FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Standard Pacific RB 6810 Coventry Lot 30
Builder Name: Standard Pacific Homes
Street!-
Permit Office:
City, State, Zip: FL,
Permit Number:
wnStandard Pacific Homes
Jurisdiction:
De_iy1 Location: FL, Fort Pierce
1. New construction or existing New (From Plans)
9. Wall Types (3254.4 sqft.)
Insulation Area
1,jSingle family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 2643.50 ft2
b. Frame - Wood, Adjacent
R=11.0 610.93 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (3206.0 sqft.)
Insulation - Area
a. Under Attic (Vented)
R=38.0 3206.00 ft2
6. Conditioned floor area above grade (ft2) 3205.80004882
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. NIA
R= ft2
11. Ducts
R ft2
7. Windows(659.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: AC 1
6 320
a. U-Factor: Dbl, U=1.07 433.90 ft2
b. Sup: Attic, Ret: Attic, AH: AC 2
6 140
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=1.05 128.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.28
a. Central Unit
44.5 SEER:14.00
c. U-Factor: Dbl, U=1.00 49.44 ft2
b. Central Unit
17.8 SEER:14.00
SHGC: SHGC=0.32
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 48.00 ft2
a. Electric Heat Pump
45.0 HSPF:8.20
SHGC: other (see details)
b. Electric Heat Pump
17.6 HSPF:8.20
Area Weighted Average Overhang Depth: 5.528 ft.
Area Weighted Average SHGC: 0.292
14. Hot water systems
8. Floor`Types (3206.0 sqft.) Insulation Area
a..Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 3206.00 ft2
b. Conservation features
EF: 0.910
b. N/A' R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Gl�ss/Floor Area: 0.206Total Proposed Modified Loads: 42.62
GI ,s/Floor Area: 0.206
PASS
Total Standard Reference Loads: 54.90
1 hereby certify that the plans and specifications covered by
Review of the plans and
ST4?A
this calculation are in compliance with the Florida Energy
specifications covered by this
O�ZHE
Code. h Digitally signed by Chris Wildroudt
rI DN: cn=Chds Wildroudt, c=US,
- Chris
calculation indicates compliance
p
' `'��",
1 o=Engineered Air, LLC, ou=New
PREPARED BY: Construction Sales and
with the Florida Energy Code.
Before construction is completed
nrp�"�. •:;=: ; �t O
ngmeenng,
S ; • . d
DATE: ernail��hasw-engi�eeredai�l�.
W-i I d ro u "
this building will be inspected for
__
O -
.d# com
Date:2015.03.26 16:03:41-04'00'
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance,
Florida Statutes.
g`4
with the Florida Ener Code.
Oij y�,EIls�
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: 21
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with 403.2.2.1.1.
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
- Heat sys #1'�may be undersized. Size of 45.0 was increased to 51.0 for simulation. Please review the Manual J8 report.- Heat Sys #2
may be undersized. Size of 17.6 was increased to 17.6 for simulation. Please review the Manual J8 report.
3/26/2015 4:003 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6
PROJECT
Title:
Standard Pacific RB 6810 Cov
Bedrooms: 3
Address Type:
Lot Information
Building Type:
User
Conditioned Area: 3206
Lot #
30
Owner:
Standard Pacific Homes
Total Stories: 1
Block/Su bDivision:
Riverbend
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Standard Pacific Homes
Rotate Angle: 0
Street:
Permit Office:
Cross Ventilation:
County:
St. Lucie
Jurisdiction:
Whole House Fan:
City, State, Zip:
,
Family Type:
Single-family
FL,
New/tAsting:
New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location TMY Site
Zone 97.5 % 2.5 %
Winter
Summer Degree Days
Moisture
Range
FL, Fort Pierce FL_ST LUCIE_CO_INTL 2 39 90
70
73 722
62
Low
BLOCKS
Number
Name Area
Volume
1
Block1 2345
23450
2
Block2 860.7999
8031.26416
SPACES
Number
Name Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
AC 1 2345 23450 No 6
2
1 Yes
Yes
Yes
2 I
AC 2 860.8 8031.264 No 2
1
1 Yes
Yes
Yes
I
FLOORS
#
Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab
-On -Grade Edge Insulatio AC 1
248 ft 0
2345 ftz
0 0
1
2 Slab -On -Grade Edge Insulatio AC 2
124 ft 0
861 ft2
___
0 0
1
ROOF
/
Roof Gable Roof
Solar
SA Emitt
Emitt Deck
Pitch
#
Type Materials
Area Area Color
Absor.
