Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval Swinging Exterior Doors
BCIS Home 1 Log In l User Registration ( Hot Topics ; Submit Surcharge Stats & Facts Florida II Product Approval 'l1 �. -Q. r„�. +�i� LL,USER:Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL14850-R4 Application Type Revision Code Version 2020 Application Status Approved Comments Archived X RECEIVED JAN 12 2022 St. Lucie County Permitting BCIS Site Map ( Links I Search ( Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue ' Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Authorized Signature ]ay Lathrop jlathrop@cws.cc Technical Representative ]ay Lathrop Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Quality Assurance Representative Cal Ledy Address/Phone/Email 1900.SW 44th Ave. Ocala, FL 34474 (352)368-6922 cledy@cws.cc Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Lucas Turner Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 07/21/2028 Validated By Steven M. Urich, PE 0- Validation Checklist - Hardcopy Received Certificate of Independence FL14850 R4 COI EvalRegort641D.pdf Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Standard AAMA/WDMA/CSA 101/I.S.2/A-440 ASTM E1886-13a ASTM E1996-17 PA TAS/201/202/203 Florida Licensed Professional Engineer or Architect Year 2008 2013 2017 1994 FL14850 R4 Equiv 87XX LM Equivalency_pdf r' Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/10/2020 Date Validated 08/10/2020 Date Pending FBC Approval 08/19/2020 Date Approved 10/13/2020 Mumma :.of Products' Model, Numberor-Name Desc[iptton' 'p} 14850.1 FD-8750, Imiact. FD-8750 French Door, SD-8700 Swing Door, SLT-8710 Sidelite, Impact. Limits of Use Installation Instructions Approved for use in HVHZ. Yes FL14850 R4 II CWS-641D,pdf Approved for use outside HVHZ: Yes' Verified By: Lucas Turner 58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: +70/-70 Evaluation Reports Other: Large Missile French Door w/ Sidelights, Max. French FL14850 R4 AE EvalReport641D,pdf I Door 6' x 8', Max. Single Door 3' x 8', Ma;x. Sidelight 3' x 8', DP Created by Independent Third Party: Yes +/- 70 psf. Glass complies to ASTM E1300. I Contact Us'r: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. COp�Lriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records.lIf you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which ca be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Credit Card;: SWING DOOR & SIDELITE - LARGE MISSILE IMPACT 79" MAX. FRENCH DOOR WIDTH 37 5/8" MAX. PANEL WIDTH 26 5/8" GLASS DLO I - 17" r AAX. JNIT HEIGHT l+l C 95 3/16" MAX. X PANEL HEIGHT 84 3/16" GLASS [NJOTE4 DLO 11 FRENCF` DOOR TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS 1-3 GLAZING DETAILS...................................4 SECTION VIEWS .................................... .7 BOM............................................................8 EXTRUSIONS.............................................9 ANCHOR SCHEDULE & NOTES ............. 