Force Engineering & Testing Inc.
r19530 Ramblewood Drive
Humble,TX 77335
Product Evaluation Report
ATLANTIC METAL Il OF VERO BEACH, INC.
26 Ga. 5V Crimp Roof Panel over Plywood
Florida Product Approval # 17796.6
Florida Building Code 2014
Per Rule 61G20-3
Method: 1—D
Category: Roofing
Subcategory: Metal Roofing
Compliance Method: 61G20-3.005(1)(d)
HVHZ
Product Manufacturer:
Atlantic Metal II of Vero Beach, Inc.
4020 43`d Avenue
Vero Beach, Florida 32960
Engineer Evaluator:
Terrence E. Wolfe, P.E. # 44923
Florida Evaluation ANE ID: 1920
Validator:
Locke Bowden, P.E., FL #49704
9450 Alysbury Place
Montgomery, AL 36117
Contents:
Evaluation Report Pages 1— 4
IIII�rj�,,
,�� N•C E. E• jj, �ii
O
C E N S
No. 449
.o' STATE of ; a
o _ R I ID
Stab it`s., ,.•� ��
FL# 17796.6 June 16, 2015
7::
Force Engineering & Testing Inc.
19530 Ramblewood Dxivc
Humble,TX 77338
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2014, Sections 1504.3.2, 1518.9, 1523.6.5.2.4.
Product Description: 5V Crimp Roof Panel, 26 Ga. Steel, 24" Coverage, through fastened roof panel
over APA Plywood decking. Non -Structural Application.
Panel Material/Standards: Material: 26 Ga. Steel, ASTM A792 coated with Fluropon or ASTM A653 G90
conforming to Florida Building Code 2014 Section 1507.4.3.
Yield Strength: Min. 50.0 ksi
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2014, Section 1507.4.3
Panel Dimension(s): Thickness: 0.018" min.
Width: 24" Coverage
Rib Height: 3/8" major rib
Panel Rollformer: Rollformer Corp.
Panel Fastener: #9-15 x 1-1/2" WoodZac w/ Zac Head with sealing washing through panel rib.
Y4" minimum penetration through plywood
Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1517.6
Substrate Description: 1) For HVHZ construction, use 19/32" or greater APA Rated plywood or wood
plank. In reroofing applications where the deck is less than 19/32" thick (min.
15/32") the attachment of the decking in no case shall be less than 8D annual
ring shank nails at 6" O.C. Design of plywood and plywood supports are outside
the scope of this evaluation. Substrate must be designed in accordance w/
Florida Building Code 2014.
2) For Non-HVHZ applications, use min. 15/32" thick, APA Rated plywood over
supports at maximum 24" O.C. Design of plywood and plywood supports are
outside the scope of this evaluation. Substrate must be designed in accordance
w/ Florida Building Code 2014.
A. E N.0 E, E• yr, i�i
O
C E N S F •�',�ii
STATE OF ;
is
'0 W . FL O R I ID
CAA �� S
FL# 17796.E
June 16, 2015
F
Design Uplift Pressures:
Code Compliance:
Evaluation Report Scope:
rForcegineering & Testing Inc.
19530 Ramblewood Drive
Humble,TX 77338
Table"A"2"'—` I-Z -Z—VNIF 7
Maximum Total Uplift Design Pressure:
, 108.5 ps g
IF156P5"ps
Fastener Pattern:
Panel' 'b
Panel R b
Fastener Spacing:12'
*Design Pressure includes a Safety Factor = 2.0.
The product described herein has demonstrated compliance with
The Florida Building Code 2014, Section 1504.3.2, 1518.9, 1523.6.5.2.4.
The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2014, as relates to Rule 61G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
■ TAS 125-03
■ UL 580-06 - Test for Uplift Resistance of Roof Assemblies
■ UL 1897-04 - Uplift Test for Roof Covering Systems
■ TAS 100-95 - Test Procedure for Wind and Wind Driven Rain Resistance
of Discontinuous Roof Systems '
■ TAS 110-00 - Accel. Weathering ASTM G 155 / Salt Spray ASTM B 117
Reference Data: 1. TAS 125-03: UL 580-94 / 1897-98 Uplift Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 115-0172T-07A-C*
2. TAS 100-95
Farabaugh Engineering & Testing, Inc. (FBC Organization # TST-1654)
Report No. T130-07
Report No. T215-08
3. TAS 110-00: Valspar Fluropon coated metal panel testing
A) ASTM G 155 by PRI Asphalt Technologies dated 10/31/2012
B) ASTM B 117 by PRI Asphalt Technologies dated 10/31/2012
4. Certificate of Independence
By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc.