Tested
Tested Insul.
(deg)
1
Hip Barrel the
3586 ftz 0 ftZ Medium
0.65
No 0.9
No 0
26.6
ATTIC
V
#
Type Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic Vented
300 3206 ftz
N N
\ 3/26/2015 4:00 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6
CEILING
#
Ceiling Type
Space
R-Value
Area Framing Frac
Truss Type
1
Under Attic (Vented)
AC 1
38
2345 ft2
0.11
Wood
2
Under Attic (Vented)
AC 2
38
861 ft2
0.11
Wood
•
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar
Below
�A-Ornt
To
WaILType
Space
R Value -Et -In
Ft -In Area R-Value-F-raction-Absor.-Grade./
1
E
Exterior
Concrete Block - Int Insul
AC 1
4.1
12.5
0
10 0 125 ft2
0.4
0 0.4
0
2
S
Exterior
Concrete Block - Int Insul
AC 1
4.1
73
0
10 0 730 ft2
0.4
0 0.4
0
3
W
Exterior
Concrete Block - Int Insul
AC 1
4.1
53
0
10 0 530 ft2
0.4
0 0.4
0
_ 4
N
Exterior
Concrete Block - Int Insul
AC 1
4.1
68
0
10 0 680 ft2
0.4
0 0.4
0
5
E
Garage
Frame - Wood
AC 1
11
38
0
10 0 380 ft2
0.4
0.4
0
6
N
Garage
Frame - Wood
AC 1
11
3.5
0
10 0 35 ft2
0.4
0.4
0
7
E
Garage
Frame - Wood
AC 2
11
21
0
9.33 0 195.9299
0.4
0 0.4
0
_ 8
S
Exterior
Concrete Block - Int Insul
AC 2
4.1
40
0
9.33 0 373.2000
0.4
0 0.4
0
_ 9
W
Exterior
Concrete Block - Int Insul
AC 2
4.1
22
0
9.33 0 205.2599
0.4
0 0.4
0
DOORS
I
#
Ornt
Door Type Space
Storms U-Value
Width
Height
Area
Ft
In
Ft In
1
E
Insulated
AC 1
None
0.6 3
0
8 0
24 ft2
I
2
E
Wood
AC 1
None
0.39 3
0
8 0 21.36000
I
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
#
Ornt ID
Frame Panes NFRC
U-Factor SHGC
Area Depth
Separation
Int Shade
Screening
1
E
1
Metal Low-E Double
Yes
1
0.32
13.35999 11 ft 0 in
2 ft 0 in
None
None
2
E
1
Metal Low-E Double
Yes
1.07
0.3
11.34000 1.5 ft 0 in
2 ft 0 in
None
None
3
S
2
Metal Low-E Double
Yes
1.07
0.3
32.340001.5 ft 0 in
2 ft 0 in
None
None
4
S
2
Metal Low-E Double
Yes
1
0.32
5.25 ft2 1.5 ft 0 in
2 ft 0 in
None
None
5
S
2
Metal Low-E Double
Yes
1.07
0.3
22.68000 1.5 ft 0 in
2 ft 0 in
None
None
6
S
2
Metal Low-E Double
Yes
1.07
0.3
8.812800 1.5 ft 0 in
2 ft 0 in
None
None
7
S
2
Metal Low-E Double
Yes
1.07
0.3
58.489191.5 ft 0 in
2 ft 0 in
None
None
8
S
2
Metal Low-E Double
Yes
1.07
0.3
19.49639 20 ft 0 in
2 ft 0 in
None
None
9
W
3
Metal Low-E Double
Yes
1.07
0.3
155.9711 1.5 ft 0 in
2 ft 0 in
None
None
10
W
3
Metal Low-E Double
Yes
1.05
0.28
128 ft2 11.5 ft 0 i
2 ft 0 in
None
None
11
N
4
Metal Low-E Double
Yes
1
0.32
8.9856001.5 ft 0 in
2 ft 0 in
None
None
12
N
4
Metal Low-E Double
Yes
1
0.32
21.84000 1.5 ft 0 in
2 ft 0 in
None
None
13
N
4
Metal Low-E Double
Yes
1.07
0.3
27.345601.5 ft 0 in
2 ft 0 in
None
None
14
N
4
Metal Low-E Double
Yes
1.07
0.3
16.170001.5 ft 0 in
2 ft 0 in
None
None
15
N
4
Metal Low-E Double
Yes
0.77
0.22
48 ft2 20 ft 0 in
2 ft 0 in
None
None
16
W
9
Metal Low-E Double
Yes
1.07
0.3
81.25 ft2 1.5 ft 0 in
0 ft 0 in
None
None
3/26/2015 4:00 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
800 ft2
800 ft2
100 ft loft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 WFrolehouse
Best Guess
