HomeMy WebLinkAboutEnergy Eficiency Coden VL_D
DEC Z 12017
FORM R405-2014 PERMITTING
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation -,Residential Performance Method
Project Name: AULTZ RESIDENCE
Builder Name: TC CUSTOM HOMES
Street: 4607 MYRTLE DRIVE
Permit Office: CITY OF PORT ST LUCIE
City, State, Zip: PORT ST LUCIE , FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
9. Wall Types (2513.7 sgft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 2425.70 ftz
b. Frame - Wood, Adjacent
R=11.0 88.00 ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
3
d. N/A
R= ft2
10. Ceiling Types (2135.0 sgft.)
Insulation Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=30.0 2135.00 ft2
6. Conditioned floor area above grade (ft2)
2135
b. N/A
R= ft2
Conditioned floor area below grade (ft2)
0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows (356.0 sqft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: LAUNDRY ROOM 6 175
a. U-Factor: Dbl, U=0.32
229.00 ft2
SHGC: SHGC=0.22
b. U-Factor: Dbl, U=0.32
122.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.19
a. Gentral Unit
42.0 SEER:16.00
c. U-Factor: Dbl, U=0.28
5.00 ft2
SHGC: SHGC=0.21
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A
ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
urea Weighted Average Overhang Depth:
1.500 ft.
Area Weighted Average SHGC:
0.210
14. Hot water systems
a. Electric
Cap: 40 gallonsEF:
8. Floor Types (2135.0 sgft.)
Insulation Area
0.980
a. Slab -On -Grade Edge Insulation
R=0.0 2135.00 ft2
b. Conservation features
b. N/A
R= ft2
None
c. N/A
R= ft2
15. Credits
None
Glass/Floor Area: 0.167
Total Proposed Modified Loads: 75.08
PASS
Total Baseline Loads: 82.38
I hereby certify that the plans and specifications covered by
Review of the plans and
�'CE SrAT
this calculation are i ompliance with the Florida Energy
Code.
specifications covered by this
calculation indicates compliance
PREPARE Y:
DATE:
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
ti lrry,:°"�. •y r' :,� O'
-
compliance with Section 553.908
* �'
hereby certify that this uilding, s d signed, is in compliance
Florida Statutes.
CAD
with the Florida Energy de.
y�rg;'i
Oy1/NER/,o,�ENT
/G- I L,
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017
this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50 (R402.4.1.2).
File COPY
12/8/201711:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software bs " Page 1 of 6
FORM R405-2014
PROJECT
Title: AULTZ RESIDENCE
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 2135
Lot #
Owner:
Total Stories: 1
Block/SubDivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name: TC CUSTOM HOMES
Rotate Angle: 0
Street:
4607 MYRTLE
DRIVE
Permit Office: CITY OF PORT ST LUCIE
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
PORT ST LUCIE
,
Family Type: Single-family
FL,
' New/Existing: New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp
Heating
Design
Daily Temp
V Design Location TMY Site
Zone 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 2 39
90
70
75
299
62
Low
BLOCKS
Number Name Area
Volume
1 Entire House 2135
25786
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1 MASTER BATH 150
