HomeMy WebLinkAboutEngineeringGeneral Notes A. CONCRETE & FOUNDATION DESIGN: 1. ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 PSI MINIMUM. 2. ALL CONCRY TE FILLED SUPPORTED SLABS SHALL BE 2500 PSI MINIMUM, 3 1/2" NOMINAL THICKNESS. 3. FBERMESH (3/4" PER CUBIC YARD MIN.) MEETING APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED IN LIEU OF WELDED WIRE MESH 4. ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERMESH. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE 60 (60 KSI MIN.) DEFORMED BARS, #3 BARS MAY BE GRADE 40 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SMALL BE 3000 PSI MIN., 2" MINIMUM. THICKNESS. 7. SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF. 8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING: OPC (PORTLAND CEMENT TYPE 1,- ASTM C 150). AGGREGATES - #6 STONE, ASTM C 33 SIZE NO. 67 LESS THAN 3/4". AIR ENTRAINING +/- 1 % - ASTXI C 260. WATER REDUCING AGENT - ASTM C 494. CLEAN POTABLE WATER. OTHER ADMIXTURES SHALL NOT BE PERMITTED. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 195. 10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1, 2, & 3 ALONG WITH HOT WEATHER CONDITIONS RECOMMENDATIONS. 11. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A MINIMUM OF 4" IN THICKNESS, VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, SPALLING OR OTHER DETERIORATION. B. MASONRY: 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2.A.LL MORTAR SHALL BE OF T1`PE M OR S. 3.A.LL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4.PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. C. ALUMINUM: 2. HEX BOLTS HAS TO BE ASTM A 325, PLATED WITH STANDARD FLAT WASHERS AND NUTS. 3. ALL CONCRETE SCREWS SHALL BE, SIMPSON, HILTI, RAWL, TAPCON, REDHEAD, DYNABOLT, PORTECT OR APPROVED EQUAL. 4. ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE HOT DIPPED GALVANIZED. 5. ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X BOLT DIAMETER INFO STRUCTURAL FRAMING (G=.42 MIN.). 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF THE BOLT OR SCREW. ALL LAG BOLTS AND SCREWS SHALL BE INSERTED IN PILOT HOLES BY TURNING AND UNDER NO CIRCUMSTANCES BY DRIVING WITH A HAMMER 7. ALL EXPANSION ANCHORS SHALL BE DESIGNED IN ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO MANUFACTURER. FASTENERS SHALL BE A MINIMUM OF SAE GRADE #5 OR BETTER ZINC PLATED. S. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 300 18-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, OR OTHERWISE NOTED ON PLANS. 9. ALL FASTENERS SHALL COMPLY WITH ASTM A1:53. 10.ALL CONNECTORS SHALL COMPLY WITH ASTM A653 CLASS G-185. 11. FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SHALL BE 3/4" AND NJINIMUM CENTER -TO -EDGE SHALL BE 1/2" UNLESS NOTED OTHER WISE. E. REFERENCE STANDARDS: ASTM E 119 ASTM E 1300 ASCE 7-10 AA ASM35, AND SPEC. FOR ALUMINUM PART 1-A. & 1-B ASTM C94 ASTM C150 ASTM C33 ASTM C260 ASTM C494 ASTM A615 ASTM A185 FLORIDA BUILDING CODE 5th EDITION (CHAPTERS 16,20 & 23). 