0.000500
4204.4 230.81 434.08 0.3650 8.0132
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
= 1
2
Electric Heat Pump
Electric Heat Pump
None
None
HSPF: 8.2 45 kBtu/hr 1
HSPF: 8.2 17.6 kBtu/hr 2
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit
Central Unit
Split
Split
SEER: 14 44.5 kBtu/hr 1335 cfm 0.75 1
SEER: 14 17.8 kBtu/hr 534 cfm 0.75 2
sys#1
sys#2
I
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
i
I 1
I
Electric None
Garage
0.91 50 gal 60 gal 120 deg None
I
SOLAR HOT WATER SYSTEM
IFSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ft2
DUCTS
#
--- Supply --
Location R-Value Area
-- Return --- Air Percent
Location Area Leakage Type Handler CFM 25 Leakage QN RLF
HVAC #
Heat Cool
1
2
Attic 6 320 ft2
Attic 6 140 ft2
Attic
Attic
80 ft2 Default Leakage AC 1 (Default) (Default) %
60 ft2 Default Leakage AC 2 (Default) (Default) %
1 1
2 2
3/26/2015 4:00 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6
TEMPERATURES
Programable Thermostat:
Y
Ceiling Fans:
Coolin an
Feb
Mar
Apr
May
X Jun
Jul
Au
Se
Oct
Nov
Dec
Jan
Heating �)
Feb
MarAprMay
4 Jun
JXJJul
AuSeP
rj
f
OctjNov
X Dec
Ventin Jan
Feb
X Mar
[X
A r
Ma
[ Jun
Jul
Aug
Se [X
Oct
[X Nov
[ Dec
Thermostat Schedule: HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
3/26/2015 4:00 PM EnergyGauge@ USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: PERMIT #:
, FL,
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
-COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required.
Fireplaces: gasketed doors & outdoor combustion air. Must complete
envelope leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating
controls
and cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
/
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
lWater
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to =
R-2 + accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
J
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
/
3/26/2015 4:00 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 78
The lower the Energy Performance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2
7. Windows-
Description
a. U-Factor:
Dbl, U=1.07
SHGC:
SHGC=0.30
b U-Factor:
Dbl, U=1.05
SHGC:
SHGC=0.28
c. U-Factor:
Dbl, U=1.00
SHGC:
SHGC=0.32
d.i U-Factor:
other (see details)
SHGC:
other (see details)
Arga Weighted Average Overhang Depth:
Area Weighted Average SHGC:
„ FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1
2643.50 ft2
b. Frame - Wood, Adjacent
R=11.0
610.93 ft2
1
c. N/A
R=
ft2
3
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
No
a. Under Attic (Vented)
R=38.0
3206.00 ft2
3206
b. N/A
R=
ft2
Area
c. N/A
R=
ft2
433.90 ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: AC 1
6 320
b. Sup: Attic, Ret: Attic, AH: AC 2
6 140
128.00 ft2
12. Cooling systems
kBtu/hr
Efficiency
49.44 ft2
a. Central Unit
44.5
SEER:14.00
b. Central Unit
17.8
SEER:14.00
48.00 ft2
13. Heating systems
kBtu/hr
Efficiency
a. Electric Heat Pump
45.0
HSPF:8.20
5.528 ft.