10 INSTALLATION DETAILS....................11 •12 36 3/16" MAX. SIDELITE W IDTH 33 5/8" MAX. — PANEL WIDTH 22 518" — GLASS DLO D —I— 97" MAX. UNIT E E HEIG C+ D 94 5/8" FLUSH BOLT ON I 12 INACTIVE PANEL I PANEL HEIGHT 3B 11 83 5/8" GO LA I 1 40' MAX. SINGLE 1 DOOR WIDTH D C 37 5/8" MAX. 12 PANEL WIDTH SIDELITE 26 5/8" A GLASS DLO 8 1/2' NOTE:. HINGE SPACINGS ARE 8-1/2" 97" FROM ENDS AND 20" MAX. O.C. MAX- 20" FOR 81" TO 97" UNIT HEIGHT. UNIT HEIGHT 95 3/16" — — MAX. x I B PANEL B HEIGHT 84 3/16" GLA GLOSS SEE NOTE4� 8 1/2" SINGLE DOOR GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING C DE (FBC), CUR ENT EDITION INCLUDING THE HIGH VELOCITY NUI RICANE ZONE (IIVHZ) AND IS RATED FOR WIND ZONE 4 MISSILE LEVEL pp IMPACT USE AS DEFINED IN ASTM E 1996 PER THE FBC. 2. GLAZING OPTIONS: (SEE SHEET 4) 3. CONFIGURATIONS: SINGLE OUTSWING, SINGLE OUTSWING w/SIDELITE(S), FRENCH DOOR(S), FRENCH DOOR(S) w/SIDELITE(S), SIDELITE NOT ATTACHED. . 4. LOCK OPTIONS: UP TO 618": A. DOUBLE BORE w/TWO (2) INTERIOR FLUSH BOLTS. HANDLE SET @ 36" B. MORTISE LOCK w/TWO (2) INTERIOR PLUSH BOLTS. HANDLE SET @ 34" C. MULTIPOINT (4 PT.) HANDLE SET @ 34' ABOVE 6'8": A. MULTIPOINT (5 PT.) HANDLE SET @ 34' 5. DESIGN PRESSURE RATING: -NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. -POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. 6. ANCHORAGE: THE 33 1/3 % STRESS INCr :p SE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. SEE SHEETS 11-12 FOR ANCHOR DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 7. PRODUCTS APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT REQUIRED. 8. ALL FRAMES ARE PROCESSED APHID SCF WED TOGETHER. PANELS ARE PROCESSED AND ASSEMBLED VIA i rr ROD. 9. SERIES / MODEL DESIGNATIO1 4 SD-8700, FID-8750, SLT-8710. 10. THE DESIGNATION X AND 0 STAND FOR THE FOLLOWING: X = OPERABLE SASH, 0 = FIXED SASH 11. SECTION CALLOUTS APPLY TO ALL CONFIGURATIONS IN A SIMILAR LOCATION. 12. INTERIOR FLUSH BOLTS ON ACTIVE PANEL Tq BE ENGAGED PRIOR TO SEVERE WEATHER. 13. QUALIFIED ALTERNATIVE LOCKSET/DEADBOLT HARDWARE IS GRADE 2 BY PAMEX AND DELANY. 14. MAX. PANEL WIDTHS APPLY TO ALL CONFIGURATIONS, MULLED OR NON -MULLED UNITS. TYPE MAX. PANEL SIZE DESIGN PRESSURE RATING IMPACT RATING SINGLE 37-5/8" x 95-3/16" +/- 70 PSF LARGE MISSILE IMPACT FRENCH SIDELITE 33-5/8" x 94-5/8" nobs wo' WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 8700/10/50 PVC SWING DOOR IMPACT a Z 3 ¢Z� ow O ¢wFF0p Z Z0Z D:rK� o ¢ U�} O W3�. m U_ Fw ZF�:2x Z ZM2<ww00 0 OI—O ¢=F.0� U 0Cn ZD-Frna. Z p � Z�U- ¢ ZOCOZOti0 <�OWOFOZ U WLL caOW(nW ZEW 0-1U) w =FIL' wEL �w� D. F- D w a- /.�G No. 58201 \ �% STATE OF '2 RO- 08/06/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 GENERAL NOTES AND ELEVATIONS Lucas Turner DRAWN BY: DATE: 2020.08.10 ADE 09/08/11 12:04:58 DWG #: REV.: -05,00, CWS-641 D SCALE: SHEET 1:35 1 OF 12 151 3/8" MAX UNIT WIDTH 36 3/16' MAX - 79" SIDELITE WIDTH MAX FRENCH DOOR WIDTH 3351. 