HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Standard Pacific RB 6810 Coventry Lot 30 Builder Name: Standard Pacific Homes Street!- Permit Office: City, State, Zip: FL, Permit Number: wnStandard Pacific Homes Jurisdiction: De_iy1 Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (3254.4 sqft.) Insulation Area 1,jSingle family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 2643.50 ft2 b. Frame - Wood, Adjacent R=11.0 610.93 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (3206.0 sqft.) Insulation - Area a. Under Attic (Vented) R=38.0 3206.00 ft2 6. Conditioned floor area above grade (ft2) 3205.80004882 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 11. Ducts R ft2 7. Windows(659.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AC 1 6 320 a. U-Factor: Dbl, U=1.07 433.90 ft2 b. Sup: Attic, Ret: Attic, AH: AC 2 6 140 SHGC: SHGC=0.30 b. U-Factor: Dbl, U=1.05 128.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a. Central Unit 44.5 SEER:14.00 c. U-Factor: Dbl, U=1.00 49.44 ft2 b. Central Unit 17.8 SEER:14.00 SHGC: SHGC=0.32 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 48.00 ft2 a. Electric Heat Pump 45.0 HSPF:8.20 SHGC: other (see details) b. Electric Heat Pump 17.6 HSPF:8.20 Area Weighted Average Overhang Depth: 5.528 ft. Area Weighted Average SHGC: 0.292 14. Hot water systems 8. Floor`Types (3206.0 sqft.) Insulation Area a..Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 3206.00 ft2 b. Conservation features EF: 0.910 b. N/A' R= ft2 None c. N/A R= ft2 15. Credits Pstat Gl�ss/Floor Area: 0.206Total Proposed Modified Loads: 42.62 GI ,s/Floor Area: 0.206 PASS Total Standard Reference Loads: 54.90 1 hereby certify that the plans and specifications covered by Review of the plans and ST4?A this calculation are in compliance with the Florida Energy specifications covered by this O�ZHE Code. h Digitally signed by Chris Wildroudt rI DN: cn=Chds Wildroudt, c=US, - Chris calculation indicates compliance p ' `'��", 1 o=Engineered Air, LLC, ou=New PREPARED BY: Construction Sales and with the Florida Energy Code. Before construction is completed nrp�"�. •:;=: ; �t O ngmeenng, S ; • . d DATE: ernail��hasw-engi�eeredai�l�. W-i I d ro u " this building will be inspected for __ O - .d# com Date:2015.03.26 16:03:41-04'00' compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance, Florida Statutes. g`4 with the Florida Ener Code. Oij y�,EIls� OWNER/AGENT: BUILDING OFFICIAL: DATE: 21 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with 403.2.2.1.1. - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist - Heat sys #1'�may be undersized. Size of 45.0 was increased to 51.0 for simulation. Please review the Manual J8 report.- Heat Sys #2 may be undersized. Size of 17.6 was increased to 17.6 for simulation. Please review the Manual J8 report. 3/26/2015 4:003 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 PROJECT Title: Standard Pacific RB 6810 Cov Bedrooms: 3 Address Type: Lot Information Building Type: User Conditioned Area: 3206 Lot # 30 Owner: Standard Pacific Homes Total Stories: 1 Block/Su bDivision: Riverbend # of Units: 1 Worst Case: No PlatBook: Builder Name: Standard Pacific Homes Rotate Angle: 0 Street: Permit Office: Cross Ventilation: County: St. Lucie Jurisdiction: Whole House Fan: City, State, Zip: , Family Type: Single-family FL, New/tAsting: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST LUCIE_CO_INTL 2 39 90 70 73 722 62 Low BLOCKS Number Name Area Volume 1 Block1 2345 23450 2 Block2 860.7999 8031.26416 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 AC 1 2345 23450 No 6 2 1 Yes Yes Yes 2 I AC 2 860.8 8031.264 No 2 1 1 Yes Yes Yes I FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio AC 1 248 ft 0 2345 ftz 0 0 1 2 Slab -On -Grade Edge Insulatio AC 2 124 ft 0 861 ft2 ___ 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Barrel the 3586 ftz 0 ftZ Medium 0.65 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 3206 ftz N N \ 3/26/2015 4:00 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) AC 1 38 2345 ft2 0.11 Wood 2 Under Attic (Vented) AC 2 38 861 ft2 0.11 Wood • WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below �A-Ornt To WaILType Space R Value -Et -In Ft -In Area R-Value-F-raction-Absor.