HomeMy WebLinkAboutRoofing Specification AffidavitOf' THE TREASURE (COAST LL C. 806 Delaware Ave. (772) 267-1399 Fort Pierce, FL 34950 benchmarkengineeringtc@gmail.com October 26, 2017 RE: Roofing Specification Affidavit: John Weeks, Existing Residence 122 Queen Fredericka Ct, Fort Pierce, 34949 Dear St. Lucie County Building Department: Please be advised, that the products and specifications are approved per Florida Building Code Compliance Acceptances, 2014 FBC and the product manufacturer's recommendations. Manufacturer: Gulf Coast Supply & Manufacturing Profiles: 26 Ga. 5v Crimp: FL #11651.13 R2 Code: FBC 2014, Section R 905.10 Wind Speed: 165 MPH Max Ultimate Exposure: D Mean Roof Height: <30' Pitch: 3/12 Min. Design Pressure: Zone 1: -49.2 Zone 2: -68.4 Zone 3: -130.8 Max uplift: -131.0 psf @ 9.5"-2"-9.5" & 16" O.C. Fasteners: #9-15x1.5" w/ sealing washers through rib w/ %" min. penetration through plywood Underlayment: Interwrap Inc. NOA# 13-0730.01, Titanium Psu-30, self -adhered, w/ 3" min. horizontal laps & 6" min. vertical laps. First course shall be placed parallel to eave & field using heavy pressure roller. Roof Decking: Existing plywood sheathing shall be nailed w/ 8dx2" ring shank nails @ Zone 1: 6" O.C. throughout Zone 2: 4" O.C. perimeter & 6" O.C. field Zone 3: 4" O.C. throughout Thank you for your diligence and please feel free to contact me at (772) 267-1399 with any comments or concerns that you may have. Si�L�r�eUYCH S0 No _ m I ..� 7 ' w ' ''U �E ,ZZ 1349 t I H , kjh'ion P.E.