Loading...
HomeMy WebLinkAboutProduct Approval Exterior DoorsBCIS Home ! Log In ( User Registration Hot Topics i Submit Surcharge Stats & Facts Publications ! Contact Us I BCIS Site Map Links Search i Holida 'nos`,, Product Approval i-; ,USER: Public User RECEIVED tie w' u: Product Approval Menu > Product or Application Search > Application List > Application Detail JAN 12 2022 FL'# FL14850-R4 Application Type Revision St. Lucie County Code Version 2020 Permitting Application Status Approved Comments REVIEWED FOR Archived CODE .COMPLIANCE LUCIE Product Manufacturer Custom Window Systems Inc.ST. COUNTY BOCC Address/Phone/Email 1900 SW 44th Avenue Ocala, FL 34474 (352) 368-6922 Ext 291 jlathrop@cws.cc Authorized Signature ]ay Lathrop jlathrop@cws.cc FILE COPY Technical Representative ]ay Lathrop Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Quality Assurance Representative Cal Ledy. . Address/Phone/Email 1900.SW 44th Ave. Ocala, FL 34474 (352)368-6922 cledy@cws.cc Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Lucas Turner Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 07/21/2028 Validated By Steven M. Urich, PE 13 Validation Checklist - Hardcopy Received Certificate of Independence FL14850 R4 COI EvalReport641D.pdf Referenced Standard and Year (of Standard) Standard AAMA/WDMA/CSA 101/I.S.2/A-440 ASTM E1886-13a ASTM E1996-17 PA TAS/201/202/203 Year 2008 2013 2017 1994 FL14850 R4 Equiv 87XX LM Equivalency_pdf Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/10/2020 Date Validated 08/10/2020 Date Pending FBC Approval 08/19/2020 Date Approved 1 10/13/2020 Summa"-:ofProducts FL:# Model,`Numberor Narrie'•" Descriptlon 14850.1 FD-8750, Impact. FD-8750 French Door, SD-8700 Swing Door, SLT-8710 Sidelite, Impact. Limits of Use ' Installation Instructions Approved for use in HVHZ: Yes FL14850 R4 II CWS-641D.pdf Approved for use outside HVHZ: Yes Verified By: Lucas Turner 58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: +70/-70 Evaluation Reports Other: Large Missile French Door w/ Sidelights, Max. French FL14850 R4 AE EvalReoort641D.p,df Door 6' x 8', Max. Single Door 3' x 8', Max. Sidelight 3' x 8', DP Created by Independent Third Party: Yes +/- 70 psf. Glass complies to ASTM E1300. Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Co right 12007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement i Under Florida law, email addresses are public records. If you do not want your a -mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emaiis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: SWRI Crelt Card`: Safe. I SWING DOOR & SIDELITE - LARGE MISSILE IMPACT 79" MAX. FRENCH DOOR WIDTH 37 5/8" MAX. PANEL WIDTH 26 5/8" GLASS DLO _ II I - r AA AAX JNIT iEIGHT 1{I C 95 3/16" MAX. X X PANEL HEIGHT 84 3/16" GLASS SEE DLO NOTE 4 i A 11 FRENCH DOOR TABLE OF CONTENTS GENERAL NOTES 8 ELEVATIONS 1-3 GLAZING DETAILS....................................4 SECTION VIEWS.....................................5-7 BO M............................................................8 EXTRUSIONS.............................................9 ANCHOR SCHEDULE 8' NOTES........... 10 INSTALLATION DETAILS .................... 