Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020 4 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ._ Project Name: 186A RH - FP080082 Builder Name: FOCUS HOMES Street: TBD PENNY LN Permit Office: City, State, Zip: _ FORT PIERCE, FL, 34951 Permit Number. Owner: FOCUS HOMES Jurisdiction: Design Location: FL, ST LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type41646.7 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1473.30 ftZ b. Frame -Wood, Adjacent R=13.0 173.33 ftZ 3. Number of units, if multiple family 1 c. N/A R= ftZ 4. Number of Bedrooms 4 d. N/A R= ftZ 5. Is this a worst case? Yes 11. Ceiling Types (1867.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1867.00 ftZ 6. Conditioned floor area above grade (ftZ) 1867 b. N/A R= ftZ Conditioned floor area below grade (ftZ) 0 c. N/A R= ftZ 7. Windows(125.0 sgft.) Description Area 12. Ducts a. Sup: Attic, Ret: Main, AH: Main R ftZ 6 320 a. U-Factor: Dbl, U=0.34 85.00 ftZ SHGC: SHGC=0.23 b. U-Factor: Dial, U=0.55 40.00 ftZ 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 29.2 SEER:16.00 c. U-Factor. N/A ftZ SHGC: Area Weighted Average Overhang Depth: 1.000 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.236 a. Electric Heat Pump 29.2 HSPF:9.00 8. Skylights Area c. U-Factor:(AVG) N/A ftZ 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1867.0 sqft.) Insulation Area EF:0.950 a. Slab -On -Grade Edge Insulation R=0.0 1867.00 ftZ b. Conservation features b. NIA R= ftZ None c. N/A R= ftZ 16. Credits Pstat Total Proposed Modified Loads: 52.90 Glass/Floor Area: 0.067 SS PASS Total Baseline Loads: 56.56 /"1, 1 hereby certify that the plans and specifications covered by Review of the plans and S7, this calculation are in compliance w' a Florida Energy specifications covered by this O1�$E �j' e O Code. calculation indicates compliance with the Florida Energy Code. I- nrrr,a:. ''�% •.;;:;'�i; `;.. „ O PREPARED BY: DATE: Before construction is completed this this building will be inspected for compliance with Section 553.908 c ' * ,� hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code GODZS�V OWNER/AGENT: ,A BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 10/5/2021 11:25 AM EnergyGauge(D USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORM R4ns-gflgtl INPI IT Al IMMARV r_WI=r--Kl ICT R1=131t'1RT PROJECT Title: I Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: 186A RH - FP080082 User FOCUS HOMES 1 FOCUS HOMES Detached New (From Plans) Bedrooms: 4 Conditioned Area: 1867 Total Stories: 1 Worst Case: Yes Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Street Address TBD PENNY LN St. Lucie FORT PIERCE, FL, 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5.% Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 9D 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 1867 16803 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1867 16803 Yes 4 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 164 ft 0 1867 ft2 0 0.3 0.7 ROOF V # Type Roof Gable Roof Materials Area Area Color Red Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2088 ft2 0 ft2 Medium N 0.85 No 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1867 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1867 ft2 0.07 Wood 10/5/2021 11:25 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHFCKI IST REPORT J WALLS . / Adjacent Space Cavity Width Height Sheathing Framing Solar Below `�/ Oint To-WaILT.yp_e p R-Vahle Et In Et In Area R-Vnlue.-Eraction-Absor_Grade"! 