(FBC Organization # ANE ID: 1920)
Uff
FIL,F C^P
-9 R ww- L
,ON r
No.444
Li
•a ' STATE OF ; a Z
Fiat`• LORI1)p'• �'���
FL# 17796.6 June 16, 2015
Force Engineering & Testing Inc.
19530 Ramblewood Drive
Hunible,TX 77338
Test Standard Equivalency: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Minimum Slope Range:
2:12. Minimum Slope shall comply with Florida Building Code 2014, including
Section 1515.2.2 and in accordance with Manufacturers recommendations. For
slopes less than 3:12, lap sealant must be used in the panel side laps.
installation:
Install per manufacturer's recommended details and RAS 133.
Underlayment:
Per Manufacturer's installation guidelines per Florida Building Code 2014 Section
1518.2, 1518.3, 1518.4.
Fire Barrier:
%" Georgia Pacific "Dens Deck" or approved equal.
Shear Diaphragm:
Shear diaphragm values are outside the scope of this report.
Design Procedure:
Based on the dimensions of the structure, appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2014 for roof cladding
wind loads. These component wind loads for roof cladding are compared to the
allowable pressure listed above. The design professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover. Support framing must be in compliance with Florida Building Code 2014
Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading.
* Test Reports are owned by Coastal Metal Roofing, Inc. Coastal Metal Roofing, Inc. gives the above manufacturer
permission to use these test reports.
,.j.tttwrrlt�t��i
D
CENS�<'t'�ri
No. 444n_
STATE OF ; a
psi ,�f� r�o+�trryti11 ♦V,��
FI# 17796.6 June 16, 2015
5-V CRIMP EXPOSED FASTENER SYSTEM
5V CRIMP PANEL WATERPROOF
MEMBRANE
FASTENER#9 L SUBSTRUCTURE
12" Q.C. MAIN FIELD
6" O.C. PERIMETER
MATERIAL OMONS
FINISH OPMONS
ASTN A 6S3 G-9R
- -
ASTH A 792
FA13RICA17ON OMIONS
STEEL 26
,
CUSIDti CQL+>�s
•TECHNICALOATR
WE CAN PRCIVtDE FULL Ctisro t Cm-w SERVtCES
TQ MT04 PRACTICALLY ANY HATEPIALI SHADE,
-
DR rmr , yUj REGUM,
{�wr ES-78x I-1/2'W000ZAC
,,,, / z PT e- 4 c-,t o
It,4111111:r "I
of Fiorliis �� . •0 E N
rp
t
02FM
NO-449
-t3 ; S r ROLL FORMER CC3RF.
• • Usti HO INDEPENDENCE LABS
• CHAI.50W, ?A 18914
OR 1
5
V
ONAL �N�.,.
June 16, 2015
27--1/2"' Flat 'Stock Matoriat For 24' Cover,acg2
Note _ Alt Radii 0.05
12 Na V 9-9
For 2�d Coverage
24 Coverage --�
7/1S"
1-5f 8;
Fixed
Qvertap Ribs
7/8;`
3/8'
Ad ju5tabt e
Center Rib
px
2 --
lid jus ta.ote
Underlao nibs
-<.--.,v�ran-�nac_�vtrc,�-,�wr�� eua�s-}rannc-w-suosuaie-r-v-crown-arum-wuc�rtreage•orrzng�uttmarra•spa�-i •v-•tv:e:•
5V CRIMP PANEL
OUTSIDE
CLOSURE��;'_`
WATERPROOF
MEMBRANE
FLASH
TYPICAL DETAILS
RIDGE
RIDGE
FLASH FASTENER #9
TRI-BEAD
TAPE SEALER
4`yjGYEf3f:3
�, . • 0 -.
