HomeMy WebLinkAboutEvaluation Report Concrete Roof TilesRICEIVEL) OCT 27 20,T tst._Lucie itting Department County/ FL TRINITY I ERD EVALUATION REPORT Entegra Roof Tile, LLC 1289 NE 9th Avenue Okeechobee, FL 34972 lvo4 eGfdoe V 0 1 D EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report E39310.11.11-2-R3 FL7804-R8 Date of Issuance:11/02/2011 Revision 3 : 07/15/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 51h Edition (2014) Florida Building Code (non-HVHZ) sections noted herein. DESCRIPTION: Entegra Concrete Roof Tiles (non-HVHZ jurisdictions) LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors'and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 07/15/2015. This does not serve as an electronically signed document. Signed, sealed hardcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity) ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This Is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. �I I PJNITY I ERD ROOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Tiles Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.3.5, R905.3.5 Physical Properties ASTM C1492 2003 1507.3.7, R905.3.7 Attachment Requirements FRSA/TRI April 2012 (04-12) 2012 1711.2.1 Overturning Moment SSTD it 1997 3. REFERENCES: Enti Examination Reference Date PRI (TST5878) ASTM C1492 ESI-001-02-01 11/06/2006 PRI (TST5878) ASTM C1492 ESI-002-02-01 11/06/2006 PRI (TST5878) ASTM C1492 ESI-003-02-01 11/06/2006 PRI (TST5878) ASTM C1492 ESI-004-02-01 11/06/2006 PRI (TST5878) ASTM C1492 ESI-005-02-01 12/12/2006 ATL(TST3782) ASTM C1492 RT0615.01-11 06/28/2011 ATL(TST3782) ASTM C1492 RT0615.02-11 06/28/2011 ATL(TST3782) ASTM C1492 RT0615.03-11 06/28/2011 ATL(TST3782) ASTM C1492 RT0615.04-11 06/28/2011 ATL(TST3782) ASTM C1492 RT0615.05-11 06/28/2011 Tile Roof Institute SSTD 11 Membership Confirmation Current PRI (QUA9110) Quality Assurance Inspection Report 11/04/2015 4. PRODUcr DESCRIPTION: 4.1 BERMuoA FLIT and PLANTATION FLAT are ASTM C1492, Type III (low -profile) concrete roof tiles. Bermuda Flat Exterior Research and Design, I.I.C. certificate of Authorization #9503 Plantation Flat Evaluation Report E39310.11.11-2-R3 FL7804-R8 Revision 3: 7/15/2015 Page 2 of 4 4.2 4.3 BELLA HIGH "S" and ESTATE "S" are ASTM D1492, Type II (medium -profile) concrete roof tiles. Bella reign "S" GALENA SPANISH "S" are ASTM C1492, Type I (high -profile) concrete roof tiles. Galena Spanish ­S- 5. LIMITATIONS: I TRINITY I ERD tstate "b- 5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire classification is not part of this evaluation; refer to FBC Section 1505, Exception 2 or current Approved Roofing Materials Directory for fire rating of this product. 5.4 Underlayment shall be that approved by Entegra Roof Tile, which holds Florida Local or Statewide Product Approval for use with the roofing systems. The underlayment Product Approval shall specify allowable method(s) of tile installation (mechanical attachment, mortar -set and/or adhesive -set) for use with the specific underlayment. For mortar -set or adhesive -set the roofing applications, the underlayment Product Approval shall specify attachment methods for the underlayment system to resist wind uplift design loads in accordance with Table 1A of FRSA/TRI April 2012 (04-12). 5.5 Attachment: 5.5.1 For mechanically attached tiles, attachment for wind load resistance shall be in accordance with Table 3 of the FRSA/TRI April 2012 (04-12) to resist the Uplift Moment determined in Table 2A or 2B of FRSA/TRI April 2012 (04-12). 5.5.2 For mortar -set or adhesive -set tiles, attachment for wind load resistance shall be in accordance with FBC Section 1609.5.3 in conjunction with the mortar or adhesive manufacturer's Product Approval. 5.5.3 Hip and ridge tile shall be installed in accordance with FRSA/TRI April 2012 (04-12). For hip and ridge the installations atop hip and ridge metal, refer to the hip and ridge metal manufacturer's Product Approval (e.g., FL5374) or test report in accordance with SSTD 11 for allowable loads to resist those determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12). Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-2-R3 Certificate of Authorization 0503 FL7804-RB Revision 3: 7/15/2015 Page 3 of 4 1 TRINITY (ERD 5.7 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of FBC Section 1507.3, the FRSA/TRI Florida High Wind Concrete and Clay rile Installation Manual, 5th Edition and, for mortar -set or adhesive -set applications, the mortar or adhesive manufacturer's Product Approval. 7. LABELING: 7.1 Each unit shall bear the imprint or identifiable marking of the manufacturer's name or logo. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies, LLC. — QUA9110; (813) 621-5777 - END OF EVALUATION REPORT - Exterior Research and Design, U.C. Certificate of Authorization 49503 I Evaluation Report E39330.11.11-2-R3 FL7804-R8 Revision 3: 7/15/2015 Page 4 of 4