1500 No
0
1
Yes
Yes
Yes
r 2 M WIC 80
800 No
0
1
No
Yes
Yes
3 M TOILET 25
250 No
0
1
Yes
Yes
Yes
4 MASTER BEDROO 289
4046 No
0
1
1
Yes
Yes
Yes
5 FAMILY ROOM 649
9086 No
0
1
Yes
Yes
Yes
6 KITCHEN 171
2394 Yes
0
1
No
Yes
Yes
7 WIC 3 55
550 No
0
1
Yes
Yes
Yes
8 BEDROOM 3 192
1920 No
0
1
1
Yes
Yes
Yes
9 BATH 2 63
630 No
0
1
Yes
Yes
Yes
10 BEDROOM 2 182
1820 No
0
1
1
Yes
Yes
Yes
11 CLST 2 14
140 No
0
1
No
Yes
Yes
12 LAUNDRY ROOM 129
1290 No
0
1
Yes
Yes
Yes
13 NOOK 84
840 No
0
1
Yes
Yes
Yes
.14 HALL 52
520 No
0
1
No
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation MASTER BATH 27 ft 0
150 ft2
____
1 0
0
2 Slab -On -Grade Edge Insulation M WIC 1 ft 0
80 ft2
1 0
0
3 Slab -On -Grade Edge Insulation M TOILET 5 ft 0
25 ft2
1 0
0
4 Slab -On -Grade Edge Insulation MASTER BEDRO 34 ft 0
289 ft2
____
1 0
0
12/8/2017 11:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 2 of 6
FORM R4t15-9014
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
5 Slab -On -Grade Edge Insulation
FAMILY ROOM 47 ft
0
649 ft2
____
1
0
0
6 Slab -On -Grade Edge Insulation
KITCHEN 1 ft
0
171 ft2
___-
1
0
0
7 Slab -On -Grade Edge Insulation
WIC 3 lift
0
55 ft2
____
1
0
0
8 Slab -On -Grade Edge Insulation
'
BEDROOM 3 31 ft
0
192 ft2
____
1
0
0
9 Slab -On -Grade Edge Insulation
BATH 2 7 ft
0
63 ft2
1
0
0
10SIab-On-Grade Edge Insulation
BEDROOM 2 14 ft
0
182 ft2
-__-
1
0
0
11Slab-On-Grade Edge Insulation
CLST 2 1 ft
0
14 ft2
____
1
0
0
12SIab-On-Grade Edge Insulation
LAUNDRY ROOM 15 ft
0
129 112
__-_
1
0
0
13SIab-On-Grade Edge Insulation
NOOK 19.2 ft
0
84 ft2
____
1
0
0
14SIab-On-Grade Edge Insulation
HALL 1 ft
0
52 ft2
____
1
0
0
ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
# Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Hip
Metal 2388 ft2
0 ft2
Light
0.6
No
0.9
No
0
26.6
ATTIC
v # Type
Ventilation Vent Ratio (1
in)
Area
RBS
IRCC
1 Full attic
Vented
150
2135 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area Framing Frac Truss Type
1 Under Attic (Vented)
MASTER BATH
30
Blown
150 ft2
0.1
Wood
2 Under Attic (Vented)
M WIC
30
Blown
80 ft2
0.1
Wood
3 Under Attic (Vented)
M TOILET
30
Blown
25 ft2
0.1
Wood
4 Under Attic (Vented)
MASTER BEDRO
30
Blown
289 ft2
0.1
Wood
5 Under Attic (Vented)
FAMILY ROOM
30
Blown
649 ft2
0.1
Wood
6 Under Attic (Vented)
KITCHEN
30
Blown
171 ft2
0.1
Wood
7 Under Attic (Vented)
WIC 3
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented)
BEDROOM 3
30
Blown
192 ft2
0.1
Wood
9 Under Attic (Vented)
BATH 2
30
Blown
63 ft2
0.1
Wood
10 Under Attic (Vented)
BEDROOM 2
30
Blown
182 ft2
0.1
Wood
11 Under Attic (Vented)
CLST 2
30
Blown
14 ft2
0.1
Wood
12 Under Attic (Vented)
LAUNDRY ROOM
30
Blown
129 ft2
0.1
Wood
13 Under Attic (Vented)
NOOK
30
Blown
84 ft2
0.1
Wood
14 Under Attic (Vented)
HALL
30
Blown
52 ft2
0.1
Wood
12/8/2017 11:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2014
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
Space
1
N
Exterior
Concrete Block - Ext InsMASTER BA
4.1
12
0 10
0
120.0 ft2
0
0
0.6
0
2
W
Exterior
Concrete Block - Ext Ins&ASTER BA
4.1
15
0 10
0
150.0 ft2
0
0
0.6
0
3
N
Exterior
Concrete Block - Ext Insults TOILET
4.1
5
0 10
0
50.0 ft2
