HomeMy WebLinkAboutEngineeringHELIOCOL COLLECTOR - COI A®H�SIVE GENERAL NOTES: FE TILE - TILE 1. APPLICABLE CODE: 2014 FLORIDA BUILDING CODE (5-TH EDITION) & ASCt-/-IU MINIMUM Ut51GN LOADS FOR BUILDING AND OTHER STRUCTURES. 2. PLANS ARE IN ACCORDANCE WITH 2O14 F.B.C. (5TH EDITION) AND PER MIAMI DADE NOA 15-1201.04. 3. POLYPRO ROOF ADHESIVE SHALL BE APPLIED IN COMPLIANCE WITH THE COMPONENT APPLICATION SECTION AND THE CORRESPONDING PLACEMENT DETAILS NOTED IN THE NOA APPROVAL DOCUMENT AND THE 3M/POLYFOAM POLYPRO ROOF TILE ADHESIVE OPERATING INSTRUCTION AND MANUAL BOOKLET. 4. TILE ROOF INSTALLATION AND UNDERLAYMENT SHALL COMPLY WITH LATEST FLORIDA BUILDING CODE AND ROOFING APPLICATION STANDARD RAS 120. 5.3M/POLYFOAM POLYPRO ROOF ADHESIVE COMPLIES WITH THE FOLLOWING CODES: 2014 FLORIDA BUILDING CODE (5TH ED), SOUTH FLORIDA BUILDING CODE BROWARD COUNTY-1999, MIAMI DADE NOA 15-1201.04 r I nrATTnKi m MI I Frmoc Ulan w/cIni VLnAM AnNFCT\/F Tr, AInT TO RP TAICTAI I Fn TM IAITAIn 7nMF'A 7. CONNECTIONS AND SPECS PER THIS DRAWING MAY BE USED FOR ALL HELIOCOL COLLECTORS TO RESIST WIND LOADS AS OUTLINED IN 2014 FBC, CHAPTER 16 FOR UP TO 175 MPH, EXPOSURES "B" OR'C" WIND VELOCITY PER REQUIREMENTS STATED IN ASCE7-10. 3M/POLYFOAM POLYPRO -NOA SPECIFIC NOTES: POLYPRO ROOF TILE ADHESIVE MUST BE APPLIED TO AN UNDERLAYMENT INSTALLED IN COMPLIANCE WITH APPLICATION INSTRUCTIONS DETAILED IN THE FOLLOWING LATEST DOCUMENTS: FRSA/ROOF TILE INSTITUTE ADHESIVE SET TILE SPECIFICATION. 3M/POLYFOAM ADHESIVE IS UL CLASSIFIED AS AN ADHESIVE MIAMI-DADE NOA 15-1201.04, EXPIRES 1/03/2021. LIMITATIONS OF MIAMI-DADE NOA FOR SPECIFIED TILE PROFILE - ADHESIVE BELOW: 1) FOR ADHESIVE SET TILE APPLICATIONS, A STATIC FIELD UPLIFT TEST IN ACCORDANCE WITH TAS 106 MAY BE REQUIRED, REFER TO APPLICABLE BUILDING CODE. 2) APPLICANT SHALL RETAIN THE SERVICES FOR A MIAMI-DADE COUNTY CERTIFIED LABORATORY TO PERFORM QUARTERLY TEST IN ACCORDANCE WITH TAS 112, APPENDIX IN. SUCH TESTING SHALL BE SUBMITTED TO THE BUILDING CODE COMPLIANCE OFFICE FOR REVIEW. 3) MINIMUM UNDERLAYMENT SHALL BE IN COMPLIANCE WITH THE APPLICABLE ROOFING APPLICATIONS STANDARDS LISTED SECTION 4.1 HEREIN. 