Loading...
HomeMy WebLinkAboutMobile Home Aluminum Roof Plant2 .024 ALUM F 2'RIDGED POLYSTYRENE INSULATION EXISTING MOBILE HOME ROOF-7 2X3 P.T. Wlj/��/@ 9. 0. -'INTO EXISTING COACH FRAMI EXISTING COACH FRAME EXTRUDED ALUM. ATTACH RAIL wf #8Xl TA S.M.S. 3' O.C. r- UTYL RUBBER SEAL /-..024 ALUM FLASHING BUTYL RUBBER SEAL /-EXTRUDED ALUM. ATTACH RAIL wl #8X1114 S.M.S. 3' O.C. 024 ALUM ROOF IN ULATION 4 ALUM F 2' RIDGED POLYSTYR_._ _ _ULATION / EXISTING PATIO ROOF" 2X3 P.T. w#03' W.S. @ 6' 0. 2X3 P.T. BLOCKS CUT TO FIT II PANS w/ (2) #8 S.M.S. PER PAN EXTRUDED ALUM. ATTACH RAIL wl #8X1 114 S.M.S. 3' O.C. /--CUTYL RUBBER SEAL 024 ALUM FLASHING INTO PAN AND CAULK OR CONTINUE FLASHING TO GUTTER 248 SMS w/ NEOPRENE WASHERS TO TOP OF EACH PAN aW OVERHANG POLYSTYRENE FOAM INSERT EACH PAN .024 IOOF CONT. OVER FASCIA EDGE DETAIL OR RM =- -- - tACTORY SEAMS @ 48' O.C. GUTTER EDGE DETAIL ____________________________ INSULATION EXISTING MOBILEHOMEROOF SINGLE WIDE (NTS) —� EXISTING PATIO ROOF COL 6 BEAM EXISTING WALL CHANNEL .024 ALUM RO( ALTERNATE COACH & PATIO ROOF ATTACHMENT #1 ALTERNATE PATIO PAN ROOF ATTACHMENT DETAIL "A" 2-RIDGED POLYSTYRENE INSULATION - CONNECTION DETAIL NTS EXISTING MOBILE HOME ROOF (NTS) (NO 41h WALL) N.T.S. EXTRUDED ALUM. ATTACH RAIL r .024ALUM ROOF wl#BX1114S.M.S.3'O.C. 30# FELT ON TOP OF BUTYL RUBBER SEAL .024 ALUM ROOF PANS 1 !� 2' RIDGED POLYSTYRENE INSULATION 024 ALUM FLASHING INTO PAN AND CAULK OR CONTINUE EXISTING MOBILE HOME ROOF EXTRUDED ALUM. ATTACH RAIL , , r FLASHING TO GUTTER 2X3 P.T. W/ #8X3' W.S. ® 6' O.C. wl #8X1 1/4 S.M.S. W O.C. ;, �= �= , _ INTO EXISTING COACH FRAME i r BUTYL RUBBER SEAL `,� T �. 2-#8SMSw/NEOPRENE WASHERS TO TOP OF EACH PAN .024 ALUM ROOF FLASHING EXTRUDED ALUM. CH RAIL wl #8Xl 114 S.M.S. 3'O.C. 2X3 P.T. WI #8X3' W.S. @ 6' O.C. - RUBBER SEAL INTO EXISTING kOF F�/�BUM/ 024 ALUM ROOF 30# FELT ON TOP OF PANS 2X3 P.T. BLOCKS CUT TO FIT II PANS wl (2) 98 S.M.S. PER PAN _EXISTING PANS wl EXISTING COACH _Wdl � INSULATION INSERTS FRAME EXISTING ALUM. COL & BEAM ALTERNATE COACH & PATIO ROOF ATTACHMENT #2 CONNECTION DETAIL (NTS) (w/4fh WALL) .024 ALUM 2' RIDGED POLYSTYRENE INSULATION EXTRUDED ALUM. ATTACH RAIL wl #8X11/4 S.M.S. 3' O.C. BUTYL