Loading...
HomeMy WebLinkAboutGenerator Concrete PadAM* -RICAST GENERATOR CONCRETE F D GENERATOR TABLE: h t H NG.IH/ \ LE I�'�'I��GylOT/Y r_-- GENERATOR_ -_I Lu PAD THICKNESS ISOMETRIC VIEW PAD DIMENSIONS: CONCRETE PAD GENERATOR - = GENERATOR UNIT BY M SEPARATE SUBMITTAL 3 (SEE SCHEDULE FOR M MINIMUM WEIGHT REQUIRED) Ll 54"LENGTH PLAN -VIEW - CONCRETE PAD I _ ROAD MESH IASTERFIBER i` f ` ""'°L ;f MAC300 3' MIN 4:-':MIN. GROUNDS n,:. - .. 'l�.11 11 h GENERATOR MOUNTING CONFIGURATION: GENERATOR GENERATOR ATTACHMENT BASE OR SIMPSON A24 ANGLE BRACE W/ (4) *10 SS 316 SELF -DRILLING QCOEWS SRATOR TO GENERATOR %11 F- I I I GENERATOR (SEE CONCRETE PAD LD SCHEDULE FOR Lu DIMENSIONS & WEIGHT REQUIRED) 4" �--32" WIDTH + +- 54" LENGTH n b SIDE VIEW FRONT VIEW 14 0 (SEE (ON -GRADE APPLICATIONS -ONLY) AMERICAST wwwemeA•at;fiLnn_.c6m `-_- �1f �. FEDTAX0204 S2362 UCENSE099-M0157 SSW PAIMM Ave:• Fon PINX, FL 3e912 T,I. 772-97, 90 F- 77=4"4- 09 miL- leleetiLne.4ntN smmer ehaAndtf2601?rih"n.eon •' "% �;� '•� f• HVHZ OR NON-HVHZ RISK EXPOSURE (EXP) RISK EXPOSURE (EXP) RISK EXPOSURE (EXP) COUNTY I C D II C a.�=D �I`�.- i fillI,�I,�i l; .�. ! i;C--- �� _ II=D-C i! 1i P. BEACH 150 MPH 30.44 Psf 36.94 Psf 170 MPH 39.09 Psf 47.44'Psfe ,180 MPkI A3.83,Fsf-_-_ 53.19 Psf BROWARD 156 MPH 32.92 Psf 39.95 Psf 170 MPH 39.09 Psf 47.44 Psf ;180 MPH' g3:83 Psf"53'1'9 Fsf` MIAMI-DADE 165 MPH 36.83 Psf 44.69 Psf 175 MPH 41.43 Psf 50.28 Psf 186 MPH 46.80 Psf 56.80 Psf BRAND & MODEL CAPACITY W19TH LENGTH= HEIGHT WEIGHT! ALLOWABLE = '11 PRESSURE COMMENTS Generac 005871 & 005883 SO KW 25.00." ­ 48.00."-- --29.00"^ .,38TIbs/ 54.00 Psf EXP C 186 MPH & D 180 MPH Generac 005872 & 005884 14 KW 25 00 `' 48 001 i 29A0 " 439 IbSs l 56.80 Psf UP TO EXPOSURE D 186 MPH Generac 6459, 6461, 6462 16 KW 25.00'' z48.00"'-• -_29.00" ri513'Ib`s•, ``?56.80 Psf Generac 006721 16 KW 25 00" ` 48 00 " 29 00-� �s ,4,'48 Ibs" " 56.80 Psf 5 Generac 005873 & 005885 17 KW 25.00 " 48.00 " 29 00"' "• 55 Ibs 56.80 Psf Generac 005874 & 005886 17 KW 25:00�, 9.48:00 jii; . 29.00 1' i =421=Ibs.t :� 56:80 Psf Generac 005875 & 005887 20 KW 25 00 " 148 00 "� 29 00 ' 451 Ib°si 56:80 Psf Generac 006729 & 006730 20 KW 25.00 F 48 00 ;' - 29 00 �;'-= 516,&= H56.80 Psf Generac 006551 & 006552 22 KW 25.00 " 48.00 " 29.00 " 526 Ibs 56.80 Psf Kohler 14RES & 20RES 14-20 KW 26.00 " 48.0011 29.0011 500 Ibs 56.80 Psf GE 40323GE & 40324GE 13 KW 35.00 " 39.40 " 39.00 " 540 