37 5/8' MAX �{ PANEL WIDTH PANEL WIDTHI 37" o1AX. JNIT 1EGHT SIDELITE Q )( X O PANI HEIGHT HEIC FLUSH BOLT 83 5/8" ON 84 3/16" SIDELITE SEE INACTIVE DOOR GLASS NOTE 4 PANEL GLASS DLO SHT1 4-1 DLO H2�'58" 26 5/8" GLASS DLO GLASS ULU FRENCH DOOR w/SIDELITES —115 3/16" MAX UNIT WIDTH 36 3116" MAX 79" SIDELITE WIDTH MAX FRENCH DOOR WIDTH 33 5/8" MAX --37-5/8' W J_ PANEL WIDTH DOORWI[ -- i7" I JfAX. JNIT 1EGHT 94 SIDELITE 5/8" Q X X 95 3/ HEIGHT PANE 83 5/8" FLUSH BOLT HEIG SIDELITE ON 84 3/16" GLASS SEE INACTIVE DOOR DLO NOTE PANEL GLASS SHT 1 DLO I 22 5/8" 26 5/8" GLASS DLO GLASS ULU FRENCH DOOR W/SIDLITE 6' IL iT 3116" MAX. UNIT WIDTH 36 3/16" MAX SIDELITE-WIDI K 33 5/8" MAX TH PANEL WIDTH MAX. UNIT HEGHT 94 5/8" 6" SIDELITE O L HEIGHT iT 83 518" SIDELITE GLASS DLO NOTE 1 SHT 1 x -1 22 5/8" 126 518" 1 GLASS DLO GLASS DLO SINGLE DOOR w/SIDELITE GO(GU//ME(e WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CW S.CC 8700/10/50 PVC SWING DOOR IMPACT �: ¢Z� Q W ❑ w Z0Z}OD=�m LL FWZF �gx Z Z 2 2 Q w W.❑ O O CI-O 4xE_w O U(nHZaF-U)n- o Z_y ZI-ern Q OZUCOZOLLU. . <�Ow—=C_ w 0�owv0cn —iw Ir a =~x W�wCn Q. r n o: D_ ? �/ No 58201 40" MAX SINGLE _yI DOOR WIDTH max'* 37 5/8" MAX t} STATE OF DOOR WIDTH i��$•.`0mov- 08/06/2020 95 3/16" PANEL LUCAS A. TURNER, P.E. HEIGHT FL PE # 58201 2428 Old Natchez Trc TH Camden, TN 38320 84 3116' PH. 941-380-1574 DOOR GLASS SHEET DESCRIPTION: PLO GENERAL NOTES AND 1 ELEVATIONS ._ DRAWN BY: DATE: AIDE 09/08/11 DWG#: REV.: CWS-641 D SCALE: SHEET 1:35 2 OF 12 40" MAX. SINGLE DOOR WIDTH 37 5/8" MAX — PANEL WIDTH 26 518" GLASS DLO 81/2' NOTE: HINGE SPACINGS FLUSH 81" ARE 8-1/2" FROM MAX UNIT r�OLT 21 5/16" ENDS AND 21-5116" MAX. O.C. UP TO HEIGHT 81" UNIT HEIGHT. 79 3/16" PANEL X HEIGHT 68 3116' GLASS DLO SEE E 4 NOTSHT 1 8 1/2" f SINGLE DOOR 79" MAX. FRENCH DOOR WIDTH 37 5/8" MAX. PANEL WIDTH 26 5/8" GLASS DLO I FLUSH AA � BOLT OLT iEIGHT 79 3/16" PANEL X G G X HEIGHT 68 3/16' SEE GLASS NOTE 4 DLO SHT 1 A 36 3/16" MAX — 151 3/8" MAX UNIT WIDTH — 79" MAX FRENCH DOOR WIDTH SIDELITE WIDTH 33 5/8" MAX. " 37 5/8" MAX — PANEL WIDTH PANEL WIDTH 11" FLUSH dAX. BOLT JNIT 1EGHT 78 5/8" DOD SIDELITE X X 0 PANI HEIC HEIGHT 67 5/8" 68 3/16" SIDELITE DOOR GLASS SEE GLASS DLO NOTE4 DLO SHT 1 22 5/8" 26 5/8" GLASS ULU GLASS ULU FRENCH DOORw/SIDELITES 6" 2 L iT FRENCH DOOR 36 3/16" MAX. - SIDELITE WIDTH 33 5/8" MAX — PANEL WIDTH 22 5/8" GLASS DLO 8t MAX UNIT HEIGHT 78 5/8" PANEL HEIGHT 67 5/8" GLASS n SIDELITE 112 3/8" MAX UNIT WIDTH 36 3/16" MAX 40" MAX SIDELITE WIDTH DOOR WIC 33 5/8" MAX 37 5/8" MA ' PANEL WIDTH rPANEL WIDTH s� � FLUSH OLT BOLT 1EIGHT 9 3 DOD 78 5/8" PANI SIDELITE Q o X Q HEIC HEIGHT 67 5/8° 68 3116" SIDELITE DOOR GLASS GLASS DLO DLO 22 5/8" 26 5/8" GLASS DLO GLASS DLO SINGLE DOORv{/SIDELITES (C880gogomp WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CWS.CC 8700/10/50 PVC SWING DOOR IMPACT a F- Z 3 ¢Z3: pW0 QW00 O LL. ; uwi >.0O01�E � FWZI-�:22 Z O Z=2<wwop 01-0 Q=�_W 0 o Ov7�-ZD-Hc4n- z Q p =_z?Ow Z0wZp�U <�OWOFpz Fa- K"H}��:02 W LLwW�0-1 to owFnW. d D_ _~W W�Wy . D. F- n. D_ n. INGLE `* No.58201 TH ' �1 = `*r CA— 0 �� STATE OF �8�• "c0 V-. L I :L 08/06/2020 HT LUCAS A. TURNER, RE. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 IEET DESCRIPTION: GENERAL NOTES AND ELEVATIONS LAWN BY: DATE: ADE 09/08/11 VG #: REV.: CW S-641 D ALE: SHEET 1:35 3 OF 12 QUANEX DURASEAL or, CARDINAL XL EDGE or, KODISPACE 4SG TPS I.G. SPACER GLASS TYPE A 1" OVERALL 3/16" TEMPERED 5116" AIRSPACE 112" LAMINATED 3/16" ANNEALED .105 DUPONT PVB INTERLAYER 3/16' ANNEALED SIKA - SIKAFLEX 552 or HENKEL - PURFECT GLAZE "H' 314" GLASS BITE QUANEX DURASEAL or, CARDINAL XL EDGE or, KODISPACE 4SG TPS I.G. SPACER GLASS TYPE B GLASS TYPES MAX. UNIT HEIGHT _ SI ELITE SINGLE FRENCH 81 A A A 97" B B B 1" OVERALL 3116" TEMPERED 3/8" AIRSPACE 7/16" LAMINATED 3116" ANNEALED .090 SENTRY GLASS IONOPLAST INTERL,PiYER 3/16" ANNEALED SIKA - SIKAFLEX 552 or HENKEL- PURFECTGLAZE"H" 3/4" GLASS BITE SETTING 3LOCKS PER FBC 2411.3.3.1 o8obbm" WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CWS.CC 8700/10/50 PVC SWING DOOR IMPACT z � <Z� P ❑w0 ¢wow Z WJO 0 Zw§>-0w�m U. �w�ZF-fig= z zx�ao'w00 O OF O Q=F= U 0r4 �Z d F-n)IL z p =--Z)U- Q Z U rA .z O tL U- � �WOI=ZZ w 0aILL �aiowmw Z O J. rn F- D ww a F Mw Of = a No. 58201 _'t� STATE OF 08/06/2020 ' LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 IEET DESCRIPTION: GLAZING DETAILS LAWN BY: DATE: ADE 09/08/11 VG #: REV.: CWS-641 D .ALE: SHEET 1:1 4 OF 12 .IN'�ERIOR SECTION VIEW A -A INTERIOR SECTION VIEW B-B ALTERNATE1 MORTISE LOCK w/ FLUSH BOLT ITEMS NOT SHOWN FOR CLARITY: 10-12, 13, 15-17, 22, 43, 48, 54. 57-58 ITEMS NOT USED IN VERSION SHOWN: 2-3, 8-9, 15-16, 25-28, 30-34, 36.40, 43, 52-53, 60, 62, 65-66, 72, 76 Cr��ffl WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 www.CwS.CC 8700/10/50 PVC SWING DOOR IMPACT Z �: <Z3: ow0 ¢w00 Z W J ❑ o Zw� O >—Oofzm � LL hwZF-gx Z Zx2Qwwoo 0 O�-O a=�w Co U UF-ZaProa. V) 4 OZUUzo U ry MgOwOFZUj Z of w OOKr}»ow�w LL�nw 0�tnF- COE w x~� Ww L F- a w n. _ IIf No. 58201 r� 1Itl STATE OFZr lilt 08/06/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl' Camden, TN 38320 PH. 941-380-1574 SECTION VIEWS SINGLE DOOR DRAWN BY: DATE: AIDE 09/08/11 CWS-641 D :ALE: SHEET 1:2 5 OF 12 INTERIOR SECTION VIEW C-C 086290M- WINDOW SYSTEMSLLB 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 8700/10/50 PVC SWING DOOR IMPACT a Z � <Z� Z Woo ow J O 0 w O ZoZ LL PwZF-�2x Z Z=2a1)'wp0 O OF-O ¢=F.C� U 0U)F-Zc- Pcon. Z p =-Z?Uy Q Z_UmZO.LLU. } Q�Qpw-=O? �K P- 3 L Z aco z=- a�JOm- � _~Of W�wm. n F- D W a Olt jillil No 58201' �a �� STATE OF j? 08/06/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old. Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 SECTION VIEWS FRENCH DOOR NOTE: VERTICAL SECTION SIMILAR ITEMS NOT SHOWN FOR CLARITY: ADE 09/08/11 TO SINGLE DOOR, SEE SHEET 5 10-13, 15-17, 22, 26-28, 36-39, 43, 54, 57 DWG #: REV.: ITEMS NOT USED IN VERSION SHOWN: CWS-641 D 8-9, 15-16, 25, 40, 42, 45116, 48, 52-53, 58, 60, 74, 76 SCALE: SHEET 1:2.5 6 OF 12 L!JTERIOR SECTION VIEW D-D SEALANT APPLIED TO ADJOINING FACES BY INSTALLER ERIi SECTION VIEW E-E SEALANT APPLIED TO ADJOINING FACES BYINSTALLER #10 HEX WASHER HEAD TEK JOINING DOOR FRAME TO SIDELITE. 6" FROM TOP AND BOTTOM 17' MAX. O.C. #10-24 x 1-3/4" TYPE F THRU HINGE INTO SIDELITE AT EACH HINGE. SEE SHEETS 1 & 3 FOR HINGE SPACING. ITEMS NOT SHOWN FOR CLARITY: 10-11, 16, 22, 28, 43. 57 ITEMS NOT USED IN VERSION SHOWN: 1-3, 6-15, 17-18, 20-21, 23-24, 26-27, 30-39, 41, 44-46. 