RUBBER SEAL r.024 ALUM ROOF FRAME v r v '��� I `EXISTING PATIO ROOF MAX SPAN 14'-0' —TAPERED INSULATION AS REQUIRED EXISTING WALL CHANNEL EXISTING PANS wl --J INSULATION INSERTS 2X3 P.T. BLOCKS CUT TO FIT II PANS wl (2) #8 S.M.S. PER PAN TYPICAL_ROOF SECTION N.T.S. EXTRUDED ALUM. ATTACH RAIL wl #8X1 114 S.M.S. 3' O.C. �BUTYL RUBBERSEAL I #84W STAINLESS STEEL HEX HEAD FROM ATTACHMENT RAIL TO EXISTING MOBILE HOME FRAME Q 5' O.C. MIN, INTO EXISTING FRAMING 11B5:1' WIDE BUTYL RUBBER CONT.-1.1 .024 ROLL ALUMINUM INSULATION ATTACH CONT. 2514' P.T. TO EXISTING MOBILE HOME FRAMING W/#80 WOOD SCREWS @ SPACING TO STRAIGHTEN WOOD ONLY, IN LIEU OF FULL FRAMING .024 ALUM GUTTER ATTACHMENT PER DETAILS WI STRAPS Q 4'-0 O.C. COACH AND PATIO ROOF O 40 CONNECTION DETAILS FOAM INSULATION ®� .024ALUM ROOF 0/ >, c- -__----��•\ :cs co _/ PATIO PAN ROOF ATTACHMENT DETAILS w m �EA1_ ATTACHMENTS . ARE THE RESPONSINLIIYOF THE OFTHIS ALTERNATE Q" MAY BE USED TO OMIT IN 3' PROGRESS INSPECT M C 3. oFFRAtaNG Y � NOTE THIS COMMON MAY BE USEDATALL CONNECDON AREAS AS O ALTERNATE CONNECTION Z . W � Q U -�,TT \TT•� 11 LI EXISTING COACH �/� FRAME - .-._. EL RAILwI#Blct-114STAINLESSSTEEL SCREWS Q 5' O.C. INTO EXISTING EXISTING MOBILE HOME PRE -PUNCHED HOLES. OVERHANG FRAMING 8 ROOFING -80STINGALUM. POLYSTYRENE FOAM INSERT GUTTER PGE DETAIL ALTERNATE ATTACHMENT RAIL FASTENING #1 EACH PAN COL. 3 BEAM N.T.S. ,. N.T.S. ALTERNATE PATIO PAN ROOF ATTACHMENT DETAIL "B" N.T.S. BUTYL RUBBER SI Y RIDGED POLYSTYRENE INSULATION OVERLAPPING — .024ALUMROOF \ EXTRUDED ALUM. ATTACH RAIL wl #8X1 1/4 S.M.S. 3' O.C. 2X3 P.T. WI#8X3' W.S. @ 3' O.C. EXISTING CENTER CAP J `EXISTING COACH FRAMING DOUBLE-WIDE.RIDGE DETAIL WT:S BUM RUBBER SI 2' RIDGED POLYSTYRENE INSULATION OVERLAPPING— .024 ALUM ROOF \ .024 ALUM F T RIDGED POLYSTYRENE INSULATION EXISTING MOBILE HOI:!E ROOF-7 EXTRUDED ALUM. ATTACH RAIL wl #8x3% S.M.S. 3' O.C. P.T. WOOD BLOCKwl #8X3' W.S. @ SPANNING _ TO STRAIGHTEN WOOD ONLY il"Efifitr-ff If Q 024 GALVALUME CLEAT ST. LUCG COUNTY o2a•ALUM THESE PLANS AND A BUILDING DIVISION REVIEWED AIRE SUB,)ECT TO AN FOR COMP REQUIRES BY FICLD REVIEWED BY DATE l� — .024'ALUM MAYBE NECESSMY LAN i�AppNN�D PERMIT 6®I'iil��Y WIN A4 A N