Loading...
HomeMy WebLinkAboutProduct Evaluation ReportL R C E 4 V E D OCT 2 7 2017 rF(o.)rc,e.t��;.ineeriri; PERM11-TANG & Testi.nf; I.lic. 5t. Lucie County, FL 19530 Ramblewood Drive Flumhle, l.Y 77338 r Product Evaluation Report CENTURY METAL ROOFING SUPPLY, LLC. Min. 29 Ga. Tuff Rib Roof Panel over 1x4 Wood Purlins over 15132" Plywood THESE PLANS AND ALL PROPOSED WORK ARE SU&JECT TO AMYY CO,MMECTIONS REOURED OY RUO IDJ3K.-C'f0#ls DIRT MAY BE NECENk-tY IN ODDER TA COMPLY WITd 4 A'PWC-AAW 000901 .j Florida Product Approval # 13738.2 R2 Florida Building Code 2014 Per Rule 61G20-3 Method: 1-D �1 7)D-0 671fl-� �6 ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COM7 E REVIEWED BY DATE PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE Category: Roofing Subcategory: Metal Roofing Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Century Metal Roofing Supply, LLC. 6851 Douglas Highway Millwood, GA 31552 Engineer Evaluator: Terrence E. Wolfe, P.E. # 44923 Florida Evaluation ANE ID: 1920 Validator: Locke Bowden, P.E., FL #49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1-4 CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE WRAMROF RE= CEN�F<�,�� w ! � No. Pas PR t ."� _ L i _ -/� - -._ -•-• � a • STATE OF : � saw orrm� �� AN • , • Vti��• FL# 13738.2 R2 April 7, 2015 f LJ 19530 Ramblewood Drive Humble,TX 77338 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2, 1504.7. Product Description: Tuff Rib Roof Panel, Minimum 29 Ga. Steel, 36" coverage, through fastened roof panel over 1x4 wood purlins over one layer of asphalt shingles (optional) over min. 15/32" APA Plywood decking. Non -Structural Application. Panel Material/Standards: Material: Min. 29 Ga. Steel conforming to Florida Building Code 2014 Section 1507.4.3. Paint finish optional. Yield Strength: Min. 80.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2014, Section 1507.4.3. Panel Dimension(s): Thickness: 0.015" min. Width: 36" maximum coverage Rib Height: %" major rib at 9" O.C. Panel Rollformer: MRS Metal Rollforming Systems Panel Fastener: #9-15 x 1-1/2" HWH Woodgrip with sealing washing or approved equal Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4 Substrate Description: 1x4 No. 2 SYP wood purlins over maximum one layer of asphalt shingles/felt paper (optional) over min. 15/32" thick APA rated plywood over supports at maximum 24" O.C. The 1x4 wood purlins shall be attached through the plywood into every rafter (max. 24" O.C.) with (2) 8x3" deck screws (min. 15/8" penetration into wood rafter). Design of 1x4 wood purlins, plywood and plywood supports are outside the scope of this evaluation. Substrate must be designed in accordance w/ Florida Building Code 2014. Design Uplift Pressures: FL# 13738.2 R2 Table "A" Maximum Total Uplift Design Pressure: 78t5<p3f 101.0 psf Fastener Pattern: V6"-3"-6"-3"-6"-3"-6" Fastener Spacing: �`24�O.C: 24" O.C. *Design Pressure includes a Safety Factor = 2.0. Goi a • STATE OF : a! April 7, 2015 i LJ 19530 .Ramblewood Drive IJ Humble; rX 77338 Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2014, Section 1504.3.2, 1504.7. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2014, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: ■ UL 580-06 - Test for Uplift Resistance of Roof Assemblies ■ UL 1897-04 - Uplift Test for Roof Covering Systems ■ FM 4471-92 - Foot Traffic Resistance Test Reference Data: 1. UL 580-94/ 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 389-0065T-10. 2. FM 4471-95, Section 5.4 Foot Traffic Resistance Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 389-0065T-10. 3. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc. (FBC Organization # ANE ID: 1920) Test Standard Equivalency: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. 3. The FM 4471-95, Foot Traffic Resistance test standard is equivalent to the FM 4471-92, Foot Traffic Resistance test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2014, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per manufacturer's recommended details. %,`��tt�stetttti�i C E N . A No.444 l � l A * �•+� a ' STATE OF : a `0.c:. FZ o R 19 4'. ' 2A' sw/ orra�u �� FS • , V� ,�� FL# 13738.2 R2 April 7, 2015 Force Eiigin.eel ing & Testing Ilic. 1.9530 .Ramblewood Drive Humble,`1"Y 77338 Underlayment: Per Manufacturer's installation guidelines in compliance with Florida Building Code 2014. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2014 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2014 Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading. FL# 13738.2 R2 % E C E' E. ��,���V • C E NSF l ` No. aas J STATE OF ; o� . FL ` April 7, 2015 4, MIN. 29 GA. TUFF RIB PANEL p VER UC- WV-=OUD�PURLINS TYPE I FASTENER PA[(ERN AT 24" O.0 eamxum Me sm >k I�ia°flsn"�W-3:1i°PE5 #9-15 x 1 1/2" HWH WOODGRIP W/ SEALING WASHER L1x4. VOOD_PURLINS-@,.24' O.C, ATTACHED TO WOOD RAFTERS (24. O.C. MAX) W/ (2) 8x3' DECK SCREWS @ 24' O.C. INTO WOOD RAFTERS (MIN, 1 5/8' PENETRATION INTO WOOD RAFTER) ONE LAYER OF ASPHALT SHINGLES/FELT (OPTIONAL) OVER 15/32' PLYWOOD TYPE 2 FASTENER PATTERN AT 24" O.C. 6' 3' 6' 3' 6' 3' 6' 3' O%ff*A w TAPE say Fat 115E I Slp'ES LM TIBN 3:12 #9-15 x 1 1/2" HWH WOODGRIP W/ SEALING WASHER VIx4 WOOD PURLINS @ 24' O.C. ATTACHED TO WOOD RAFTERS (24' O.C. MAX) W/ (2) 8x3' DECK SCREWS @ 24' O.C. INTO WOOD RAFTERS (MINA 1 5/8' PENETRATION INTO WOOD•RAFTER) ONE LAYER OF ASPHALT SHINGLES/FELT (OPTIONAL) OVER 15/32' PLYWOOD di''tr C.O.A.. •pax; April 6, 2015