HomeMy WebLinkAboutLetter- Tile Calculationsl� t To: CB Engineering Services, INC. Ea 1301 NE 7 St. #303 Hallandale, FL 33009 Phone: 954-534-1612 Email: cbbortes@gmail.com Whom it may concern Client: Te owner 2119 NW Greenbriar Lane Palm City, FL RECEIVED]. OCT 27 2017 Permitting Department St. Lucie County, FL Re: Miami -Dade County HVHZ Electronic Roof Permit Form Section E (Tile Calculations) Method 1 "Moment Based Tile Calculations per RAS 128" Location: 2119 NW Greenbriar Lane THESE P!._ANS AND -ALL PROPOSED WORK ARE SW)JECT TO ANY CMI SECTIONS Palm City, FL REQUIRE0 SY FIELD INVECT086 TfW MAY BE NBC ISSAI'1Y IN 01906N TO I, the undersigned, perform the Tile Calculation according with Miami Dade Cou"M Mk4b.V S1Q §A G9990, Method 1 "Moment Base Tile Calculation per RAS 128" RAS 128 shows in Table 2 for a roof mean height below 20 feet, for (Risk Category II and Exposure Category D- which is necessary to be considered for this location) the following value of the Minimum Design Wind Uplift Pressures: P1 in Roof Field Area = 51.4 psf P2 in Roof Perimeter Area = 86.2 psf P3 in Roof Corners Area = 129.7 psf Calculation Results Shows the Minimum Resisting Moment for the location mentioned above to be: (calculation sheet is attached to complete the report) RESULTS Mr1 in Roof Field Area = 3.83 ft-Ibf <_ NOA Mf 118.90 ft-Ibf PASS Mr2 in Roof Perimeter Area = 10.96 ft-Ibf <_ NOA Mf 118.90 ft-Ibf PASS Mr3 in Roof Corners Area = 19.88 ft-Ibf < NOA Mf 118.90 ft-Ibf PASS Installation Recommendation wM rIt — O-7 `T From NOA No.: 16-0112.07 (Expiration Date: 06/07/21) ST. LUCIE COUNTY Table 2 Aerodinamic Multipliers 0.205 cuft BUILDING DIVISION REVIEWED Table 3 Restoring Moments due to Mg = 6.71 ft-Ibf FOR COMPLI& JOE Gravity For Slope REVIEWED Y /C Table 4 Nail Attachement System Mf = 0.00 ft-Ibf DATE PLANS AND PERMIT (NO NAILS USED) MUST BE KEPT ON JOB OR NO Table 6 Adhesive Set System Mf = 118.90 ft-Ibf INSPECTION WILL BE MADE Total Mf = 118.90 ft-Ibf ACEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIMLITY OF THE Page 1 of 2 CONTRACTOR OF RE �!:� u „- L CB Engineering Services, INC. 1301 NE 7 St. #303 Hallandale, FL 33009 Ea Phone: 954-534-1612 Email: cbbortes@gmail.com If the Tiles will be attached on the Direct Deck (min 15/32” plywood) with Large paddy placement of 45 grams of 3M 2-Component Foam Roof Tile Adhesive AH-160, the tiles will meet the RAS 128, Current Miami Dade County HVHZ and 2014 Florida Building Code Requirements. Should you have any questions regarding the above, or if require additional information, please do not hesitate to contact this office. "Engineer seal is valid for pages 1 through 2" Sincerely, CB Engineering Services, INC. (CA # 30935) Signed by: Constantin Bortes M.S., P.E. Florida P.E. # 77915 Date: 10/19/2017 Page 2 of 2