Loading...
HomeMy WebLinkAboutEnergy Eficiency Coden VL_D DEC Z 12017 FORM R405-2014 PERMITTING FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation -,Residential Performance Method Project Name: AULTZ RESIDENCE Builder Name: TC CUSTOM HOMES Street: 4607 MYRTLE DRIVE Permit Office: CITY OF PORT ST LUCIE City, State, Zip: PORT ST LUCIE , FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2513.7 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 2425.70 ftz b. Frame - Wood, Adjacent R=11.0 88.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (2135.0 sgft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2135.00 ft2 6. Conditioned floor area above grade (ft2) 2135 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows (356.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: LAUNDRY ROOM 6 175 a. U-Factor: Dbl, U=0.32 229.00 ft2 SHGC: SHGC=0.22 b. U-Factor: Dbl, U=0.32 122.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.19 a. Gentral Unit 42.0 SEER:16.00 c. U-Factor: Dbl, U=0.28 5.00 ft2 SHGC: SHGC=0.21 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: urea Weighted Average Overhang Depth: 1.500 ft. Area Weighted Average SHGC: 0.210 14. Hot water systems a. Electric Cap: 40 gallonsEF: 8. Floor Types (2135.0 sgft.) Insulation Area 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2135.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.167 Total Proposed Modified Loads: 75.08 PASS Total Baseline Loads: 82.38 I hereby certify that the plans and specifications covered by Review of the plans and �'CE SrAT this calculation are i ompliance with the Florida Energy Code. specifications covered by this calculation indicates compliance PREPARE Y: DATE: with the Florida Energy Code. Before construction is completed this building will be inspected for ti lrry,:°"�. •y r' :,� O' - compliance with Section 553.908 * �' hereby certify that this uilding, s d signed, is in compliance Florida Statutes. CAD with the Florida Energy de. y�rg;'i Oy1/NER/,o,�ENT /G- I L, BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017 this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50 (R402.4.1.2). File COPY 12/8/201711:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software bs " Page 1 of 6 FORM R405-2014 PROJECT Title: AULTZ RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2135 Lot # Owner: Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: TC CUSTOM HOMES Rotate Angle: 0 Street: 4607 MYRTLE DRIVE Permit Office: CITY OF PORT ST LUCIE Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: PORT ST LUCIE , Family Type: Single-family FL, ' New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2135 25786 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BATH 150 1500 No 0 1 Yes Yes Yes r 2 M WIC 80 800 No 0 1 No Yes Yes 3 M TOILET 25 250 No 0 1 Yes Yes Yes 4 MASTER BEDROO 289 4046 No 0 1 1 Yes Yes Yes 5 FAMILY ROOM 649 9086 No 0 1 Yes Yes Yes 6 KITCHEN 171 2394 Yes 0 1 No Yes Yes 7 WIC 3 55 550 No 0 1 Yes Yes Yes 8 BEDROOM 3 192 1920 No 0 1 1 Yes Yes Yes 9 BATH 2 63 630 No 0 1 Yes Yes Yes 10 BEDROOM 2 182 1820 No 0 1 1 Yes Yes Yes 11 CLST 2 14 140 No 0 1 No Yes Yes 12 LAUNDRY ROOM 129 1290 No 0 1 Yes Yes Yes 13 NOOK 84 840 No 0 1 Yes Yes Yes .14 HALL 52 520 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BATH 27 ft 0 150 ft2 ____ 1 0 0 2 Slab -On -Grade Edge Insulation M WIC 1 ft 0 80 ft2 1 0 0 3 Slab -On -Grade Edge Insulation M TOILET 5 ft 0 25 ft2 1 0 0 4 Slab -On -Grade Edge Insulation MASTER BEDRO 34 ft 0 289 ft2 ____ 1 0 0 12/8/2017 11:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 2 of 6 FORM R4t15-9014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulation FAMILY ROOM 47 ft 0 649 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulation KITCHEN 1 ft 0 171 ft2 ___- 1 0 0 7 Slab -On -Grade Edge Insulation WIC 3 lift 0 55 ft2 ____ 1 0 0 8 Slab -On -Grade Edge Insulation ' BEDROOM 3 31 ft 0 192 