Ibs 49.50 Psf EXP C 186 MPH & D 170 MPH GE04038215KW 15KW 33.00" 48.00" 30.50" 4841bs 56.80Psf UP TO EXPOSURE D 186 MPH GE 04037817KW 17 KW 33.00 " 48.00 " 30.50 " 484 Ibs 56.80 Psf GE'40330GE & 40331GE 20 KW 33.00 " 48.00 " 30.50 " 600 Ibs 56.80 Psf Briggs & Stratton 040243-0 10 KW 31.00 " 32.00 " 34.00 " 4301bs 56.80 Psf Briggs & Stratton 040302-2 12 KW 33.75 " 50.00 " 31.60 " 507 Ibs 54.00 Psf EXP C 186 MPH & D 180 MPH Briggs & Stratton 040303-1 15 KW 33.75 " 49.00 " 31.60 " 562 Ibs 56.80 Psf UP TO EXPOSURE D 186 MPH Briggs &Stratton 040304-1 18 KW 33.75 " 49.00 " 31.60" 568lbs 56.80 Psf Briggs & Stratton 040305-1 20 KW 33.75 " 49.00 " 31.60 " 570 Ibs 56.80 Psf Generac 7035, 7036, 7037 16 KW 25.00 " 48.00 " 29.00 " 406 Ibs 47.44 Psf EXP C 186 MPH & D 170 MP_H. Generac.007038 & 007039 20 KW 25.00 " 48.00 " 29.00 " 448 Ibs 47.44 Psf Generac:007042 & 7043 22 KW 25.00 " 48.00 " 29.00 " 466 Ibs 47.44 Psf WIND DESIGN REOUIREMENTS- (BASED ON ASCE 7-10 & FLORIDA BUILDING CODE FIFTH EDITION (2014)) AT -GRADE SIGN METHOD ' ULTIMATE DESIGN WIND SPEED VUlt = 186 mph NOMINAL DESIGN WIND SPEED Vasd = 144 mph RISK CATEGORY = III INTERNAL PRESSURE COEF = N/A EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR Kd= 0.85 ENCLOSURE CATEGORY = N/A HEIGHT H = AT GROUND GUST EFFECT FACTOR = 0.85 PRESSURE AT HEIGHT H qh = 77.56 Ib/ft2 FORCE COEFFICIENT Cf = 1.44 ' WIND PRESSURE!: P = qh G Cf = 56.80 Ib/ft2 (ASD) L GENERAL NOTES ANCHOR TO PAD SCHEDULE SUBSTRATE DESCRIPTION CONCRETE: ()- TITEN HD (6PSI EN EQUIVALENT, MIN.) MIN 2-3/4" FULL EMBED 0 CONCRETE, 3" MIN EDGE DISTANCE, 6" MIN. SPACING TO ANY ADJACENT) NOTES: 1. ANCHOR QUANTITY PER LONG SIDE 2. EMBEDMENT AND EDGE DISTANCE ,-EXCLUDES-FINISHES,. IF \4.-ENSURE,P t~�-- -ANY ADJA j - S--I�INSTALLA --INSTAL-L- SEE GENERATOR SPE 3/8" SIMPSON TITEN HD, SEE ANCHOR SCHEDULE 2"x3"x%" GALV. STEEL - WASHER RUBBER VIBRATION PAD - VIBRATION PAD CONCRETE PAD - 6,000 PSI "A _._ =` LIGHTWEIGHT i D CONCRETE PA MIX CONCRETE (I( 6,0000 \ LIGHTWEIGHT ` MASTERFIBER MAC 100 J E'CONCRETE'MIX & ROAD MESH %" ' ' -- _.. L u G P ..s - FOAM CORE '--NOTES- - -1.' Y"DISTANCE DEPEND.ON-GENERATOR BASE LENGTH, NO LESS THAN 2". 2. X DISTANCE 3" FROM UNIT EDGE TO CLIP. 3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS THAN ANCHOR REQUIREMENTS MUM EDGE DISTANCE ANCHOR SCHEDULE. MUM SPACING TO IT"ANCHORS. UFACTURER'S N-INSTRUCTIONS TO 1. 2. 3. 4. 5. 6. 7. 8. 