HomeMy WebLinkAboutProject InformationPro ect Summary Job: GARAGERIGHT -�+ Wrightsoft° ry Date: NOV. 16, 2021 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772466-6796 Email: QUICKCALCS@AOL.COM Project• • For: SAEED MODEL 5500 WINTER GARDEN PARKWAY, FORT PIERCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 22362 Btuh Structure 23142 Btuh Ducts 8371 Btuh Ducts 11933 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 30733 Btuh Use manufacturer's data n Rate/swing multiplier Equipmenf load 0.95 33321 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4225 Btuh Ducts 3348 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Btuh Area (ftz) 2262 2262 Equipment latent load 7574 Volume (ft3) 19978 19978 Air changes/hour 0.32 0.16 Equipment Total Load (Sen+Lat) 40895 Btuh Equiv. AVF (cfm) 107 53 Req. total capacity at 0.70 SHR 4.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade RHEEM Model Cond RA1648AJ 1 NA AHRI ref Coil RH1T4821MTANJA AH R I ref 8080956 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 7.7 kW Sensible cooling 32550 Btuh Heating output 26369 Btuh Latent cooling 13950 Btuh Temperature rise 15 OF Total cooling 46500 Btuh Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.82 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -F- wrightsoR® 2021-Nov-16 11:57:29 •°tl i4 °^• a�� o• Right -Suite® Universal 2021 21.0.02 RSU08101 Page 1 ..s\Wrightsoft WAC\SAEED MODEL- GARAGE RIGHT.rup Calc = MJ8 Front Door faces: W 1- Wrightsoft Right-J® Worksheet Job: GARAGE RIGHT Entire House Date: NOV. 16, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772.466-6796 Email: QUICKCALCS@/\OL.COM 1 Room name Entire House BEDROOM 4 2 3 Exposed wall Room height 196.0 ft 8.8 ft 31.0 ft 8.0 It heat/cool 4 Room dimensions 1.0 x 175.0 ft 5 Room area 2262.0 ft2 175.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btu ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-5ocs 0.125 n 3.50 1.9T 438 349 1223 668 120 100 350 191 2 glazing, clr low-e 0.650 n 18.20 14:99 15 0 273 225 0 0 0 0 T 2 glazing, clr low-e 0.650 n 18.20 14.99 20 0 364 300 20 0 364 300 2-glazing, clr low-e. 0.650 _ .n - _ _ 18.20 _14.99 _14.99 54 _ - - -0 _976 _ _ 804 __0 0 _ _- - 0 _ 0 _ V+/ 11 13A-5ocs . _ 0.125 a 3.50 1.91 490 447 1565 855 40 40 140 76 2 glazing, clr low-e 0.650 a 18.20 33.77 3 0 55 101 0 0 0 0 II�C 2 alazina, clr lower 0.650 e _ _ 18.20. 33.77 _ 40 0 728 _ 1351 0 0 - 0 _ 0 13A-5ocs 0.125 s 3.50 _ 1:91 , 270 202 707 386 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 20 20 364 300 0 0 0 0 -2 glazing, clr low-e _ _ . 0.650 - s . 18.20 _ , 14.99 _ _ 48 48 . _874 _. _720 _ _ _ _ 0 _0 _ -. 0 - . 0 13A-5ocs 0.125 w 3.50 1.91 464 406 1421 776 88 68 238 130 glazing, clr low-e 0.650 w 18.20 33.77 3 0 55 101 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 15 0 273 507 0 0 0 0 2 glazinq,_clr low-e- 0_650 18.20 _-- 33.77 0 728 20 . _ 364 _ 675 C _ , _ - 16B80md- _ _ -,. _ 0- 032 _w. 0.90- _ __1.60 __- _ _40 _ _ _ 2262 _ 2262 _ -. -,_ _ 2021 _ - __1351 _ _ _ 8619 _ 175 _ __0 _ 175 - - _ _ . _ 157 260 F 22A-tph- 1.35 8 - 38.02 _ _ 0.00 _ , . 