDULE MARK TYPE REINFORCEMENT C-7 (3) 2X4 P.T. SYP ABU46 Z @ BASE AND 2 MTS16 AT TOP C-2 (3) 2X6 P.T. SYP SEE 1/S2 DETAIL #10 SCREWS 0 16" O.C. MAX. & WITHIN 4" OF EDGES MINIMUM 3 SCREWS TYP. HEADER DETAIL #10 SCREWS 0 16" O.C. MAX. & WITHIN 4" OF EDGES MINIMUM 3 SCREWS I 2x P.T. BUCK TYP. JAMB DETAIL *NOTE: REFERENCE NOA INSTALLATION ANCHOR LAYOUT OR SPECIFIC ANCHOR LOCAL AT CORNERS AND MEETING RAILS. SHIMS SHALL BEz' SHORTER THAN DEPTH OF DOOR SHALL BE NON WATER -DEGRADABLE OR COMPRESSIBLE. DOOR BUCK AT FRAME DETAIL SCALE: 3/4" = V-0' @ JACK SEE FOR 16 STRAPS i EA. END EA. SIDE SIPS TOP & 2x @ 1! PER WALL, SE 2x P EXISTING 2X6 RAFTERS E S i iq A BOT., HEADER ' O.C. :;TION 2x JACK W/ 16d F (2) 2x FU LENGTH W/16dF P.T. ATE TOP OF SLAB KIST. CONT. (2) 2x TOP PL PACE JACKS @ 12" O.C. BOVE AND BELOW OPENING TTACH W/ MTS16 TO HEADER PER PLAN STUD ACE NAILS @ 12" O.C. LL KING STUD NCE NAILS @ 12" O.C. HTT4 W/ (18) 1 Od TO STUDS & (1) 5/8" 0 A.B. D&E INTO CONC MIN. 8" EMBEDMENT. TYPICAL HEADER DETAIL SCALE: 1/2" = 1'-O" (E) METAL DECK - TO REMAIN (E) STRUCTURAL SHEATHING— TO REMAIN (E) DAMAGED 2x6 INSTALL 2x6 SCAB PAST DAMAGED AREAS A MINIMUM OF 12" CONNECT W/ (4) 10d x 3" NAILS @ EA. END SCAB REPAIR DETAIL SCALE: 3/4" = 1'-0" WOOD CONSTRUCTION NOTES 1. ALL WOOD AND WOOD CONSTRUCTION SHALL COMPLY WITH THE SPECIFICATIONS AND CODES INDICATED IN THE DESIGN CRITERIA. 2. SHEATHING SHALL BE IN ACCORDANCE WITH PS 1-95 / ANSI A 199.1. ALL SHEETS BEAR APPROPRIATE GRADING STAMP OF APA AND SPAN RATING, PROVIDE 1/8" SPACE AT PANEL EDGES AND END JOINTS UNLESS OTHERWISE NOTED. 3. ALL WOOD FRAMING SHALL BE FABRICATED AND INSTALLED PER AITC AND TPI NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION. 4. LUMBER SHALL BE IDENTIFIED IN ACCORDANCE WITH NATIONAL GRADING RULES AND SHALL BEAR GRADE STAMP OF SPIB, OR OTHER ASSOCIATION RECOGNIZED BY DOC PS 20 OR EQUIVALENT. 5, ALL METAL CONNECTIONS AND FABRICATIONS SHALL COMPLY WITH AISC OR AISI SPECIFICATIONS. 6. LUMBER 2-INCH OR LESS IN NOMINAL THICKNESS AND SHEATHING SHALL NOT EXCEED 19% MOISTURE CONTENT AT TIME OF INSTALLATION. AND SHALL BE STAMPED "S-DRY", "K-D", OR "MCI 5". ALL LUMBER SHALL BE S4S. 7. ALL WOOD MEMBERS EXPOSED TO WEATHER OR IN CONTACT WITH MASONRY, CONCRETE OR SOIL SHALL BE PRESSURE TREATED, OR HAVE APPROVED SEPARATING MATERIAL. 8. ALL LUMBER SIZES NOTED AND SPECIFIED ON PLANS ARE NOMINAL SIZES UNLESS SPECIFICALLY INDICATED AS NET SIZE. 9. UNLESS NOTED OTHERWISE, THE FOLLOWING MINIMUM LUMBER GRADES SHALL BE USED: a. STRUCTURAL ROOF AND WALL FRAMING - #2 SYP. b. NON-STRUCTURAL WALL FRAMING - STUD GRADE SPF OR METAL STUDS. c. NON-STRUCTURAL FRAMING - #2 SPF. d. ROOF FRAMING MEMBERS ABOVE THE CEILING LINE - #2 SYP e. WALL SHEATHING SHALL BE 24/16 SPAN RATED STRUCTURAL SHEATHING. 