12 THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE 2014 FLORIDA BUILDING CODE (5th EDITION). REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON A JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. SITE -SPECIFIC LOAD REQUIREMENTS AS DETERMINED IN ACCORDANCE WITH THE APPLICABLE BUILDING -CODE SHALL BE"L-ESS THAN OR EQUAL TO THE DESIGWPRESSUR'E "ASD"CAPACITYALUES LISTED HEREIN FOR ANY-ASSEMBL-YAS iHOWN. /• DIMENSIONS ANDfWEIGHT OF'UNITS;SHA_LL CONFORM TO SPECIFICATIONS STATED>HEREIN:- UNITS MUST BE CENTERED ON PAD WITH OPPOSITE SIDES HAVING EQUAL CLEARANCE'A=MINIMUM.DISTANCE'FROM UNIT TO PAD EDGE IS SPECIFIED. i� !ij `.\ �• THE AREA UNDER" ONCERETE SLAB ON'GROUND'SHALL HAVE ALL VEGETATION, STUMPS ROOTS, AND FOREIGN MATERIALS REMOVED PRIOR TO INSTALLATION ON'COMPACTED SOIL AS VERIFIED BY OTHERS. , s. a ��, T-- ,i , n �-- RESISTANCE TO SLIDING OFiTHE�PAD ON THE GROUND IS NOT PART OF THIS"DOCUMENT AS SOILCHARACTERISTICS AND -PAD PLACEMENT VARIES ELECTRICAL GROUND -;-WHEN REQUIRED, T0 `B!Ez DESIGNED & INSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTING_CONTRACTOR:--- - - THIS DOCUMENT IS GENERIC-fAND.DOES NO-fPERTAINaTO ANY SPECIFIC PROJECT SITE, INFORMATION -CONTAINED' AEkEIN IS BASED ON CONTRACTOR -SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT -BE -HELD RESPONSIBLE OR LIABLE IN ANY WAY FO.R ERRONEOUS OR INACC URATE DATA OR MEASUREMENTS DIMENSIONS ARE SHOWN TO''ILLUSTRATE DESIGN FORCES ANDSOTHER DESIGN CRITERIA/THEY.,MAY VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. WORK SHALL --BE FIELD VERIFIED BY OTHERS PRIOR TO CONSTRUCTION.-ENGINEIERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK"UPON;DISCOVERYzOF ANY INACCURATE INFORMATION.PRIOR-TO_MODIFICATION OF 4- - EXISTING FIELD CONDITIONS,AND,FABRICATION AND INSTALLATION OF MAT_.ERIALS: ALTERATIONS O_R ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. ANK L. BENNARDO, P.E. 49 } "-3 cj201 IF OE000,! RMM P.LA` ANK L. BENNARDO, P.E. N Z O� .ice 0 O � p W 1+1 ,. y z I-M pq°� Wul LL�tLMXWib ZW 0 n(, r ~> U vex 3 U Q W rnIL�QW�w(7� 0-Cm o.Z.HH WW0�N Zw W O'q. Z@w O v � 0 (7 U) W a2 W O W w t0 � W J Q u 00Ln [j 1 Q O w m CD Elt U ' w o Z m � � a O O Lu F N O d (D Y •• 2: M N= Q In M L ti di w W 2 m En O Mo Z U M ¢m cW�2:a J LL ¢�@Es 5 -n Lua� O �s-s o o G13 a4� Y I1 m "L Z 3 O 0 z0a.nLL wD�� o cv o a�waa �o oozes Q 2 � W OO id U/tUtrrG COPYRIGHT ENGINEERING EXPRESS 17-3961.1 SCALE: NITS UNLESS NOTED OF 9