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulation BATH 2 7 ft 0 63 ft2 1 0 0 10SIab-On-Grade Edge Insulation BEDROOM 2 14 ft 0 182 ft2 -__- 1 0 0 11Slab-On-Grade Edge Insulation CLST 2 1 ft 0 14 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation LAUNDRY ROOM 15 ft 0 129 112 __-_ 1 0 0 13SIab-On-Grade Edge Insulation NOOK 19.2 ft 0 84 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation HALL 1 ft 0 52 ft2 ____ 1 0 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2388 ft2 0 ft2 Light 0.6 No 0.9 No 0 26.6 ATTIC v # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2135 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BATH 30 Blown 150 ft2 0.1 Wood 2 Under Attic (Vented) M WIC 30 Blown 80 ft2 0.1 Wood 3 Under Attic (Vented) M TOILET 30 Blown 25 ft2 0.1 Wood 4 Under Attic (Vented) MASTER BEDRO 30 Blown 289 ft2 0.1 Wood 5 Under Attic (Vented) FAMILY ROOM 30 Blown 649 ft2 0.1 Wood 6 Under Attic (Vented) KITCHEN 30 Blown 171 ft2 0.1 Wood 7 Under Attic (Vented) WIC 3 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) BEDROOM 3 30 Blown 192 ft2 0.1 Wood 9 Under Attic (Vented) BATH 2 30 Blown 63 ft2 0.1 Wood 10 Under Attic (Vented) BEDROOM 2 30 Blown 182 ft2 0.1 Wood 11 Under Attic (Vented) CLST 2 30 Blown 14 ft2 0.1 Wood 12 Under Attic (Vented) LAUNDRY ROOM 30 Blown 129 ft2 0.1 Wood 13 Under Attic (Vented) NOOK 30 Blown 84 ft2 0.1 Wood 14 Under Attic (Vented) HALL 30 Blown 52 ft2 0.1 Wood 12/8/2017 11:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 N Exterior Concrete Block - Ext InsMASTER BA 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 2 W Exterior Concrete Block - Ext Ins&ASTER BA 4.1 15 0 10 0 150.0 ft2 0 0 0.6 0 3 N Exterior Concrete Block - Ext Insults TOILET 4.1 5 0 10 0 50.0 ft2 0 0 0.6 0 4 S Exterior Concrete Block - Ext InsLMASTER BE 4.1 17 0 14 0 238.0 ft2 0 0 0.6 0 5 W Exterior Concrete Block - Ext InsdLIASTER BE 4.1 17 0 14 0 238.0 ft2 0 0 0.6 0 6 N Exterior Concrete Block - Ext Insi AMILY ROO 4.1 21 0 14 0 294.0 ft2 0 0 0.6 0 7 E Exterior Concrete Block - Ext InsdIAMILY ROO 4.1 4 0 14 0 56.0 ft2 0 0 0.6 0 8 S Exterior Concrete Block - Ext InsOIAMILY ROO 4.1 22 0 14 0 308.0 ft2 0 0 0.6 0 9 S Exterior Concrete Block - Ext Insul WIC 3 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 10 W Exterior Concrete Block- Ext Insul WIC 3 4.1 5 0 10 0 50.0 ft2 0 0 0.6 0 11 E Exterior Concrete Block - Ext InstBEDROOM 3 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 12 S Exterior Concrete Block - Ext InsZEDROOM 3 4.1 15 0 10 0 150.0 ft2 0 0 0.6 0 13 W Exterior Concrete Block - Ext Insi9EDROOM 3 4.1 4 0 10 0 40.0 ft2 0 0 0.6 0 14 E Exterior Concrete Block - Ext Insul BATH 2 4.1 7 0 10 0 70.0 ft2 0 0 6.6 0 15 E Exterior Concrete Block - Ext Ins51EDROOM 2 4.1 14 0 10 0 140.0 ft2 0 0 0.6 0 16 N Exterior Concrete Block - Ext InsLUAUNDRY R 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 17 E Exterior Concrete Block - Ext InsLUAUNDRY R 4.1 2 0 10 0 20.0 ft2 0 0 0.6 0 18 N Exterior Concrete Block- Ext Insul NOOK 4.1 5 0 10 0 50.0 ft2 0 0 0.6 0 19 NE Exterior Concrete Block.- Ext Insul NOOK 4.1 3 7 10 0 35.8 ft2 0 0 0.6 0 20 W Exterior Concrete Block- Ext Insul NOOK 4.1 7 0 10 0 70.0 ft2 0 0 0.6 0 21 NW Exterior Concrete Block- Ext Insul NOOK 4.1 3 7 10 0 35.8 ft2 0 0 0.6 0 22 W Garage Frame - Wood LAUNDRY R 11 8 11 88.0 ft2 0 0 0.600000 0 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.32 0.22 4.0 ft2 1 ft6 in 1 ft 4 in None None 2 N 1 Vinyl Low-E Double Yes 0.32 0.22 24.0 ft2 1 ft 6 in 1 ft 4 in None None 3 W 2 Vinyl Low-E Double Yes 0.28 0.21 5.0 ft2 1 ft 6 in 1 ft 4 in None None 4 S 4 Vinyl Low-E Double Yes 0.32 0.19 20.0 ft2 1 ft 6 in 1 ft 4 in None None 5 W 5 Vinyl Low-E Double Yes 0.32 0.19 30.0 ft2 1 ft 6 in 1 ft 4 in None None 6 N 6 Vinyl Low-E Double Yes 0.32 0.22 15.0 ft2 1 ft 6 in 1 ft 4 in None None 7 N 6 Vinyl Low-E Double Yes 0.32 0.22 96.0 ft2 1 ft 6 in 1 ft 4 in None None 8 S 8 Vinyl Low E Double Yes 0.32 0.19 12.0 