111-12 r 1 C �— FLUSH BOLT ON INACTIVE PANEL B 11 40" MAX SINGLE - DOOR WIDTH 37 5/8" MAX. — PANEL WIDTH 26 5/8" GLASS DLO 97" MAX. UNIT HEIGHT 95 3/16' 1 MAX PANEL B HEIGHT 84 3/16" GLASS DLO 36 3/16" MAX. SIDELITE WIDTH 33 5/8' MAX. PANEL WIDTH 22 5/8' GLASS DLO D I 97" MAX. UNIT E E HEIG 1 D 94 5/8' I 12 MAX I O PANEL HEIGHT 83 5/8" GLASS DLO i . I 1 D � 12 SIDELITE A 81/2" NOTE: HINGE SPACINGS ARE 8-1/2" FROM ENDS AND 20" MAX. O.C. 20" FOR 81" TO 97" UNIT HEIGHT. SEE ' NOTE 4 i 13. QUALIFIED ALTERNATIVE LOCKSEi PEADR(JLT HARDWARE IS GRADE 2 BY PAMEX AND DELANY. I A 14. MAX. PANEL WIDTHS APPLY TO ALL CONFIGURATIONS, MULLED OR NON -MULLED UNITS. I SINGLE DOOR GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS D SIGNED Ijj�ND MANUFACTURED TO COMPLY WITH THE FLORIDA Bull DING 01tj (FBC), CURRENT EDITION INCLUDING THE HIGH VELD( ITY H 12 1CANE ZONE (HVHZ) AND IS RATED FOR WIND ZONE 4 MISSILE LEVEL IMPACT USE AS DEFINED IN ASTM E 1996 PER THE FBC. 2. GLAZING OPTIONS: (SEE SHEET 4) 3. CONFIGURATIONS: SINGLE OUTSWING, SINGLE OUTSWING W/SIDELITE(S), FRENCH DOOR(S), FRENCH,DOOR(S) W/SIDELITE(S), SIDELITE NOT ATTACHED. 4. LOCK OPTIONS: UP TO 6'8": A. DOUBLE BORE w/TWO (2) INTERIOR FLUSH BOLTS. HANDLE SET @ 36' B. MORTISE LOCK w/ TWO (2) INTERIOR FLUSH BOLTS. HANDLE SET @ 34' C. MULTIPOINT (4 PT.) HANDLE SET @ 34" ABOVE 6'8": A. MULTIPOINT (5 PT.) HANDLE SET @ 34" 5. DESIGN PRESSURE RATING: -NEGATIVE DESIGN LOADS BASED ON, TEST D PRESSURL iI ND GLASS TABLES ASTM E-1300-04e0l/99. I -POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE AND GLASS'TABLES ASTM E-1300-04e01/09. 6. ANCHORAGE: THE 33 1/3% STRESS INCREA4 HAS NOTI BEEN USED IN THE DESIGN OF THIS PRODUCT. SEE SHE�:TS 11-12 FOR ANCHOR DETAILS. WINDLOAD DURATION FACTOR Cdl=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 7. PRODUCTS APPROVED FOR IMPACT RESISTANCE. SHUTTEI,S ARE NOT REQUIRED. 8. ALL FRAMES ARE PROCESSED AND SCREWED TOGETHER. PANELS ARE PROCESSED AND ASSEMBLED VIA TIE ROD. 9. SERIES / MODEL DESIGNATION SD-8700, FD-8750, SLT-8710. 10. THE DESIGNATION X AND 0 STAND FOR THE FOLLOWING: X = OPERABLE SASH, 0 = FIXED SASH 11. SECTION CALLOUTS APPLY TO ALL CONFIGURATIONS IN A SIMILAR LOCATION. 12. INTERIOR FLUSH BOLTS ON ACTIVE PANEL TO BE ENGAGED PRIOR TO SEVERE WEATHER. TYPE MAX. PANEL SIZE DESIGN PRESSURE RATING IMPACT RATING SINGLE 37-5/8" x 95-3/16" +/- 70 PSF , LARGE MISSILE IMPACT FRENCH SIDELITE 33-5/8" x 94-5/8" 080900•0 WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 8700/10/50 PVC SWING DOOR IMPACT Z ?: QZ�: O GWOw. Z WJO w ZOZ ���� O Qv>� LL Pw z��g= Z Z=2Qww00 O OF O Q=Fw C)O(01-ZdF-yO- Zo ZO_(D_Zno- Q D_g}(nU u7 w LLAnwW0Wco (Dw n It Z p WF=-O a a w wo \\111A11//// n 7_UrzyFq���� No 58201 Ile_ =A� * Jul= T� STATE OF 08/06/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 GENERAL NOTES AND ELEVATIONS Lucas Turner DRAWN BY: DATE: 2020.08.10 AIDE 09/08/11 12:04:58 DWG X: REV.: -05'00' CWS-641 D SCALE: - SHEET 1:35'. 