2262 _ 196 _ _ 7453 _ _ _ _ 0 _ _ 175 - - _ 31 _ _ _ 1179 _ 0 6 c)AED excursion 0 132 Envelope loss/gain 19083 12064 2792 1785 12 a) Infiltration 3279 878 489 131 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 10200 1000 Subtotal (lines 6 to 13) 22362 23142 3281 2916 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 105 47 14 Subtotal 22362 23142 3385 2963 15 Duct loads 37% 52% 8371 11933 37% 52% 1267 1528 FTTotal room load 30733 35075 4653 4491 Air required (cfm) 1550 1550 235 198 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -r- 2021-Nov-16 11:57:29 =� Right -Suite® Universal 2021 21.0.02 RSU08101 Page 1 ..s\Wrightsoft H\/AC\SAEED MODEL- GARAGE RIGHT.rup Calc = MJ8 Front Door faces: W -�- wrightsoft Right-J® Worksheet Job: GARAGE RIGHT Entire House Date: NOV. 16, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name BATH 3 BEDROOM 3 2 Exposed wall 5.0 ft 10.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 10.0 x 5.0 ft 50.0 ft2 1.0 x 160.0 ft 160.0 ft2 Ty Construction number U-value (Btuh/ft22F) Or HTM (Btu ft) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 113A-5ocs 2 glazing, clr low-e 2 glazing, clr low-e -6.125 0.650 01650 n n n 3.50 18.20 1820 1.91 14.99 14.99 6 0 0 0 0 0 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 --G I��G 11 2 glazing, clr low-e, 13A-5ocs 0.650 0.125 n a 18.20 3.50 14.99 1.91 _ 0 0 0_ 0 0 0 0 0 0 0 0 0 0. 0 0 0 � 2 glazing, clr low-e 2 glazinq, clr low- 13A-5ocs 0.650 0.650 0.125 a e_ s 18.20 18.20 3.50 33.77 _ 33.77 1.91 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e glazing, clr low-e 0.650 0.650 s . s 18.20 18.2Q 14.99 .14.99 0 _ _ 0 0 10 0 _ 0 0 0 0 _ 0 0 0 0 0 0 0 .2 13A-5ocs 2 glazing, clr low-e 2 glazing, clr low-e 0.125 0.650 0.650 w w w 3.50 18.20 18.20 9.91 33.77 33.77 40 0 0 40 0 0 140 0 0 76 0 0 80 0 0 60 0 0 210 0 0 115 0 0 - G II�;C C 2 glazinq, clr low- 16B30md 0.650 0.032 w_ _ - 18.20 0.90 .. 33.77 1.60 _ _ .0 _ _ 50 _ 0 50 0 45 _ _ _ 0 60 ._ _ 20 _ 160 0 1.60 _ 364 _ 143 675 256 F 2 4h. 1.358 38.02 0.(0 _ 50 5 190 6 160 10, 380 0 6 c)AED excursion -24 200 Envelope loss/gain 375 132 1098 1246 12 a) Infiltration 79 21 158 42 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 500 1000 Subtotal (lines 6 to 13) 454 653 1255 2289 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 88 41 110 57 14 Subtotal 542 694 1366 2345 15 Duct loads 37% 52% 203 358 37% 52% 511 1209 Total room load 745 1052 1877 3555 Air required (cfm) 38 46 95 157 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. -Fk- 2021-Nov-16 11:57:29 �� Right -Suite® Universal 2021 21.0.02 RSU08101 Page 2 ...s\Wrightsoft HVAC\SAEED MODEL- GARAGE RIGHT.rup Calc = MJ8 Front Door faces: W -�+ Wrightsoft° Right-J® Worksheet Job: GARAGE RIGHT Entire House Date: NOV. 16, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax: 772-466-6796 Email: QUICKCALCS@/\OL.COM 1 Room name CLST 3 BATH 2 2 Exposed wall 2.0 ft 5.