ft2 1 ft 6 in 1 ft 4 in None None 9 S 8 Vinyl Low-E Double Yes 0.32 0.19 20.0 ft2 1 ft 6 in 1 ft 4 in None None 10 S 9 Vinyl Low-E Double Yes 0.32 0.22 4.0 ft2 1 ft 6 in 1 ft 4 in None None 11 E 11 Vinyl Low-E Double Yes 0.32 0.22 15.0 ft2 1 ft 6 in 1 ft 4 in None None 12 S 12 Vinyl Low-E Double Yes 0.32 0.19 20.0 ft2 1 ft 6 in 1 ft 4 in None None 13 E 14 Vinyl Low-E Double Yes 0.32 0.22 6.0 ft2 1 ft 6 in 1 ft 4 in None None 14 E 15 Vinyl Low-E Double Yes 0.32 0.22 15.0 ft2 1 ft 6 in 1 ft 4 in None None 15 N 16 Vinyl Low-E Double Yes 0.32 0.22 6.0 ft2 1 ft 6 in 1 ft 4 in None None 16 N 18 Vinyl Low-E Double Yes 0.32 0.19 20.0 ft2 1 ft 6 in 1 ft 4 in None None 17 NE 19 Vinyl Low-E Double Yes 0.32 0.22 10.0 ft2 1 ft 6 in 1 ft 4 in None None 12/8/201711:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2014 WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Area Depth Separation Int Shade Screening 18 19 W 20 Vinyl Low-E Double Yes NW 21 Vinyl Low-E Double Yes 0.32 0.22 24.0 ft2 1 ft 6 in 1 ft 4 in None 0.32 0.22 10.0 ft2 1 ft 6 in 1 ft 4 in None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 441 ft2 441 ft2 8 ft lift 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000537 3008.4 165.16 310.6 .3922 7 HEATING SYSTEM . # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts ,1 Central Unit Split SEER: 16 42 kBtu/hr 1260 cfm 0.8 1 sys#1 • HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / # — Supply -- Location R-Value Area — Return -- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 175 ft2 Attic 18 ft2 Default Leakage LAUNDRY (Default) c(Default) c 1 1 1218/201711:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2014 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan HeatinJan Feb H Feb Mar Mar A r APr [ [ Ma May Jun Jun Jul Jul Au AuSep Se Oct f Oct Nov Nov Dec Dec Vent in Jan Feb Mar A r [ May Jun Jul Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 12/8/201711:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2014 TABLE 402.4.1. AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: AULTZ RESIDENCE Builder Name: TC CUSTOM HOMES Street: 4607 MYRTLE DRIVE Permit Office: CITY OF PORT ST LUCIE City, State, Zip: PORT ST LUCIE , FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 12/8/2017 11:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 91 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor: Dbl, U=0.32 SHGC: SHGC=0.22 b. U-Factor: Dbl, U=0.32 SHGC: SHGC=0.19 c. U-Factor: Dbl, U=0.28 SHGC: SHGC=0.21 ' d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: .Area Weighted Average SHGC: 4607 MYRTLE DRIVE, PORT ST LUCIE, FL, New (From Plans) 9. Wall Types Insulation Area Single family a. Concrete Block - Ext Insul, Exterior R=4.1 2425.70 ft2 b. Frame - Wood, Adjacent R=11.0 88.00 ft2 1 c. N/A R= ft2 3 d. N/A R= ft2 10. Ceiling Types Insulation Area No a. Under Attic (Vented) R=30.0 2135.00 ft2 2135 b. N/A R= ft2 c. N/A R= ft2 Area 229.00 ft2 11. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: LAUNDRY ROOM 6 175 122.00 ft2 12. Cooling systems kBtu/hr Efficiency 5.00 ft2 a. Central Unit 42.0 SEER:16.00 ft2 1.500 ft. 0.210 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 2135.00 ft2 b. N/A R= ft2 c. N/A R= ft2 13. Heating systems a. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits kBtu/hr Efficiency 27.0 COP:1.00 Cap: 40 gallons EF: 0.98 None I certify that this home has complied with the Florida Energy Efficiency Code for Building ST Construction through the above energy saving features which will be installed (or exceeded)o in this home before final i pectin . Otherwise, a new EPL Display Card will be completedve based on installed Code zbmplia t fea res. +n„r?�%: • sr�;';;,.''Q, Builder Signature: Date: 2 ,,�� Address of New Home: pq a�%�!"r'� Cit /FL Zi . v� I" I V I''�'� � (r. Y Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 12/8/2017 11:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1