1 OF 12 151 318" MAX. UNIT WIUIH 36 3/16" MAX 79" SIDELITE WIDTH MAX. FRENCH DOOR WIDTH 33 5/8" 37 5/8" MAX. PANEL WIDTH PANEL WIDTH 17" AAX. )NIT iEIGHT SIDELITE Q X X O PANT HEIGHT HEIG FLUSH BOLT 83 5/8" ON 84 3/16- SIDELITE SEE INACTIVE DOOR GLASS INC PANEL GLASS DLO L SF 1 M DLO —11j 22 5/8" 26 5/8" GLASS DLO GLA55 ULU FRENCH DOOR w/SIDELITES 1153116" MAX.UNITWIUIH 36 3/16" MAX. 79" SIDELITE WIDTH MAX FRENCH DOOR WIDTH - 33 518" MAX. 37 5/8" M1 — --- - PANEL WIDTH-_ DOOR WIE 17" ' nAX 1NIT iEGHT 94 SIDELITE 518" X 9531 HEIGHT PANT FLUSH HEIC 83 5/8" BOLT SIDELITE ON 84 3/16' GLASS UNOTE4 INACTIVE DOOR DLO PANELGLASS �AL� 11 1� += DLO 22 518" t 26 5/8" GLASS DLO UI-A55 ULU FRENCH DOOR w/SIDLITE �lytyNl COZ WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA34474 W W W.CW S.CC 8700/10/50 PVC SWING DOOR IMPACT �: "CZ�: O �woo -IT o �w�z13:g= Z Z= 2 Q 2 w O O 0 Oro ¢=F� L) 0(n I-ZaF-rna rn OZowzo V Y Q�pw-=OZ IY X � U) 0 I~11 00�U)i0w U)w wrnw 0.jcn1- 0 � _FR wN �W D. �- D- X IL 76 3/16" MAX. UNIT WIDTH - 36 3/16" MAX - SIDELITE WIDTH X. 33 518" MAX I TH PANEL WIDTH 97" MAX UNIT HEIGHT 94 518" 16" SIDELITE L HEIGHT O X HT 83 518" 84 SIDELITE GLASS DLO SEE NOTE 4 SHT 1 Dt GI DL 22 5/8" 26 5/8' GLASS DLO GLASS DLO SINGLE DOOR I w/SIDELITE 40" MAX SINGLE DOOR WIDTH 37 5/8' MAX QOOR W IDTH 953116 PANEL HEIGHT 3/16" J;ptS A. TS 47, No..58201 STATE OF * ?� 08/06/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc TrI Camden, TN 38320 PH.941-380-1574 IEET DESCRIPTION: GENERAL NOTES AND ELEVATIONS LAWN BY: DATE: AIDE 09/08/11 VG M REV.: CWS-641 D .ALE: SHEET 1:35 2 OF 12 40" MAX. SINGLE DOOR WIDTH 37 5/"MAX. PANEL WIDTH' 26 518" GLASS DLO 81/2" NOTE: HINGE SPACINGS -'FLUSH 81" ARE 8-1/2" FROM MAX UNIT BOLT I 21 5/16" ENDS AND 21-5/16" MAX. O.C. UP TO HEIGHT 81" UNIT HEIGHT. 79 3/16" PANEL p X HEIGHT �T 68 3/16- GLASS DLO SEE NOTE4 SHT 1 I 8 1/2" 'l I 1 SIP�I33LE DOOR 36 3/16" MAX — SIDELITE WIDTH 33 5/8" MAX -- PANEL WIDTH 81" MAX. UNIT HEIGHT 78 5/8' SIDELITE 0 HEIGHT 67 5/8" SIDELITE GLASS 79" MAX FRENCH DOOR WIDTH 37 5/8" MAX PANEL WIDTH 26 5/8" GLASS DLO I� I FLUSH 4AX- BOLT JNIT iEIGHT 79 3/16" PANEL x p p X HEIGHT 00 68 3/16' SEE GLASS NOTE4 DLO SHT 1 FRENCH DOOR 36 3/16" MAX. SIDELITE WIDTH 33 5/8" MAX PANEL WIDTH 22 5/8" GLASS DLO 6T MAX UNIT HEIGHT 78 5/8" PANEL O HEIGHT 67 518" GLASS DLO i —151 3/8" MAX UNIT WIDTH 112 3/8" MAX. UNIT WIDTH 79" MAX FRENCH DOOR WIDTH 36 3/16" MAX. 40" MAX. SINGLE ^j SIDELITE WIDTH DOOR WIDTH "37 5/8" MAXPANEL WIDTHI PANEL WID H rPAN/EL WIDTHI FLUSH 8FLUSH BOLT UNIT BOLT 79 3/16" HEGHT 79 3/16" DOOR DOOR 78 5/8" 1 PANEL PANEL SIDELITE p HEIGHT X X O HEIGHT X F SEE NOTE 4 SHT 1 22 5/8""4 F- 26 518" FSS DLO GLASS DLO FRENCH DOOR w/SIDELITES I HEIGHT 68 3/16" 67 5/8" 68 3/16- DOOR SIDELITE I DOOR GLASS GLASS DLO GLASS DLO DLO I I 22 5/8" 26 5/8' GLASS DLO GLASS DLO SINGLE DOOR w/SIDELITES I Ogalgb • WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 8700/10/50 PVC . SWING DOOR IMPACT a Z 3. ¢Z� I- DwQ awow Z wJ0 w ZOZ w_ZF LL Pw ZI-3:2T O OFOaQwpO 0 000 H-ZD-P U)a- 0 Z-) ZI-7c Q QZQMZOoQ } 1 �''20 OZ g� H I-�Z Q Of }/U vi w OCOZ!EW�QJrAI- a X : w�:wm a D- Of IL �pSATu �t// No.58201A0 \iice !W_ \ STATE OF Jul 08/O6/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 SHEET DESCRIPTION: GENERAL NOTES AND - ELEVATIONS DRAWN BY: DATE: ADE 09/08/11 DWG#: REV.: CWS-641 D SCALE: SHEET 1:35 3 OF 12 QUANEX DURASEAL or, CARDINAL XL EDGE or, KODISPACE 4SG TPS I.G. SPACER 13LASS