HomeMy WebLinkAboutLetter- Roof Specification AffidavitNHM/y(x��(y[� RK �"7,µIJ�`�,, 11�I�(\��I/W��((�Ij/ OF TILE THF.ASURE COASTIM 806 Delaware Ave. (772) 267-1399 Fort Pierce, FL 34950 benchmarkengineeringtc@gmail.com October 26, 2017 RE: Roofing Specification Affidavit: Annette Tedeso, Existing Residence 6772 Sinsonte Ct. Fort Pierce, FL 34951 Dear St. Lucie County Building Department: Please be advised, that the products and specifications are approved per Florida Building Code Compliance Acceptances, 2014 FBC and the product manufacturer's recommendations. Manufacturer: Profiles: Code: Wind Speed: Exposure: Mean Roof Height: Pitch: Design Pressure: Max uplift: Fasteners Gulf Coast Supply & Manufacturing 26 Ga. 5v Crimp: FL #11651.13 R2 FBC 2014, Section R 905.10 160 MPH Max Ultimate B <30' 2.5/12 Min. Zone 1: -38.2 Zone 2: -53.9 Zone 3: -101.4 -131.0 psf @ 9.5"-2"-9.5" & 16" O.C. #9-15x1.5" w/ sealing washers through rib w/ %" min. penetration through plywood Underlayment: Interwrap Inc. NOA# 13-0730.01, Titanium Ps.u-30, self -adhered, w/ 3" min. horizontal laps & 6" min. vertical -laps. First course shall be placed parallel to eave & field using heavy pressure roller. Roof Decking: Existing plywood sheathing shall be nailed w/ 8dx2" ring shank nails @ Zone 1: 6" O.C. throughout Zone 2: 4" O.C. perimeter & 6" O.C. field Zone 3: 4" O.C. throughout Thank you for your diligence and please feel free to contact me at (772) 267-1399 with any comments or concerns h l t iy�y may ay have. - y\\ t // / Sinc��l^�f'AUTC1,1, p, — -Cx W- • ddl.- Bowdoin P.E.