-Grade./ 1 E Exterior Concrete Block - Int Insul AC 1 4.1 12.5 0 10 0 125 ft2 0.4 0 0.4 0 2 S Exterior Concrete Block - Int Insul AC 1 4.1 73 0 10 0 730 ft2 0.4 0 0.4 0 3 W Exterior Concrete Block - Int Insul AC 1 4.1 53 0 10 0 530 ft2 0.4 0 0.4 0 _ 4 N Exterior Concrete Block - Int Insul AC 1 4.1 68 0 10 0 680 ft2 0.4 0 0.4 0 5 E Garage Frame - Wood AC 1 11 38 0 10 0 380 ft2 0.4 0.4 0 6 N Garage Frame - Wood AC 1 11 3.5 0 10 0 35 ft2 0.4 0.4 0 7 E Garage Frame - Wood AC 2 11 21 0 9.33 0 195.9299 0.4 0 0.4 0 _ 8 S Exterior Concrete Block - Int Insul AC 2 4.1 40 0 9.33 0 373.2000 0.4 0 0.4 0 _ 9 W Exterior Concrete Block - Int Insul AC 2 4.1 22 0 9.33 0 205.2599 0.4 0 0.4 0 DOORS I # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated AC 1 None 0.6 3 0 8 0 24 ft2 I 2 E Wood AC 1 None 0.39 3 0 8 0 21.36000 I WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Double Yes 1 0.32 13.35999 11 ft 0 in 2 ft 0 in None None 2 E 1 Metal Low-E Double Yes 1.07 0.3 11.34000 1.5 ft 0 in 2 ft 0 in None None 3 S 2 Metal Low-E Double Yes 1.07 0.3 32.340001.5 ft 0 in 2 ft 0 in None None 4 S 2 Metal Low-E Double Yes 1 0.32 5.25 ft2 1.5 ft 0 in 2 ft 0 in None None 5 S 2 Metal Low-E Double Yes 1.07 0.3 22.68000 1.5 ft 0 in 2 ft 0 in None None 6 S 2 Metal Low-E Double Yes 1.07 0.3 8.812800 1.5 ft 0 in 2 ft 0 in None None 7 S 2 Metal Low-E Double Yes 1.07 0.3 58.489191.5 ft 0 in 2 ft 0 in None None 8 S 2 Metal Low-E Double Yes 1.07 0.3 19.49639 20 ft 0 in 2 ft 0 in None None 9 W 3 Metal Low-E Double Yes 1.07 0.3 155.9711 1.5 ft 0 in 2 ft 0 in None None 10 W 3 Metal Low-E Double Yes 1.05 0.28 128 ft2 11.5 ft 0 i 2 ft 0 in None None 11 N 4 Metal Low-E Double Yes 1 0.32 8.9856001.5 ft 0 in 2 ft 0 in None None 12 N 4 Metal Low-E Double Yes 1 0.32 21.84000 1.5 ft 0 in 2 ft 0 in None None 13 N 4 Metal Low-E Double Yes 1.07 0.3 27.345601.5 ft 0 in 2 ft 0 in None None 14 N 4 Metal Low-E Double Yes 1.07 0.3 16.170001.5 ft 0 in 2 ft 0 in None None 15 N 4 Metal Low-E Double Yes 0.77 0.22 48 ft2 20 ft 0 in 2 ft 0 in None None 16 W 9 Metal Low-E Double Yes 1.07 0.3 81.25 ft2 1.5 ft 0 in 0 ft 0 in None None 3/26/2015 4:00 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 800 ft2 800 ft2 100 ft loft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 WFrolehouse Best Guess 0.000500 4204.4 230.81 434.08 0.3650 8.0132 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts = 1 2 Electric Heat Pump Electric Heat Pump None None HSPF: 8.2 45 kBtu/hr 1 HSPF: 8.2 17.6 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit Central Unit Split Split SEER: 14 44.5 kBtu/hr 1335 cfm 0.75 1 SEER: 14 17.8 kBtu/hr 534 cfm 0.75 2 sys#1 sys#2 I HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation i I 1 I Electric None Garage 0.91 50 gal 60 gal 120 deg None I SOLAR HOT WATER SYSTEM IFSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS # --- Supply -- Location R-Value Area -- Return --- Air Percent Location Area Leakage Type Handler CFM 25 Leakage QN RLF HVAC # Heat Cool 1 2 Attic 6 320 ft2 Attic 6 140 ft2 Attic Attic 80 ft2 Default Leakage AC 1 (Default) (Default) % 60 ft2 Default Leakage AC 2 (Default) (Default) % 1 1 2 2 3/26/2015 4:00 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin an Feb Mar Apr May X Jun Jul Au Se Oct Nov Dec Jan Heating �) Feb MarAprMay 4 Jun JXJJul AuSeP rj f OctjNov X Dec Ventin Jan Feb X Mar [X A r Ma [ Jun Jul Aug Se [X Oct [X Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 3/26/2015 4:00 PM EnergyGauge@ USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: PERMIT #: , FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. -COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating controls and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and / sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in lWater Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or J variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. / 3/26/2015 4:00 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 78 The lower the Energy Performance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2 7. Windows- Description a. U-Factor: Dbl, U=1.07 SHGC: SHGC=0.30 b U-Factor: Dbl, U=1.05 SHGC: SHGC=0.28 c. U-Factor: Dbl, U=1.00 SHGC: SHGC=0.32 d.i U-Factor: other (see details) SHGC: other (see details) Arga Weighted Average Overhang Depth: Area Weighted Average SHGC: „ FL, New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Int Insul, Exterior R=4.1 2643.50 ft2 b. Frame - Wood, Adjacent R=11.0 610.93 ft2 1 c. N/A R= ft2 3 d. N/A R= ft2 10. Ceiling Types Insulation Area No a. Under Attic (Vented) R=38.0 3206.00 ft2 3206 b. N/A R= ft2 Area c. N/A R= ft2 433.90 ft2 11. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: AC 1 6 320 b. Sup: Attic, Ret: Attic, AH: AC 2 6 140 128.00 ft2 12. Cooling systems kBtu/hr Efficiency 49.44 ft2 a. Central Unit 44.5 SEER:14.00 b. Central Unit 17.8 SEER:14.00 48.00 ft2 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 45.0 HSPF:8.20 5.528 ft. b. Electric Heat Pump 17.6 HSPF:8.20 0.292 8. Floor Types Insulation Area a. or Edge Insulation R=0.0 3206.00 ft2 b. N/A R= ft2 c. N/A R= ft2 14. Hot water systems Cap: 50 gallons a. Electric EF: 0.91 b. Conservation features None 15. Credits Pstat II I ceftify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. w Builder Signature: Date: 2A j 0 0 TIJE S?q�$ Address of New Home: 5?11 ?j M kAf ((Da 1-IL City/FL Zip: gS c0D WET�O *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge@ USA - FlaRes2010 Section 405.4.1 Compliant Software Stan Pac RB 68,10 Coventry Model HVAC Load Calculations for Standard Pacific Homes Prepared By: Chris Wildroudt Engineered Air LLC CACO45860 2520 N Andrews Ave Ext Pompano Beach, FL 33064 954 974-7277 Wednesday, February 18, 2015 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac4,R6sidentU & Ught.Gommercial HVAC Loads Elite Software Development,16c: Engineered Air LLC w Stan Pac RB 6810 Coventry Model Margate, FL 33063' , Fag0,2_ Project Report G,ene`raI Project Information Project Title: Stan Pac RB 6810 Coventry Model Designed By: Chris Wildroudt Project Date: 2-13-15 Client Name: Standard Pacific Homes Company Name: Engineered Air LLC CAC045860 Company Representative: Chris Wildroudt Company Address: 2520 N Andrews Ave Ext Company City: Pompano Beach, FL 33064 Company Phone: 954 974-7277 Company Fax: 954 973-1883 Company Comment: ..P. 9L� Nov<, e�',+'i :G-fie.- 3 #: F eRd L7e4igri Data _: new ag v� _ Reference City: Fort Pierce, Florida Building Orientation: House faces East Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 IOutdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 n/a n/a 70 n/a Summer: 90 75 50% 50% 73 46 Total Building Supply CFM: 2,119 CFM Per Square ft.: 0.661 Sq�are ft. of Room Area: 3,206 Square ft. Per Ton: 679 Volume (f?) of Cond. Space: 31,481 Builclin Loads...., 6. � x Total HeatingRequired Including Ventilation Air: 39,813 Btuh 39.81� q g 3 MBH Total Sensible Gain: 46,579 Btuh 82 % otal Latent Gain: 10,094 Btuh 18 % otal Cooling Required Including Ventilation Air: 56,673 Btuh 4.72 Tons (Based On Sensible + Latent) C:\Chris W Files from Share\Chris Elite Files\Stan Pac RB 6810 Coventry.rh9 Wednesday, February 18, 2015, 9:36 AM Rhvac Residential & Light