TYPE A 1" OVERALL 3/16" TEMPERED 5/16" AIRSPACE 1/2" LAMINATED 3/16" ANNEALED .105 DUPONT PVB INTERLAYER 3/16" ANNEALED SIKA - SIKAFLEX 552 or HENKEL - PURFECT GLAZE "H" II 3/� S BITE QUANEX DURASEAL or, CARDINAL XL EDGE or, KODISPACE 4SG TPS I.G. SPACER I GLASS TYPES MAX. UNIT HEIGHT SIDELITE SINGLE FRENCH 61 A A A 9T' B B B 1" OVERALL 3116" TEMPERED 3/8" AIRSPACE 7/16" LAMINATED 3/16" ANNEALED 090 SENTRY GLASS IONOPLAST INTERLAYER 3/16" ANNEALED SIKA - SIKAFLEX 552 or HENKEL - PURFECT GLAZE "H" 1 3/� S BITE I WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474. www.Cws.CC 8700/10/50 PVC SWING DOOR IMPACT Z aZ3 O <wo LL �w�ZF-fig= Z Z2natYwp0 O OE-O a=F.cc U 0cnF-Za Ftn D. Z o_= Z v5 > ¢�LLw-ZOz ggOF-F-I_Z . cc w 0LL aiowv�w ZL 0-1U) of _~of w�w� D. F D. D_' O. i i Z� No 58201� STATE OF f? 08/06/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 SHEET DESCRIPTION: GLAZING DETAILS GLASS TYPE B DRAWN BY: DATE: ADE 09/08/11 ' DWG #: REV.: CWS-641 D SCALE: SHEET SETTING BLOCKS PER FBC 2411.3.3.1 1:1 40F12 I TL=RIOR I SECTION VIEW A -A INTERIOR SECTION VIEW B-B ALTERNATE 1 MORTISE LOCK w/ FLUSH BOLT ITEMS NOT SHOWN FOR CLARITY: 10-12, 13, 15-17, 22, 43, 48, 54, 57-58 ITEMS NOT USED IN VERSION SHOWN: 2-3, 8-9. 15-16, 25-28, 30-34, 36-40, 43, 52-53, 60, 62, 65-66, 72, 76 Ct LInim . WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 8700/10/50 PVC SWING DOOR IMPACT a z �: ¢z3 1,- ow0 Qw00 O ZW�Z}� OD'm LL PwZr3�2= z zx2¢r1fw00 O OF O ¢_mow 0 0(n�Za-F(n n. CO Z p �—�jU— �-U- oO LZ a�:OwFFO— F 00F}��O2 w OLL U)w fn0 Jlnw D V) H o F a o wo yJ0p11111111,/ $x ru%,, �`o a lvie,4 No.58201 *-2— STATE OF !XORID�z 08/06/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 EET DESCRIPTION: SECTION VIEWS SINGLE DOOR' AWN BY: DATE: AIDE 09/08/11 !G #: REV.: CWS-641 D, ALE: SHEET 1:2 5 OF 12 i NOTE: VERTICAL SECTION SIMILAR TO SINGLE DOOR, SEE: SHEET 5 INTERIOR SECTION VIEW C-C - _ -- - ITEMS NOT SHOWN FOR CLARITY: 10-13, 15-17, 22, 26-28, 36-39, 43, 54, 57 ITEMS NOT USED IN VERSION SHOWN: 8-9, 15-16, 25, 40, 42, 4546, 48, 52-53, 58, 60, 74, 76 V- lytynvbm•f7fli`F . WINDOW SYSTEMS ,I,zz,�/ 1900 SW 44TH AVE. OCALA, FLORIDA 34474 -. W W W.CW S.CC 8700/10/50 PVC SWING DOOR IMPACT a Z �: 4Z3: O aWrOw Z W J O r W ZOZ:7C Co _ 2CZF" Fn LL F-W �ZOF �i CC -22 Z Z224wwoo O OHO 4=FQf U Um�ZD-F.CoIL OZowzo .0 <3:owp= Z U-Z(A W OLL 0) W Cn 00 W U) W a _ w�w� �J�p$ A TU%ai No:58201 e: NTATE OF lZ�� 04ORA� �JJJIlI1111��� 08/06/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 IEET DESCRIPTION: SECTION VIEWS FRENCH DOOR LAWN BY: DATE: ADE 09/08/11 VG M REV.: CWS-641 D :ALE: - SHEET 1:2.5 6 OF 12 I INTERIOR SECTION VIEW D-D ERI SECTION VIEW E-E SEALANT APPLIED TO ADJOINING FACES BY INSTALLER #10 HEX WASHER HEAP TEK JOINING DOOR FRAME TO SIDELITE. 6' FROM TOP AND BOTTOM rl 17' MAX. O.C. Qalgbwas WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CW S.CC 8700/10/50 PVC SWING DOOR IMPACT a Z az�: O Qw00 0 ZU)§Z}occ�m LL HwZ~fig= Z Z2,2¢D-'w00 0 OH O ¢_�-Er 0 U(a�-ZLL U)a- Z Q � -5U- } ¢�¢o202: LL 0? ~ OOK}owmw Of Zw�nw O.Ju>F- Ix _~ of W� wo D- D- Of a ,�Gps n`IiUnN7j7// No- 58201 *~ OC= Xf STATE OF Z-r :• a40R10 08/06/2020 52 LUCAS A. TURNER, P.E. SEALANT APPLIED TO #10-24 x 1-3/4' TYPE F FL PE # 58201 ADJOINING FACES THRU HINGE INTO SIDELITE AT EACH HINGE. 