48-52, 54-56, 58-61, 63-71, 74-76 001290go.0 - WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 8700/10/50 PVC SWING DOOR IMPACT a Z � <Z� Z W J O aW000 w o ZOwZ}.0C' LL Fw�ZF-�:g=- Z Z=2<ww00 O OHO Q=FW U UrghZELHc)(L V) Z p �—Z�Utn Q ZUr)ZOLLO . fy <—OWOFZZ WCd LL (n 0 W a a0 W F=.. Z W= X Cl) JA.I1-� ��pHN�en Noo..r58^2001 STATE OF „ti ��OR10 08/06/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 SECTION VIEWS ATTACHED SIDELITE AIDE 09/08/11 JG 0: REV.: CWS-641 D ALE: SHEET 1:2 7 OF 12 PARTS LIST PARTS LIST �y WINDOWSYSTEMS WINDOW S1 E AVE. OCALA, LORI34474 OCA A, FLORIDAA3 WWW,CWS.CC rrEM I PART# IDESCRIPTION MATERIAL REM PART# DESCRIPTION MATERIAL 1 H•1833 MAIN FRAME, HEAD ALUM 51 P-5131 GASKET DOORSILL BACK FOAM 2 H-1857 ASTRAGAL, INAC VE, FD, PVC ALUM 52 P-5134 SCREW, #10 X 1-3/4" FLAT SQUARE TYPE F HINGE 3 H•1858 ASTRAGAL ACTIVE, FD PVC ALUM 53 P-5151 GASKET, SIDELITE FOAM 54 P-5157 SCREW #10-24 x 1/2", FI Undercut PH 18-8SS KEEPER 4 H-1860 REINFORCEMENT' VERT. ALUM 55 P-5158 BOTTOM SEAL UMBER .. 8700/1 O/5O PVC SWING DOOR IMPACT o w O rn w 0 p Z w .1 ❑ ¢ Z w w ZOZ w=!=I'- ❑ a rn � } 0 0_ 3: m LL F- w z F 3: � _ Z Zx2¢D:w00 0 O r O d a = � � 0 Z - w Z Z_ F Co �_ ¢ O z O ❑ Z =O w 0 I--'O Z r a � w — = O a af qo U Z uj w 0 ❑ it r o w w a Z = a Of 0 � w >- O w r O a x co a.a F a a I, 5 H-1861 REINFORCEMENT; HORIZ ALUM `6 P-5172 WSTP X.187 TRI FIN BLACK 6 FI-1878 MAIN FRAME, SILL. ALUM `57 P-5174 .370 SCREW #8 X 3/4" HEX WASHER HEAD, FRAME 7 H 1880 MAINFRAME, JAMB ALUM 5B P-5183 SCREW PH,FL MS, SS PLUNGER Ss 8 1 -1881 MAINFRAME, SIDELITE DOOR ALUM 59 S-1783 OLD,#8-3HI H RI THRESHOLD HIGH RISE ALUM ALUM 9 FI-1900 MAINFRAME, SIDELITE JAMB, HEAD, SILL ALUM 60 S-1784 INSERT, REINFORCEMENT ALUM 10 P-5615 SETTTING BLOCK 85 DUR 1/8 X 1 X 2 RUBBER 61 S-1806 COVER JAMB, ANCHOR ALUM 11 1 IS]KAFLEX 552 or PURFECT GLAZE "H" 62 S-1816 COVER JAMBS HEAD SILL SIDELITE ALUM 12 1 P-3503 I SCREW #S X 1/2" PH TRUSS SS ASTRAGAL CAP 63 S-1817 DRIP CAP ALUM 13 P-3511 SCREW #8 x 5/8" SQ. PAN TEK TIEROD BRKT 64 S-1840 COVER HEAD, ANCHOR ALUM 14 P-3587 SCREW #8 X 1", PH FLAT TEK @ ASTRAGAL, INSERT,LOCK 65 S-1849 INSERT INACTIVE PNL, LOCK HARDWARE 15 P-3767 SCREW, #10 X 1" HEX HEAD, TEK SIDELITE 66 S-1859 COVER ASTRAGAL, FD ALUM 16 P-4146 SCREW #8 X 3/4 PHIL, FLAT SS TEK SIDELITE SHIM 67 S-1864 INSERT FRONT BTM ATTACH SILL _ ALUM 17 P-4278 FUZZY PAD, .200" x 1.250" W/ADHESIVE 68 S-1865 INSERT, BACK BTM ATTACH SILL _ ALUM 18 P 4522 #10 x 1 1/4" PH FLAT SMS - HINGE a PANEL 69 S-1915 BASE, SWEEP ALUM 19 P-4774 WSTP, BULB/LEADS PANEL 70 S-1916 DRIP COVER SWEEP _ ALUM 20 P 4790 FLUSH BOLT, ASSM, TOP/BTM 71 S 6083 PANEL TOP/BTM RAIL, SIDES -DOOR PVC 21 P-4794 SCREW #8 x5/8" SQ.FLATTEK INSERTATTACH 72 S-6083 PANEL, TOP/BTM RAIL, SIDES - SIDELITE PVC 73 S-6084 GLAZING BEAD 1" PVC 22 P-4802 ALL THREADED ROD TIE ROD 74 K1888 REINFORCEMENT VERT.SINGLE DOOR ALUM 23 P 4807 HINGE, GUIDE 75 GLASS SEESHEET4 24 P48081P4809 _ HINGE, SET 25 P-4814 WSTP, .50X.75g FOLDED BULB SEAL, SIDELITE 76 1+1862 REINFORCEMENT VERT. ALUM a�T_OR�Fgi��i' 6 i *� �_1* NO 58I y —�, !