HomeMy WebLinkAboutReview- CommentsREVIEW COMMENTS
1
PROPERTY INFORMATION
Address: 5502 Wintergarden Pkwy Owner(s):
Ghazanfar Saeed / Mohammad Afzal
City / State / Zip: Fort Pierce, FI 34951
Parcel #: 1301-614-0080-000/6 Jurisdiction: SAINT LUCIE COUNTY
Zoning: RS-4 Lot#: 20 Block: 159
APPLICATION INFORMATION
Permit Number:
2201-0255 Stories:
Permit Type:
BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS)
CONTRACTOR INFORMATION
Contractor Name:
Roderick J Waller
Business Name:
Sunrise City Concrete Services Inc.
Business Addr:
130 S Indian River Drive Suite 202
City / State / Zip:
Fort Pierce, A 34950
REVIEWS AND COMMENTS
Review Type
Status Reviewed By
ADDRESSING ASSIGNMENT
COMPLETE Angela Vassar.
Comment:
DOCUMENTS MISSING
PENDING Deanna Givens
1/12/2022
Comment: HARDCOPY
1/12/2022
Comment: NEED VEG REMOVAL. APPLICATION
1/12/2022
Comment: FILLED LANDS AFFIDAVIT
1/12/2022
Comment: ELECTRICAL SUB AGREEMENT
1/1212022
Comment: PLUMBING SUB AGREEMENT
1/12/2022
Comment: HVAC SUB AGREEMENT
1/12/2022
Comment: ROOFING SUB SGREEMENT
ENVIRONMENTAL REVIEW PENDING
Comment:
FRONT COUNTER REVIEW COMPLETE Deanna Givens
Comment:
NOTIFIED FOR PICK UP
PENDING
Comment:
Automatic Sprinkler System? No
Fax Number: 772-907-0420
Email: Rodwallerl@Gmail.Com
Date Started Date Completed Date Released
1131 /2022 1131 /2022
1/12/2022
1/12/2022 1/12/2022 1/.12/2022
`ontsera�aRs { REVIEW COMMENTS
�I� �"C�Rtlon_t�vislon
2900Vf��Awnu
Page 2
PLANS EXAMINER REVIEW
INCOMPLETE Peter Swarr 2/3/2022
Comment:
DRAWINGS CALL OUT 1/2 INCH CDX PLYWOOD, FBC REQUIRES 5/8" FBC R803.1. ALSO 15/32" CALLED
OUT TO BE USED FOR THE APPROVED UNDERLAYMENT. REVISE, CLOUD, AND RE -SUBMIT. IT SHOULD
2/3/2022
BE NOTED THAT 5/8" AND 3/4" SHEATHING ARE ALSO CALLED OUT IN THE NOTES. REVISE, CLOUD, AND
RE -SUBMIT
Comment:
METAL ROOF CALLED OUT ON DETAILS AND ASPHALT SHINGLES CALLED OUT ON PRODUCT APPROVAL.
2/3/2022
REVISE, CLOUD, AND RE -SUBMIT
Comment:
SMOKE DETECTORS NOT SHOWN INSIDE OR OUTSIDE OF MASTER BEDROOM DOOR AND OTHER
2/3/2022
SMOKE/CO2 DETECTORS ARE INDICATED WITH REVERSED LETTERS AS ARE OTHER ITEMS ON THE
ELECTRICAL PLAN S-2. REVISE, CLOUD, AND RE -SUBMIT
Comment:
SMOKE DETECTORS ARE CALLED TO ONLY BE INTERCONNECTED IN MULTI STORY BUILDINGS, PG S4.
2/3/2022
HOWEVER, ALL SMOKE DETECTORS ARE TO BE INTERCONNECTED. INSTALL PER FBC R314.4. REVISE,
CLOUD, AND RE -SUBMIT
Comment:
PLEASE REVIEW THE TRUSS DRAWINGS AGAINST THE TRUSS LOCATION PLAN AND VERIFY THAT THE
2/3/2022
TRUSSES DESIGNS GO WITH THE SUBMITTED TRUSS LAYOUT DRAWING. REVISE, CLOUD, AND RE-
SUBMIT.
Comment:
NO DETAIL ON HOW TO CONNECT THE BEARING WOOD FRAMED WALL TO THE BLOCK WALL. REVISE,
2/3/2022
CLOUD, AND RE -SUBMIT
ZONING REVIEW
INCOMPLETE Angela Vassar 1/31/2022
Comment:
SOME MEASUREMENTS ARE MISSING ON THE SURVEY. PLEASE SUBMIT TWO SEALED SURVEYS
1/31/2022
SHOWING ALL MEASUREMENTS OF PROPOSED HOUSE, ENTRY AND PORCH ARE ON THE SURVEY.
1/31/2022 Comment:
PLEASE SUBMIT SEPTIC AND WELL PERMITS.
1/31/2022 Comment:
THE PLAN REVIEWER MAY HAVE ADDITIONAL COMMENTS.