2010 ALUMINUM DESIGN MANUAL 1. ALL STRUCTURAL ALUM NUM SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF 6005-T5 FOR ALLOY WITH A F. ABBREVIATIONS: MINIMUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS. THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED 2. WHERE KICK PLATES ARE USED A MINIMUM THICKNESS O:F TO REPRESENT ALL THOSE USED ON THESE DRAWINGS, BUT 0.024" SHALL APPLY. TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. 3. STRUCTURAL ALUMINUM DESIGN CONFORMS 1. TYP --TYPICAL TO "PART 1-A - SPECIFICATIONS FOR ALUMINUM 2. SIM -- SIMILAR STRUCTURES - ALLOWABLE STRESS 3. UON -- UNLESS OTHERWISE NOTED DESIGN' OR "PART 1-B - SPECIFICATIONS FOR ALUMINUM 4. CONT -- CONTINUOUS STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR. 5. VIF -- VERIFY IN FIELD DESIGN' OF THE ALUMINUM DESIGN MANUAL 2010 PREPARED BY THE ALUMINUM ASSOCIATION, INC. WASHINGTON D.C. 'THE G. RESPONSIBu reY: FLORIDA BUILDING CODE 5th EDITION ( CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 1. ALL SITE WORK SIit�L L BE PERFORMED BY A LICENSED 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR O TACT WITH CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING PRESSURE TREATED LUMBER PROVIDE DIELECTRIC CODES, LOCAL ORDINANCES, ETC. SEPARATION. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEENDRAWINGS, THAN #10 SMS 6" FROM THE E14DS AND 12" ON CENTER, IF FABRICATED ITEMS, OR ACTUAL FIELD USING #12 SPACING MAY BE 24" ON CENTER. CONDITIONS. 6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE. THEY 3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING SiJNROOM ROOM ADDITION ELEMENTS AS PRO`,'IDED BY THE "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND CONTRACTOR. SPEEDS EXCEED 75 MPH" .DECAL SHALL BE PLACED SO IT IS 4. ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED VISIBLE WHEN PANEL IS INSTALLED. ON INFORMATION PROVIDED BY THE CONTRACTOR AND 7. VXTWO.045" NON-STRUCTURAL MEMBERS SHALL BE MANUFACTURER. ATTACHED TO HOST WITH 1/4.0 X 1-3/4" EMBEDMENT & 24" 5• ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A O.C. MASONRY SCREW FOR CONCRETE & EQUIVALENT SIZE LICENSED P.E. IN ACCORDANCE WITH STANDARD WOOD SCREW WHEN IN WOOD & #IOX 1/2" EMBEDMENT SMS ENGINEERING PRACTICES. CAR TF.K SC'.RF.WS TN ATIM4TWTTr,4 W..MRFRc TVntrAT D. FASTENERS: I. ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 300 18-8, WITH STANDARD FLAT WASHER UNLESS MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD. H. MISCELLANEOUS: 1. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PREFAB HOME. IF THE EXISTING STRI CTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM MUST BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING BARRIER REQUIREMENTS OF THE FBC 5th EDITION R 4501.17 IN ITS ENTIRETY. 