2428 Old Natchez Trc Trl BY INSTALLER SEE SHEETS 1 8 3 FOR HINGE SPACING. Camden, TN 38320 PH. 941-380-1574 SHEET DESCRIPTION: SECTION VIEWS ATTACHED SIDELITE ITEMS NOT SHOWN FOR CLARITY: DRAWN BY: DATE: 10-11, 16. 22, 28, 43, 57 ADE 09/08/11 ITEMS NOT USED IN VERSION SHOWN: DWG#: REV.: 1-3, 6-15, 17-18, 20-21, 23-24, 26-27, 30-39, 41, 44-46, 48-52, 54-56, 58-61, 63-71, 74-76 CWS-641 D SCALE: SHEET 1:2 7 OF 12 PARTS LIST PARTS LIST `1 (/ _aalgibfim- ef/t SYSTEMS f�jj✓� WINDOW SYSTEMS 1900 SW 44TH AVE.. OCALA, FLORIDA 34474 WWW.CWS.CC ITEM PART # DESCRIPTION MATERIAL ITEM PART # DESCRIPTION MATERIAL 1 H-1833 MAIN FRAME, HEAD ALUM 51 P-5131 GASKET DOORSILL, BACK FOAMvlYtOW 2 I -1857 ASTRAGAL INACTIVE, FD, PVC ALUM 52 P-5134 SCREW, #10 X 1-3/4" FLAT SQUARE TYPE F HINGE 3 H-1858 ASTRAGAL, ACTT E FD, PVC ALUM 53 P-5151 GASKET SIDELITE FOAM 4 H-1860 REINFORCEME VERT. ALUM 54 P-5157 . SCREW #10.24 x 112" FI Undercut PH, 18-8SS KEE ER 55 P-5158 BOTTOM SEAL RUBBER 5 H-1861 REINFORCEME HORIZ ALUM 56 P-5172 WSTP .370 X .187, TRI FIN, BLACK 6 H 1878 MAIN FRAME, Si L ALUM 8700/10/50 PVC SWING DOOR IMPACT 57 P-5174 SCREW #8 X 314" HEX WASHER HEAD FRAME 7 H-1880 MAINFRAME, JA B ALUM `9 PH, FL MS, SS PLUNGER 8 H-1881 MAINFRAME SIDELITE DOOR ALUM 59 S-5783 S-1783 RISE THRESHOLD HIGH RISE THRESHOLD, HIGH ALUM ALUM 9 I _1900 MAINFRAME, SIDELITE JAMB, HEAD, SILL ALUM 60 S-1784 INSERT, REINFORCEMENT ALUM 10 P-5615 SETTTING BLOC, 85 DUR 1/8 X 1 X 2 RUBBER 61 S-1806 COVER JAMB, ANCHOR LUM 11 SIKAFLEX 552 or PURFECT GLAZE "H" 62 S-1816 COVER JAMBS HEAD SILL, SIDELITE LUM ¢ Z w o LL Z O 0 Z ¢ Y Q W w0. O a z 3 ¢ z w -1 o ¢ � Z w z O ? K - - E6 ¢ rn � y O � � m � w Z I- � g = Zx�¢Dfw00 O H O d ¢a = If X Z N W Z Z ~ � y O z U ai z 0 v - ~- LL w O O 0 Z ¢� O w F F 0_ w } C) Z O O it (D p w Tn w Z Co a W w H O a x �- F a a 3 a 12 13 P-3503 P-3511 SCREW #8 X 1 ?" PH TRUSS SS ASTRAGAL CAP SCREW #8 x 5/ .SQ PAN TEK 71EROD BRKT 64 S-1840 COVER, HEAD, ANCHOR LUM 14 P-3587 SCREW #8 X 1", PH FLAT TEK ASTRAGAL INSERT,LOCK 65 S-1849 INSERT, INACTIVE PNL, LOCK HARDWARE I 15 P-3767 SCREW, #10 X 1" HEX HEAD, TEK SIDELITE 66 S-1859 COVER ASTRAGAL, FD LUM 16 P-4146 SCREW #8 X 3/4 PHIL, FLAT SS TEK SIDELITE SHIM 67 S-1864 INSERT, FRONT, BTM ATTACH SILL ,LUM 17 P-4278 FUZZY PAD, .200" x 1.250" W/ADHESIVE 68 S-1865 INSERT BACK, BIM ATTACH SILL LUM 18 P-4522 #10 x 1 1/4", PH FLAT SMS - HINGE PANEL 69 S-1915 BASE SWEEP LUM 19 P-4774 WSTP, BULB/LEAFS, PANEL 70 S-1916 DRIP COVER SWEEP ALUM 20 P-4790 FLUSH BOLT, ASSM, TOP/BTM 71 S-6083 PANEL, TOP/BTM RAIL, SIDES - DOOR I PVC 21 P-4794 SCREW #8 x 5/8' SQ. FLAT TEK INSERT ATTACH 72 S-6083 PANEL, TOP/BTM RAIL, SIDES - SIDELITE PVC 22 P-4802 ALL THREADED OD TIE ROD 73 S-6084 GLAZING BEAD 1" PVC 23 P 4807 HINGE, GUIDE 74 H 1888 REINFORCEMENT VERT. SINGLE DOOR ALUM 75 GLASS SEE SHEET 4 24 P-480BIP4809 HINGE, SET 76 I F1862 REINFORCEMENT, VERT. ALUM _ - :- ���1llFIiNI7/�� O��OyA-BUeFp�����ii ' j*// *± No; 58201 wZ STATE OF /2�� ��tp\8 '*40� RAt— "10 �'��i�NALI��` 08/06/2020 25 P-4814 WSTP, .50X.750 FOLDED BULB SEAL, SIDELITE 77 P-4887 MORTISE LOCK 26 P-4863 LOCK