Loading...
HomeMy WebLinkAboutEnergy Efficiency Code` FORM R405-2020 FILE COPY FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method RECEIVED Project Name: SAEED MODEL- GARAGE RIGHT Builder Name: JA N 12 2022 Street: 5500 WINTER GARDEN PARKWAY Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: et, LuQia GGwnty Permltting Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Types(1822.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=5.0 1662.00 ft2 b. Frame - Wood, Adjacent R=11.0 160.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 11. Ceiling Types (2262.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2262.00 ft2 6. Conditioned floor area above grade (ft2) 2262 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. A R= ft2 7. Windows(257.3 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: AHU CLST R ft2 6 200 a. U-Factor: Sgl, U=0.65 257.33 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 46.5 SEER:16.00 c. U-Factor: N/A ft2 SHGC: ft Area Weighted Average Overhang Depth: 3.528 . 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.250 a. Electric Strip Heat 34.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (2262.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2262.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits None Glass/Floor Area: 0.114 Total Proposed Modified Loads: 59.63 PASS Total Baseline Loads: 67.36 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this C1 .^.._. Code. calculation indicates compliance �� �ii, s''0 with the Florida Energy Code. r."'�% PREPARED BY: Before construction is completed DATE: - - this building will be inspected for compliance with Section 553.908� I herebycertify that this building, as designed, is in compliance fY 9 9 Florida Statutes. �S with the Florida Energy Code. OWNER/AGE- BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). REVIEWED FOR CODE COMPLIANCE �UCCIE COUNTY BOCC 11/16/2021 12:01 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition ( omp cant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: SAEED MODEL- GARAGE RI Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2262 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 5500 WINTER GARDE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/E)asting: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2262 19978 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 4 175 1400 No 0 1 1 Yes Yes Yes 2 BATH 3 50 400 No 0 1 Yes Yes Yes 3 BEDROOM 3 160 1280 No 0 1 1 Yes Yes Yes 4 CLST 3 20 160 No 0 1 Yes Yes Yes 5 BATH 2 50 400 No 0 1 Yes Yes Yes 6 BEDROOM 2 205 1640 No 0 1 1 Yes Yes Yes 7 CLST 2 20 160 No 0 1 Yes Yes Yes 8 HALL3 25 200 No 0 1 No Yes Yes 9 HALL 2 25 200 No 0 1 No Yes Yes 10 LIVING RM 380 3800 No 0 1 Yes Yes Yes 11 GREAT RM 353 3530 No 0 1 Yes Yes Yes 12 M BATH 128 1024 No 0 1 Yes Yes Yes 13 M WIC 84 672 No 0 1 Yes Yes Yes 14 MASTER BEDROO 259 2072 No 0 1 1 Yes Yes Yes 15 KITCHEN 208 2080 Yes 0 1 Yes Yes Yes 16 UTILITY RM 40 320 No 0 1 Yes Yes Yes 17 AHU CLST 15 120 No 0 1 No Yes Yes 18 PANTRY 45 360 No 0 1 Yes Yes Yes 19 CLST 4 20 160 No 0 1 Yes Yes Yes 11/16/2021 12:01 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 4 31 ft 175 ft2 _-_- 1 0 0 2 Slab -On -Grade Edge Insulation BATH 3 5 ft 50 ft2 ____ 1 0 0 3 Slab -On -Grade Edge Insulation BEDROOM 3 10 ft 160 ft2 ____ 1 0 0 4 Slab -On -Grade Edge Insulation CLST 3 2 ft 20 ft2 i -__- 1 0 0 5 Slab -On -Grade Edge Insulation BATH 2 5 ft 50 ft2 ____ 1 0 0 6SIab-On-Grade Edge Insulation BEDROOM 2 34 ft 205 ft2 ____ 1 0 0 7 Slab -On -Grade Edge Insulation CLST 2 2 ft 20 ft2 ____ 1 0 0 8 Slab -On -Grade Edge Insulation HALL3 1 ft 25 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulation HALL 2 1 ft 25 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulation LIVING RM 19 ft 380 ft2 -___ 1 0 0 11SIab-On-Grade Edge Insulation GREAT RM 15 ft 353 ft2 ___- 1 0 0 