3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY CONTRACTOR 4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL HAVE EPDXY ADHESIVE TO CONCRETE. OR IF USING GROUT, ENSURE BONDING AGENT IS USED FIRST. 5. SCREENING MATERIAL SHALL BE 18X I4X0.013 OR EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED ON DRAWING S-2. 6. PLEASE NOTE: 2x2 (typ) DIAGONAL BRACING SHALL BE 2"X2"XO.055" MATERIAL, UNLESS OTHERWISE NOTED ON S-2. 7. ALL ALUMINUM SCREENED ENCLOSURES SHALL BE DESIGNED SPECIFICALLY FOR THE APPLICATION STATED IN RULE 61G20-1-002: TO REMOVE SCREEN PANELS IN THE EVENT OF FORECAST WINDS THAT EXCEED 751VIPH. LABELS SHALL BE PLACED ON CHAIR RAIL MEMBERS ON ALL SCREEN WALLS IN A LOCATION THAT CAN BE EASILY SEEN.AND FOR ALL PANELS ABOVE THE DESIGNED CHAIR RAIL ON ALL SCREEN WALLS SHALL BE CUT AS PRESCRIBED IN THE RULE AND THE CONTRACTOR SHALL, COMPLY WITH ALL THE REQUIREMENTS STATED IN RULE 61G20-1.002 AND SECTION 19 LAWS OF FLORIDA, 553.76, 553.77., ONLY APPLIES IF SHOWN ON PAGE 8-2 DRAWING PAGE. DESIGN DATA: 1. ULTIMATE DESIGN WIND SPEED Vult, (3 SECOND GUST): NOMINAL DESIGN WIND SPEED Vasd: 2. RISK CATEGORY: 3. WIND EXPOSURE: 4. WIND LOADS: 'SCREEN ROOF: N/A SCREEN WALLS: 31 PSF SOLID ROOF (SCREEN WALL): N/A RECEIlOED OCT 27 2017 Permitting Department St. Lucie County, FL 5. FACTOR APPLIED TO SCREEN WIND LOADS FOR 18X14,XO.013 OR EQUIVALENT DENSITY SCREEN MESH: N/A 6. FACTOR. APPLIED TO SCREEN WIND TOADS FOR ALLOWABLE STRESS DESIGN: 0.6 7. LIVE LOAD: 300 lb. VERTICAL DOWNLOAD ON PRIMARY SCREEN ENCLOSURE MEMBERS. 200 lb. VERTICAL DOWNLOAD ON SCREEN ENCLOSURE PUILLINS. 8. EXISTING SLAB /FOOTING SHALL MEET REQUIREMENTS FOR THE PROPOSED STRUCTURE.. 9. SCREEN ROOF TYPE: N/A 10. SOLIDROOF TYPE: N/A ALUNIINUM STRUCTURAL MEMBERS HOLLOW SECTIONS 2 x 2:-------------------------------- ---- 2" x 2" x 0.044" 2 x 3----------------------------------------2" x 3" x 0.050" 2 x 4:---------------------------------------2" x 4" x 0.050" 2 x 5:---------------------------------------2" x 5" x 0.050" OPEN BACK SECTIONS 1 x 2:----------------------------------------1" x 2" x 0.040„ 1 x 3-----------------------------------------1" x 3" x 0.045„ SNAP SECTIONS 2 x 4: ---------------------------2" x 4" x 0.045" Snap 2 x 4H :-------------------------------2" :K 4" x 0.060" Snap 2 x 5:--••------------------------------ 2":K 5" x 0.055" Snap SELF MATING (SMB 2 x 4 SNIB:------------------------ 2" x 4" x 0.044" x 0.100" 2 x 5 SNIB:------------------------ 2" x 5" x 0,050" x 0.118" 2 x 6 SNIB:------------------------ 2" x 6" x 0.050" x 0.120" 2 x 6 H SMB:---------------------2" x 6" x 0.072" x 0.224" 2 x 7 SNIB:------------------------ 2" x 7" x 0.057" x 0.120" 2 x 7 H SMB:---------------------2" x 7" x 0.072" x 0.224" 2 x 8 SNIB:------------------------ 2" x 8" x 0.072" x 0.224" 2 x 8 H SMB:--------------------- 2" x 8" x 0.082" x 0,306" 2 x 9 SNIB:------------------------ 2" x 9" x 0.072" x 0.224" 2 x 9 H SMB:---------------------2" x 9" x 0.072" x 0.306" 2 x 10 SMB:---------------------- 2" x 10" x 0.092" x 0.374" THIS PLAN AND FOUND IT TO BE IN COMPLIANCP WITH ASCE7.10, & FBC 5th EDITION. 