4) THIS ACCEPTANCE IS FOR WOOD DECK APPLICATIONS. MINIMUM DECK REQUIREMENTS SHALL BE IN COMPLIANCE WITH APPLICABLE BUILDING CODE. TABLE 1: ADHESIVE PLACEMENT FOR EACH GENERIC TILE PROFILE PER MIAMI DADE NOA 15-1201.04 CONCRETE ROOF TILE PROFILE PLACEMENT DETAIL MINIMUM SINGLE PADDY WEIGHT (GRAMS) FLAT / LOW / HIGH PROFILE #1 AND #2 12 HIGH PROFILE (2 PIECE BARREL) #2 12 FOR HIP AND GABLE ROOFS - PLAN 1"xq x2/-16-ALUM. 6063T6 Z-BAR SHAPE WITH (1)1" DIA. -1 4' LENGTH TAPCON STAGGERED AS SHOWN THIS SHEET HELIOCOL COLLECTOf TYP 111x l"x 2%"- 16 1i ALUM. 2 2 6063T6 Z-BAR SHAPE WITH (1) 1" DIA. -11" LENGTH TAPCON STAGGERED AS SHOWN THIS SHEET END CAP TYP. TYPICAL (5) COLLECTOR ARRAY PLAN SCALE: a"=1'-0" 1"x2'x2%"-16'ALUM. 6063T6 Z-BAR SHAPE TYP TOP & BOTTOM OF COLLECTOR WITH (1) 4' DIA. -14' LENGTH TAPCON STAGGERED 12" O.C. (SEE Z-BAR DETAIL) ** CLAMP CONNECTION NOTE: 1. WHEN CLAMP FALLS OVER TILE: USE (1) 4' DIA. -14' LENGTH TAPCON THRU Z-BAR INTO TILE. 2. WHEN CLAMP FALLS OVER VALLEY: USE (1) 4' DIA. - 1" LENGTH ST. STL. BOLT - WASHER- NUT THRU Z-BAR RECEIVED OCT 3 0 2017 Permitting Department St. Lucie County, FL 1" x 2' x 2 %" - ib' ALUM. 6063T6 Z-BAR SHAPE (30" MIN. SECTIONS) FASTENED WITH (1) 4" DIA. -14' LENGTH TAPCON 12" O.C. 1 22 � 31 2 ST LU L C DETAIL BUIL R I 0 I�0R COMPL,IA REVIEWOD 0_v DATE _����//. PLANS AND PF.R 1NIi' MUST ME KSPT ON J00 OR mo INSPROTION %NILL_R9 MAPP 1710 1"x2"x2%"-16"ALUM. - 6063T6 Z-BAR SHAPE TYP. (2) #6 HEX SCREWS - 4' LENGTH TYP HELIOCOL CLAMP - _ CLAMP SPACED 2'-0" O.C. CONNECTION - TYP. SEE NOTE ** 4' DIA. -14LENGTH - TAPCON STAGGERED 12" O.C. TYP. HIGH CONC. TILE TYP. -- -APPLY 3M/POLYPRO ROOF TILE APPLY 3M/POLYPRO ROOF TILE - #2S.Y.P. ADHESIVE, OR EQUAL, TO ADHERE #2 S.Y.P. ADHESIVE, OR EQUAL, TO ADHERE WOOD ROOF BOTTOM SIDE OF TILE HELIOCOL WOOD ROOF BOTTOM SIDE OF TILE HELIOCOL TRUSS TYP. CLAMP IS ABOVE TO PLUS ALL TRUSS TYP. CLAMP IS ABOVE TO PLUS ALL WOODD TILES AROUND IT (5 MIN.) _ _ _ —WOOD- - -TILES AROUND IT (5 MIN.) _ -SHEATHING - - - SHEATHING TYPICAL Z-BAR - HELI TYPICAL FLAT / LOW PROFILE CONCRETE TILE ADHESIVE TOP & BOTTOM CONNECTION DETAIL SCALE: 1"=V-0" 1"x2'x2%"-1fi'ALUM. 6063T6 Z-BAR SHAPE TYP TOP & BOTTOM OF COLLECTOR WITH (1) 4" DIA. -11" ,LENGTH TAPCON 'STAGGERED 12" O.C. (SEE Z-BAR DETAIL) Mid 04, U z 0 0 Ckf (D ���N TYPICAL HIGH PROFILE CONCRETE TILE CLAMP CONNECTION ADHESIVE TOP & BOTTOM CONNECTION DETAIL%4� DETAIL I SCALE: 1"=1'-0" SCALE: 1/2"= V-0" m Y it 0 PROJECT: Lw z Uz a2i U O F- _F- Ln J �u ~ 00 w L� Ln N� I w w N J J 0 o L a U U Jib nz�o0 w O w C C =Uoaa DATE 7-1947 DRAWN BY: JAT CHKD BY: JAT REC. N0. # 29127 SCALE I AS NOTED _H Coe •GENSF SHEET 1 OF I'. No 80379 It AW\� LL0o . t_ o� as$ JUL 19 2017