HomeMy WebLinkAboutEnergy Efficiency Code` FORM R405-2020 FILE COPY
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
RECEIVED
Project Name: SAEED MODEL- GARAGE RIGHT
Builder Name:
JA N 12 2022
Street: 5500 WINTER GARDEN PARKWAY
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
et, LuQia GGwnty
Permltting
Owner:
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Types(1822.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=5.0 1662.00 ft2
b. Frame - Wood, Adjacent
R=11.0 160.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
11. Ceiling Types (2262.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 2262.00 ft2
6. Conditioned floor area above grade (ft2) 2262
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. A
R= ft2
7. Windows(257.3 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: AHU CLST
R ft2
6 200
a. U-Factor: Sgl, U=0.65 257.33 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
46.5 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
ft Area Weighted Average Overhang Depth: 3.528 .
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.250
a. Electric Strip Heat
34.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (2262.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 2262.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
None
Glass/Floor Area: 0.114 Total Proposed Modified Loads: 59.63
PASS
Total Baseline Loads: 67.36
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
C1 .^.._.
Code.
calculation indicates compliance
�� �ii, s''0
with the Florida Energy Code.
r."'�%
PREPARED BY:
Before construction is completed
DATE: - -
this building will be inspected for
compliance with Section 553.908�
I herebycertify that this building, as designed, is in compliance
fY 9 9
Florida Statutes.
�S
with the Florida Energy Code.
OWNER/AGE-
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
REVIEWED FOR
CODE COMPLIANCE
�UCCIE COUNTY BOCC
11/16/2021 12:01 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition ( omp cant Software Page 1 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
SAEED MODEL- GARAGE RI
Bedrooms:
4
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2262
Lot #
Owner Name:
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
Rotate Angle:
0
Street:
5500 WINTER GARDE
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Detached
FL,
New/E)asting:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
v Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2262
19978
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
BEDROOM 4
175
1400 No
0
1
1
Yes
Yes
Yes
2
BATH 3
50
400 No
0
1
Yes
Yes
Yes
3
BEDROOM 3
160
1280 No
0
1
1
Yes
Yes
Yes
4
CLST 3
20
160 No
0
1
Yes
Yes
Yes
5
BATH 2
50
400 No
0
1
Yes
Yes
Yes
6
BEDROOM 2
205
1640 No
0
1
1
Yes
Yes
Yes
7
CLST 2
20
160 No
0
1
Yes
Yes
Yes
8
HALL3
25
200 No
0
1
No
Yes
Yes
9
HALL 2
25
200 No
0
1
No
Yes
Yes
10
LIVING RM
380
3800 No
0
1
Yes
Yes
Yes
11
GREAT RM
353
3530 No
0
1
Yes
Yes
Yes
12
M BATH
128
1024 No
0
1
Yes
Yes
Yes
13
M WIC
84
672 No
0
1
Yes
Yes
Yes
14
MASTER BEDROO
259
2072 No
0
1
1
Yes
Yes
Yes
15
KITCHEN
208
2080 Yes
0
1
Yes
Yes
Yes
16
UTILITY RM
40
320 No
0
1
Yes
Yes
Yes
17
AHU CLST
15
120 No
0
1
No
Yes
Yes
18
PANTRY
45
360 No
0
1
Yes
Yes
Yes