0 4 o ° o STATE OF 6 `v 1^ESSIONALcLtSGIi I: EAL vidWSmith FI.E. FLORIDA LICENSE: 53608 Thomas L. Hanson RE, FLORIDA LICENSE: 38654 Mark R. Dunn P,E1. FLORIDA LICENSE: 73968 Joel Falardeau P.E. FLORIDA LICENSE: 70667 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph#(613)788-5314 Fax# 1-(866)824-7894 E-mail-erb@ ib cplans,co m W ebsite-Www.fbcplans, com C.O.A.429054 DATE: 10-12-2017 { DRAWN BY: TLK IREVISION: DATE: RO 1 RO 2 RO 3 RO 4 P R 0 _C MAT ADRIESS: C TRACTOR? NOTES S-1 THIS DOCJMENT SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT EXPRESSED WRITTEN PERMISSION OF TRAC DESIGN, LLC 20/20 SCREEN ix2 :4 p0 O O N N 2x2 2X2 1 1x2 1x2 ' 2'-0., 0" (tyP) ix2 lYi r G7 x N 2x2 2x2 1x2 ix2 (tyP) -0'— FRONT INFILL A.' es-3) 1x2 ix2 �? N x C1 N � w• :�. .. .,;� �? Cq N � i �- if •:�: fV ., � fV 4••''` to yx ;..�i• N 2x2 N 1x2 2x2 ;,.;: ', :: 2x2 2x2 1x2 1x2 1x2 ix2 4' ' -1 1 —4-3' - 04 (tyP) 12'-10'= REAR INFILL 1x2 1:4 O k Cc C N e- 4 ---5' — 0 "— I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN COMPLIANQ WITH ASCE7-10, & FBC 5th EDITION. �,���� a 4 O O � O p q STATE OF �4 € [ �y 'W15; ��° , d� fiL 64 L )avd`'U,�3iit�li P.E. 'LORIDA LICENSE: 53608 Fhomas L. Hanson P.E. "LORIDA LICENSE: 38654 . Mark R. Dunn P.E. "LORIDA LICENSE: 73968 Joel Falardeau P.E. "LORIDA LICENSE: 70667 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr, Unit 101 Zephyrhills, FL 33542 Ph#(813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplaiis.com W ebsite-wW w,fbcplans, com C.O.A: #29054 DATE: 10-12-2017 �— DRAWN BY: TLK REVISION: DATE: RO 1 RO 2 RO 3 RO 4 PROJECT ADDR8SS: COLASUNNO 2840 �ROCKSMITH' RD FT PIERCE, FL 34945 CONTRACTOR: JENSEN BEACH ALUM. 1720 NW FEDERAL HWY STUART, FL 34994 FLOOR PLAN S-2 THIS DOCJMENT SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT EXPRESSED WRITTEN PERMISSION OF TRAC DESIGN, LLC r_� HOST (4) #10 X 3/4" SMS FASTENING SECONDARY ANGLE TO COLUMN (TYP EACH SIDE) (B) -3/8" 0 CONCRETE SCREW ANCHOR INTO SECONDARY ANGLE(TYP EACH SIDE) (SEE TABLE) ANCHORSPA (MIN) (TYP)(SEETj Column Size 3/8" 0 Concrete Screw Anchor B Min. Spa 2x3 0 0 2x4 2x5 1 3 2x6 1 4 2x7 1 2x8 2 3 2x9 2 4 2x10 2 4.5 1/4" 0 CONCRETE SCREW 6" FROM GRIT & 6" FROM EA. END @ 18" O.C. IF WOOD -1/4" 0 X 3" LAG (4) #10 x 11/2" SMS INTO SCREW BOSS 2" x 2" HOLLOW SECTION GIRT H2 CHAIR RAILTO HOST DETAIL S'3 SCALE; NTS SECONDARY ANGLE MIN 0.125" THICK (NOT REQUIRED F013 2X3 PRIMARY 2" X 2" _ X 0.125" ANGLE (2) # 10 X 3/4" SMS FASTENING COLUMN TO PRIMARY ANGLE C Cf; (TYP EACH SIDE) X 2" BASE MEMBER MP EACH SIDE) (1) - 3/8" 0 CONCRETE SCREW G ANCHOR IN140 PRIMARY ANGLE AND @ 1/4" 0 CONCRETE 3" (MIN) SCREW ANCHOR @ 24" O.C. BETWEEN COLUMNS (TYP EACH SIDE) NOTES: 1. NUMBER OF ANCHORS "B" IS EACH SIDE INTO THE SECONDARY ANGLE AND DOES NOT INCLUDE THE ANCHOR INTO THE 1X2. 