10. ROOF SHEATHING SHALL BE 4-PLY CDX SHEATHING AS SPECIFIED IN ROOF SHEATHING AND ATTACHMENT DETAIL. 11. FASTENERS AND CONNECTORS USED ON UN -TREATED WOOD EXPOSED TO WEATHER SHALL BE HOT DIPPED GALVANIZED. 12. FASTENERS AND CONNECTORS (INCLUDING TRUSS PLATES, NAILS, BOLTS, ANCHORS, ETC.) USED IN CONTACT WITH TREATED WOOD SHALL BE COMPATIBLE WITH THE TREATMENT METHOD AND AS FOLLOWS: a. WOOD TREATED WITH DOT SODIUM BORATE (SEX) -MINIMUM G90 ZINC COATING. b. WOOD TREATED WITH ACQ-C OR ACQ-D (CARBONATE) OR OTHER BORATE (NON -DOT) - MINIMUM G185 INC COATING. c. FOR ALL OTHER TREATMENT - COMPLY WITH THE RECOMMENDATIONS OF THE PRESERVATIVE WOOD SUPPLIER d. STAINLESS STEEL CONNECTORS AND FASTENERS MAY BE USED FOR ALL TYPES OF TREATED WOOD 13. WOOD FASTENING SHALL BE AS SPECIFIED IN THE DRAWINGS. FASTENING NOT SPECIFICALLY IDENTIFIED ON DRAWINGS SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE. 14. CONTRACTOR SHALL PROVIDE ALL FASTENING DEVICES NECESSARY AND SUITED FOR EACH APPLICATION. FASTENINGS IN CONTACT WITH MOISTURE SHALL BE HOT -DIPPED GALVANIZED CONFORMING TO ASTM A-158-80. 15. SHEATHING NAILS OR SCREWS SHALL BE DRIVEN SO THAT THEIR HEAD OR CROWN IF FLUSH WITH THE SURFACE OF THE SHEATHING. 16. CONNECTORS FOR TRUSS TO TRUSS COMPONENTS SHALL BE AS SPECIFIED BY THE TRUSS MANUFACTURER. 17. HANGERS AND FRAMED COMPONENTS SHALL BE FURNISHED BY THE MANUFACTURER WITH NAILS FOR SPECIFIC USE AND INSTALLATION. 18. STUDS SHALL HAVE FULL BEARING ON A SOLE PLATE OR SILL NOT LESS THAN 2 INCHES IN THICKNESS HAVING A WIDTH NOT LESS THAN THAT OF THE WALL STUDS. 19. ALL PRESERVATIVE SOLE PLATES OR SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE EARTH SHALL BE OF NATURALLY DURABLE OR PRESERVATIVE -TREATED WOOD AND SHALL MEET THE FOLLOWING: a. ALL ANCHOR BOLTS SHALL HAVE 2"x2"x1/8" PLATE WASHERS UNLESS NOTED OTHERWISE. b. BOLTS SHALL BE LOCATED AT CORNERS AND JAMBS AND WITHIN 4-INCHES OF EACH END OR JOINT IN PLATE. c. PLATES LESS THAN 20 INCHES IN LENGTH SHALL HAVE ONE ANCHOR INSTALLED IN THE MIDDLE THIRD OF THE PLATE LENGTH. d. SLEEVE ANCHORS ARE NOT PERMITTED UNLESS NOTED OTHERWISE. e. ANCHORS SHALL BE MINIMUM 1/2" DIAMETER EMBEDDED 7 INCHES INTO THE CONCRETE AND SPACED NOT MORE THAN 4 FEET UNLESS NOTED OTHERWISE. 20. WOOD FRAMING MEMBERS INCLUDING SHEATHING RESTING ON AN EXTERIOR FOUNDATION CLOSER THAN 8 INCHES FROM EXPOSED EARTH SHALL BE APPROVED NATURALLY --DURABLE WOOD OR TREATED WOOD. 21. BUILT UP LUMBER (MULTIPLE MEMBERS) MUST BE FASTENED TOGETHER TO ACT AS ONE TO RESIST THE APPLIED LOAD. PROVIDE MINIMUM 2 ROWS OF 16d @ 12" O.C. 22. POSTS OR COLUMNS SUPPORTING PERMANENT STRUCTURES AND EMBEDDED IN CONCRETE THAT IS IN DIRECT CONTACT WITH THE EARTH SHALL BE OF NATURALLY DURABLE WOOD OR PRESERVATIVE -TREATED WOOD. 23. STUDS SHALL BE PLACED WITH THEIR WIDE DIMENSION PERPENDICULAR TO THE WALL. 24. NOT LESS THAN