STRIKE P LATE I I I },• HEAD SILL ALL FRAMES ARE MECHANICALLY FASTENED ALTERNATE APPROVED LOCKSETS: ;AMEX GRADE 2 LOCKSET AND DEADBOLT 27 P-4864 RHI NO STRIKE PLATE 28 P4866 GUIDE, TIE ROD NYLON 29 P 4871 TIE ROD BRACKET ZINC 30 P 4885 SHOOT BOLT, T P 31 P4886 SHOOT BOLT, BOTTOM 32 P4851 LOCKBAR, INACTIVE, 8 FT- 32 P4884 LOCKBAR MULTI -POINT, 5PT, 8 FT 32 P4901 LOCKBAR.MUL-TI-POINT, 4PT, 6-8 FT 32. P-4902` - LOCKBAR INACTI -, 6'8 Fr 33 P-4903 HANDLE SET, ACTIVE 34 P-4905 HANDLE SET, INACTIVE 35 P-4913 WSTP, .50X.50 FOLDED BULB SEAL DOOR 36 P-4917 CAP, ASTRAGAL, OUTSIDE NYLON 37 P4918 GUIDE, FLUSH B LT, INACTIVE PNL 38 P4922 COVER INTERIOR FLUSH BOLT NYLON LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez TtcTd Camden, TN 38320 PH. 941-380-1574 39 P4925 . CAP, ASTRAGALi INSIDE NYLON 40 P4926 SHIM, SIDELITE, DOOR SHIPPING BLOCK NYLON 41 P4927 GUIDE, FLUSH BOLT NYLON 42 P4930 SCREW, #10 X 1,1/4" HEX HEAD TEK SIDELITE ATTACH 43 P-4933 NUT, 3/8"-16 FLAI'1GED W/ SERRATED LIP, SS, PANEL SHEET DESCRIPTION: BOM 44 P4934 SCREW, #12-24 )C 1!2", PH FLAT, MS, HINGE 45 P-4936 DOOR KNOB, ACTIVE PANEL 46 1 P4937 DEADBOLT, ACTIVE PANEL DRAWN BY: ADE DATE: 09/08/11 47 P4969 SCREW, #10 X 2," REINF. ATTACH. 48 P-4997 STRIKE, DEADBOLT 49 P-5127 SCREW, #12 X 2", PH PAN, SMS, ANCHOR DWG #: CWS 641 REV.: D 50 P-5130 GASKET, DOORSILL, FRONT FOAM SCALE: 1:1 SHEET 8 OF 12 �49/16'� 1 1 7/16"qvcni: Ll— — 1/16' DOOR HEAD-1833 5 4 9/16' 1 1/16' a � 6 L 1/16' DOOR SILL-1878 PVC DOOR PANEL - 6083 4 9/16" � I�-1 1 /2" � d 7 F-1 5 1 9/16" 1/16" 215/16" 1116' DOOR JAMB-1880 2 SIDELITE-1881 4 9/16'F — � 9 21/16" L 1/16" SIDELITE-19u000 NOTE: ALL EXTRUSIONS ARE 6063-'r6 ALUMINUM REINFORCEMENT -1861 M 4215/16'IFI 1/16" REIN FORCEMENT-1860 �3"� 66 2" 1116° ASTRAGAL COVER-1859 4 4 REINFORCEMENT -1857 REINFORCEMENT -1858 76 2 15/16' 1/16" REINFORCEMENT -1862 1 3/4" 1 66 11I/8" 1/8° L INSERT, INACTIVE PNL-1849 27/16"--{ OCyCyN)(yl o. WINDOW SYSTEMS 59 1900 SW 44TH AVE. 1 3116" 1/16" 9 5. 64 OCALA, FLORIDA 34474 IL W W W.CW S.CC 6" THRESHOLD -1783 HEAD COVER - 1840 8700/10/50 PVC s/a SWING DOOR z va•—y " IMPACT 1/4" 61 3/81960 I� ¢ QZQ I 1/16" FILLER -1784 Z w W o a Z w 89 FRAME COVER - 1806 I O : Q U) 0 R 3: m 5I8" Z ZQZW00 j� 2 3/8" --{ O O F- O a- U U-_;Za-F-:)CO i1/16" 3 Z pO=�jZZ)U- T— 62 Q F--LL�oOLLZ >- <3Q:ow--F_O- PVC GLAZING BEAD - 6084 9 C, K F}- } ( � O_ SIDELITE COVER -1816 w L W U) 0 w cn w a U)F- w =~2 'a'�3w`) 1 1a F- a a 1 15/16" 63 5/8" 3/4" J— -1— 69 ;illw \� JCp.SA.TT14% //���/ DRIP CAP - 1817 1/16" BASE SWEEP- 1915 ` NO: 58201 ok 3/4" STATE OF !? 6s 13/16 " 13/16" 1/16" DRIP COVER- 1916 INSERT, BACK -1865 08/06/2020 9l16'� T 67 11/16" T 1/16" INSERT, FRONT -1864 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 EXTRUSIONS ADE I 09/08/11 CWS-641 D 'ALE: SHEET 1:2 9 OF 12 ru ANCHOR @ MIDSPAN YP.) 4" (TYP.) 6' MAX (TYP.) r r4 (TYP.) 6" MAX. (TYP.) I I " 2" (TYP.) "WOOD/METAL 17" MAX. O.C. (TYP.) --SEE NOTE 2 INSTALLATION ANCHOR (TYP.) .11 Ilr V11. SIDELITE DOOR . SIDELITE ANCHOR LAYOUT - (FLANGE) ANCHOR @ MIDSPAN (TYP.) 6" MAX. (TYP.) 6" MAX. (TYP.) 17" MAX — O.C. (TYP) 4" (TYP.) 4' (TYP � A 2' (TYP)'WqI O X I X I O U U V SIDELITE DOOR DOOR SIDELITE ANCHOR LAYOUT - (FLANGE) " CIRCLED ANCHOR LOCATIONS REQ'D ONLY IN WOOD AND METAL INSTALLATIONS. DO NOT INSTALL THESE ANCHORS INTO MASONRY. NOTES: - 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD. V- ('1(YALCYII//U 800 WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CW S.CC ID/METAL . 