Commercial HVAC Loads Engineered Air LLC �'„ �� �.. Elite Software Development; Inc. Stan Pac R6�6810 Coventry:Model . Margate;FL 33063 �Pdge.3 Total Building Summary Loads Component? Area ; "Sen Sen." Total Desch ,tion:` ° Quan Loss Gain_' r Gain:,. `Gain= Lo-E.Fixed Glass: Glazing -Low E Fixed Glass, u-value 49.4 554 0 693 693 0.4, SHGC 0.31 Lo-E operable: Glazing-Low-E Operable Glass, u-value 433.9 7,298 0 12,730 12,730 0.6, SHGC 0.31 Lo-E S G D: Glazing -Low E Sliding Glass Door, u-value 128 2,116 0 2,320 2,320 0.59, SHGC 0.32 Lo-E French Door: Glazing-Low-E French Door, u-value 48 1,034 0 850 850 0.77, SHGC 0.22 Lo-E operable: Glazing-Low-E Operable Glass, in 48 432 0 432 432 - partition wall, u-value 0.6, SHGC 0.31 11 J: Door -Metal - Fiberglass Core 24 403 0 403 403 11 D: Door -Wood - Solid Core 21.4 125 0 125 125 13A-4ocs: Wall -Block, board insulation only, R-4 board 1960.1 7,849 0 4,922 4,922 insulation, open core, siding finish 12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud 393.6 573 0 573 573 cavity, no board insulation, siding finish, wood studs 12B-Obw: Part -Frame, R-11 insulation in 2 x 4 stud 147.9 215 0 215 215 cavity, no board insulation, brick finish, wood studs 16D-30: Roof/Ceiling-Under Attic with Insulation on Attic 3205.8 2,872 0 3,310 3,310 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Tile, Slate or Concrete, R-30 insulation 22Aipl: Floor -Slab on grade, No edge insulation, no 248 6,868 0 0 0 insulation below floor, any floor cover, passive, light dry soil 20P-11: Floor -Over open crawl space or garage, 347 758 0 352 352 Passive, R-11 blanket insulation, any cover Subtotals for structure: 31,097 0 26,925 26,925 People: 8 2,400 2,400 4,800 Equipment: 4,000 4,000 8,000 Lighting: 400 1,364 1,364 tuctwork: 3,824 1,012 4,571 5,583 filtration: Winter CFM: 159, Summer CFM: 84 4,892 2,682 1,598 4,280 .Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 5,721 5,721 Total Building Load Totals: 39,813 10,094 46,579 56,673 Check.Figures�' Total Building Supply CFM: 2,119 CFM Per Square ft.: 0.661 Square ft. of Room Area: 3,206 Square ft. Per Ton: 679 Volume (ft') of Cond. Space: 31,481 Building -Loads 1Ka,y Total Heating Required Including Ventilation Air: 39,813 Btuh 39.813 MBH Total Sensible Gain: 46,579 Btuh 82 % Total Latent Gain: 10,094 Btuh 18 % Total Cooling Required Including Ventilation Air: 56,673 Btuh 4.72 Tons (Based On Sensible + Latent) Notes ° .. _� �_��......_..a.__.�._.�.. r Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. t C:\Chris W Files from Share\Chris Elite Files\Stan Pac RB 6810 Coventry.rh9 Wednesday, February 18, 2015, 9:36 AM " I'Engii ,Stan nee --Zone1-- 1 Main House 2345 31,795 413 16'6 534 33944 6046 1,544 1,544 ^ Duct Latent 598 $yobym 1 Main Trunk Size: 14x18 in. Velocity: 882 ft./min Loss per 100ft.: 0.097 in.wQ Net Required: 3.38 8496/16Y6 33.944 6.644 40.588 Actual: 3.88 75%/259& 34.875 11.825 46.500 Heating System Coolinq System Electric Resistance Standard Air Conditioner N1 10KVV CA13NA048°°^°(A.B) Indoor Model: FX4DN(B.F)049 8rand: 13 SEER PURON AC Efficiency: 096 14SEER Sound: O .0 Capacity: OBtuh 48.500Btuh Sensible Capacity: n/o 34.875Btuh LobentCopacity: n/a 11.625Btuh AHR{Reference No.: n/o 4542182 This byobam'sequipment was selected inaccordance with ACCAManual S. Manual Sequipment sizing data: SOD8:0DF.GOVVB:75F.VVOD8:42F.G|D8:73F.S|RH:5U96.WIDB:7OF.Sen. gain: 33.944Btuh.Lat. gain: G.G44Btuh. Sen. loss: 31.795Bbuh.Entering dg.coil DB:73F. Entering dg.coil VVB:GO.SF. Inbyringhtg.coil DB:70FC|g. coil TO:2OF,HbJ.coil TO:7UF.Req. dg.airflow: 1644CFM.Req. hb].airflow: 413CFM C:\ChhoVVFiles from Share\ChhoElite Fileo\8banPocR8G81UCovonby.nhQ Wednesday, February 1O.2015.B:3GAM C:\Chris W Files from Share\Chris Elite Files\Stan Pac RB 6810 Coventry.rh9 Wednesday, February 18, 2015, 9:36 AM