HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020
4 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
._
Project Name: 186A RH - FP080082
Builder Name: FOCUS HOMES
Street: TBD PENNY LN
Permit Office:
City, State, Zip: _ FORT PIERCE, FL, 34951
Permit Number.
Owner: FOCUS HOMES
Jurisdiction:
Design Location: FL, ST LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type41646.7 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1473.30 ftZ
b. Frame -Wood, Adjacent
R=13.0 173.33 ftZ
3. Number of units, if multiple family 1
c. N/A
R= ftZ
4. Number of Bedrooms 4
d. N/A
R= ftZ
5. Is this a worst case? Yes
11. Ceiling Types (1867.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1867.00 ftZ
6. Conditioned floor area above grade (ftZ) 1867
b. N/A
R= ftZ
Conditioned floor area below grade (ftZ) 0
c. N/A
R= ftZ
7. Windows(125.0 sgft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Main, AH: Main
R ftZ
6 320
a. U-Factor: Dbl, U=0.34 85.00 ftZ
SHGC: SHGC=0.23
b. U-Factor: Dial, U=0.55 40.00 ftZ
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
29.2 SEER:16.00
c. U-Factor. N/A ftZ
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.236
a. Electric Heat Pump
29.2 HSPF:9.00
8. Skylights Area
c. U-Factor:(AVG) N/A ftZ
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (1867.0 sqft.) Insulation Area
EF:0.950
a. Slab -On -Grade Edge Insulation R=0.0 1867.00 ftZ
b. Conservation features
b. NIA R= ftZ
None
c. N/A R= ftZ
16. Credits
Pstat
Total Proposed Modified Loads: 52.90
Glass/Floor Area: 0.067
SS
PASS
Total Baseline Loads: 56.56
/"1,
1 hereby certify that the plans and specifications covered by
Review of the plans and
S7,
this calculation are in compliance w' a Florida Energy
specifications covered by this
O1�$E
�j' e O
Code.
calculation indicates compliance
with the Florida Energy Code.
I- nrrr,a:. ''�% •.;;:;'�i; `;.. „ O
PREPARED BY:
DATE:
Before construction is completed
this this building will be inspected for
compliance with Section 553.908
c '
* ,�
hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code
GODZS�V
OWNER/AGENT: ,A
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
10/5/2021 11:25 AM EnergyGauge(D USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R4ns-gflgtl INPI IT Al IMMARV r_WI=r--Kl ICT R1=131t'1RT
PROJECT
Title:
I Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
186A RH - FP080082
User
FOCUS HOMES
1
FOCUS HOMES
Detached
New (From Plans)
Bedrooms: 4
Conditioned Area: 1867
Total Stories: 1
Worst Case: Yes
Rotate Angle: 0
Cross Ventilation: No
Whole House Fan: No
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
TBD PENNY LN
St. Lucie
FORT PIERCE,
FL, 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5.%
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 9D
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
1867 16803
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1867 16803 Yes 4
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 164 ft 0
1867 ft2
0 0.3 0.7
ROOF
V #
Type
Roof Gable Roof
Materials Area Area Color
Red Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Hip Composition shingles 2088 ft2 0 ft2 Medium
N 0.85 No 0.9
No 0 26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 150 1867 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1867 ft2 0.07
Wood
10/5/2021 11:25 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT SUMMARY CHFCKI IST REPORT
J
WALLS
. / Adjacent Space Cavity Width Height Sheathing Framing Solar Below
`�/ Oint To-WaILT.yp_e p R-Vahle Et In Et In Area R-Vnlue.-Eraction-Absor_Grade"!
1 N
2 E
3 S
4 W
5 N
I
Exterior Concrete Block - Int Insul Main
Exterior Concrete Block - Int Insul Main
Exterior Concrete Block - Int Insul Main
Exterior Concrete Block - Int Insul Main
Garage Frame - Wood Main
4.1 20 0 8
4.1 65 0 8
4.1 39 8
4.1 46 8
13 20 8
8 173.3 111:2
8 563.3 ft2
8 338.0 ft2
8 398.7 ft2
8 173.3 ft2
0 0.6
.0 0.6
0 0.6
0 0.6
0.19 0.01
0
0
0
0
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Ft
Width Height
In Ft In
Area
1
2
N Insulated Main
N Insulated Main
None
None
.16 3
.16 2
8
6 6 8
24 ft2
16.7 ft2
J
WINDOWS
Orientation shown is the entered orientation =>) changed to Worst Case.