I�UM.. &t C IL LJOB OR STYRENE-BUTADIENE ' I '®.W L BE MADE ACTORY SEAM DESIGN FOR RUBBERSEALANT LUMINUM ROOF COVERINGS BETWEEN SHEET $ CLEAT BUMRUBBERSEAL OVER SOLID ROOFS ONLY PRODUCT APPROVAL_#FL5739� 024 ALUM FASCIA N.T.S. ' f ATADJACENTPATIO ROOF NOTES: PROVIDE.MA 0 ASHING 2X3 P.T. WI #BX3' H.S. @ 6' O.C. INTO EXISTING CA INTO PATIO ROOF (MIN 8') ���/��/ wl#8 SMS Q 12' O.C. ` EXISTING EXTRUDED WALL CHANNEL EXISTING COACH FRAME FASCIA EDGE DETAIL] = t `. N.T.S`.— —r- ALTERNATE COACH & PATIO ROOF ATTACHMENT #a EXISTING CENTERCAPCOACH FRAMING CONNECTION DETAIL (NTS) (NO DROP BETWEEN ROOFS) DOUBLE WIDE RIDGE DETAIL USING ALTERNATE #1 ATTACHMENT (NTS) MOBILE HOME ALUMINUM ROOF OVER PLAN FOR 185 MPH EXPOSURE C OWNER: cl \GAS} p L.A 5� \sI ADDRESS:—;� r CITY: po cLT S;rr , LvC 1 F STATE: LOT# BLOCK# 1.) THIS DESIGN CONFORMS TO THE 2014 FLORIDA BUILDING CODE FOR A (CATEGORY IT BUILDING FOR WIND.LOADING OF 185 MPH. EXPOSURE CA DETERMINED_BYASCESTANDARD7.1"''-LL �-� 2.) THIS DESIGN CONFORMS TO FLORIDA STATUTE 15C-2.0081 FOR MOBILE/MANUFACTURED HOME REPAIR AND REMODELING. 3.) ALUMINUM ROOFING IS DESIGNED FOR USE OVER A SOLID ROOF ONLY. IT SHALL NOT BE USED AS A STRUCTURAL ROOF SYSTEM. - 4.) THE ROOF COVERING SHALL NOT OVERHANG THE EXISTING ROOF. 5.) ENGINEER IS NOT RESPONSIBLE FOR STRUCTURAL INTEGRITY OF EXISTING ROOF. THE STRUCTURE OF THE EXISTING ROOF SHOULD BE ABLE TO SUPPORT THE CONSTRUCTION LOADING FOR THE NEW ROOF SYSTEM. 6.) MAXIMUM WIDTH OF A SINGLE WIDE MOBILE HOME NOT TO EXCEED 14'-0. 7.) MAXIMUM WIDTH OF A DOUBLE WIDE MOBILE HOME NOT. CEED 2&-0 8.) INSULATION TO BE POLYSTYRENE FORM APROX. DENSI R 9.) MAXIMUM HEIGHT OF MOBILE HOME NOT TO EXCEED 1S 10.) MINIMUM THICKNESS OF ALL ROOF FLASHING TO BE .0 ,uALU r ; 11.) THE R-VALUE OF THE 2' EPS. INSULATION IS R=6.7. SHE . NTd::`'^ tltl ►: q yccQD U I � � 4 !1 O N to -j �03jb � . 03 07 q � N b a� F, J ZA NOT VALID UNLESS DATED' & SEALED WITH EMBOSSED f^ GINEE EAI. f I =� ZIP: 3y�s Z171�% MES BU OU� ((! ?Ti RANGE: PROFESSIONAL ENGINEER 20311 0STATE OF FLORIDA .024 ALUM 7 RIDGED POLYSTYRE1 INSULATION 3' MIN THICK BONDED PANEL NOTE: MAX 17 SPAN BONDED PANEL wf#BX1114 S.M.S.3'O.C. /-BUTYL RUBBER SEAL 2)W PTw//14xV TEXSCREWS @ B' O.C. THIRD