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 10.0 x 2.0 ft 10.0 x 5.0 ft 5 Room area 20.0 ft2 50.0 ft2 Ty Construction U-value Or HTM Area (ft-) Load Area (ft2) Load number (Btuh/f? °F) (Btuh/f?) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-5ocs ` 0.125 n 3.50 1.91 0 0 0 6 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 D 0 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2-glazing, clr low-e_ 0.650 n .18.20 _ 14.99 _ - _ 0 _ - 0 0 0 0 - _- _ ..0 0 0 V� 11 13A-5ocs 0.125 a 3.50 1.91 0 0 0 0 0 0 - 0 0 2 glazing, clr low-e 0.650 e 18.20 33.77 0 0 0 0 0 0 0 0 FL--G 2alazina, clr lower _ - 0.650 , e 18.20 33.77 _ 0 0 0 0, _0 0 0 13A-5ocs - 0.125 .. s 3.50 1.91 0 0 0 0 -0 0 0 0 _ 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e _ 0.650 s,- _18.20 14,99 _ - 0 0 _ 0 _ 0 .- 0 - 0 - _ 0 0 VVjj11 13A-5ocs 0.125 w 3.50 1.91 16 16 56 31 40 37 130 71 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 3 0 55 101 �-G 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 l�-GG 2 glazinq, clr_low-e 0.650 -2 _ w 18.20 _ _ 33.77 .. ___0 _ - _ -0 _0. _ _ 0 _ _0 -0 , _ _ 0 0 _ - C 16B-30md 0.0 - 0.90 1.66 20 _ 20 - 18 32 _ 50 50 _ _ 45 - 80 F _ . 22A-tPh _. 1.358 38.02 _ -0,00, _. .. _ -20, -? 7.6 . 0 ... 50 - 5 - 190 0 6 c)AED excursion -3 17 Envelope loss/gain 150 601 419 269 12 a) Infiltration 32 8 79 21 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 400 Subtotal (lines 6 to 13) 182 69 498 690 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -182 -69 171 72 14 Subtotal 0 0 669 762 15 Duct loads 37% 52% 0 0 37% 52% 250 393 Total room load 0 0 919 1155 Air required (cfm) 01 0 46 51 Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed. 1 �- wr7ggtitsol`[m ACC1,_ Right-SuiteC� Universal 2021 21.0.02 RSU08101 2021-Nov-16 11:57:29 Page 3 ...s\Wrightsoft HVAC\SAEED MODEL- GARAGE RIGHT.rup Calc = MJ8 Front Door faces: W - Weightsoft' Right-J® Worksheet Job: GARAGE RIGHT Entire House Date: NOV. 16, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 2 CLST 2 2 Exposed wall 34.0 ft 2.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 205.0 ft 10.0 x 2.0 ft 5 Room area 205.0 ftz 20.0 ftz Ty Construction U-value Or HTM Area (ft-) Load Area (W) Load number (Btuh/ftz °F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cocl Gross N/P/S Heat Cool 6 lb13A-5ocs 0.125 n 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing, cir lower 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 _n_ 18.20 _ -14.99 0 -. 0 .. _0 0 _ 0 __0 0 0 11 13A-50cs 0.129 a 3.50 1.91 48 48 168 92 0 0 0 0 2 glazing, cir low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 alazino, clr low-e 0.650 a 18.20, _ 33.77 0 _ _ _0 _ -0 _ -0 _0 - 0 _ , 0 0 13A-5ocs 0.125 s 3.50 1:91 120 100 350 191 0 0 0 0 2 glazing, cir low-e 0.650 s 18.20 14.99 20 20 364 300 0 0 0 0 2.glazing„clr.low_e_ 0 650 . s _ %20 14.99 ._ _._0 -0 . 0 __ 0 _... 10 - .. - __0 0 - _ ._0 13A5ocs 0.125 w 3.50 1.91 104 89 312 170 16 16 56 31 2 glazing, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 -G 2 glazing, cir low-e 0.650 w 18.20 33.77 15 0 273 507 0 0 0 0 2 glazinq, cir low- 0.650 1.8.20 33.77 -__0 0 , _ . _ 0 -0 -- _ - 0 0 0 0 _ C - 16B-30md ---- - 0.032 --- _w_ - 0.80 --- -- 1.60 -- . 