8700/10/50 PVC --SEE NOTE 2 SWING DOOR IMPACT +—INSTALLATION a Z z 3 ¢Zo w J p ¢ Z w ANCHOR (TYP.) 0 F W? O R� FRy- � z �a E U =O�0OO F—O UcoHZ F-3Q0 Q- ZpZ'w_ZUw UC/1Z= ¢O h-LLnO0N"Z W ponD co �mwW OJnr Kim of F~� K3wd `X%\Cl1iI11IJ//aD_• No. 58201 ` )v� Des �TATEOF 2�. �40RAt. f@l���• I) IIWO 2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 08/O6/2020 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 11. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT jNITH PRESSURE TREATED WOOD LUCAS A. TURNER, P.E. FL PE # 58201 MUST BE PROTECTED TO PREVENT REACTION. 2428 Old Natchez Trc Trl 5. INSTALLATION ANCHORS SHALT. BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES VYITH STF:ENGTHS LESS THAN THE I Camden, TN 38320 PH. 941574 MINIMUM SPECIFIED IN TABLE 1, SHEET 11. SHEET DESCRIPTION:TION: I 6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE. ANCHOR SCHEDULE ANC INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. + NOTES INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. DRAWN BY: ADE DATE: 09/08/11 7. A MINIMUM CENTER -TO -CENTER ;;PACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 4" FOR MASONRY, 2-3/16" FOR HINGES (ALL SUBSTRATES), 1" FOR WOOD AND METAL. 8. WOOD OR MASONRY OPENINGS, �UCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOAD$ TO THE STRUCTURE. DWG #: REV.: SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 11. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-641 D AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE bOCUMENTS: SCALE: SHEET 9. SEALING FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMAIWDMA 250(BOX WINDOWS), FMA/AAMAANDMA 300(E)CTERIOR DOORS) 1:8 10 OF 12 - TYPICAL HEAD ANCH�`O-RAGE .I SUBSTRATE BY OTHERS SEE TABLE 1 PERIMETER SEALANT------' G" �� _ jf� BY INSTALLER ILAL INSIDE AND OUT CONTINOUS DBL 114" BEADS OF SEALANT AROUND PERIMETER AT ALL INDICATED POINTS BETWEEN FRAME AND SUBSTRATE BY INSTALLER. PERIMETER SEALANT — BYINSTALLER INSIDE AND OUT SUBSTRATE BY OTHERS SEE TABLE 1 A VERTICAL SECTION 11 TYPICAL SILL ANCHORAGE —MIN. EDGE DIST. INTERIOR SEE TABLE 1 CONTINOUS DBL 1/4" BEADS OF SEALANT AROUND PERIMETER AT ALL INDICATED MIN. EMBEDMENT POINTS BETWEEN FRAME AND SUBSTRATE SEE TABLE 1 BY INSTALLER. J� INSTALLATION ANCHOR SEE TABLE 1 —1/4" MAX SHIM INTERIOR INSTALLATION ANCHOR SEE TABLE 1 MIN. EMBEDP SEE TABLE 1 MIN. EDGE DIST. SEE TABLE 1 TABLE 1: APPROVED INSTALLATION FASTENERS SUBSTRATETYPE ANCHORTYPE MIN. EMBEDMENT MIN. EDGE DIST. CONCRETE (2.85 KSI MIN.) 114" ELCO ULTRACON 1-3/4" 2-1/2" HOLLOW OR GROUT -FILLED CMU (ASTM C-90) 1/4" ELCO ULTRACON 1-1/4" 2-112" 2XMIN. SOUTHERN PINE (G=0.55) 1/4" ELCO ULTRACON 1-318" 7/8" 2XMIN. SOUTHERN PINE (G=0.55) #12 WOOD SCREW 1-3/8" 7/8" 16 GAUGE (0.060') MIN. #12-14 HILTI KW IK-FLEX OR ITW FULL THREAD 1/2" STEEL STUD (33 KSI YIELD MIN) TEKS SELF -DRILLING SCREW THRU 0.060" 1/8" ALUM. (6063-T5 MIN.) OR #12 GRADE 5 SELF -TAPPING ! FULL THREAD 1/2„ 1/8" STEEL (33 KSI.MIN.) DRILLING SCREW THRU 0.125" HINGE ANCHORS INTO CONCRETE (2M.