EVALUATION REPORT
Entegra Roof Tile, LLC
1289 NE 9th Avenue
Okeechobee, FL 34972
lvo4 eGfdoe
V 0 1 D
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report E39310.11.11-2-R3
FL7804-R8
Date of Issuance:11/02/2011
Revision 3 : 07/15/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 51h Edition (2014) Florida Building Code (non-HVHZ) sections noted
herein.
DESCRIPTION: Entegra Concrete Roof Tiles (non-HVHZ jurisdictions)
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors'and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 4.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 07/15/2015. This does not serve as an electronically signed
document. Signed, sealed hardcoples have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity) ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This Is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
�I I PJNITY I ERD
ROOFING SYSTEM EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Tiles
Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, Inc., have demonstrated compliance with
the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.3.5, R905.3.5
Physical Properties
ASTM C1492
2003
1507.3.7, R905.3.7
Attachment Requirements
FRSA/TRI April 2012 (04-12)
2012
1711.2.1
Overturning Moment
SSTD it
1997
3. REFERENCES:
Enti
Examination
Reference
Date
PRI (TST5878)
ASTM C1492
ESI-001-02-01
11/06/2006
PRI (TST5878)
ASTM C1492
ESI-002-02-01
11/06/2006
PRI (TST5878)
ASTM C1492
ESI-003-02-01
11/06/2006
PRI (TST5878)
ASTM C1492
ESI-004-02-01
11/06/2006
PRI (TST5878)
ASTM C1492
ESI-005-02-01
12/12/2006
ATL(TST3782)
ASTM C1492
RT0615.01-11
06/28/2011
ATL(TST3782)
ASTM C1492
RT0615.02-11
06/28/2011
ATL(TST3782)
ASTM C1492
RT0615.03-11
06/28/2011
ATL(TST3782)
ASTM C1492
RT0615.04-11
06/28/2011
ATL(TST3782)
ASTM C1492
RT0615.05-11
06/28/2011
Tile Roof Institute
SSTD 11
Membership Confirmation
Current
PRI (QUA9110)
Quality Assurance
Inspection Report
11/04/2015
4. PRODUcr DESCRIPTION:
4.1 BERMuoA FLIT and PLANTATION FLAT are ASTM C1492, Type III (low -profile) concrete roof tiles.
Bermuda Flat
Exterior Research and Design, I.I.C.
certificate of Authorization #9503
Plantation Flat
Evaluation Report E39310.11.11-2-R3
FL7804-R8
Revision 3: 7/15/2015
Page 2 of 4
4.2
4.3
BELLA HIGH "S" and ESTATE "S" are ASTM D1492, Type II (medium -profile) concrete roof tiles.
Bella reign "S"
GALENA SPANISH "S" are ASTM C1492, Type I (high -profile) concrete roof tiles.
Galena Spanish S-
5. LIMITATIONS:
I
TRINITY I ERD
tstate "b-
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in anyway, the Designer of Record
for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design
guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire classification is not part of this evaluation; refer to FBC Section 1505, Exception 2 or current Approved Roofing
Materials Directory for fire rating of this product.
5.4 Underlayment shall be that approved by Entegra Roof Tile, which holds Florida Local or Statewide Product Approval for
use with the roofing systems. The underlayment Product Approval shall specify allowable method(s) of tile installation
(mechanical attachment, mortar -set and/or adhesive -set) for use with the specific underlayment. For mortar -set or
adhesive -set the roofing applications, the underlayment Product Approval shall specify attachment methods for the
underlayment system to resist wind uplift design loads in accordance with Table 1A of FRSA/TRI April 2012 (04-12).
5.5 Attachment:
5.5.1 For mechanically attached tiles, attachment for wind load resistance shall be in accordance with Table 3 of the FRSA/TRI
April 2012 (04-12) to resist the Uplift Moment determined in Table 2A or 2B of FRSA/TRI April 2012 (04-12).
5.5.2 For mortar -set or adhesive -set tiles, attachment for wind load resistance shall be in accordance with FBC Section
1609.5.3 in conjunction with the mortar or adhesive manufacturer's Product Approval.
5.5.3 Hip and ridge tile shall be installed in accordance with FRSA/TRI April 2012 (04-12). For hip and ridge the installations
atop hip and ridge metal, refer to the hip and ridge metal manufacturer's Product Approval (e.g., FL5374) or test report
in accordance with SSTD 11 for allowable loads to resist those determined in accordance with Table 1A of FRSA/TRI April
2012 (04-12).
Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-2-R3
Certificate of Authorization 0503 FL7804-RB
Revision 3: 7/15/2015
Page 3 of 4
1
TRINITY (ERD
5.7 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and
F.A.C. Rule 61G20-3.
6. INSTALLATION:
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall comply with
manufacturer's current published instructions, but not less than the requirements of FBC Section 1507.3, the FRSA/TRI
Florida High Wind Concrete and Clay rile Installation Manual, 5th Edition and, for mortar -set or adhesive -set applications,
the mortar or adhesive manufacturer's Product Approval.
7. LABELING:
7.1 Each unit shall bear the imprint or identifiable marking of the manufacturer's name or logo. Tile lots shall be labeled in
accordance with the requirements of the Accredited Quality Assurance Agency noted herein.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
9. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements.
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies, LLC. — QUA9110; (813) 621-5777
- END OF EVALUATION REPORT -