Loading...
HomeMy WebLinkAboutRevisionf OFFICE USE ONLY: DATE FILED: REVISION FEE: L S • ISO V PERMIT # ' O " L0 (0� RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATIO LOCATION/SITETr I I . ADDRESS: 6507 DORIS DRIVE FORT PIERCE DETAILED DESCRIPTION OF PROJECT REVISIONS: REVISED PANEL PLACEMENT FROM SHED TO MAIN HOUSE CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CVC056656 BUSINESS NAME: LSCI INC QUALIFIERS NAME: RAYMOND MEAD ADDRESS: 4625 E BAY DR # 305 CITY: CLEARWATER STATE: FL PHONE (DAYTIME): 561-651-9725 OWNER/BUILDER INFORMATION: NAME: ARNOLD BONSALL ADDRESS: 6507 DORIS DR CITY: FT PIERCE PHONE (DAYTIME: 772-429-2817 STATE: FL ARCHITECT/ENGINEER INFORMATION: NAME: RI. CASTILLO ADDRESS: 2381 CRESDT RIDGE COURT CITY: SANFORD PHONE (DAYTIME): 407-474-9181 SLCCC: 9123109 Revised 06130117 ST. LUCIE CO CERT. #: ZIP: 33764 FAX: 727-683-9854 PAx: STATE: FL FAX: �` � y`Y LL' [ ` � •� ZIP: 34951 ZIP: 32771 .PROJECT DESCRIPTION: 1SX290 HANWHA Q.PEAK BLK-G4.1 290 (290W) MODULES 'ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES SYSTEM SIZE: 5.22 kW DC STC ARRAY AREA #1: 323.64 SQ FT. EQUIPMENT SUMMARY 18 HANWHA Q.PEAK BLK-G4.1 290 (290W) MODULES 01 SB 3.8-1SP-US-40 INVERTER A-00 GOVERNING CODES: FLORIDA ELECTRIC CODE, 5TH EDITION 2014 EDITION (FEC) FLORIDA RESIDENTIAL CODE, 5TH EDITION 2014 (FRC) FLORIDA PLUMBING CODE, 5TH EDITION 2014 (FPC) FLORIDA BUILDING CODE, 5TH EDITION 2014 EDITION (FBC) FLORIDA MECHANICAL CODE, 5TH EDITION 2014 (FMC) ARTICLE 690, NEC 2011 CODE BOOK NOTE TO INSTALLER: FIELD ADJUSTMENTS CAN BE MADE TO THE LAYOUT OF THE ARRAY 66'-8" PA50 ROBLES BLVD, (E) GATE (TYP.) � f A R)f PLOT PLAN WITH ROOF PLAN SCALE: 1/16" =1'-0" LID 14" 71'-10" (V 0 N T— N W E s (E) MAIN DISTRIBUTION PANEL ROOF #1 (18) HANWHA Q.PEAK BLK-G4.1 290 (290W) MODULES PROJECT SITE 2 HOUSE PHOTO A 00 SCALE: NTS`►. REVISION ei PROJECT SITE SHEETINDEX A-00 PLOT PLAN & VICINITY MAP A-01 SYMBOLS & SYSTEM DESCRIPTION S-01 ROOF PLAN & MODULES S-02 STRUCTURAL ATTACHMENT DETAILS S-02.1 STRUCTURAL ATTACHMENT DETAILS E-01 ELECTRICAL LINE DIAGRAM E-02 WIRING CALCULATIONS E-03 SYSTEM LABELING P-01 PV WATTS DS-01 DATA SHEET DS-02 DATA SHEET DS-03 DATA SHEET ST. LUC;E COUjgTTY BUILDING D-1VISION REVIEWED FOR COWIr REVIEar}1gD Sy DATJE PLANS ,00 FERI U I ST BE Imo: i O, JOB OR NO P SPECTION WILL BE Nt4DE. Coquina Ave ri iJn) Citrus Park Blvd Coquina Ave r r ' c 'Robles Blvd a 6507 Doris Drive Santa Clare Blvd a Citrus Park Blvd RC ENGINEERING, LLC COAs28345 2381 CREST RIDGE COURT SANFORD, FL 32771 TEL 407-074.8161ERMOCRATES E. CASTILLO -FL PE 52550 EViSIONS.. DE�RIPTION .