265 --- 205 - ---- - - 164 - --- 328 - __0 -20 - 20 . _ - 18 - - - - 32 - - - F- 22A-tPh - 1.358 , - _ 38.02 _ - _ _ 0, 00 _ 205 _ _ , 34 _ _-1293 _ . - 0 .,- 20 2 _ - 76 - 0 6 c)AED excursion 46 -3 Envelope loss/gain 2943 1634 150 60 12 a) Infiltration 537 144 32 8 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1000 0 Subtotal (lines 6 to 13) 3480 2778 182 69 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 105 47 -182 -69 14 Subtotal 3584 2825 0 0 15 Duct loads 37% 52% 1342 1457 37% 52% 0 0 Total room load 1 1 T4926 4281 0 0 Air required (cfm) 248 189 0 0 Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed. Right -Suite® 2021-Nov-16 11:57:29 ACCA Universal 2021 21.0.02 RSU08101 Page 4 ...s\Wrightsoft HVAC\SAEED MODEL- GARAGE RIGHT.rup Calc = MJ8 Front Door faces: W wrightsoftRight-J® Worksheet Job: GARAGE RIGHT Entire House Date: NOV. 16, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name HALL3 HALL 2 2 Exposed wall 0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 5.0 x 5.0 ft 5.0 x 5:0 ft 5 Room area 25.0 ftz 25.0 ft2 Ty Construction U-value Or HTM Area (W) Load Area (ft-) Load number (Btuh/f? °F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-5ocs 0.125 n 1 99_0 2 glazing, clr lower 0.650 n � 9.20 18.20 14 99 0 0 0 0 0 0 0 0 - E 2.glazing', clr low-e 0.650 18.20 14 99 0 0 0 0 0 0 0 0 ---G 2:glazing, clr_low-e.--. - -_ . _ -_ _0.650 n_- 18.20- 14.99 - �..- 0 0._ �-- Q - --0 11 13A-5ocs 0.125 e- 3.50 1.91 0 _ 0 _-. 0 0 0 - 0 - --0- 0. 6 2 glazing, clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazino, clr low-e_,. _._ 13A-56cs . . . _0.650 0.125 e... s 18.20- 3:50 _ -_ 33.77 1:81 - _ _0 0 _ . . , -0 0 ., _- _. __0 0 _- .-- _0 0 __.. -_ ._0 0 .. _ 0 0 --- _-- --- _0. 0 _ _ _. '0 0 2 glazing, cir low-e 0.650 s 18.20 14.99. 0 0 0, 0 0 0. 0 0 2.glazing, clrjow7e -_ ... - Q.650 _ s . 18.20 __. 14.99," -0 0 - _. 0 -- 0 - - p - -0 _ 0.125 w 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 1113A-5ocs 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 .2pillEgii1q, pIr low-e --- 18.20 33.77_------ 0- ... 0 0 �_: 16B 30md - -0.650._w_ - 0_032 . .. 0•90 .-__�1 6Q - 25 .._.__-0 -25 ._ 4 -- -0 ----- -4Q ---0--_- - 25 - -.__o ., - 25 - - - - .,ff _. __---0- 40 F 22A-tDh- _.._. 1.358 _ r...-.-3802_ 000 __...,.-25 0 -- 0 -- 0 - 25 0 6 c)AED excursion -1 -1 Envelope loss/gain 22 39 22 39 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 22 39 22 39 Less external load 0 .0 0 0 Less transfer 0 0 0 0 Redistribution -22 -39 -22 -39 14 Subtotal 0 0 0 0 15 Duct loads 37% 52% 0 0 37% 52% 0 0 FTTotal room load T0 0 0 0 Air required (cfm) 0 0 0 0 Calculations aDDroved WACCA to meet all reouirements of Manual J 8th Ed. �"Id- wrightsof't� 2021-Nov-16 11:57:29 Right -Suite® Universal 2021 21.0.02 RSU08101 Page 5 ...s\Wrightsoft HVAC\SAEED MODEL- GARAGE RIGHT.rup Calc = MJ8 Front Door faces: W wrightsoft Right-J® Worksheet Job: GARAGE RIGHT Entire House Date: NOV. 16, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LIVING RM GREAT RM 2 Exposed wall 19.0 ft 15.