12SIab-On-Grade Edge Insulation M BATH 29 ft 128 ft2 _-__ 1 0 0 13SIab-On-Grade Edge Insulation M W IC 7 ft 84 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation MASTER BEDRO 14 ft 259 ft2 -_-_ 1 0 0 15SIab-On-Grade Edge Insulation KITCHEN 13 ft 208 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulation UTILITY RM 3 ft 40 ft2 ____ 1 0 0 17SIab-On-Grade Edge Insulation AHU CLST 1 ft 15 ft2 -___ 1 0 0 18SIab-On-Grade Edge Insulation PANTRY 5 ft 45 ft2 ____ 1 0 0 19SIab-On-Grade Edge Insulation CLST 4 2 ft 20 ft2 _--_ 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2451 ft2 0 ft2 Light N 0.3 No 0.9 No 0 22.62 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2262 ft2 N N 11/16/2021 12:01 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 175ft2 0.1 Wood 2 Under Attic (Vented) BATH 3 30 Blown 50ft2 0.1 Wood 3 Under Attic (Vented) BEDROOM 3 30 Blown 160 ft2 0.1 Wood 4 Under Attic (Vented) CLST 3 30 Blown 20 ft2 0.1 Wood 5 Under Attic (Vented) BATH 2 30 Blown 50 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 205 ft2 0.1 Wood 7 Under Attic (Vented) CLST 2 30 Blown 20 ft2 0.1 Wood 8 Under Attic (Vented) HALL3 30 Blown 25 ft2 0.1 Wood 9 Under Attic (Vented) HALL 2 30 Blown 25 ft2 0.1 Wood 10 Under Attic (Vented) LIVING RM 30 Blown 380 ft2 0.1 Wood 11 Under Attic (Vented) GREAT RM 30 Blown 353 ft2 0.1 Wood 12 Under Attic (Vented) M BATH 30 Blown 128 ft2 0.1 Wood 13 Under Attic (Vented) M WIC 30 Blown 84 ft2 0.1 Wood 14 Under Attic (Vented) MASTER BEDRO 30 Blown 259 ft2 0.1 Wood 15 Under Attic (Vented) KITCHEN 30 Blown 208 ft2 0.1 Wood 16 Under Attic (Vented) UTILITY RM 30 Blown 40 ft2 0.1 Wood 17 Under Attic (Vented) AHU CLST 30 Blown 15 ft2 0.1 Wood 18 Under Attic (Vented) PANTRY 30 Blown 45 ft2 0.1 Wood 19 Under Attic (Vented) CLST 4 30 Blown 20 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below ()rnt Space Tn Wall Type 1 E Exterior Concrete Block - Int InsuBEDROOM 4 5 15 0 8 0 120.0 ft2 0 0 0.3 0 2 S Exterior Concrete Block - Int InsuBEDROOM 4 5 5 0 8 0 40.0 ft2 0 0 0.3 0 3 N Exterior Concrete Block - Int InsuBEDROOM 4 5 11 0 8 0 88.0 ft2 0 0 0.3 0 4 N Exterior Concrete Block - Int Insul BATH 3 5 5 0 8 0 40.0 ft2 0 0 0.3 0 5 N Exterior Concrete Block - Int InsuBEDROOM 3 5 10 0 8 0 80.0 ft2 0 0 0.3 0 6 N Exterior Concrete Block - Int Insul CLST 3 5 2 0 8 0 16.0 ft2 0 0 0.3 0 7 N Exterior Concrete Block - Int Insul BATH 2 5 5 0 8 0 40.0 ft2 0 0 0.3 0 8 S Exterior Concrete Block - Int InsuBEDROOM 2 5 6 0 8 0 48.0'ft2 0 0 0.3 0 9 W Exterior Concrete Block - Int InsuBEDROOM 2 5 15 0 8 0 120.0 ft2 0 0 0.3 0 10 N Exterior Concrete Block - Int InsuBEDROOM 2 5 13 0 8 0 104.0 ft2 0 0 0.3 0 11 N Exterior Concrete Block - Int Insul CLST 2 5 2 0 8 0 16.0 ft2 0 0 0.3 0 12 E Exterior Concrete Block - Int Insul LIVING RM 5 19 0 10 0 190.0 ft2 0 0 0.3 0 13 W Exterior Concrete Block - Int InsuIGREAT RM 5 15 0 10 0 150.0 ft2 0 0 0.3 0 14 E Exterior Concrete Block - Int Insul M BATH 5 16 0 8 0 128.0 ft2 0 0 0.3 0 15 S Exterior Concrete Block - Int Insul M BATH 5 8 0 8 0 64.0 ft2 0 0 0.3 0 16 N Exterior Concrete Block - Int Insul M BATH 5 5 0 8 0 40.0 ft2 0 0 0.3 0 17 N Exterior Concrete Block- Int Insul M W IC 5 7 0 8 0 56.0 ft2 0 0 0.3 0 18 S Exterior Concrete Block - Int InsuMASTER BE 5 14 0 8 0 112.0 ft2 0 0 0.3 0 19 S Exterior Concrete Block - Int Insul KITCHEN 5 13 0 10 0 130.0 ft2 0 0 0.3 0 20 N Exterior Concrete Block - Int InsulUTILITY RM 5 3 0 8 0 24.0 ft2 0 0 0.3 0 21 W Garage Frame - Wood UTILITY RM 11 8 0 8 0 64.0 ft2 0 0.1 0.3 0 11/16/2021 12:01 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w 22 W Garage Frame - Wood AHU CLST 11 3 0 8 0 24.0 ft2 0 0.1 0.3 0 23 S Exterior Concrete Block - Int Insul PANTRY 5 5 0 8 0 40.0 ft2 0 0 0.3 0 24 W Garage Frame - Wood PANTRY 11 9 0 8 0 72.0 ft2 0 0.1 0.3 0 25 N Exterior Concrete Block - Int lnsul CLST 4 5 2 0 8 0 16.0 ft2 0 0 0.3 