1 N 2 E 3 S 4 W 5 N I Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main Garage Frame - Wood Main 4.1 20 0 8 4.1 65 0 8 4.1 39 8 4.1 46 8 13 20 8 8 173.3 111:2 8 563.3 ft2 8 338.0 ft2 8 398.7 ft2 8 173.3 ft2 0 0.6 .0 0.6 0 0.6 0 0.6 0.19 0.01 0 0 0 0 0 DOORS # Ornt Door Type Space Storms U-Value Ft Width Height In Ft In Area 1 2 N Insulated Main N Insulated Main None None .16 3 .16 2 8 6 6 8 24 ft2 16.7 ft2 J WINDOWS Orientation shown is the entered orientation =>) changed to Worst Case. V # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 1 2 3 4 5 N 1 Vinyl Low-E Double Yes E 2 Vinyl Low-E Double Yes S 3 Metal Low-E Double Yes S 3 Vinyl Low-E Double Yes W 4 Vinyl Low-E Double Yes 0.34 0.23 N 0.34 0.23 N 0.55 0.25 N 0.34 0.23 N 0.34 0.23 N 30.0 ft2 1 ft0 in 15.0 ft' 1 ft 0 in 40.0 ft' 1 ft 0 in 20.0 ftZ 1 ft 0 in 20.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds 1 ft 0 in Drapes/blinds 1 ft 0 in Drapes/blinds 2 ft 0 in Drapes/blinds 2 It 0 in Drapes/blinds None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 408 ft2 408 ft2 45 ft 9 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 1960.3 107.55 201.91 .1324 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None Singl HSPF:9 29.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None Singl SEER: 16 29.2 kBtu/hr 876 cfm 0.73 1 sys#1 1 10/5/2021 11:25 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 47 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF INone None ft2 i DUCTS — - Supply --- --- Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 320 ftZ Main 20 ft' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb Mar f X� X A r Ma ]Jun Jul X] Au Se ]Oct [X Nov Dec Heatin0Jan X Feb Mar f X� Apr � May X] Jun ] Jul rX r] f X] AuIX X� SePX] Oct [X� Nov f X� Dec Ventin Jan Feb [X Mar [X A r May [X] Jun ] Jul [X] Aug X Se lX] Oct [X]]] Nov [X Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 0 1 - Electric Heat Pump 0% 1 - Central Unit MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ftz 0 ft 0.3 Main 10/5/2021 11:25 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL). DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index, the more efficient the home. ITBD PENNY LN, FORT PIERCE, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior b. Frame - Wood, Adjacent 3. Number of units, if multiple family 1 c. N/A 4. Number of Bedrooms 4 d. N/A 11. Ceiling Type and insulation level 5. Is this a worst case? Yes a. Under Attic (Vented) 6. Conditioned floor area (W) 1867 b. N/A 7. Windows" Description Area c. N/A a. U-Factor: Dbl, U=0.34 85.00 ft2 12. Ducts, location & insulation level a. Sup: Attic, Ret: Main, AH: Main SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.55 40.00 ft2 SHGC: SHGC=0.25 13. Cooling systems c. U-Factor: N/A ft2 a. Central Unit SHGC: d. U-Factor: N/A ft2 14_ Heating systems SHGC: a. Electric Heat Pump Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.236 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): NIA ft2 a. Electric SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1867.00 ft2 Credits (Performance method) b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features, Builder Signature: Date: c-z Address of New Home: City/FL Zip: Insulation Area R=4.1 1473.30 ft2 R=13.0 173.33 ft2 R= ft2 R= ft2 Insulation Area R=30.0 1867.00 ft2 R= ft2 R= ft2 R ft2 6 320 kBtu/hr Efficiency 29.2 SEER:16.00 kBtu/hr Efficiency 29.2 HSPF:9.00 Cap: 50 gallons EF: 0.95 Pstat I-TNE S IV T,gT�O purr: J n *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. ii, **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/5/2021 11:25 AM EnergyGaugeG USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: 186A RH - FP080082 Builder Name: FOCUS HOMES Street: TBD PENNY LN Permit Office: City, State, Zip: FORT PIERCE, FL, 34951 Permit Number. Y U Owner: FOCUS HOMES Jurisdiction: w Design Location: FL, ST LUCIE_CO_INTL U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier, Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed, per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing .in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover olates and walls or ceilinus- a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 10/5/2021 11:26 AM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1