-_.DA'4 REV AS PER INSTALLER 12/0W017 AA PROJECT DEVELOPER �r,itttlti/��r,, CIO iLe Signature %V 1 U- : • o :y• U) .,* .. P�O,``to PROJECT NAME U Z (3) LU M 0 J LL Lij Lu- 00 0W Q oa � � Z O m SHEET NAME PLOT PLAN & VICINITY MAP SHEET SIZE ANSI B 1111 X 17" 3 VICINITY MAP SHEETNUMBER A-00 SCALE: NTS A-00 Symbols: Sheet where Section.... X section is located x-xx Detail ID Letter Elevation ........... X Sheet where x-xx section is located Detail ID Letter Detail x """""""" x-xx Sheet where section is located Detail ID Letter Detail ............... x Area to be enlarged (Enlarged Plan) x" Sheet where section is located Keyed Notes .......... O Keyed note designation on applicable sheet Ground Terminal ..... 0 Grounding Point/rod.... 1w Solar Panel ......... or 00 odule with Source Circuit number Combiner Box .......... CB DC Disconnect .......... DCD Main Distribution M D PI Panel...................... Fuse ...................... Overcurrent Breaker.. —� Inverter .................... Transformer ............. F* Automatic ............... : AT5 Transfer Switch '-----' Abbreviations: AC Alternating Current APPROX Approximate AWG American Wire Gauge CB Combiner Box DC Direct Current DCD Direct Current Disconnect DISC Disconnect (E) Existing EL Elevation EQ Equal JB Junction Box MCB Main Combiner Box MFR Manufacturer MIN Minimum MISC Miscellaneous (N) New OCPD OverCurrent Protection Device POCC Point Of Common Coupling PV Photovoltaic SF Squarefoot/feet STC Standard Test Conditions TBD To Be Determined TYP Typical VIF Verify In Field WP Weather Proof System Description This system is a grid -tied, PV system, with PV generation consisting of 18 HANWHA Q.PEAK BLK-G4.1 290 (290M MODULES with a combined STC rated do output power of 5,220W. The modules are connected into 01 SB 3.8-1SP-US-40 INVERTER. The inverter has electronic maximum power point tracking to maximize energy captured by the PV modules. The inverter also has an internal ground fault detection and interruption device that is set to disconnect the array in the event that a ground fault that exceeds one ampere should occur. The inverter has DC and AC disconnect integrated system and labels are provided as required by the National Electric Code PV Modules Microinverters—► Junction Box Point of O Utility Connection Utility Meter Figure 1: PV System Block Diagram When the sun is shining, power from the PV array is fed into the inverter, where it is converted from DC to AC. The inverter output is then used to contribute to the power requirements of the occupancy. If PV power meets the requirements of the loads of the occupancy, any remaining PV power is sold back to the utility. When utility power is available, but PV power is not available, building loads are supplied by the utility. The inverter meets the requirements of IEEE 1547 and UL 1741. This means that if it detects a loss of utility power, it will automatically disconnect from the utility. When utility voltage is restored, the inverter automatically reconnects to the utility grid after verifying utility voltage and frequency stability. On a day with average Florida sunshine, this system outputs 18.16 kWh per day on site. RC ENGINEERING, LLC COA#28345 2381 CREST RIDGE COURT SANFORD, FL 32771 