{�5 KSI MIN.) 3116" ELCO ULTRACON 1-3/4" 2-1/2" HINGE ANCHORS INTO HOLLOW OR C3ROUT-FILLED 3116" ELCO ULTRACON 1-1/4" 2-1/2" CMU (ASTM C-90) HINGE ANCHORS INTO 2XMIN. SOUTHERN #10WOOD SCREW 1-3/8" 7/8" PINE (G=0.55) HINGE ANCHORS INTO 16 GAUGE (0.060") MIN. #10-16 HILTI KWIK-FLEXOR ITW FULL THREAD 1/2" STEEL STUD (33 KSI YIELD MIN) TEKS SELF -DRILLING SCREW THRU 0.060" HINGE ANCHORS 1/8" ALUM. (6063-T5 MIN.) OR #10 GRADE 5 SELF -TAPPING / FULL THREAD 1/2„ 1/8" STEEL (33 KSI MIN.) DRILLING SCREW THRU 0.125' 1/4' MAX. SHIM ������✓� MIN. EMBEDMENT WINDOW SYSTEMS SEE TABLE 1 1900 SW 44TH AVE. FLORIDA 34474 WWW.CWS.CC WWW. MIN. IEDGE DIST. SEE TABLE 1 8700/10/50 PVC { SWING DOOR . IMPACT r/ HINGEANCHOR SEE TABLE 1 HINGE MIN EDGE DIST. / SEE TABLE 1 � 1 PERIMETER SEALANT BY INSTALLER INSIDE AND OUT — HINGE MIN. EMBEDMENT SEE TABLE 'I SUBSTRATE BY OTHERS SEE TABLE 1 �B� HORIZO< TAL SECTION 11 TYPICAL JAMB / HINGE ANCHORAGE 213/16" 81/2' (TYP.) ANCHORS THRU HINGE (TYP.) c I 215/16 MAX. SEE NOTE NOTE: HINGE SPACINGS ARE: 8-1/2" FROM ENDS 21-5/16" MAX. O.C. FOR UP TO 81" UNIT HEIGHT. 20" MAX. O.C. FOR OVER 81"UNIT HEIGHT. HINGE hA'j OUT 1 i �0 Q Z 3: ¢Z�: Z w J o a w 0 w OZ o zPw§>_0W�m u. wzF�gx z Zx2¢Wwp0 O 0h0 Q=�_W U U(,I-ZrLFU)D- 0_ Z ZQ-(qZujZjU-. 2 :ow-mo- 00>_�S 9.' Lu L � U) 0 J fn W a rn F- w _~� W�wm a F- a w a 111A.17U //7//� No.58201* STATE OFV. 08/06/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 AEET DESCRIPTION: INSTALLATION DETAILS DOOR RAWN BY: DATE: AIDE 09/08/11 NG #: REV.: CWS-641 D 'ALE: SHEET 1:2 11 OF 12 TYPICAL HEAD ANCHORAGE SUBSTRATE BY OTHERS SEE TABLE 1, SHT 11 PERIMETER SEALANT BY INSTALLER IIIu S� INSIDE AND OUT CONTINOUS DBL 1/4' BEADS OF SEALANT AROUND PERIMETER AT ALL INDICATED POINTS BETWEEN FRAME AND SUBSTRATE BY INSTALLER. PERIMETER SEALANT BYINSTALLER INSIDE AND OUT SUBSTRATE BY OTHERS SEE TABLE 1, SHT 11 ►� MIN. EDGE DIST. SEE TABLE_1, SHT 11 MIN. EMBEDMENT SEE TABLE 1, SHT 11 L114" MAX. SHIM INTERIOR INSTALLATION ANCHOR SEE TABLE 1,.SHT 11 INTERIOR CONTINOUS DBL 1/4" BEADS OF SEALANT AROUND PERIMETER AT ALL INDICATED POINTS BETWEEN FRAME AND SUBSTRATE BY INSTALLER. INSTALLATION ANCHOR — SEE TABLE 1, SHT 11 1/4" MAX. SHIM (LIM10bVIN-L,,/,�t1�L II I�II�/ MIN..EMBEDMENT WINDOW SYSTEMS SEE TABLE 1, SHT 11 1900 SW 44TH AVE. ---I OCAL'A,FLORIDA 34474 / www.cws.cc MIN. EDGE DIST. SEE TABLE 1, SHT 11 8700/10/50 PVC SWING DOOR IMPACT PERIMETER SEALANT BY INSTALLER t INSIDE AND OUT SUBSTRATE BY OTHERS SEE TABLE 1, SHT 11 i D HORIZONTAL SECTION 12 TYPICAL JAMB ANCHORAGE MIN. EMBEDMENT „ SEE TABLE 1, SHT 11 j MIN. EDGE DIST. SEE TABLE 1, SHT 11 C VERTICALSECTION _______ ___-------------- 12 TYPICAL SILL ANCHORAGE 0wo aWow Zoz Of I-w Zr�igi zx1iaa!W00 OHO a=FD: UUHZa FOa z -ZI-0m O Z O W Z j O U ~— LL2 0 0 O z 2 F-I-FZ_ of 00�Ca0WrnW _ ~� w=wai 4 ��a \�J�pSA TyRg"� No. 58201*'- * 4f STATE OF .� 08/06/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez.Trc Trl Camden, TN 38320 PH. 941-380-1574 SHEET DESCRIPTION: INSTALLATION DETAILS SIDELITE DRAWN BY: DATE:. AIDE 09/08/11 DWG #: REV.: CWS-641 D SCALE: SHEET 1:2 12 OF 12