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 19.0 x 20.0 ft 1.0 x 353.0 ft 5 Room area 380.0 ft2 353.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (13tuh/ft2-°F) (Btu ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vt/ - 13A5ocs 0.125 n 3.50 1.91 19D 136 477 261 6 0 0 0 2 glazing, clr low-e 2 glazing, clr low-e 0.650 0.650 n n 18.20 18.20 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2.glazing, clr low- _ _0.650 _ n 18.20 14.99 54 0 _ 976 804 0 0 0_ 0. V 11 13A-5ocs 0.125 a 3.50 1.91 0 - 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 alazina. cir lower -- 0.650 a 18.20 3.3.77 _ _ _0 0 _ - _ 0 __ _ 0 0 _ 0 0 _0 13A-5ocs 0.125 s 3.50 1.91 0 _ 0 0 0 150 102 357 , 195 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2.glazing, cir lower 0.650 -s- 18.20 14.9.9 . ., 0 _- - _0 _ 0 . -. - 0 .. . - 48 .. 48 8.74 720 0:125 w 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 N13A-5ocs 2 glazing, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2_glazinq, clr low-e 0.650 w ._ 18.20 _ 33.77 0 0 0 0 ___0 __0 0 c 16B-30md 0.032 - - _ 0.90 _ _ 1.60 _ 380 _ _0 360 _ 340 _ 608 - _ 353 - 353 - - 316 _ _ 565 _1.358_ _ - 38.02 _ 0.00 -, -380 _ _ _. 19 _ _- _ 722 .. -_ - 0 .353 15 _ _ 570 0 0 6 c)AED excursion -99 -34 Envelope loss/gain 2516 1573 2117 1445 12 a) Infiltration 375 100 296 79 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1000 1000 Subtotal (lines 6 to 13) 2891 2674 2413 2525 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 10 6 10 14 Subtotal 2896 2683 2419 2534 15 Duct loads 37% 52% 10841 1384 37% 52% 9051 1307 Total room load 3980 4067 3324 3841 Air required (cfm) 201 180 1168 170 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. -rk- 2021-Nov-16 11:57:29 �� " Right -Suite® Universal 2021 21.0.02 RSU08101 Page 6 ...s\Wrightson H\/AC\SAEED MODEL- GARAGE RIGHT.rup Calc = MJ8 Front Door faces: W 1- wrightsoft Right-M Worksheet Job: GARAGE RIGHT Entire House Date: NOV. 16, 2021 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax: 772466-6796 Email: QUICKCALCS@J\OL.COM 1 Room name M BATH M WIC 2 Exposed wall 29.0 ft 7.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 16.0 x 8.0 ft 12.0 x 7.0 ft 5 Room area 128.0 ft2 84.0 ft2 Ty Construction U-value Or HTM Area (ftz) Load Area (ft2) Load number (Btuh/ft2-°F) (Stuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 -- - 13A-5o cs -�- - 0.1-25' n 3.50 1.91. ._... 128 113 -396 216 0 0, - 0 0 2 glazing, clr low-e 0.650 n 18.20. 14:99 95 _ 0 273 225 0 6 0 0 2 glazing, clr lower 0:650 n 18.20 %99 0 0 0 0 0 0 0 0 2.glazing, clr lower _ 0.650 ._n._ 18.20 - _ 14.99. 0 - 0 _ - Q _ - 0 _ - . - 0 _ . -0-- - 0 0 11 13A - 6 2,5- a 3.50 1.91 64 - 64 _ _ _, 224 _ 122 _ 56 56 196 167 2 glazing, clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing. clr low-e_ _ _ -0.650 . _e _ _ __18.20 33.77 _ 0 0 0 0 _ _ 0 _ _ __ _- 0 _ 0. __ 0 13A-5ocs 0.125 s 3.50 1.91 0 0 0 , 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 _2 glazing, clr lower _ 0.650 _s 18,20 .. 