TEL 407-4748181ERMOCRATESE. CASTILLO- FL PE 54500 REVISIONS DESCRIPTION DATE REV PROJECT D OPER o+ ao 0 v ignatu 'tea ONP N * cc W � Q 0 Z Z F_ p R . ,e PROJECT NAME W U �- Z rn LV M J CO CO) LL W �w oQ 0 J W Q L0 CO � Z O o m SHEET NAME SYMBOLS & SYSTEM DESCRIPTION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER A-01 -MODULE TYPE. DIMENSIONS & WEIGHT NUMBER OF MODULES =18 MODULES MODULE TYPE = HANWHA Q.PEAK BLK-G4.1 290 (290W) MODULES MODULE WEIGHT = 41.45 LBS / 18.8 KG. MODULE DIMENSIONS = 65.7" x 39.4" =17.98 SF UNIT WEIGHT OF ARRAY = 2.31 PSF ARRAY & ROOF AREA CALC'S (ROOF #1) ARRAY AREA = 323.64 SQ. FT. ROOF FACE AREA = 915.00 SQ. FT. 323.64 / 915.00 = 35.37% OF ROOF FACE AREA COVERED BY ARRAY DESCRIPTION (ROOF #1) ROOF TYPE - ASPHALT SHINGLE ROOF ROOF TILT - 22.6° ROOF AZIMUTH - 91° / TRUSSES SIZE - 2"X4" @ 24" O.C. ROOF #1 (18) HANWHA Q.PEAK BLK-G4.1 290 (2904 MODULES R/ z 0 11 ARI 1 ROOF PLAN & MODULES S-01 SCALE: 3/32" =1'-0" 1A/IA1n 7nA1G a irVO N N GENERAL INSTALLATION PLAN NOTES: w B 1) DRAWINGS SHOWN MAY NOT REFLECT FIELD CONDITIONS. CONTRACTOR TO FIELD VERIFY CONDITIONS PRIOR TO INSTALLATION. s 2) CONTRACTOR MAY LOCATE PV MODULES TO DIFFERENT LOCATION THAN SHOWN, BUT SHALL NOT PLACE PV MODULES IN WIND ZONE 3. UNLESS NOTED OTHERWISE IN NOTE 3 BELOW. 3) ROOF ATTACHMENTS TO SYP TRUSSES SHALL BE INSTALLED AS SHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE: WIND ZONE 3 (TYP.) (E) MAIN DISTRIBUTION PANEL WIND ZONE 1: 4'-0" O.C. (E) UTILITY METER WIND ZONE 2: 4'-0" O.C. (N) AC DISCONNECT WIND ZONE 3: 2'-0" O.0 (IF REQUIRED) SEE SHEET S-02.1 FOR SUPPORTING CALCULATIONS. (N) PV METER (IF REQUIRED) 4) EXISTING RESIDENTIAL BUILDING IS ASSUMED TO BE (N) SB 3.8-1SP-US-40 INVERTER ASPHALT SHINGLE ROOF WITH MEAN ROOF HEIGHT LESS THAN 3/4" PVC CONDUIT RUN 30 FT AND SYP 2X4 WOOD ROOF TRUSSES SPACED 24" O.C. (N) JUNCTION BOX EXISTING ROOF SLOPE FOR SOLAR SYSTEM RETROFIT IS ASSUMED TO BE BETWEEN 7 TO 27 DEGREES. CONTRACTOR TO FIELD VERIFY AND SHALL REPORT TO THE ENGINEER IF ANY DISCREPANCIES EXIST BETWEEN PLANS AND IN FIELD 1�0 CONDITIONS. „ . NOTE TO INSTALLER: = ti ROOF #1 FIELD ADJUSTMENTS CAN BE MADE TO THE LAYOUT OF THE TILT - 22.6° / (D I AZIM.-91° � 31+9.4"1 (32) PV ROOF ATTACHMENT U @ 48" O.C. MAX (N) UNIRAC RAIL (TYP.) WIND ZONE 1 (TYP.) L1 HANWHA Q.PEAK WIND ZONE 3 (TYP.) v BLK-G4.1 290 (290" MODULES WIND ZONE 2 (TYP.) WIND ZONE 3 (TYP.) LEGEND JB -JUNCTION BOX INV -INVERTER oc - INTEGRATED DC DISCONNECT sLD - SOLAR LOAD CENTER PM -PRODUCTION METER MDP - MAIN DISTRIBUTION PANEL O -VENT, ATTIC FAN (ROOF OBSTRUCTION) O - PV ROOF ATTACHMENT -RAFTERS ---- - CONDUIT CB - COMBINER BOX RC ENGINEERING, LLC COA@28m 2381 CREST RIDGE COURT SANFORD,FL32771 TEL• 407474-9181ERMOCRATES E. CASTILLO • FL PE M90 REVISIONS DESCRIPTION DATE REV AS PER INSTALLER 121082017 AA PROJECT DEVELOPER co uj t Signa ILL. 1•• . , ` i • , rn 0to w LO :Z- �0= PROJECT NAME U T_ Z a) W It Q M 