19
CLST 4
20
160 No
0
1
Yes
Yes
Yes
11/16/2021 12:01 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulation
BEDROOM 4
31 ft
175 ft2
_-_-
1
0
0
2 Slab -On -Grade Edge Insulation
BATH 3
5 ft
50 ft2
____
1
0
0
3 Slab -On -Grade Edge Insulation
BEDROOM 3
10 ft
160 ft2
____
1
0
0
4 Slab -On -Grade Edge Insulation
CLST 3
2 ft
20 ft2
i
-__-
1
0
0
5 Slab -On -Grade Edge Insulation
BATH 2
5 ft
50 ft2
____
1
0
0
6SIab-On-Grade Edge Insulation
BEDROOM 2
34 ft
205 ft2
____
1
0
0
7 Slab -On -Grade Edge Insulation
CLST 2
2 ft
20 ft2
____
1
0
0
8 Slab -On -Grade Edge Insulation
HALL3
1 ft
25 ft2
____
1
0
0
9 Slab -On -Grade Edge Insulation
HALL 2
1 ft
25 ft2
____
1
0
0
10SIab-On-Grade Edge Insulation
LIVING RM
19 ft
380 ft2
-___
1
0
0
11SIab-On-Grade Edge Insulation
GREAT RM
15 ft
353 ft2
___-
1
0
0
12SIab-On-Grade Edge Insulation
M BATH
29 ft
128 ft2
_-__
1
0
0
13SIab-On-Grade Edge Insulation
M W IC
7 ft
84 ft2
____
1
0
0
14SIab-On-Grade Edge Insulation
MASTER BEDRO 14 ft
259 ft2
-_-_
1
0
0
15SIab-On-Grade Edge Insulation
KITCHEN
13 ft
208 ft2
____
1
0
0
16SIab-On-Grade Edge Insulation
UTILITY RM
3 ft
40 ft2
____
1
0
0
17SIab-On-Grade Edge Insulation
AHU CLST
1 ft
15 ft2
-___
1
0
0
18SIab-On-Grade Edge Insulation
PANTRY
5 ft
45 ft2
____
1
0
0
19SIab-On-Grade Edge Insulation
CLST 4
2 ft
20 ft2
_--_
1
0
0
ROOF
Roof
Gable Roof
Rad
Solar SA Emitt
Emitt
Deck
Pitch
V # Type Materials
Area
Area Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip
Metal 2451 ft2
0 ft2 Light
N
0.3 No 0.9
No
0
22.62
ATTIC
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Vented
150
2262 ft2
N N
11/16/2021 12:01 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) BEDROOM
30
Blown
175ft2
0.1
Wood
2
Under Attic (Vented) BATH 3
30
Blown
50ft2
0.1
Wood
3
Under Attic (Vented) BEDROOM 3
30
Blown
160 ft2
0.1
Wood
4
Under Attic (Vented) CLST 3
30
Blown
20 ft2
0.1
Wood
5
Under Attic (Vented) BATH 2
30
Blown
50 ft2
0.1
Wood
6
Under Attic (Vented) BEDROOM 2
30
Blown
205 ft2
0.1
Wood
7
Under Attic (Vented) CLST 2
30
Blown
20 ft2
0.1
Wood
8
Under Attic (Vented) HALL3
30
Blown
25 ft2
0.1
Wood
9
Under Attic (Vented) HALL 2
30
Blown
25 ft2
0.1
Wood
10
Under Attic (Vented) LIVING RM
30
Blown
380 ft2
0.1
Wood
11
Under Attic (Vented) GREAT RM
30
Blown
353 ft2
0.1
Wood
12
Under Attic (Vented) M BATH
30
Blown
128 ft2
0.1
Wood
13
Under Attic (Vented) M WIC
30
Blown
84 ft2
0.1
Wood
14
Under Attic (Vented) MASTER BEDRO 30
Blown
259 ft2
0.1
Wood
15
Under Attic (Vented) KITCHEN
30
Blown
208 ft2
0.1
Wood
16
Under Attic (Vented) UTILITY RM
30
Blown
40 ft2
0.1
Wood
17
Under Attic (Vented) AHU CLST
30
Blown
15 ft2
0.1
Wood
18
Under Attic (Vented) PANTRY
30
Blown
45 ft2
0.1
Wood
19
Under Attic (Vented) CLST 4
30
Blown
20 ft2
0.1
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
()rnt
Space
Tn Wall Type
1
E
Exterior Concrete Block - Int InsuBEDROOM 4
5
15
0 8
0
120.0 ft2
0
0
0.3
0
2
S
Exterior Concrete Block - Int InsuBEDROOM 4
5
5
0 8
0
40.0 ft2
0
0
0.3
0
3
N
Exterior Concrete Block - Int InsuBEDROOM 4
5
11
0 8
0
88.0 ft2
0
0
0.3
0
4
N
Exterior Concrete Block - Int Insul BATH 3
5
5
0 8
0
40.0 ft2
0
0
0.3
0
5
N
Exterior Concrete Block - Int InsuBEDROOM 3
5
10
0 8
0
80.0 ft2
0
0
0.3
0
6
N