BONDED PANEL INTO EXISTING BEAM 024 ALUM BASHING _ EXTRUDED ALUM. ATTACH RAIL w/pBX11/4 S.M.S. T O.C. BUTYL RUBBER SEAL ;eiftlli__.024 ALUM BASHING 1' MAX. O.H. -1 EXISTING - COL RF FBEAMRAMING OVERHANG OR FRAMING BONDED PANEL ROOF EDGE DETAI N.T.S.. .024 ALUM ROOF 2' RIDGED POLYSTYRENE EXTRUDED ALUM. ATTACH RAIL INSULATION wl#BX1114 S.M.S. 3'O.C. 'r^r BUM RUBBER SEAL �.♦�♦� ♦� .024 ALUM FLASHING T MIN THICK BONDED PANEL 20PTwfftL1'SMS@4'0S0 NOTE EXTRUDED METAL Q BONDED PANEL MAX 17 SPAN BONDED PANEL j P MAX O.H. `.032 EXTRUDED FASCIA EXISTING ALUM. / ElOST1NG OR GUTTER ON\\ COL&BEAM.' OVERHANGOR BTAMING BONDED PANEL ROOF EDGE DETAIL #1 N.T.S. MOBILE. HOME ALUMINUM ROOF OVER PLAN FOR 185 MPH EXPOSURE C EXTRUDED ALUM. ATTACH RAIL w/ #8X1 1/4 S.M.S. 3' O.C. 12'x12'x.024 ALUM CAP MAX 28' WIDTH PARK MODEL DETAIL A N.T.S. ' EXTRUDED ALUM. ATTACH RAIL W/ #8XII 1/4 S.M.S. 3' O.C. 12'x12'x.024 ALUM CAP LAP OF ROOF ROLL TO BE ON DOWNWARD SIDE MAX 14' WIDTH PARK MODEL DETAIL B N.T.S. RUBBER SEAL 2"x4' PT CONT. wf #8x3' WOOI L-WS ® 6' O.C. TO RIDGE BEAM 6148x3 ' _,,j SCREW TO EACH TRUSS 2' RIDGED POLYSTYRENE INSULATION �2-x4' WOOD TRUSS C1 24'O.C. w/ 1/2' SHEATHING EXTRUDED ALUM. ATTACH RAIL w/.#BX1.1/4 S.M.S. 3' O.C. ��J♦. BUM RUBBER SEAL SEE GUTTER 6 FASCIA EDGE DETAILS, S-1 2x4 P.T. w/#8x3'WOOD SCREWS MAX 18. O.H. --� @ 6' O.C. TO FASCIA w/ 1-#W TO EACH TRUSS TAIL (d 24'O.C. CONTINUOUS 2' FASCIA TYP. YL RUBBER SEAL 2'x4' PT CONT. W/ 24Bx3' WOOD SCREWS TO EACH TRUSS co . O O 4A to v O omi q 03 � m ti Qu N y o w C of d Z LU � Q 0 0 U 03 N m w o� toco 2' RIDGED POLYSTYRENE INSULATION `F 2-0- WOOD TRUSS @ F 24'O.C. w/ 1/2' SHEATHING RUDED ALUM. ATTACH RAIL O N Ti C.5 N N w/ #BX1 114 S.M.S. 3' O.C. V .�♦1 ♦♦ ♦ l BUM RUBBER SEAL � 4z m � � w SEE U FASCIA DS E co m j DETAILS. S-1 � Cp d0 � MAX 18' O.H.- 2x4 P.T. w/ #8x3'WOOD SCREWS CAA 12' O.C. TO FASCIAw/ 1-#8x3' Q) cy O Q TO EACH TRUSS TAIL ® 24'O.C. rr, ' CONTINUOUS r 2' FASCIA TYP. N b �1 04mto q 4p 03 F!."- L �J) L_' t_a tv cq �c Orb �Qo) SHEET No.: S2 Of 2 w 04 O OWNER: NOT VALID UNLESS DATED 4 ADDRESS: & SEALEDWITH EMBOSSED �N�INFAL JCITY- STATE: ZIP: Z( �11 n. P.E. seLOT# BLOCK# RANGE: PROFESSIONAL ENGINEER 20311 STATE OF FLORIDA 0