0 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 1 ft 0 in 1 ft4 in None None 2 N 3 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 1 ft0 in 1 ft4 in None None 3 N 5 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 1 ft 0 in 1 ft 4 in None None 4 N 7 Metal Low-E Single Yes 0.65 0.25 N 3.0 ft2 1 ft0 in 1 ft 4 in None None 5 W 9 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 1 ft 0 in 1 ft4 in None None 6 N 10 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 1 ft0 in 1 ft 4 in None None 7 E 12 Metal Low-E Single Yes 0.65 0.25 N 53.3 ft2 6 ft 0 in 1 ft 4 in None None 8 W 13 Metal Low-E Single Yes 0.65 0.25 N 48.0 ft2 9 ft 0 in 1 ft 4 in None None 9 E 14 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 1 ft 0 in 1 ft4 in None None 10 S 18 Metal Low-E Single Yes 0.65 0.25 N 40.0 ft2 1 ft 0 in 1 ft4 in None None 11 S 19 Metal Low-E Single Yes 0.65 0.25 N 3.0 ft2 1 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 400 ft2 400 ft2 20 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .00028 1664.8 91.34 171.48 .0939 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity - Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 46.5 kBtu/hr 1395 cfm 0.8 1 sys#1 11/16/2021 12:01 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location' EF Cap Use SetPnt Conservation 1 Electric None AHU CLST 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS . / --- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 200 ft2 Attic 20 ft2 Default Leakage AHU CLST (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb HeatinHJan HFeb Mar Mar 1XI [ ] Apr [ ] Apr Ma May [[X] Jun [X] Jul j ]Jun j ]Jul [X] AugX] [) Auj Se ] Sep [ ] Oct Nov [ ] Oct Nov Dec Dec Ventin Jan Feb Mar [X] Apr [ May l [[ ] Jun [ ] Jul [ ] Aug [ ] Se [X] Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft, ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8lbs/sq.ft. ft2 ft 0.3 FOYER/GREAT RM Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 ' Default(8 Ibs/s .ft. ft2 ft 0.3 HALL 11/16/2021 12:01 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6 2026 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: SAEED MODEL- GARAGE RIGHT Builder Name: Street: 5500 WINTER GARDEN PARKWAY Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y U Owner: Jurisdiction: ST LUCIE COUNTY w Design Location: FL, Fort Pierce U , COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Piping and wirin . Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilin s. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 11/16/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 89 The lower the EnergyPerformance Index, the more efficient the home. 5500 WINTER GARDEN PARKWAY, FORT PIERCE, FL, 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows- Description a. U-Factor: Sgl, U=0.65 SHGC: SHGC=0.25 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A New (From Plans) Detached 1 4 No 2262 Area 257.33 ft2 ft2 ft2 ft2 3.528 ft. 0.250 Area ft2 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 2262.00 ftz b. N/A R= ft2 c. N/A R= ft2 10. Wall Type and Insulation a. Concrete Block - Int Insul, Exterior b. Frame- Wood, Adjacent c. N/A d. N/A 11. Ceiling Type and insulation level a. Under Attic (Vented) b. N/A c. N/A 12. Ducts, location & insulation level a. Sup: Attic, Ret: Attic, AH: AHU CLST 13. Cooling systems a. Central Unit 14. Heating systems a. Electric Strip Heat 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida.Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Insulation R=5.0 R=11.0 R= R= Insulation R=30.0 R= R= Area 1662.00 ft2 160.00 ft2 ft2 ft2 Area 2262.00 ft2 ft2 ft2 R ft2 6 200 kBtu/hr Efficiency 46.5 SEER:16.00 kBtu/hr Efficiency 34.0 COP:1.00 Cap: 50 gallons EF: 0.98 None *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 11/16/2021 12:01 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1