1499 - _ 0 ,.... _0... 0 0 _ 0 0 G 13A-5ocs 0.125 w 3.50 1.91 40 40 140 76 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 - 2 glazing, cir low-e 0:650 w 18.20 33.77 0 0 0 0 0 0 0 0 clr lows 0.650 w - __1.8.20 _ 33.77 _ _ _ - - 0- ____0 _ 0 , 0 _ C_ _. .Z.glazinp, 161330md _-_---- _ ,--- - 0;032 -- _--- _ _0.90. - -_-1-60'- --_128._._ - ..128 -. ._._ 115 _ __ ----- 205 _- _ 84 - _ _--134 F _.._ 22A-tph-- - - - .1.3.58. _ - 38.02. - 0.00 128 _...... 29 _ .. 1103, _ ..._. 0 7 266 _ _. _ 6 6 c)AED excursion -35 -17 Envelope loss/gain 2250 810 537 225 12 a) Infiltration 458 123 110 30 b) Room ventilation 1 0 0 1 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 200 Subtotal (lines 6 to 13) 2708 933 648 454 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2708 933 648 454 15. Duct loads 37% 52% 1014 481 37% 52% 243 234 FTTotal room load 3721 1414 890 689 Ajr required (cfm) 1881 621 45 30 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -1ia- wri_gF�tsoftm 2021-Nov-1611:57:29 Aa"cn` Right -Suite® Universal 2021 21.0.02 RSU08101 Page 7 ...s\Wrightsoft HVAC\SAEED MODEL- GARAGE RIGHT.rup Calc = MJ8 Front Door faces: W -�- wrightsoftRight-J® Worksheet Job: GARAGE RIGHT Entire House Date: NOV. 16, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS a(��AOL.COM 1 Room name MASTER BEDROOM KITCHEN 2 Exposed wall 14.0 ft 13.0 ft 3 Room height 8.0 ft heat/coal 10.0 ft heat/cool 4 Room dimensions 1.0 x 259.0 ft 16.0 x 13.0 ft 5 Room area 259.0 ft2 208.0 ft2 Ty Construction U-value Or HTM Area (W) Load Area (ft2) Load number (Btuh/W °F) (Btu ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vh13A-5ocs 0.125 n 8.50 9.99 0 0 0 6 0 6 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low- 0.650 n 18.20 _ 14.99 _- 0 0 0 0 0 0 0 0 T_:2 11 13A-5ocs 0.125 a 3.50 1.91 112 72 252 138 130 127 445 243 2 glazing, clr low-e 0.650 a 18.20 33.77 0 0 0 0 3 0 55 101 2 olazina. clr low-e 0.650 _ e 18.20 33.77 40 0 728 1351 0 0 0 0 13A50cs 0.125 s 3.50 1.91 _ 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s_ 18.20 14.99. - 0 0 0 0 0 0 0 0 13A-5ocs 0.125 w 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 -G 2 glazing, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazinq, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 C _ 16B-30md _ 0.032 0.90 _ 1.60 _ _ 259 259 232 414 208 208 _ 186 3.3_ 3 F 22A-tph 1.358 38.02 0.00 259 14 532 0 208 13 494 0 6 c)AED excursion -33 -85 Envelope loss/gain 1744 1870 1180 592 12 a) Infiltration 221 59 256 69 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1000 1800 Subtotal (lines 6 to 13) 1965 2929 1436 2460 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 3 5 14 Subtotal 1965 2929 1439 2466 15 Duct loads 37% 52% 736 1510 37% 52% 539 1271 Total room load 2701 4440 1978 3737 Air required (cfm) 1361 196 100 165 Calculations aDoroved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-16 11:67:29 �� "^ Right -Suite@ Universal 2021 21.0.02 RSU08101 Page 8 ..s\Wrightsoft HVAC\SAEED MODEL- GARAGE RIGHT.rup Calc = MJ8 Front Door faces: W - + Wrightsoft Right-J® Worksheet Job: GARAGE RIGHT Entire House Date NOV. 16, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS ,AOL.COM 1 Room name UTILITY RM AHU CLST 2 Exposed wall 3.