V #
Wall
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Overhang
Area Depth Separation Int Shade
Screening
1
2
3
4
5
N 1 Vinyl Low-E Double Yes
E 2 Vinyl Low-E Double Yes
S 3 Metal Low-E Double Yes
S 3 Vinyl Low-E Double Yes
W 4 Vinyl Low-E Double Yes
0.34 0.23 N
0.34 0.23 N
0.55 0.25 N
0.34 0.23 N
0.34 0.23 N
30.0 ft2 1 ft0 in
15.0 ft' 1 ft 0 in
40.0 ft' 1 ft 0 in
20.0 ftZ 1 ft 0 in
20.0 ft2 1 ft 0 in
1 ft 0 in Drapes/blinds
1 ft 0 in Drapes/blinds
1 ft 0 in Drapes/blinds
2 ft 0 in Drapes/blinds
2 It 0 in Drapes/blinds
None
None
None
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
408 ft2 408 ft2
45 ft
9 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .0004
1960.3 107.55 201.91 .1324
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ None
Singl HSPF:9
29.2 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype
Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1
Central Unit/ None
Singl SEER: 16 29.2 kBtu/hr 876 cfm 0.73 1
sys#1
1
10/5/2021 11:25 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
#
System Type SubType
Location EF Cap Use
SetPnt
Conservation
1
Electric None
Garage 0.95 50 gal 47 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model
# Area
Volume
FEF
INone
None
ft2
i
DUCTS
— - Supply ---
--- Return —
Air
CFM 25
CFM25
HVAC #
V #
Location R-Value Area
Location Area Leakage Type
Handler
TOT
OUT
QN RLF
Heat Cool
1
Attic 6 320 ftZ
Main 20 ft' Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan
Feb Mar
f X�
X A r Ma ]Jun Jul
X] Au
Se
]Oct
[X Nov
Dec
Heatin0Jan
X Feb Mar
f X� Apr � May X] Jun ] Jul
rX r]
f X] AuIX
X� SePX]
Oct [X� Nov
f X� Dec
Ventin Jan
Feb [X Mar
[X A r May [X] Jun ] Jul
[X] Aug
X Se
lX]
Oct [X]]] Nov
[X Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3 4 5 6
7
8
9
10 11
12
Cooling (WD)
AM 78
78 78 78 78 78
78
78
80
80 80
80
PM 80
80 78 78 78 78
78
78
78
78 78
78
Cooling (WEH)
AM 78
78 78 78 78 78
78
78
78
78 78
78
PM 78
78 78 78 78 78
78
78
78
78 78
78
Heating (WD)
AM 66
66 66 66 66 68
68
68
68
68 68
68
PM 68
68 68 68 68 68
68
68
68
68 66
66
Heating (WEH)
AM 66
66 66 66 66 68
68
68
68
68 68
68
PM 68
68 68 68 68 68
68
68
68
68 66
66
MECHANICAL VENTILATION
Type
Supply CFM
Exhaust CFM Fan Watts HRV Heating System
Run Time
Cooling System
None
0
0 0 0 1 - Electric Heat Pump
0%
1 - Central Unit
MASS
Mass Type
Area Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ftz 0 ft
0.3
Main
10/5/2021 11:25 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL). DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the EnergyPerformance Index, the more efficient the home.
ITBD
PENNY LN, FORT PIERCE, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
b. Frame - Wood, Adjacent
3. Number of units, if multiple family
1
c. N/A
4. Number of Bedrooms
4
d. N/A
11. Ceiling Type and insulation level
5. Is this a worst case?
Yes
a. Under Attic (Vented)
6. Conditioned floor area (W)
1867
b. N/A
7. Windows" Description
Area
c. N/A
a. U-Factor: Dbl, U=0.34
85.00 ft2
12. Ducts, location & insulation level
a. Sup: Attic, Ret: Main, AH: Main
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.55
40.00 ft2
SHGC: SHGC=0.25
13. Cooling systems
c. U-Factor: N/A
ft2
a. Central Unit
SHGC:
d. U-Factor: N/A
ft2
14_ Heating systems
SHGC:
a. Electric Heat Pump
Area Weighted Average Overhang Depth:
1.000 ft.
Area Weighted Average SHGC:
0.236
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): NIA
ft2
a. Electric
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation Area
None
a. Slab -On -Grade Edge Insulation
R=0.0 1867.00 ft2
Credits (Performance method)
b. N/A
R= ft2
c. N/A
R= ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features,
Builder Signature: Date: c-z
Address of New Home: City/FL Zip:
Insulation
Area
R=4.1
1473.30 ft2
R=13.0
173.33 ft2
R=
ft2
R=
ft2
Insulation
Area
R=30.0
1867.00 ft2
R=
ft2
R=
ft2
R ft2
6 320
kBtu/hr Efficiency
29.2 SEER:16.00
kBtu/hr Efficiency
29.2 HSPF:9.00
Cap: 50 gallons
EF: 0.95
Pstat
I-TNE S
IV T,gT�O
purr: J n
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
ii,
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
10/5/2021 11:25 AM EnergyGaugeG USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: 186A RH - FP080082 Builder Name: FOCUS HOMES
Street: TBD PENNY LN Permit Office:
City, State, Zip: FORT PIERCE, FL, 34951 Permit Number.
Y
U
Owner: FOCUS HOMES Jurisdiction:
w
Design Location: FL, ST LUCIE_CO_INTL
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier,
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed,
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace wall
.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing .in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover olates and walls or ceilinus-
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
10/5/2021 11:26 AM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1