0 _I _ (/i LL. W OV a Q t� CO 0 0 LL m SHEET NAME ROOF PLAN & MODULES SHEET SIZE ANSI B 11" X 17" SHEET NUMBER S-01 GENERAL INSTALLATION NOTES FOR FLORIDA BUILDING CODE COMPLIANCE 1. APPLICABLE CODE: 2014 FLORIDA BUILDING CODE (5TH EDITION) & ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES. 2. LAG SCREW DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER 2014 FLORIDA BUILDING CODE (STH EDITION) REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A SOUTHER YELLOW PINE (SYP) RESIDENTIAL WOOD ROOF TRUSS AS EMBEDMENT MATERIAL. 3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIENTIAL ROOFS, CONSIDERING FROM A 7° TO A MAXIMUM 27° (2/12 TO A MAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. CONTRACTOR TO FIELD VERIFY THAT MEAN ROOF HEIGHT DOES NOT EXCEED 30'-0". 4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511, AND IS THE RESPONSIBILITY OF THE CONTRACTOR TO PILOT DRILL AND FILL ALL HOLES. 5. ALL DISSIMILAR MATERIALS SHALL BE SEPARATED WITH NEOPRENE WASHERS, PADS, ETC OR SIMILAR. 6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESS OTHERWISE NOTED. 7. ALL LAG SCREW SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED. 8. ALL SOLAR RAILING AND MODULES SHALL BE INSTALLED PER MANUFACTURER INSTRUCTIONS. 9. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2014 FLORIDA BUILDING CODE (5TH EDITION) OR LOCAL GOVERNING CODE. WOOD ---� SHEATHING TYP. e" -16 HEX CAP ST STL BOLT AND ST STLSERRATED FLANGE NUT TYP. ELI ALUMINUM L-FOOT V 5116" ST STL LAG SCREW TYP. REFER TO SHEET S-03 FOR THREADED EMBEDMENT DEPTH REQUIRED IN WOOD TRUSS. END -CLAMP W/J" - 20 HEX CAP ST STL BOLT AND ST STL SERRATED FLANGE -NUT TYP. END -CLAMP SIZE VARIES. 3RD RAIL LOCATION TYP. (IF REQUIRED - SEE STRUCTURAL PLAN ON SHEET S-01 �' ASPHALT SHINGLE i' ROOFING TYP. is i UNIRAC RAIL (TYP.) WOOD ROOF TRUSS TYP. CENTER -CLAMP WITH t" - 20 HEX CAP ST STL BOLT AND (1) ST STL SERRATED FLANGE NUT TYP. TYPICAL MODULE ARRAY ISOMETRIC SCALE: N.T.S SPACING OF FLANGE CONNECTION SHALL BE FASTENED TO STRUCTURAL WOOD ROOF SUPPORT TYP. 2 PLCS. PER SIDE OF MODULE AND BE CONNECTED <25%OF MODULE LENGTH. USE ANTI -SEIZE AND TIGHTEN TO TORQUE PER MANUF. INSTRUCTIONS 60 CELL PHOTOVOLTAIC MODULE TYP. ALUMINUM ASPHALT L-FOOT TYP SHINGLE EVERY ROOF ROOFING TYP. PENETRATION t@-16HEXCAPST STL BOLT AND ST STLSERRATED FLANGE NUT TYP. UNIRAC RAIL ' CENTER -CLAMP WITH 20 HEX CAP ST STL BOLT / / WOO SHEATHING WOOD ROOF TRUSS TYP. AND (1) ST STL SERRATED FLANGE NUT TYP. 5116" ST STL LAG SCREW. SEE SCH FOR EMBED. DEPTH REQ. TYP. EACH ' L-FOOT TYPICAL PV SOLAR RAIL MID CONNECTION DETAIL _e END -CLAMP G1y{TyP. MODULE 20 HEX C c 25% 6" TMP T STL BOLL,` AND ST STL 60 CELL PHOTOVOLTAIC SERRATED'• U) MODULE TYP. FLANGE -NU 46 Q l ALUMINUM L-FOOT TY END -CLAMP V TYP EVERY ROOF1. PENETRATION SIZE VARIES.