b. Electric Heat Pump
17.6
HSPF:8.20
0.292
8. Floor Types Insulation Area
a. or
Edge Insulation R=0.0 3206.00 ft2
b. N/A R= ft2
c. N/A R= ft2
14. Hot water systems
Cap: 50 gallons
a. Electric
EF: 0.91
b. Conservation features
None
15. Credits Pstat
II
I ceftify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
w
Builder Signature: Date: 2A j 0
0 TIJE S?q�$
Address of New Home: 5?11 ?j M kAf ((Da 1-IL City/FL Zip: gS
c0D WET�O
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge@ USA - FlaRes2010 Section 405.4.1 Compliant Software
Stan Pac RB 68,10 Coventry Model
HVAC Load Calculations
for
Standard Pacific Homes
Prepared By:
Chris Wildroudt
Engineered Air LLC CACO45860
2520 N Andrews Ave Ext
Pompano Beach, FL 33064
954 974-7277
Wednesday, February 18, 2015
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
Rhvac4,R6sidentU & Ught.Gommercial HVAC Loads Elite Software Development,16c:
Engineered Air LLC w Stan Pac RB 6810 Coventry Model
Margate, FL 33063' , Fag0,2_
Project Report
G,ene`raI Project Information
Project Title:
Stan Pac RB 6810 Coventry Model
Designed By:
Chris Wildroudt
Project Date:
2-13-15
Client Name:
Standard Pacific Homes
Company Name:
Engineered Air LLC CAC045860
Company Representative:
Chris Wildroudt
Company Address:
2520 N Andrews Ave Ext
Company City:
Pompano Beach, FL 33064
Company Phone:
954 974-7277
Company Fax:
954 973-1883
Company Comment:
..P. 9L� Nov<, e�',+'i :G-fie.- 3 #: F eRd
L7e4igri Data _: new ag v� _
Reference City:
Fort Pierce, Florida
Building Orientation:
House faces East
Daily Temperature Range:
Medium
Latitude:
27 Degrees
Elevation:
25 ft.
Altitude Factor:
0.999
IOutdoor
Outdoor Outdoor Indoor
Indoor
Grains
Dry Bulb
Wet Bulb Rel.Hum Rel.Hum
Dry Bulb
Difference
Winter: 42
39.4 n/a n/a
70
n/a
Summer: 90
75 50% 50%
73
46
Total Building Supply CFM: 2,119 CFM Per Square ft.: 0.661
Sq�are ft. of Room Area: 3,206 Square ft. Per Ton: 679
Volume (f?) of Cond. Space: 31,481
Builclin Loads...., 6.
� x
Total HeatingRequired Including Ventilation Air: 39,813 Btuh 39.81�
q g 3 MBH
Total Sensible Gain: 46,579 Btuh 82 %
otal Latent Gain: 10,094 Btuh 18 %
otal Cooling Required Including Ventilation Air: 56,673 Btuh 4.72 Tons (Based On Sensible + Latent)
C:\Chris W Files from Share\Chris Elite Files\Stan Pac RB 6810 Coventry.rh9 Wednesday, February 18, 2015, 9:36 AM
Rhvac Residential & Light Commercial HVAC Loads
Engineered Air LLC �'„ ��
�..
Elite Software Development; Inc.
Stan Pac R6�6810 Coventry:Model .
Margate;FL 33063
�Pdge.3
Total Building Summary Loads
Component? Area ; "Sen
Sen."