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 8.0 x 5.0 ft 40.0 ft2 3.0 x 5.0 ft 15.0 ftz Ty Construction U-value Or HTM Area (ft-) Load - Area W) Load number (Btuh/ftz °F) (Btu ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A50cs 0.125 n 3.50 1c91 0 0 0 0 0 0 0 0 2 glazing, clrlow-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr lower. 0.650 n 18.20 14.99 , 0 0 0 0 0 0 0 0 11 2 glazing, cir low-e 13A5ocs 0-.5 0 125 -.-n a 18.201 3.50 - 14.99 1.91 0 0 0 0 0 0 0 0 _. _ 0 0 _0 0 0 0 0_ 0 � 2 glazing, clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazina. clr low-e 13A-50cs _0:650 0.125 e- s 18.20 3.50 33.77 1.91' _0 0 0 0 0 0 0 0 0 0 - 0 0 _ 0, 0 - 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr-lower 0.650 _ s- 18.20 14.99.. 0 _ 0 . - 0 0 0 0 0 0_ 13A-5ocs 0.125 w 3.50 1.91 24 24 84 46 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 F--G 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazinq,-clr iow-e. 0.650 w 18.20 33.77 0 0 0 _0 C 16B-30md b.032 _ 0.90 1:66 _ 40 _ _0 46 _0 36 _0 64 _ 15 15 13 _0 24 F 22A-tph_ 1.358 _ - 38A2 _. _0.-00 _ _ 40 _ 3 114 0 15 0 0 0 6 c)AED excursion -40 -1 Envelope loss/gain 234 70 13 23 12 a) Infiltration 47 13 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1000 0 Subtotal (lines 6 to 13) 281 1082 13 23 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 5 9 -13 -23 14 Subtotal 286 1091 0 0 15. Duct loads 37% 52% 107 563 37% 52% 0 0 Total room load 394 1654 0 0 Air required (cfm) 1 1 20 73 0 0 Calculations aDDroved bvACCA to meet all requirements of Manual J 8th Ed. -r'{*- wrightsoft� 2021-Nov-16 11:57:29 ACCk Right -Suite® Universal 2021 21.0.02 RSU08101 Page 9 ...s\Wrightsoft HVAC\SAEED MODEL- GARAGE RIGHT.rup Calc = MJ8 Front Door faces: W -�- wrightsoft® Right-M Worksheet Job: GARAGE RIGHT Entire House Date: NOV. 16, 2021 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name PANTRY CLST 4 2 Exposed wall 5.0 ft 2.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 9.0 x 5.0 ft 10.0 x 2.0 ft 5 Room area 45.0 ft2 20.0 ft2 Ty Construction U-value Or HTIA Area (ft-) Load Area (ft-) Load number (Btuh/ftz °F) (Btu ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NOS Heat Cool Gross N/PIS Heat Cool 6 0.650 n 8.50 0 0 0 0 0 0 0 0 2 gla5ocs 2 glazing, cir low-e 0.650 n 18.20 4.91 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2-glazing, cir lower 0.650 - -n 18.20 _ _ 14.99 . _ 0 . _ _0 _ _ - _ 0 0 _ _ - . 0 - 0 -0 0 y/ {L-�� 11 13A-5ocs 0.125 a 3.50 1.91 40 40 140 76 0 0 0 0 2 glazing, clr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazina. cir low-e 13A-5ocs 0.650 0.125 e_ s 18.20 3.50 _33.77 1.91 0 0 0 0 0 0 0_ 0 0 0 0 0 0 0 0 0 VI! 2 glazing, or low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 - s 18.20 . _,14.99 .. 