♦ - EX CAP ST STL BOLT STL BOLT AND ST STLSERRATED ,�10, FLANGE -NUT TYP . -_ UNIRAC RAIL (TYP-) ) ASPHALT SHINGLE ROOFINGTYP. - WOOD 5116" ST STL LAG SHEATHING SCREW. SEE SCH FOR EMBED DEPTH ' WOOD ROOF REQ. TYP EACH TRUSS TYP. L-FOOT - TYPICAL PV SOLAR RAIL END CONNECTION DETAIL TYP. HANWHA Q.PEAK BLK-G4.1 280 (290W) S.Y.P. 2)(4 LOCATE BETWEEN MODULE TYP. TRUSSES AND NAIL WITH 2-16D NAIL PATTERN AT EACH END TO WOOD TRUSS ia• DIA TEEL -- ALL-THSRo _ -- ROD WI NUT- - - WASHERS-LOCTITE ALL NUTS TYP. _ ALL CONNECTIONS - - 2X PT S.Y.P. WOOD OR V-1— UNISTRUT COW. ALONG COLLECTOR TYP SPANNER CONNECTION DETAILS (IF REQUIRED) RC ENGINEERING, LLC COAi2834S 2381 CREST RIDGE COURT SANFORD, FL 32771 TEL• 407474.8181ER6=RATES E CASTILLO-FL PE 52590 REVISIONS DESCRIPTION DATE REV AS PER INSTALLER 12108=17 Qq PROJECT DEVELOPER co 0 ,,'j11111111111 v • .• SignaturevAth A�� LL �rn O ul O. ¢ 0= o Z �! `, U Lo Z Q M � J W OV o� a �a w Z o MO W SHEET NAME STRUCTURAL ATTACHMENT DETAILS SHEET SIZE ANSI B ll"X 17" SHEET NUMBER S-02 M. Wind Speed Ult (mph) 160 Risk Category !I Wind Speed ASD (mph) 130 Exposure Category Mean Roof Height (ft) 20 Roof Slope (degrees) Q Module Area (sq ft) 20 Kzt 1 Height Adjustment Factor, X 1 Roof Zone Pnet (30) 1 16 -27 2 16 -44.6 3 1 16 -67 P_net=[AK➢_zt P_(net(30)) Roof Zone Pnet 1 16 -27 2 16 3 16 -6�7 Roof Slope Calculator Rise _Run_ _ Slope (' MM 22.6 Maximum Uplift per *fastener Wind Zone 1 297.0 Per American Wood Council - NDS Max Withdraw Load for 5/16" 476 LAG with 2.5" Embedment * Roof attachements at 4' O/C w 2 rails Maximum Uplift per *fastener Wind Zone 2 245.3 Per American Wood Council - NDS Max Withdraw Load for 5/16" 476 LAG with 2.5" Embedment *Roof attache ments at N O/C w 2 rails Maximum Uplift per *fastener Wind Zone 3 368.5 Per American Wood Council - NDS Max Withdraw Load for 5/16" 476 LAG with 2.5" 130 150 115 Notes 159 1: - values are ultimate, desigq_ 3-second .gnsE wind speeds in miles -per -.hour (m/s)at 33 ft (10q). above ground for Ezposure'C cat eg 'ry: 2,-:.- Linear- interpolation between ,contours" is peruitted•." - - 'Islands and,coastal'.areas outside the last contoarv.shall, use the�last wind: speed ou contr of .the coastal.area. 4. ,Mountainous -terrain, gorges; ocean pro* onto i•ies, and special wind ;regions shall -tie ezaoined for. unusual, wind condi tions.: 5. Wind. speeds coi•respond.to:approxisately a-7% p'�obatiility of'exceedance'io 50 years (Annual Exceedance Probability' .O'.00143, MRI = 700 years).: 170 R%7 Embedment FIGURE 1609A ULTIMATE DESIGN VIAND SPEEDS, VOLT, FOR RISK CATEGORY 11 BUILDINGS AND *Roof attachements at 2' O/C w 2 rails OTHER STRUCTURES RC ENGINEERING, LLC COA 028345 2381 CREST RIDGE COURT SANFORD, FL 32771 TEL: 407474-9181ERMOCRATES E. CASTILLO • FL PE 52580 REVISIONS DESCRIPTION DATE REV AS PER INSTALLER 12/082017 AA PROJECT DEVELOPER 0 `,,1111111111/�� w to W o `O e Pq11111111111` W U r- Z 0) 1.1.1 M � 0 J co LL W W O0 a Q to CO z o O m SHEET NAME STRUCTURAL ATTACHMENT DETAILS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER S-02.1 (2) #10 AWG USE-2/PV WIRE + Red (2) #10 AWG USE-21PV WIRE - Black EGC #8 BARE CU IN FREE AIR (N) JUNCTION BOX 600 V, NEMA 3 UL LISTED I I I I I I I I I L- — — — — — — — — — (2) #10 AWG THWN-2 + Red (2) #10 AWG THWN-2 - Black EGC #8 THWN-2 IN 3/4" PVC CONDUIT RUN USE METAL RACEWAYS FOR ANY DC CIRCUITS ENTERING BUILDING PRIOR TO INVERTER DC DISCONNECTING MEANS PER 690.31 1 ELECTRICAL LINE DIAGRAM E-01 SCALE: NTS (N) INVERTER: #1 SB 3.8-1SP-US40 OUTPUT: 240 VAC, 16A 96.5% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT I I I . I 1 I I SOLAR ARRAY 5.22 KW -DC STC (18) HANWHA Q.PEAK BLK-G4.1 290 (290W) MODULES TOTAL (01) STRING OF 09 MODULES CONNECTED TO MPPT#1 (01) STRING OF 09 MODULES CONNECTED TO MPPT #2 PV MODULE GROUNDING SYSTEM (N) PV METER (SMUD/GRIDLEY ONLY) (IF REQUIRED) LINE SIDE TAP USING POLARIS TAPS OR INSULATION PIERCING (N) AC DISCONNECT: 240V, 60AMP FUSED NEMA 3R, UL LISTED WITH 2OAl2P BREAKER (3) #10 AWG THWN-2 (1) #8 AWG THWN-2 GND IN 3/4" PVC CONDUIT RUN TO UTILITY GRID L1 L2 N♦♦ �O BI-DIRECTIONAL = ;' o UTILITY METER 1-PHASE, 240V CJ): �Q. L1 L2 NTTT C� L1 L2 N (E) MAIN DISTRIBUTION i PANEL, 100A RATED, 240V.T' (E) MAIN LUG ONLY BREAKER 240V, 10OAl2P 20Al2P I N (2) #6 AWG THWN-2 I G (1) #8 AWG THWN-2 GND — — EXISTING GROUNDING IN 1" PVC CONDUIT RUN L — — — — — — — ELECTRODE SYSTEM PROVIDE GROUNDING ELECTRODE CONDUCTOR FROM THE INVERTER TO AN EXISTING SERVICE GROUNDING ELECTRODE PER 690.47(B) 1 RC ENGINEERING, LLC COA 028345 2381 CREST RIDGE COURT SANFORD, FL32771 TEL• 407474-9181ERMOCRATES E CASTILLO• FL PE 52590 REVISIONS DESCRIPTION DATE REV AS PER INSTALLER 121082017 A PROJECT DEVELOPER 00 Signature S s L0 W m N * z Q 'Q� PROJECT NAME w U Z W Q � M 0 J LL W OV Q �a CO� Z 0 0 m SHEET NAME ELECTRICAL LINE DIAGRAM SHEET SIZE ANSI B 11" X 17" SHEET NUMBER E-01 DC CONDUCTOR AMPACITY CALCULATIONS: ARRAY TO JUNCTION BOX (INV #1): EXPECTED WIRE TEMP (In Celsius) 33° TEMP. CORRECTION PER TABLE (310.16) 0.96 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) 0.80 CIRCUIT CONDUCTOR SIZE 10 AWG CIRCUIT CONDUCTOR AMPACITY I 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 1.25 X 1.25 X Isc 15.05A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X 30.72A CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (15.05A) otherwise less the entry for circuit conductor size and ampacity DC CONDUCTOR AMPACITY CALCULATIONS: FROM JUNCTION BOX TO INVERTER (INV #1); AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER NEC 310.15(B)(2)(c) +�, EXPECTED WIRE TEMP (In Celsius) 33'+2Z = 5T TEMP. CORRECTION PER TABLE (310.16) 0.76 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) _ 0.80 CIRCUIT CONDUCTOR SIZE 10 AWG CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 1.25 X 1.25 X Isc 15.05A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X 24.32A CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (15.05A) otherwise less the entry for