Total
Desch ,tion:` °
Quan Loss
Gain_'
r Gain:,. `Gain=
Lo-E.Fixed Glass: Glazing -Low E Fixed Glass, u-value
49.4
554
0
693
693
0.4, SHGC 0.31
Lo-E operable: Glazing-Low-E Operable Glass, u-value
433.9
7,298
0
12,730
12,730
0.6, SHGC 0.31
Lo-E S G D: Glazing -Low E Sliding Glass Door, u-value
128
2,116
0
2,320
2,320
0.59, SHGC 0.32
Lo-E French Door: Glazing-Low-E French Door, u-value
48
1,034
0
850
850
0.77, SHGC 0.22
Lo-E operable: Glazing-Low-E Operable Glass, in
48
432
0
432
432
- partition wall, u-value 0.6, SHGC 0.31
11 J: Door -Metal - Fiberglass Core
24
403
0
403
403
11 D: Door -Wood - Solid Core
21.4
125
0
125
125
13A-4ocs: Wall -Block, board insulation only, R-4 board 1960.1
7,849
0
4,922
4,922
insulation, open core, siding finish
12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud
393.6
573
0
573
573
cavity, no board insulation, siding finish, wood studs
12B-Obw: Part -Frame, R-11 insulation in 2 x 4 stud
147.9
215
0
215
215
cavity, no board insulation, brick finish, wood studs
16D-30: Roof/Ceiling-Under Attic with Insulation on Attic 3205.8
2,872
0
3,310
3,310
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark Tile,
Slate or Concrete, R-30 insulation
22Aipl: Floor -Slab on grade, No edge insulation, no
248
6,868
0
0
0
insulation below floor, any floor cover, passive, light
dry soil
20P-11: Floor -Over open crawl space or garage,
347
758
0
352
352
Passive, R-11 blanket insulation, any cover
Subtotals for structure:
31,097
0
26,925
26,925
People:
8
2,400
2,400
4,800
Equipment:
4,000
4,000
8,000
Lighting:
400
1,364
1,364
tuctwork:
3,824
1,012
4,571
5,583
filtration: Winter CFM: 159, Summer CFM: 84
4,892
2,682
1,598
4,280
.Ventilation: Winter CFM: 0, Summer CFM: 0
0
0
0
0
AED Excursion:
0
0
5,721
5,721
Total Building Load Totals:
39,813
10,094
46,579
56,673
Check.Figures�'
Total Building Supply CFM: 2,119
CFM Per Square ft.:
0.661
Square ft. of Room Area: 3,206
Square
ft. Per Ton:
679
Volume (ft') of Cond. Space: 31,481
Building -Loads
1Ka,y
Total Heating Required Including Ventilation Air: 39,813
Btuh
39.813
MBH
Total Sensible Gain: 46,579
Btuh
82
%
Total Latent Gain: 10,094
Btuh
18
%
Total Cooling Required Including Ventilation Air: 56,673
Btuh
4.72
Tons (Based On Sensible
+ Latent)
Notes ° ..
_�
�_��......_..a.__.�._.�..
r
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version
2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads
according
to the manufacturer's
performance data
at
your design conditions.
t
C:\Chris W Files from Share\Chris Elite Files\Stan Pac RB 6810 Coventry.rh9 Wednesday, February 18, 2015, 9:36 AM
"
I'Engii ,Stan
nee
--Zone1--
1 Main House 2345 31,795 413 16'6 534 33944 6046 1,544 1,544
^ Duct Latent 598
$yobym 1 Main Trunk Size:
14x18
in.
Velocity:
882
ft./min
Loss per 100ft.:
0.097
in.wQ
Net Required:
3.38 8496/16Y6 33.944
6.644 40.588
Actual:
3.88 75%/259& 34.875
11.825 46.500
Heating System
Coolinq System
Electric Resistance
Standard Air Conditioner
N1
10KVV
CA13NA048°°^°(A.B)
Indoor Model:
FX4DN(B.F)049
8rand:
13 SEER PURON AC
Efficiency:
096
14SEER
Sound:
O
.0
Capacity:
OBtuh
48.500Btuh
Sensible Capacity:
n/o
34.875Btuh
LobentCopacity:
n/a
11.625Btuh
AHR{Reference No.:
n/o
4542182
This byobam'sequipment was selected
inaccordance with ACCAManual S.
Manual Sequipment sizing data:
SOD8:0DF.GOVVB:75F.VVOD8:42F.G|D8:73F.S|RH:5U96.WIDB:7OF.Sen. gain:
33.944Btuh.Lat. gain: G.G44Btuh.
Sen. loss: 31.795Bbuh.Entering dg.coil DB:73F.
Entering dg.coil VVB:GO.SF.
Inbyringhtg.coil DB:70FC|g. coil TO:2OF,HbJ.coil TO:7UF.Req. dg.airflow: 1644CFM.Req. hb].airflow: 413CFM
C:\ChhoVVFiles from Share\ChhoElite Fileo\8banPocR8G81UCovonby.nhQ Wednesday, February 1O.2015.B:3GAM
C:\Chris W Files from Share\Chris Elite Files\Stan Pac RB 6810 Coventry.rh9 Wednesday, February 18, 2015, 9:36 AM