0
0
0.6
0
4
S
Exterior
Concrete Block - Ext InsLMASTER BE
4.1
17
0 14
0
238.0 ft2
0
0
0.6
0
5
W
Exterior
Concrete Block - Ext InsdLIASTER BE
4.1
17
0 14
0
238.0 ft2
0
0
0.6
0
6
N
Exterior
Concrete Block - Ext Insi AMILY ROO
4.1
21
0 14
0
294.0 ft2
0
0
0.6
0
7
E
Exterior
Concrete Block - Ext InsdIAMILY ROO
4.1
4
0 14
0
56.0 ft2
0
0
0.6
0
8
S
Exterior
Concrete Block - Ext InsOIAMILY ROO
4.1
22
0 14
0
308.0 ft2
0
0
0.6
0
9
S
Exterior
Concrete Block - Ext Insul WIC 3
4.1
6
0 10
0
60.0 ft2
0
0
0.6
0
10
W
Exterior
Concrete Block- Ext Insul WIC 3
4.1
5
0 10
0
50.0 ft2
0
0
0.6
0
11
E
Exterior
Concrete Block - Ext InstBEDROOM 3
4.1
12
0 10
0
120.0 ft2
0
0
0.6
0
12
S
Exterior
Concrete Block - Ext InsZEDROOM 3
4.1
15
0 10
0
150.0 ft2
0
0
0.6
0
13
W
Exterior
Concrete Block - Ext Insi9EDROOM 3
4.1
4
0 10
0
40.0 ft2
0
0
0.6
0
14
E
Exterior
Concrete Block - Ext Insul BATH 2
4.1
7
0 10
0
70.0 ft2
0
0
6.6
0
15
E
Exterior
Concrete Block - Ext Ins51EDROOM 2
4.1
14
0 10
0
140.0 ft2
0
0
0.6
0
16
N
Exterior
Concrete Block - Ext InsLUAUNDRY R
4.1
13
0 10
0
130.0 ft2
0
0
0.6
0
17
E
Exterior
Concrete Block - Ext InsLUAUNDRY R
4.1
2
0 10
0
20.0 ft2
0
0
0.6
0
18
N
Exterior
Concrete Block- Ext Insul NOOK
4.1
5
0 10
0
50.0 ft2
0
0
0.6
0
19
NE
Exterior
Concrete Block.- Ext Insul NOOK
4.1
3
7 10
0
35.8 ft2
0
0
0.6
0
20
W
Exterior
Concrete Block- Ext Insul NOOK
4.1
7
0 10
0
70.0 ft2
0
0
0.6
0
21
NW
Exterior
Concrete Block- Ext Insul NOOK
4.1
3
7 10
0
35.8 ft2
0
0
0.6
0
22
W
Garage
Frame - Wood LAUNDRY R
11
8
11
88.0 ft2
0
0 0.600000
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Omt ID
Frame Panes NFRC U-Factor
SHGC
Area
Depth
Separation
Int Shade
Screening
1
N 1
Vinyl Low-E Double Yes
0.32
0.22
4.0 ft2
1 ft6 in
1 ft 4 in
None
None
2
N 1
Vinyl Low-E Double Yes
0.32
0.22
24.0 ft2
1 ft 6 in
1 ft 4 in
None
None
3
W 2
Vinyl Low-E Double Yes
0.28
0.21
5.0 ft2
1 ft 6 in
1 ft 4 in
None
None
4
S 4
Vinyl Low-E Double Yes
0.32
0.19
20.0 ft2
1 ft 6 in
1 ft 4 in
None
None
5
W 5
Vinyl Low-E Double Yes
0.32
0.19
30.0 ft2
1 ft 6 in
1 ft 4 in
None
None
6
N 6
Vinyl Low-E Double Yes
0.32
0.22
15.0 ft2
1 ft 6 in
1 ft 4 in
None
None
7
N 6
Vinyl Low-E Double Yes
0.32
0.22
96.0 ft2
1 ft 6 in
1 ft 4 in
None
None
8
S 8
Vinyl Low E Double Yes
0.32
0.19
12.0 ft2
1 ft 6 in
1 ft 4 in
None
None
9
S 8
Vinyl Low-E Double Yes
0.32
0.19
20.0 ft2
1 ft 6 in
1 ft 4 in
None
None
10
S 9
Vinyl Low-E Double Yes
0.32
0.22
4.0 ft2
1 ft 6 in
1 ft 4 in
None
None
11
E 11
Vinyl Low-E Double Yes
0.32
0.22
15.0 ft2
1 ft 6 in
1 ft 4 in
None
None
12
S 12
Vinyl Low-E Double Yes
0.32
0.19
20.0 ft2
1 ft 6 in
1 ft 4 in
None
None
13
E 14
Vinyl Low-E Double Yes
0.32
0.22
6.0 ft2
1 ft 6 in
1 ft 4 in
None
None
14
E 15
Vinyl Low-E Double Yes
0.32
0.22
15.0 ft2
1 ft 6 in
1 ft 4 in
None
None
15
N 16
Vinyl Low-E Double Yes
0.32
0.22
6.0 ft2
1 ft 6 in
1 ft 4 in
None
None
16
N 18
Vinyl Low-E Double Yes
0.32
0.19
20.0 ft2
1 ft 6 in
1 ft 4 in
None
None
17
NE 19
Vinyl Low-E Double Yes
0.32
0.22
10.0 ft2
1 ft 6 in
1 ft 4 in
None
None
12/8/201711:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 4 of 6
FORM R405-2014
WINDOWS
Orientation shown is the entered, Proposed orientation.
