Product Evaluation Report
CENTURY METAL ROOFING SUPPLY, LLC.
Min. 29 Ga. Tuff Rib Roof Panel over 1x4 Wood Purlins over 15132" Plywood
THESE PLANS AND ALL PROPOSED WORK
ARE SU&JECT TO AMYY CO,MMECTIONS
REOURED OY RUO IDJ3K.-C'f0#ls DIRT
MAY BE NECENk-tY IN ODDER TA
COMPLY WITd 4 A'PWC-AAW 000901 .j
Florida Product Approval # 13738.2 R2
Florida Building Code 2014
Per Rule 61G20-3
Method: 1-D
�1 7)D-0 671fl-� �6
ST. LUCIE COUNTY
BUILDING DIVISION
REVIEWED
FOR COM7 E
REVIEWED BY
DATE
PLANS AND PERMIT
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
Category: Roofing
Subcategory: Metal Roofing
Compliance Method: 61G20-3.005(1)(d)
NON HVHZ
Product Manufacturer:
Century Metal Roofing Supply, LLC.
6851 Douglas Highway
Millwood, GA 31552
Engineer Evaluator:
Terrence E. Wolfe, P.E. # 44923
Florida Evaluation ANE ID: 1920
Validator:
Locke Bowden, P.E., FL #49704
9450 Alysbury Place
Montgomery, AL 36117
Contents:
Evaluation Report Pages 1-4
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILITY OF THE
WRAMROF RE=
CEN�F<�,��
w ! � No. Pas
PR t ."�
_ L i _ -/�
- -._ -•-• � a • STATE OF : �
saw orrm� �� AN • , • Vti��•
FL# 13738.2 R2 April 7, 2015
f
LJ 19530 Ramblewood Drive
Humble,TX 77338
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2014, Sections 1504.3.2, 1504.7.
Product Description: Tuff Rib Roof Panel, Minimum 29 Ga. Steel, 36" coverage, through fastened roof
panel over 1x4 wood purlins over one layer of asphalt shingles (optional) over
min. 15/32" APA Plywood decking. Non -Structural Application.
Panel Material/Standards: Material: Min. 29 Ga. Steel conforming to Florida Building Code 2014 Section
1507.4.3. Paint finish optional.
Yield Strength: Min. 80.0 ksi
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2014, Section 1507.4.3.
Panel Dimension(s): Thickness: 0.015" min.
Width: 36" maximum coverage
Rib Height: %" major rib at 9" O.C.
Panel Rollformer: MRS Metal Rollforming Systems
Panel Fastener: #9-15 x 1-1/2" HWH Woodgrip with sealing washing or approved equal
Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4
Substrate Description: 1x4 No. 2 SYP wood purlins over maximum one layer of asphalt shingles/felt
paper (optional) over min. 15/32" thick APA rated plywood over supports at
maximum 24" O.C. The 1x4 wood purlins shall be attached through the plywood
into every rafter (max. 24" O.C.) with (2) 8x3" deck screws (min. 15/8"
penetration into wood rafter). Design of 1x4 wood purlins, plywood and
plywood supports are outside the scope of this evaluation. Substrate must be
designed in accordance w/ Florida Building Code 2014.
Design Uplift Pressures:
FL# 13738.2 R2
Table "A"
Maximum Total Uplift Design Pressure:
78t5<p3f
101.0 psf
Fastener Pattern:
V6"-3"-6"-3"-6"-3"-6"
Fastener Spacing:
�`24�O.C:
24" O.C.
*Design Pressure includes a Safety Factor = 2.0.
Goi
a • STATE OF : a!
April 7, 2015
i
LJ 19530 .Ramblewood Drive IJ
Humble; rX 77338
Code Compliance: The product described herein has demonstrated compliance with
The Florida Building Code 2014, Section 1504.3.2, 1504.7.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2014, as relates to Rule 61G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
■ UL 580-06 - Test for Uplift Resistance of Roof Assemblies
■ UL 1897-04 - Uplift Test for Roof Covering Systems
■ FM 4471-92 - Foot Traffic Resistance Test
Reference Data:
1. UL 580-94/ 1897-98 Uplift Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 389-0065T-10.
2. FM 4471-95, Section 5.4 Foot Traffic Resistance Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 389-0065T-10.
3. Certificate of Independence
By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc.
(FBC Organization # ANE ID: 1920)
Test Standard Equivalency:
1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard.
3. The FM 4471-95, Foot Traffic Resistance test standard is equivalent to the
FM 4471-92, Foot Traffic Resistance test standard.
Quality Assurance Entity:
The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Minimum Slope Range:
Minimum Slope shall comply with Florida Building Code 2014, including Section
1507.4.2 and in accordance with Manufacturers recommendations. For slopes
less than 3:12, lap sealant must be used in the panel side laps.
Installation:
Install per manufacturer's recommended details.
%,`��tt�stetttti�i
C E N
. A
No.444 l �
l
A * �•+�
a ' STATE OF : a
`0.c:. FZ o R 19 4'. ' 2A'
sw/ orra�u �� FS • , V� ,��
FL# 13738.2 R2 April 7, 2015
Force Eiigin.eel ing & Testing Ilic.
1.9530 .Ramblewood Drive
Humble,`1"Y 77338
Underlayment: Per Manufacturer's installation guidelines in compliance with Florida Building
Code 2014.
Roof Panel Fire Classification: Fire classification is not part of this acceptance.
Shear Diaphragm: Shear diaphragm values are outside the scope of this report.
Design Procedure: Based on the dimensions of the structure, appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2014 for roof cladding
wind loads. These component wind loads for roof cladding are compared to the
allowable pressure listed above. The design professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover. Support framing must be in compliance with Florida Building Code 2014
Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading.
FL# 13738.2 R2
% E C E' E.
��,���V • C E NSF
l
` No. aas
J
STATE OF ;
o� . FL `
April 7, 2015
4,
MIN. 29 GA. TUFF RIB PANEL p VER UC- WV-=OUD�PURLINS
TYPE I FASTENER PA[(ERN AT 24" O.0
eamxum Me sm
>k I�ia°flsn"�W-3:1i°PE5
#9-15 x 1 1/2" HWH WOODGRIP W/ SEALING WASHER
L1x4. VOOD_PURLINS-@,.24' O.C, ATTACHED TO WOOD RAFTERS (24. O.C. MAX)
W/ (2) 8x3' DECK SCREWS @ 24' O.C. INTO WOOD RAFTERS
(MIN, 1 5/8' PENETRATION INTO WOOD RAFTER)
ONE LAYER OF ASPHALT SHINGLES/FELT (OPTIONAL) OVER 15/32' PLYWOOD
TYPE 2 FASTENER PATTERN AT 24" O.C.
6' 3' 6' 3' 6' 3' 6' 3' O%ff*A w TAPE say
Fat 115E I Slp'ES
LM TIBN 3:12
#9-15 x 1 1/2" HWH WOODGRIP W/ SEALING WASHER
VIx4 WOOD PURLINS @ 24' O.C. ATTACHED TO WOOD RAFTERS (24' O.C. MAX)
W/ (2) 8x3' DECK SCREWS @ 24' O.C. INTO WOOD RAFTERS
(MINA 1 5/8' PENETRATION INTO WOOD•RAFTER)
ONE LAYER OF ASPHALT SHINGLES/FELT (OPTIONAL) OVER 15/32' PLYWOOD
di''tr
C.O.A..
•pax;
April 6, 2015