THREE STUDS SHALL BE INSTALLED AT EACH CORNER OF AN EXTERIOR WALL. 25. IN NON -BEARING WALLS AND PARTITIONS, STUDS SHALL BE SPACED NOT MORE THAN 24 INCHES ON CENTER AND ARE PERMITTED TO BE SET WITH THE LONG DIMENSION PARALLEL TO THE WALL. 26. WOOD CONNECTORS AND HOLD-DOWNS SHALL BE AS SPECIFIED IN THE DRAWINGS AND SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. ALL PRE -MANUFACTURED CONNECTORS SHALL HAVE NAILS OR SCREWS INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS, DRIVEN FULLY. 2T ROOF SHEATHING SHALL BE FASTENED AS INDICATED IN THE DRAWINGS AND FOLLOWING AMERICAN PLYWOOD ASSOCIATIONS RECOMMENDATIONS. 28. A HOLE NOT GREATER IN DIAMETER THAN 40 PERCENT OF THE STUD WIDTH MAY BE BORED IN ANY WOOD STUD. BORED HOLES NOT GREATER THAN 60 PERCENT OF THE WIDTH OF THE STUD ARE PERMITTED IN NONBEARING PARTITIONS OR IN ANY WALL WHERE EACH BORED STUD IS DOUBLED, PROVIDED NOT MORE THAN TWO SUCH SUCCESSIVE DOUBLE STUDS ARE BORED. IN NO CASE SHALL THE EDGE OF THE BORED HOLE BE NEARER THAN 518 INCH TO THE EDGE OF THE STUD. BORED HOLES SHALL NOT BE LOCATED AT THE SAME SECTION OF STUD AS A CUT OR NOTCH. 29. EVERY ROOF RAFTER, ROOF JOIST OR TRUSS SHALL BE ANCHORED TO THE BEAM OR WALL ON WHICH THEY BEAR. 2x (2) 4",1 i // L1" MIN. 2 114" MIN. J� NOTE: CONSTRUCTION ADHESIVE, APPLY IN CROSS HATCH PATTERN TO ALL MATING SURFACES NAILS TO BE 12d SCREWS TO BE #10 2x8's 2 ROWS I 2x12's 3 ROWS 1/2" CDX PLYWOOD CONT. (NAIL ON BOTH SIDES FOR MORE THAN 2 PLIES) WOOD BEAM PLY JOIN SCALE: 3/4" = 1'-O" RAFTERS 024" RJ INSULATION x4 TOP PLATE 2x4 STUDS 0 24" O.C. MAX. 2x4 F.T. BASEPLATE WI 114" x 1 lZ TAPCONS 24" O.C. MAX. EXISTING CONC. SLAB INTERIOR NON -BEARING WALL SECTION SCALE: 12" = j _ -- RAFTERS ® W O.C. OR 16-O.C. SEE FRAMING (2) RSP4 W/ (4) M X 1/Y NAILS TOP& BOTTOM TYP. —1Z GYP. CEILING BOARD R-30 INSULATION (2) 2x4 TOP PLATE FINISHES PER OWNER 2x4 STUDS ® 16" O.C. MAX. IG CONC. SLAB INTERIOR BEARING WALL SECTION O SCALE: 1/2"=1'-0" (E) ROOF TO REMAIN (E) STRUCTURAL SHEATHING TO REMAIN (E) RAFTERS TO REMAIN —� RAFTER ANCHOR PER SCHEDULE —INSULATION PER ENERGY CALCULATIONS (2) RSP4 W/ (4) 8d X 1/2" NAILS TOP& BOTTOM TYP. (E) SOFFIT 1 TO REMAIN (2) EXISTING TOP PLATE INTERIOR FINISH PER ARCH. EXTERIOR FINISH TO MATCH EXISTING 2x6 STUDS @ 24" O.C. 1/2" CDX PLYWOOD SHEATHING W/ 10d @ 6" O.C. 2x6 P.T. BASEPLATE W/ 1/2" ANCHOR BOLT TO BE INSTALLED @ 12" O.C. D&E I/F 3" MIN. INTO SLAB 6" W x 6" D CONCRETE CURB i - SLAB T MMIN ^ —(E) SLAB REMAIN F TMIN rii."' lcq at TO REMAIN (E) REPRESENTS EXISTING TYPICAL WALL SECTION SCALE: 1/2" = 1'-O" 2x8 SYP RAFTERS @ 16" O.C. PER FRAMING PLAN (2) 2x4 SYP. PLATE MTS16 STRAP PER SCHEDULE DETAIL SCALE: 3/4" = 1'-0" ---RSP4 W/ (4) 8d'S TO STU[ & (4) 8d'S TO TOP PLATE SCHEDULE 2x4 SYP STUDS @ 16" O.C. PER FRAMING PLAN (2) 2x4 SYP JAMB 1 S2