V #
Wall
Ornt ID Frame Panes
NFRC
Overhang
U-Factor SHGC Area Depth Separation Int Shade
Screening
18
19
W 20 Vinyl Low-E Double Yes
NW 21 Vinyl Low-E Double Yes
0.32 0.22 24.0 ft2 1 ft 6 in 1 ft 4 in None
0.32 0.22 10.0 ft2 1 ft 6 in 1 ft 4 in None
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
441 ft2
441 ft2
8 ft lift 11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50)
.000537
3008.4 165.16 310.6 .3922 7
HEATING SYSTEM .
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
Electric Strip Heat
None
COP:1 27 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
,1
Central Unit
Split
SEER: 16 42 kBtu/hr 1260 cfm 0.8 1
sys#1
•
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.98 40 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
/
#
— Supply --
Location R-Value Area
— Return -- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
Attic 6 175 ft2
Attic
18 ft2 Default Leakage LAUNDRY (Default) c(Default) c
1 1
1218/201711:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2014
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
CoolingJan
HeatinJan
Feb
H Feb
Mar
Mar
A r
APr
[
[
Ma
May
Jun
Jun
Jul
Jul
Au
AuSep
Se
Oct
f Oct
Nov
Nov
Dec
Dec
Vent in Jan
Feb
Mar
A r
[
May
Jun
Jul
Aug
Se
[X] Oct
Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (W D)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating (W D)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
12/8/201711:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 6 of 6
FORM R405-2014
TABLE 402.4.1.
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: AULTZ RESIDENCE Builder Name: TC CUSTOM HOMES
Street: 4607 MYRTLE DRIVE Permit Office: CITY OF PORT ST LUCIE
City, State, Zip: PORT ST LUCIE , FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/doorjambs and framing and skylights and
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to
available space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
12/8/2017 11:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 91
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows"
Description
a. U-Factor:
Dbl, U=0.32
SHGC:
SHGC=0.22
b. U-Factor:
Dbl, U=0.32
SHGC:
SHGC=0.19
c. U-Factor:
Dbl, U=0.28
SHGC:
SHGC=0.21
' d. U-Factor:
N/A
SHGC:
Area Weighted Average Overhang Depth:
.Area Weighted Average SHGC:
4607 MYRTLE DRIVE, PORT ST LUCIE, FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single family
a. Concrete Block - Ext Insul, Exterior
R=4.1
2425.70 ft2
b. Frame - Wood, Adjacent
R=11.0
88.00 ft2
1
c. N/A
R=
ft2
3
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
No
a. Under Attic (Vented)
R=30.0
2135.00 ft2
2135
b. N/A
R=
ft2
c. N/A
R=
ft2
Area
229.00 ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: LAUNDRY ROOM
6 175
122.00 ft2
12. Cooling systems
kBtu/hr
Efficiency
5.00 ft2
a. Central Unit
42.0
SEER:16.00
ft2
1.500 ft.
0.210
8. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 2135.00 ft2
b. N/A R= ft2
c. N/A R= ft2
13. Heating systems
a. Electric Strip Heat
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
kBtu/hr Efficiency
27.0 COP:1.00
Cap: 40 gallons
EF: 0.98
None
I certify that this home has complied with the Florida Energy Efficiency Code for Building ST
Construction through the above energy saving features which will be installed (or exceeded)o
in this home before final i pectin . Otherwise, a new EPL Display Card will be completedve
based on installed Code zbmplia t fea res. +n„r?�%: • sr�;';;,.''Q,
Builder Signature: Date: 2
,,��
Address of New Home: pq a�%�!"r'� Cit /FL Zi
. v� I" I V I''�'� � (r. Y Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
12/8/2017 11:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1