2. MINIMUM EMBEDMENT OF ANCHORS INTO CONCRETE FOOTING SHALL BE 2-3/4" ATAT ALL UPRIGHT LOCATIONS. ALL SCREW LENGTHS AT UPRIGHT CONNECTIONS SHALL BE OF SUFFICIENT LENGTH FOR REQUIRED EMBEDMENT INTO CONCRETE FOOTING WHEN A PAVER DECK IS PRESENT. 3. CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON THOSE LISTED ON S-1, D. FASTENERS, OTHER BRAND & TYPE SHALL BE APPROVED BY ENGINEER. 4, 2X3W/1X2 CORNER POST SHALL REQUIRE SAME BASE CONNECTIONS AS 2X4 SHOWN IN TABLE. 5. IF FOR AN IN -FILL, TOP OF COLUMN CONNECTION SIMILAR IF CONCRETE LINTEL. IF WOOD LINTEL SUBSTITUTE 1/4" 0 X 3" LAG SCREW FOR 3/8"0 LDT FOR BOTH PRIMARY & SECONDARY ANGLES. Ci 2" x 3" OR LARGER UPRIGHT TO CONCRETE W 0 PAVER DETAILS S_3 SCALE: NTS I HEREBY CERTIFY THAT I HAVE REVIEWED THIS PLAN AND FOUND IT TO BE IN COMPLIANCE WITH ASCE7-10, & FBC 5th EDITION. t llgl'uee* 1/4"0 x 2"-1/2 MASONRY ANCHORS' y@ (7 IF WOOD SUBSTITUTE IDENTICAL WOOD SCREW OR LAG 6" FROM 4 $ TOP & BOTTOM & @ 24" O.C. 6 o "12"OPEN BACK �+ °o e �, 60 8-TATF_ OF 2"12"10,062 ANGLE W/ (4) #12X3/4"SMS INTO 1"X2"OPEN BACK & (1) 1/4"0 x 2 1/2" EMBEDDED MASONRY ANCHOR & @ 6" FROM END -IF WOOD SUBSTITUTE IDENTICAL SIZED LAG l-9."X2"OPEN BACK H 1 OPEN BACK TO HOST STRUCTURE DETAIL S_3 SCALE: NTS OPTION #1 (4)410 x 1 t/a" SMS_ INTO SCREW BOSSES = ===--= _7 == 2"12" OR 2"13" PURLIN OR GIRT OPTION #2 RECEIVING CHANNEL OR ANGLE EA. SIDE (typ) (.0625" THICKNESS) (2) #10x 3/4" SMS (typ) EA LEG) (TOTAL 8 SCREWS EA, CONNECTION) NOTES: 1. OPEN BACK 1"X2 "X0,045" PERIMETER MEMBER SHALL BE ATTACHED TO HOST STRUCTURE W/ 1/4"0 X 2-1/2" CONCRETE ANCHOR FOR CONCRETE ANCHOR FOR CONCRETE CONNECTION OR 1/4"X 2-1/2" LAG SCREW FOR WOOD @ 6" FROM CORNER & @ 24" O.C. MAX. 2. CHAIR RAIL SHALL BE ATTACHED W. 0.062" INTERNAL OR EXTERNAL RECEIVING CHANNEL W/ (1) 1/4"0 X 2-1/2" CONCRETE ANCHOR FOR CONCRETE CONNECTION OR 1/4" 0 X 2-1/2" LAG SCREW FOR WOOD TO HOST & (2) 1#10 X 3/4" SMS EA. LEG TO CHAIR RAIL. H CHAIR RAIL CONNECTION S-3 SC ALE: N.T.S. Davidiffl M11W P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P. FLORIDA LICENSE: 38654 Mark R. Dunn P.E. FLORIDA LICENSE: 73968 Joel Falardeau P.E. FLORIDA LICENSE: 70667 FBC Plans & Engineerinj Services, Inc. 6272 AbbottStation Dr, Unit 101 Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@ fbcplans. co m. Website-www, fbcplans.co m C,O.A.-# 29054 DATE: 10-12-2017 DRAWN BY: TLK REVISION: DATE: RO 1 RO 2 IRO 3 RO 4 PROJECT ADDRESS: COLASUNNO 2840 BROCKSMITH RD FT PIERCE, FL 34945 CONTRACTOR: JENSEN BEACH ALUM. 1720 NW FEDERAL HWY STUART, FL 34994 LANAI DETAILS S-3 THIS DOOJMENT SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT PERMISSION OF TRAC DESIGN, LLC