�= ' T�� STATE OF =� _ ������NAA-Lo; 08/06/2020 77 P-4887 LOCK MORTISE 26 P-4863 LOCK STRIKE PLATE RIKE PLATE _ __ _ _ _ — — HEAD SILL ALL FRAMES ARE MECHANICALLY FASTENED ' ALTERNATE APPROVED LOCKSETS: ;AMEX GRADE 2 LOCKSET AND DEADBOLT 28 P 4866 GUIDE THINO IE ROD NYLON 29 P 4871 TIE ROD BRACK ZINC 30 P-4885 SHOOT BOLT, TO , 31 P 4886 SHOOT BOLT, BOTTOM 32 P-4851 LOCKBAR INACTIVE, 8 FT 32 P 4884 LOCKBAR MULTI OINT, SPT, 8 FT 32_ —P_-4901— L06KBAR Ml1LTr DINT, 4 T, 6'8 FT _ 32 P-4902 LOCKBAR INACTIVE, 6'8 FT 33 P4903 HANDLE SET, ACTIVE 34 P-4905 HANDLE SET, INACTIVE 35 P4913 WSTP, .50X.50 FOLDED BULB SEAL, DOOR 36 P4917 CAP, ASTRAGAL, OUTSIDE NYLON 37 P-4918 GUIDE, FLUSH BOLT, INACTIVE PNL 38 P4922 COVER INTERIOR FLUSH BOLT NYLON LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 39 P-4925 CAP, —ASTRAGAL, INSIDE NYLON 40 P-4926 SHIM, SIDELITE, DOOR SHIPPING BLOCK NYLON 41 P4927 GUIDE, FLUSH BOI T NYLON 42 P-4930 SCREW, #10 X 1- 14" HEX HEAD TEK SIDELITE ATTACH 43 P-4933 NUT, 3/8"-16 FLANIGED W/ SERRATED LIP, SS, PANEL SHEET DESCRIPTION: BOM 44 P-4934 SCREW, #12-24 X 1/2", PH FLAT, MS, HINGE 45 P4936 DOOR KNOB, ACTIVE PANEL ' 46 P4937 IDEADBOLT, ACTIVE PANEL ' DRAWN BY: ADE DATE: 09/08/11 47 P4969 SCREW, #10 X 2" REINF. ATTACH. 48 P-4997 STRIKE, DEADBOLT 49 P-5127 SCREW, #12 X 2", PH PAN, SMS, ANCHOR DWG O: CWS-641 REV.: D 50 P-5130 GASKET, DOORSILL, FRONT FOAM SCALE: 1:1 SHEET 8 OF 12 13/4"—�{ 23/4" -I 27/16" 1 1.1 r �y1S41N1(Yl4I/UU(y� . 4 9/16' I I I 5/8° WINDOW SYSTEMS 59 Y. 1900 SW 44TH AVE. 1 2 1 3116" 1116" 9/� 64 OCALA, FLORIDA 34474 1/16" 1/16' 1 7/16' 1 L WW W.CW S.CC 72 HEAD COVER -1840 DOOR HEAD-1833 4 5/16" 8700/10/50 PVC 51/2" 5/8" SWING DOOR 1/1s" 1�z 1ra•—{ y IMPACT 4 9/16'� 1/4" I 61 3/7/8—I�fiO 5/16' T Q Z � ¢ZO I- 0w0 rnW O 3 E�u 6 1/16" FILLER -1784 Z w-1 0 ¢ r Z w 1 1/16 O 1/16' REINFORCEMENT FRAME COVER- 1806 0 Q 0 �} O of � m L w ZOZ--r lLL I-w ZF-��2 518" Z zx�a�Wp0 2 3/8" -�j O O 1- 0 ¢ = F. W DOOR SILL-1878 PVC DOOR PANEL - 6083 I I U V rn rp Z a F' rn IL 3 62 11r16" 3 4 pZVUjzoLL0 I- 4 9/16' ^I F� 1 112" 3/� " 1/16" I I Q p w� MID_ PVC GLAZING BEAD - 6084 w Z SIDELITE COVER -1816 I w U) w w O w U) w 7 5 45/16" I I j`4 0 w�0 aim} 1 9l16" �� I 1'1/8' w F a [r a 1/16" 215/16" 1/16" 1/16" 1 15/16" DOOR JAMB-1880 518" 63 DRIP CAP -1817 49/16" REINFORCEMENT -1861 REINFORCEMENT -1858 1/16 BASE SWEEP -1915 �No.58201 69 11/2" ""fit Z I► 1 1!2" 314" �41 STATE OF f? 21/2" �I� �( �I� i�� p�ORA� '`b`��` U 70 1116' 4 6 68 13116" 116' '',''�'OI A 1� ``` 2 15/16" 13t 6" 1/16" 1/16" 2 15116" 1/16" DRIP COVER -1916 SIDELITE-1881 INSERT, BACK -1865 08/06/2020 L L LUCAS A. TURNER, P.E. 4 9/16"REINFORCEMENT - 1862 REINFORCEMENT-1860 I FL PE # 58201 � I i 2428 Old Natchez Trc Trl Camden, TN 38320 3" 9/16' PH. 94TION: 1574 9 il SHEET DESCRIPTION: 21/16" 66 T© EXTRUSIONS 1l16' 65 11116" �pFll--1116" Lrm___�u 2, 1/16' 1 ih 1/8" INSERT, FRONT -1864 DRAWN BY: DATE: SIDELITE-1900 AIDE 09/08/11 INSERT, INACTIVE PNL -1849 DWG#: REV.: ASTRAGALCOVER-1859 CWS-641 D SCALE: SHEET NOTE: ALL EXTRUSIONS ARE 6063-T6 ALUMINUM 1:2 9 OF 12 ANCHOR @ MIDSPAN (TYP.) 4' (TYP') 6MAX (TYP.) 4" (TYP.) � 6- MAX. (TYP.)