Exterior Concrete Block - Int Insul CLST 3
5
2
0 8
0
16.0 ft2
0
0
0.3
0
7
N
Exterior Concrete Block - Int Insul BATH 2
5
5
0 8
0
40.0 ft2
0
0
0.3
0
8
S
Exterior Concrete Block - Int InsuBEDROOM 2
5
6
0 8
0
48.0'ft2
0
0
0.3
0
9
W
Exterior Concrete Block - Int InsuBEDROOM 2
5
15
0 8
0
120.0 ft2
0
0
0.3
0
10
N
Exterior Concrete Block - Int InsuBEDROOM 2
5
13
0 8
0
104.0 ft2
0
0
0.3
0
11
N
Exterior Concrete Block - Int Insul CLST 2
5
2
0 8
0
16.0 ft2
0
0
0.3
0
12
E
Exterior Concrete Block - Int Insul LIVING RM
5
19
0 10
0
190.0 ft2
0
0
0.3
0
13
W
Exterior Concrete Block - Int InsuIGREAT RM
5
15
0 10
0
150.0 ft2
0
0
0.3
0
14
E
Exterior Concrete Block - Int Insul M BATH
5
16
0 8
0
128.0 ft2
0
0
0.3
0
15
S
Exterior Concrete Block - Int Insul M BATH
5
8
0 8
0
64.0 ft2
0
0
0.3
0
16
N
Exterior Concrete Block - Int Insul M BATH
5
5
0 8
0
40.0 ft2
0
0
0.3
0
17
N
Exterior Concrete Block- Int Insul M W IC
5
7
0 8
0
56.0 ft2
0
0
0.3
0
18
S
Exterior Concrete Block - Int InsuMASTER BE
5
14
0 8
0
112.0 ft2
0
0
0.3
0
19
S
Exterior Concrete Block - Int Insul KITCHEN
5
13
0 10
0
130.0 ft2
0
0
0.3
0
20
N
Exterior Concrete Block - Int InsulUTILITY RM
5
3
0 8
0
24.0 ft2
0
0
0.3
0
21
W
Garage Frame - Wood UTILITY RM
11
8
0 8
0
64.0 ft2
0
0.1
0.3
0
11/16/2021 12:01 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing Solar
Belo w
22 W
Garage Frame - Wood
AHU CLST 11 3 0 8
0
24.0 ft2
0
0.1 0.3
0
23 S
Exterior Concrete Block - Int
Insul PANTRY 5 5 0 8
0
40.0 ft2
0
0 0.3
0
24 W
Garage Frame - Wood
PANTRY 11 9 0 8
0
72.0 ft2
0
0.1 0.3
0
25 N
Exterior Concrete Block - Int lnsul CLST 4 5 2 0 8
0
16.0 ft2
0
0 0.3
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V #
Ornt ID Frame Panes
NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
E 1 Metal Low-E Single
Yes
0.65 0.25 N
20.0 ft2
1 ft 0 in
1 ft4 in
None
None
2
N 3 Metal Low-E Single
Yes
0.65 0.25 N
20.0 ft2
1 ft0 in
1 ft4 in
None
None
3
N 5 Metal Low-E Single
Yes
0.65 0.25 N
20.0 ft2
1 ft 0 in
1 ft 4 in
None
None
4
N 7 Metal Low-E Single
Yes
0.65 0.25 N
3.0 ft2
1 ft0 in
1 ft 4 in
None
None
5
W 9 Metal Low-E Single
Yes
0.65 0.25 N
20.0 ft2
1 ft 0 in
1 ft4 in
None
None
6
N 10 Metal Low-E Single
Yes
0.65 0.25 N
15.0 ft2
1 ft0 in
1 ft 4 in
None
None
7
E 12 Metal Low-E Single
Yes
0.65 0.25 N
53.3 ft2
6 ft 0 in
1 ft 4 in
None
None
8
W 13 Metal Low-E Single
Yes
0.65 0.25 N
48.0 ft2
9 ft 0 in
1 ft 4 in
None
None
9
E 14 Metal Low-E Single
Yes
0.65 0.25 N
15.0 ft2
1 ft 0 in
1 ft4 in
None
None
10
S 18 Metal Low-E Single
Yes
0.65 0.25 N
40.0 ft2
1 ft 0 in
1 ft4 in
None
None
11
S 19 Metal Low-E Single
Yes
0.65 0.25 N
3.0 ft2
1 ft 0 in
1 ft 4 in
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
400 ft2 400 ft2
20 ft
8 ft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse ProposedACH(50)
.00028
1664.8 91.34 171.48
.0939
5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COPA
34 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency
Capacity - Air Flow
SHR Block
Ducts
1
Central Unit/
Split
Single SEER: 16
46.5 kBtu/hr 1395 cfm
0.8 1
sys#1
11/16/2021 12:01 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location'
EF
Cap
Use
SetPnt
Conservation
1 Electric
None
AHU CLST 0.98
50 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS .
/ --- Supply ----
---- Return ----
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 200 ft2
Attic
20 ft2
Default Leakage
AHU CLST
(Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
CoolingJan Feb
HeatinHJan HFeb
Mar
Mar
1XI
[ ] Apr
[ ] Apr
Ma
May
[[X] Jun [X] Jul
j ]Jun j ]Jul
[X] AugX]
[) Auj
Se
] Sep
[ ] Oct Nov
[ ] Oct Nov
Dec
Dec
Ventin Jan Feb
Mar
[X] Apr
[ May
l
[[ ] Jun [ ] Jul
[ ] Aug
[ ] Se
[X] Oct [X] Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4
5 6
7
8
9 10 11
12
Cooling (WD) AM
78
78 78
78
78 78
78
78
80 80 80
80
PM
80
80 80
80
78 78
78
78
78 78 78
78
Cooling (WEH) AM
78
78 78
78
78 78
78
78
80 80 80
80
PM
80
80 80
80
78 78
78
78
78 78 78
78
Heating (W D) AM
65
65 65
65
65 65
65
68
68 68 68
68
PM
68
68 68
68
68 68
68
68
68 68 68
68
Heating (WEH) AM
65
65 65
65
65 65
65
68
68 68 68
68
PM
68
68 68
68
68 68
68
68
68 68 68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M TOILET
Default(8 Ibs/sq.ft.
ft,
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8lbs/sq.ft.
ft2
ft
0.3
FOYER/GREAT RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3 '
Default(8 Ibs/s .ft.
ft2
ft
0.3
HALL
11/16/2021 12:01 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6
2026 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: SAEED MODEL- GARAGE RIGHT Builder Name:
Street: 5500 WINTER GARDEN PARKWAY Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Y
U
Owner: Jurisdiction: ST LUCIE COUNTY
w
Design Location: FL, Fort Pierce
U ,
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring an
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind Piping and wirin .
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building thermal
envelope shall be sealed to the sub -floor, wall covering or ceiling
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilin s.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
11/16/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 89
The lower the EnergyPerformance Index, the more efficient the home.
5500 WINTER GARDEN PARKWAY, FORT PIERCE, FL,
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows-
Description
a. U-Factor:
Sgl, U=0.65
SHGC:
SHGC=0.25
b. U-Factor:
N/A
SHGC:
c. U-Factor:
N/A
SHGC:
d. U-Factor:
N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights
Description
a. U-Factor(AVG):
N/A
SHGC(AVG):
N/A
New (From Plans)
Detached
1
4
No
2262
Area
257.33 ft2
ft2
ft2
ft2
3.528 ft.
0.250
Area
ft2
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 2262.00 ftz
b. N/A R= ft2
c. N/A R= ft2
10. Wall Type and Insulation
a. Concrete Block - Int Insul, Exterior
b. Frame- Wood, Adjacent
c. N/A
d. N/A
11. Ceiling Type and insulation level
a. Under Attic (Vented)
b. N/A
c. N/A
12. Ducts, location & insulation level
a. Sup: Attic, Ret: Attic, AH: AHU CLST
13. Cooling systems
a. Central Unit
14. Heating systems
a. Electric Strip Heat
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida.Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
Insulation
R=5.0
R=11.0
R=
R=
Insulation
R=30.0
R=
R=
Area
1662.00 ft2
160.00 ft2
ft2
ft2
Area
2262.00 ft2
ft2
ft2
R ft2
6 200
kBtu/hr Efficiency
46.5 SEER:16.00
kBtu/hr Efficiency
34.0 COP:1.00
Cap: 50 gallons
EF: 0.98
None
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
11/16/2021 12:01 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1