0 _ 0 0 0 _0 _ 0 0 _ 0 13A-5ocs 0.125 w 3.50 1.91 0 0 0 0 16 16 56 31 2 glazing, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 N 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, clr.low-e 0.650 w 18.20 - 33_.77 0 0 0 _ 0 0 0 0 0 C 16B-30md 0.032 _ 0.90 1.60 .- 45 ._ _ 45 40 _ 72 20 _ 20 18 32 F 22 4i h- 1,358 , - 36.02, _ - - OAO . _ _ - . 45 - 5 . 190 0 _ 20 2 76 0 6 c)AED excursion -17 -3 Envelope loss/gain 370 132 150 60 12 a) Infiltration 79 21 32 8 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 300 0 Subtotal (lines 6 to 13) 449 453 182 69 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 5 9 -182 -69 14 Subtotal 455 462 0 0 15 Duct loads 379%. 52% 170 238 37% 52% 0 0 Total room load 625 700 0 0 Air required (cfm) 32 31 1 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -� �- w""' trYghsft- �� ""°^mo""^ Right -Suited 2021-Nov-16 11:57:29 Universal 2021 21.0.02 RSU08101 Page 10 s\Wdghtsoft WAC\SAEED MODEL- GARAGE RIGHTrup Calc = MJ8 Front Door faces: W - wrightsoft® Duct System Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS a(AOL.COM For: SAEED MODEL 5500 WINTER GARDEN PARKWAY, FORT PIERCE, FL Job: GARAGE RIGHT Date: NOV. 16, 2021 By: Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply / return available pressure 0.500 / 0.500 in H2O 0.500 / 0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual air flow 1550 cfm 1550 cfm Total effective length (TEL) 190 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 c 1155 46 51 1.000 6.0 Ox 0 VIFx 32.0 115.0 st2 BATH 3 c 1052 38 46 1.000 6.0 Ox 0 VIFx 50.7 135.0 st4 BEDROOM 2 h 4926 248 189 1.000 8.0 Ox0 VIFx 33.3 115.0 st2 BEDROOM 3 c 3555 95 157 1.000 8.0 Ox0 VIFx 52.6 135.0 st4 BEDROOM 4 h 4653 235 198 1.000 8.0 Ox0 VIFx 54.8 135.0 st4 GREAT RM c 3841 168 170 1.000 8.0 Ox 0 VIFx 29.6 115.0 st2 KITCHEN c 3737 100 165 1.000 8.0 Ox0 VIFx 8.7 115.0 st1 LIVING RM h 3980 201 180 1.000 8.0 Ox0 VIFx 49.2 135.0 st4 M BATH h 3721 188 62 1.000 6.0 Ox0 VIFx 36.1 135.0 st3 M WIC h 890 45 30 1.000 5.0 Ox0 VIFx 35.0 135.0 st3 MASTER BEDROOM c 4440 136 196 1.000 8.0 Ox0 VIFx 38.1 135.0 st3 PANTRY h 625 32 31 1.000 5.0 Ox0 VIFx 8.3 115.0 st1 UTILITY RM c 1654 20 73 1.000 6.0 Ox0 VIFx 7.4 115.0 st1 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 568 582 1.000 741 12.0 0 x 0 VinlFlx st2 st2 Peak AVF 1030 992 1.000 738 16.0 0 x 0 VinlFlx st3 Peak AVF 369 289 1.000 676 10.0 0 x 0 VinlFlx SO st1 Peak AVF 520 558 1.000 711 12.0 0 x 0 VinlFlx -�- wrightsoft® 2021-Nov-16 11:57:35 ^� •µ*.�• �.��e•w� ��mroM Right -Suite® Universal 2021'21.0.02 RSU08101 Page 1 �C+� ...s\Wrightsoft HVAC\SAEED MODEL- GARAGE RIGHT.rup Calc = MJ8 Front Door faces: W Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 ox0 1550 1550 0 0 0 0 Ox 0 VIFx -Fk wrightsoft® Awla�/entiAwlb�ti.,rymny Right -Suite® Universal 2021 21.0.02 RSU08101 Zdk ...s\Wrightsoft HUAC\SAEED MODEL- GARAGE RIGHT.rup Calc = MJ8 Front Door faces: W 2021-Nov-16 11:57:35 Page 2 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.