� )MAX. O.C. (TYP.) 0 X 2" (TYP.)'WOOD/METAL NOTE 2 ANUNUK L MI 6- MAX (TYP.) 6" MAX. (TYP.) 17" MAX INSTALLATION O O.C. (TYP) I�ANCHOR (TYP,) SIDELITE DOOR SIDELITE ANCHORLAYOUT- (FLANGE) r SIDELITE DOOR DOOR SIDELITE ANCHOR LAYOUT -(FLANGE) . CIRCLED ANCHOR LOCATIONS REQ'D ONLY IN WOOD AND METAL INSTALLATIONS. DO NOT INSTALL THESE ANCHORS INTO MASONRY. .TAL SEE NOTE 2 INSTALLATION ANCHOR (TYP.) NOTES: 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD. 2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESEN�,'.. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 3. ANCHOR TYPE, SIZE, SPACING APID EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 11. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1, SHEET 11. 6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE. INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 4" FOR MASONRY; 2-3/16" FOR HINGES (ALL SUBSTRATES), 1" FOR WOOD AND METAL. 1 8. WOOD OR MASONRY OPENINGS, PUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 11. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. I ' 9. SEALING AND FLASHING STRATEEIIIIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOC�IMELS: FMA/AAMA 100(FIN WINDOWS), Fi A/AAMA200(FLANGE WINDOWS), FMAIWDMA 250(BOX WINDOWS), FMA/AAMAANDMA 300(EXTERIOR DOORS) I �lytfnvU�W/r�L�- WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CW S.CC 8700/10/50 PVC SWING DOOR 'IMPACT a z ¢z0 ow0 Qo Z WJO . f- W 0 ZwZ}OofZE LL PT z��2x Z Z2¢1rw00 O OF-O ¢xFaf O 'QyHZaF.rnn- o Z p z, Z=O- Q zowzo L0 > Q�pwOxOZ F w H 7 > w ooQ 7Jo W Co Z a OJ U)H � _~� Wy W} rq . ��1llldill(I// `vJCPS a TUR,t,F� No.58213 STATE OF /?j fill II00 08/06/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc TrI Camden, TN 38320 PH. 941-380-1574 ANCHOR SCHEDULE ANC NOTES ADE 1 09/08/11 . CWS-641 D ALE: SHEET 1:8 1 10 OF 12 TYPICAL HEAD ANCHORAGE SUBSTRATE BY OTHERS SEE TABLE 1 PERIMETER SEALANT ' 0' �� __jjL BY INSTALLER IU�81L INSIDE AND OUT CONTINOUS DBL 1/4" BEADS OF SEALANT AROUND PERIMETER AT ALL INDICATED POINTS BETWEEN FRAME AND SUBSTRATE BY INSTALLER. PERIMETER SEALANT BYINSTALLER INSIDE AND OUT SUBSTRATE BY OTHERS SEE TABLE 1 / A VERTICAL SECTION 11 TYPICAL SILL ANCHORAGE MIN. EDGE DIST. SEE TABLE 1 MIN. EMBEDMENT SEE TABLE 1 —1/4" MAX SHIM INTERIOR INSTALLATION ANCHOR SEE TABLE 1 MIN. EMBEDMENT SEE TABLE 1 MIN. EDGE DIST. SEE TABLE 1 INTERIOR CONTINOUS DBL 1/4" BEADS OF SEALANT AROUND PERIMETER AT ALL INDICATED POINTS BETWEEN FRAME AND SUBSTRATE BY INSTALLER. TABLE 1: APPROVED INSTALLATION FASTENERS SUBSTRATETYPE ANCHOR TYPE MIN. EMBEDMENT MIN. EDGE DIST. CONCRETE (2.85 KSI MIN.) 14' ELCO ULTRACON 1-3/4" 2-1/2" HOLLOW OR GROUT -FILLED CMU (ASTM C-90) 1/4" ELCO ULTRACON 1-1/4" 2-1/2" 2XMIN. SOUTHERN PINE (G=0.55) 1/4" ELCO ULTRACON 1-318" 7/8" 2XMIN. SOUTHERN PINE (G=0.55) , #12 WOOD SCREW 1-3/8" 718" 16 GAUGE (0.060") MIN. #12-14 HILTI KW IK-FLEX OR ITW FULL THREAD 1/2" STEEL STUD (33 KSI YIELD MIN) TEKS SELF -DRILLING SCREW THRU 0.060" 1/8" ALUM. (6063-T5 MIN.) OR #12 GRADE 5 SELF TAPPING / FULL THREAD 1/2" 1/8" STEEL (33 KSI MIN.) DRILLING SCREW THRU 0.125' HINGE ANCHORS INTO CONCRETE (2.85 KSI MIN.) 3116" ELCO ULTRACON 1-3/4" 2-1/2" HINGE