HomeMy WebLinkAboutGenerator Concrete Padrn AMERICAST GENERATOR CONCRETE PAD N' \ \ roTy �GENERATOR__I_p 1 \ I PAD THICKNESS v a 'laI Ca I i ISOMETRIC VIEW PAD DIMENSIONS: GENERATOR TABLE: CONCRETE PAD GENERATOR - Fa = GENERATOR UNIT BY o SEPARATE SUBMITTAL 3 (SEE SCHEDULE FOR M MINIMUM WEIGHT REQUIRED) �T } 54" LENGTH W V&W s' CONCRETE PAD ( ROAD MESH MASTERFIBER MAC100 3 MIN' `4'MIN 16L , =�3 -.,' C `"`�-"GENERATOR MOUNTING CONFIGURATION: (ON -GRADE APPLICATIONS ONLY) AMERICAST - mmimIN.AMIDRIQA:' =TAXi1U-US2W LIMNSE099-M50110 5393 Maalo AK Fort New%FL 30n 1 TLL m-9n-ID.A Faz 773.164-0309 -� /' ,ji uiL•-r1t9Q�tsM{l91t1u.MmaeeM1�.lndfQ091�wheoe HVHZ OR NON-HVHZ , RISK EXPOSURE (EXP) RISK EXPOSURE (EXP) RISK EXPOSURE (EXP) COUNTY I C D I I C �D )(, 1 �III;ryIV r FFc P. BEACH 150 MPH 30.44 Psf 36.94 Psf 170 MPH 39.09 Psf 47.44 Psf 180 MPH 43 83 Psf 53,19 Psf BROWARD 156 MPH 32.92 Psf 39.95 Psf 170 MPH 39.09 Psf 47.44 Psf _1861MOH W 83 Psf 53 19'Fsf_r MIAMI-DADE 165 MPH 36.83 Psf 44.69 Psf 175 MPH 41.43 Psf 50.28 Psf 186 MPH 46.80 Psf 56.80 Psf BRAND &MODEL CAPACITY WIDTH_. LENGTH = HEIR HT� HT I_: 'WE f '� P LLOWABLE �J%PRESSURE COMMENTS Generac 005871 & 005883 10 KW 25.ob " ` 48 00:"_. 29.00 "~, 30413sX 54.00 Psf EXP C 186 MPH & D 180 MPH Generac 005872 & 005884 14 KW 25.00 "`.I 48 00-�: 11 td " 434 Ibs<: 56.80 Psf UP TO EXPOSURE D 186 MPH Generac 6459, 6461, 6462 16 KW 25.00,'` ' 48.00"`- 5134b3.; �.56.80 Psf Generac 006721 16 KW 25.00" 48 00 " 29 00 _" 448 Ibs �56.80 Psf Generac 005873 & 005885 17 KW 2.5.00 " 48.00 "� 29.00,.";- �455 Ibs 56.80 Psf Generac 005874 & 005886 17 KW 25:00, 48.00 � � h 29,00- L.=-421 Ibs,, 56:80,Psf Generac 005875 & 005887 20 KW 25.00"' � 48 00 29 00 Y 451 Ibs) ° 56:80°Psf Generac 006729 & 006730 20 KW 25.00 it 48 00 ,= 29 00 r� 516;Ibs T 56.80 Psf Generac 006551 & 006552 22 KW 25.00 " 48.00 " 29.00" 526 Ibs 56.80 Psf Kohler 14RES & 20RES 14-20 KW 26.00 " 48.00 " 29.00 " 500 Ibs 56.80 Psf GE 40323GE & 40324GE 13 KW 35.00 " 39.40 " 39.00 " 540 Ibs 49.50 Psf EXP C 186 MPH & D 170 MPH GE 040382 15KW 15 KW 33.00 " 48.00 " 30.50 " 484 Ibs 56.80 Psf UP TO EXPOSURE D 186 MPH GE 04037817KW 17 KW 33.00 " 48.00 " 30.50 " 484 Ibs 56.80 Psf GE'40330GE & 40331GE 20 KW 33.00 " 48.00 " 30.50 " 600 Ibs 56.80 Psf Erriggs & Stratton 040243-0 10 KW 31.00 " 32.00 " 34.00 " 430 Ibs 56.80 Psf Briggs & Stratton 040302-2 gg 12 KW 33.75 " 50.00 " 31.60 " 507 Ibs 54.00 Psf EXP PH D C186M & 180MPH Briggs & Stratton 040303-1 15 KW 33.75 " 49.00 " 31.60 " 562 Ibs 56.80 Psf UP TO EXPOSURE D 186 MPH Briggs & Stratton 040304-1 18 KW 33.75 " 49.00 " 31.60 " 568 Ibs 56.80 Psf Briggs & Stratton 040305-1 20 KW 33.75 " 49.00 " 31.60 " 570 Ibs 56.80 Psf Generac 7035, 7036, 7037 16 KW 25.00 " 48.00 " 29.00 " 406 Ibs 47.44 Psf EXP C 186 MPH & D 170 MPH Generac.0.07038 & 007039 20 KW 25.00 " 48.00 " 29.00 " 448 Ibs 47.44 Psf G�Oen'e�ac:007042 & 7043 22 KW 25.00 " 48.00 " 29.011 0 " 466 Ibs 47.44 Psf GENERATOR ATTACHMENT BASE OR SIMPSON A24 ANGLE BRACE W/ (4) #10 SS 316 SELF -DRILLING SCREWS �t)T_F_ Q TT-F - F I- GENERATOR (SEE CONCRETE PAD w(DSCHEDULEFOR DIMENSIONS & WEIGHT REQUIRED) 4" -32" WIDTH 54" LENGTH b SIDE VIEW FRONT VIEW ao v 0 (SEE THI( GENERATOR WIND DESIGN REQUIREMENTS - (BASED ON ASCE 7-10 & FLORIDA BUILDING CODE FIFTH EDITION (2014)) AT -GRADE SIGN METHOD ' ULTIMATE DESIGN WIND SPEED, Vult = 186 mph NOMINAL DESIGN WIND SPEED iVasd = 144 mph RISK CATEGORY = III INTERNAL PRESSURE COEF = N/A EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR Kd= 0.85 ENCLOSURE CATEGORY = N/A HEIGHT H = AT GROUND GUST EFFECT FACTOR = 0.85 PRESSURE AT HEIGHT H qh = 77.56 Ib/ft2 FORCE COEFFICIENT Cf = 1.44 ' WIND PRESSURE:: P = qh G Cf = 56.80 Ib/ft2 (ASD) L- - - - - - - - - - - - - - - - - - - - - - ANCHOR TO PAD SCHEDULE SUBSTRATE DESCRIPTION CONCRETE: (2)-3/8"0 TITEN HD (6000 PSI ORE QUIVALENT, MIN.) 2-3/4' FULL EMBED O CONCRETE, 3" MIN EDGE DISTANCE, 6" MIN. SPACING TO ANY ADJACENT ANCHOR. NOTES: 1. ANCHOR QUANTITY PER LONG SIDE 2. EMBEDMENT AND EDGE DISTANCE �` EXCLUDES _FINISHES, IF APPLICABLE: 3 ENSURE MINIMUM,E6 E DISTANCE AS'NOTED`IN ANCHOR SCHEDULE. 4 ENSURE MINIMUM SPACING TO .�AANY ADJACENT ANCHORS. 5 IFOLLOW MANUFACTURER'S INSTALLATIONANSTRUCTIONS TO Il j GENERATOR ATTACHM,,, T BASE, _ VARIES WITH�MODEL SEE'GENERATOR SPECS " 3/e' SIMPSON TITEN HD, SEE ANCHOR SCHEDULE 2"x3"x3/8" GALV. STEEL WASHER RUBBER VIBRATION PAD J CONCRETE PAD 6,000 PSI LIGHTWEIGHT X CONCRETE MIX CONCRETE;PAD 6 000 PSI J LIGHTWEIGHT \ MASTERFIBER MAC 100 CONCRETUMIX I T °+ 1 & ROAD MESH NOTES F) FOAM CORE - -z - _ .1... Y DISTANCE DEPEND.OWGENERATOR BASE LENGTH, NO LESS THAN 211. 2. X DISTANCE 3" FROM UNIT EDGE TO CLIP. 3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS THAN ANCHOR REQUIREMENTS in 2"--t GENERAL NOTES 1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE 2014 FLORIDA BUILDING CODE (Sth EDITION). 2. REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON A JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. SITE -SPECIFIC LOAD REQUIREMENTS AS DETERMINED IN -ACCORDANCE WITH THE APPLICABLE BUILDING -CODE SH4L1_BE-LESS THAN OR EQUAL TO THE DESIGN-PRESSURE-'ASD°. CAPACITY VA{LUES LISTED HEREIN FOR ANY -ASSEMBLY AS SHOWN /•' 3. DIMENSIONS ANDsWEIGHT OF UNITSISHALL�CONFORM TO SPECIFICATIONS STATED -HEREIN:• \! , 4. UNITS MUST BE CENTERNED OPAD-WITH OPPOSITE SIDES HAVING EQUAL CLEARANCE. A MINIMUM DISTANCE FROM UNIT TO PAD EDGE IS SPECIFIED. `--- 5. THE AREA UNDER CONCERETE SLAB ON GROUND"'SHALLLLHAVE ALL VEGETATION, STUMPS ROOTS, AND FOREIGN MATERIALS REMOVED PRIOR TO INSTALLATION'ON"COMPACTED SOIL AS VERIFIED BY OTHERS. a r (­ � 6. RESISTANCE TO SLIDING ORTHEIPAD ONtTHEIGROUND ISF1 PART OF THIS 'DOCUME_NT AS SOILCHARACTERISTICS AND PAD PLACEMENT VARIES' �_'' 7. ELECTRICAL GROUND; WHEN REQUIRED TO'BE`DESIGNED & INSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. 8. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 9. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. 10. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTING CONTRACTOR: 11. THIS DOCUMENT IS GENERIC AND: DOES NOT PERTAIN TO ANY SPECIFIC PROJECT SITE_IINFORMATION CONTAINED�HEREIN IS BASED ON CONTRACTOR:SUPPLIED; DATA AND MEASUREMENTS. ENGINEERING EXPRESSYSHALL NOT -BE -HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS DIMENSIONS ARE SHOWN TO`ILLUSTRATE DESIGN FORCES A ,OTHER DESIGN CRITERIA rTHEY�MAY VARY SLIGHTLY, BUT.MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. WORK SHAL SE FIELD VERIFIED BY OTHERS PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORWUPON DISCOVERY -OF ANY,I `h INACCURATE INFORMATIOW�'PRIOR T6A(i6IFIICATION OF. EXISTING FIELD CONDITIONS AND; FABRICATION AND, ATr: INSTALLATION OF MERIALS. AAT LTERIONS OR ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. 12. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. VK L. BENNARDO, P.E. 0046549 201 L. BENNARDO, P.E. U 0 N Z o � � F �O LLI M MYE F M 4in0 WH oUl U in W� LLUIXNit rz OWU Zar t ~>Q hula LJ � Q LU L.0 0 1i OLca NozwZ W1W ID�zw Ori JwU �w U MOZ LL C7 U) W a=w LU ui ri w U) a " 00 1-1 0 J O7S w N �-4 U , o z f--1 �w� ma O_ C7Lu F Wwa°i a H ry a(D p O O Sz Z = rr)In rrn W LL c w w Go a N O Mo Z U �gcD goo w �+ y In ca (D a: a < m 0 J LL a Lu - a ; � a��w ° o o Z k z Y S U m c2 zo LL W�o w02mU ozzoU -j' O O (L' w o �UEE aoZ,�� aw o o r�zy�o zp� Y w K U 10wGoGE� K Z j 0 �E zIQ COPYRIGHT ENGINEERING EXPRESS 17-3961.1 SCALE: NTS UNLESS NOTED OF