-T;
FASTENER #9 <C/�•' V` S.<` • ` ' „
SUBSTRUCTURE =_ ri o ..4 4 S 2 a
CRQSS'SECTION OF -
State of Florida �• • ":�--.:� n
RIDGE OVER WOOD, -DECK ao a STA
a 4 ..
OR O) G` �9
FASTENER *9 �t� ,ONAi..
June 16, 2015
a
OUTSIDE
CLOSURE
�- TRI-SEAD
TAPE SEALER
WATERPROOF
MEti{BRANE
FOLL SHk61' '9 XWd
5V CRIMP PANEL t
SUSSTfMUCTURS
ISOMETRIC VIEW OF
RIDGE OVER'WOOD DECK
NOTES:
I- Stop panels 2• from center line of ridge.
2. Install first raw of fasteners across panel to substrate 1'-0' down from bottom edge of ridge trim and space i `-0" G.C.
1/8"x1" CONT,
BUTYL TAPE
�dti�sas7tt�
.•i NCE E. °°o
40
8=9 of Florida ; Q • • •� G E N S�,'
Q
# 2SM
s No.4492
o
j
30# FELT O;RI�P.\��,
FULL SHEET IN VALLEY • • • •
NA -
June 16, 2015
9-15 x 1 1/2 HVM W/WASHER
[6 PER PANEL)
15/32" PLYWOOD SHEATHING [BY OTHERS]
INSIDE CLOSURE
STRIP W/ URETHANE
SEALANT
VALLEY FLASHING
[VALLEY ENDLAP 4" MIN.)
24" O.C.
NOMINAL COVERAGE
FASTENER PATTERN AT VALLEY
5-V CRIMP PANEL
14-12 x 1 PANCAKE HEAD
SELF -TAPPER [12- 0_C]
9--15 x 1 1/° Llllu 11 /.rnnnr, r
WASHER [12"
BUTY
5—V CRIMP PANE
15/32' PLYWOOD SHEATHING
[BY OTHERS]
State at Florida
C.O.A.
� zarTa
`i��itic:::�ra+r
.•GE E.
,,{{ ��11 r� a p
• y, • N0.44923 . r
n Jl • � �
•
. d
., oNAAX-
+rrr•rrtis��
June 16, 2015
—'--I""-. dui vIn1=r-,,)J
RAKE FLASHING
,,---9-15 x 1 1/2 HWH W/NEOPRENE
WASHER [12" O.C.]
WOOD TRIM
[BY OTHERS]
ate Of t- odda
G.O.A.
ho.44923.
ST E L
June 16, 2015
SHT-5V 05
ID-12 x I PA1ICAKE
SELF-IAPPER LIr C
P.I.YV/OCD SHEATHING [NBCSI]
PLYWOOD S-HEATNINO [BY OTHERS]
Pr%EFINISHED WALL PANEL
[I3Y OTHMs3
PREFINISIED RAK: WAIL RA1gIgr
1/8"xi" CONT.
BUTYL Tk;?E
.,,—PREFINISHED 5—V
CRIMP PANEL
�-- 9- is s 11/2 H94 W/NEO R&IE
WAm [12- O.C]
ICE: & WATER SHIELC MIN.
CONTJNU E SUP { APL`C TROORECLET
30 !b Aaci`
10-12 v 9 DAKirlAVr- tir-An
SELF
5—V CRIMP PANEL
30# FELT -�
1 S/32" PLYWOOD SHEATHIN(
[BY OTHERS'
24" O.C.
NOMINAL COVERAGE
FASTENER PATTERN AT EAVE
mate of FWift
C.oJL1 ��°yBtL:SIICB_9
l
ONCE F.. �!
2b778 v° • ° • ° ° O
a
e Q- °° F_ r-1 s °•° �-r
�'•
HER
' �'
a No.44923 .. • e
" e STTE ,Q
STRIP
;O
OR
__THANE
ONAL
e
Q.Q.LGB -.
3"xl " CON T.
June 16, 2015
3UTYL TAPE
_ASHING
WALL PANEL FASTENER 0 12" O.C.
(BY OTHERS)
:L (BY OTHERS)