ANCHORS INTO HOLLOW OR GROUT -FILLED 3/16" ELCO ULTRACON 1-1/4" 2-1/2" CMU (ASTM C-90) HINGE ANCHORS INTO 2X MIN. SOUTHERN #10 WOOD SCREW 1-3/8" 7/8" PINE (G=0.55) HINGE ANCHORS INTO 16 GAUGE (0.060") MIN. #10-16 HILT] KW IK-FLEXOR ITW FULL THREAD 1/2" STEEL STUD (33 KSI YIELD MIN) TEKS SELF -DRILLING SCREW THRU 0.060" HINGE ANCHORS 1/8" ALUM. (6063-T5 MIN.) OR #10 GRADE 5 SELF -TAPPING / FULL THREAD 112" 1/8" STEEL (33 KSI MIN.) DRILLING SCREW THRU 0.125" INSTALLATION ANCHOR SEE TABLE 1 HINGE ANCHOR SEE TABLE 1 r 1/4" MAX. SHIM MIN. EMBEDMENT SEE TABLE 1 T / MIN. EDGE DIST. SEE TABLE 1 HINGE MIN. EDGE DIST. / SEE TABLE 1 PERIMETER SEALANT BY INSTALLER Imo' {I1 INSIDE AND OUT —I HINGE MIN. EMBEDMENT SUBSTRATE BY OTHERS SEE TABLE 1 SEE TABLE 1 g HORIZONTAL SECTION 11 TYPICAL JAMB / HINGE ANCHORAGE 2 13116„ - ANCHORSTHRU HINGE (TYP.) 215/16 MAX. SEE NOTE NOTE: HINGE SPACINGS ARE: 8-1/2" FROM ENDS 21-5/16" MAX. O.C. FOR UP TO 81" UNIT HEIGHT 20" MAX. O.C. FOR OVER 81"UNIT HEIGHT ,I Tr.) HINGE 1_4YOUT 1:3 09290 . WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 8700/10/50 PVC SWING DOOR IMPACT a z 3 ¢z3r Z WJO ¢F'Z0W o zWZ>-Um5m u. �W�zl-�gx Z Zx:EaWWpO O OHO ¢_mow 0 UUF-za-Pco5. O Z�Co—ZF-Z)CO F--u-�00LLZ Q?: O W F F O_ W 0 w W U O.J co n 0H-. D- F OL 0: D \\Illllll////j \`��\vJCpSA i_URyF/Q/i��i 'y\CBN�eti y! No. 58201 = —i �!f!� ►� STATE OF A40 08/06/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Td Camden, TN 38320 PH. 941-380-1574 SHEET DESCRIPTION: INSTALLATION DETAILS DOOR DRAWN BY: DATE: ADE 09/08/11 DING#: REV.: CWS-641 D SCALE: SHEET 1:2 11 OF 12 f TYPICAL HEAD ANCHORAGE SUBSTRATE BY OTHERS SEE TABLE 1, SHT 11 PERIMETER SEALANT BYINSTALLER INSIDE AND OUT CONTINOUS DBL 1/4" BEADS OF SEALANT AROUND PERIMETER AT ALL INDICATED POINTS BETWEEN FRAME AND SUBSTRATE BY INSTALLER. PERIMETER SEALANT BYINSTALLER INSIDE AND OUT SUBSTRATE BY OTHERS SEE TABLE 1, SHT 11 —MIN. EDGE DIST. SEE TABLE 1, SHT 11 MIN. EMBEDMENT SEE TABLE 1, SHT 11 114" MAX. SHIM INTERIOR INSTALLATION ANCHOR SEE TABLE 1, SHT 11 . MIN. EMBEDMENT SEE TABLE 1. SHT 11 MIN. EDGE DIST. SEE TABLE 1, SHT 11 V: INTERIOR —1/4' MAX SHIM 08419km5 MIN. EMBEDMENT WINDOW SYSTEMS II11I`` i�II`II SEE TABLE 1, SHT 11 1900 SW 44TH AVE. CONTINOUS DBL 1/4" BEADS OF SEALANT OCALA, FLORIDA 34474 AROUND PERIMETER AT ALL INDICATED WW W.CWS.CC - POINTS BETWEEN FRAME AND SUBSTRATE �EDGIEDIST. BY INSTALLER. MSEE / TABLE 1, SHT 11 8700/10/50 PVC SWING DOOR INSTALLATION ANCHOR SEE TABLE 1, SHT 11 —z IMPACT d J F Z Q . Ow0W-jo awooW / Z w Z I ¢OO �oa�m LL Z F-w Zr-i:2=. :. Z=2¢ww00 O .0 r O °x o ¢ ra (7r Zarrn _ OZU ��r•, A �' Q Zo . <�ow-MO- PERIMETER SEALANT BY INSTALLER F O� F } 5 � O g . INSIDE AND OUT Z rn W 0 -1 W Fw- o SUBSTRATE BY OTHERS 0 w P 0 0- :r SEE TABLE 1, SHT 11 D HORIZONTAL SECTION w D_ _ I.- a- of. . a N 12 YPICAL JAMB ANCHORAGE No 58201 �* =XI l(tl= I` STATE of r=�Z- t. 08/06/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Td Camden, TN 38320 PH.941-380-1574 SHEET DESCRIPTION: - INSTALLATION DETAILS SIDELITE DRAWN BY: DATE: ADE 09/08/11 DWG #: REV.: CWS-641 D SCALE: SHEET 1.2 12 OF 12 I f I