circuit conductor size and ampacity ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY -IN LUG. AC CONDUCTOR AMPACITY CALCULATIONS: No. OF INVERTER 1 EXPECTED WIRE TEMP (In Celsius) 33' TEMP. CORRECTION PER TABLE (310.16) 0.96 NO. OF CURRENT CARRYING CONDUCTORS 3 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) 1 #1 CIRCUIT CONDUCTOR SIZE 10 AWG CIRCUIT CONDUCTOR AMPACITY 40A INVERTER OUTPUT CONDUCTORS (INV #1) REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 1.25 X MAX INVERTER OUTPUT CURRENT 20.00A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X 38.40A CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (20.00A) otherwise less the entry for circuit conductor size and ampacity DC PHOTOVOLTAIC POWER SOURCE TO BE INSTALLED AT INVERTER #1 PER NEC 690.53 & 690.54 OPERATING CURRENT 11.34A OPERATING VOLTAGE 287.64V SHORT CIRCUIT CURRENT 9.63A MAXIMUM SYSTEM VOLTAGE 398.56V SOLAR MODULE SPECIFICATIONS MANUFACTURER HANWHA MODEL # Q.PEAK BLK-G4.1 290 PMAX 29OW VMP 31.96V IMP 9.07A VOC 39.19V ISC 9.63A MODULE DIMENSION 65.7"L x 39.4"W x 1.26"D (In Inch) INVERTER #1 SPECIFICATIONS MANUFACTURER SUNNY BOY INVERTER MODEL # SB 3.8-1SP-US-40 NOMINAL AC POWER 3.8 KW NOMINAL OUTPUT VOLTAGE 240V NOMINAL OUTPUT CURRENT 16A PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 0.80 4-6 0.70 7-9 0.60 10-20 RC ENGINEERING, LLC COA 028345 2381 CREST RIDGE COURT SANFORD, FL 32771 TEL• 407-07d9181ERN10CRATES E. CAS11LLO - FL PE 52590 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER P O dD LLj t� du0f4gpf /h♦♦ l! 40 U. b •?� Oto CC :U O: :.L) N �: CO 01 PR ���►aerieel��i' LU U LO Z 0)) LLI M 0_ t] J W 47 LL LU E2 LL W p � J LLJ Q U a CO O o m SHEET NAME WIRING CALCULATIONS SHEET SIZE ANSI B 11" X 17" SHEET NUMBER E-02 ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: NEC 690.35(F)) (To be used when inverter is ungrounded] ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: NEC 690.35(F)) ]To be used when inverter is ungrounded] ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC 690.17(E)) ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: NEC 690.17(E), CB LABEL LOCATION: INVERTER, JUNCTION BOXES (ROOF), AC DISCONNECT (PER CODE: NEC690.13.G.3 & NEC 690.13.G.4) LABEL LOCATION: CONDUIT, COMBINER BOX (PER CODE: NEC690.31(G)(3)(4) & NEC 690.13(G)(4) ADHESIVE FASTENED SIGNS: • THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. • WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535A [NEC 110.21(B) FIELD MARKING]. • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.31 LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC690.54) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: NEC 705.12(D)(7)) ,Not required if panelboard is rated not less than sum of ampere ratings of all overcurrent devices supplying it] LABEL LOCATION: EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING METHODS. COVERS OR ENCLOSURES OF PULL BOXES AND JUNCTION BOXES. CONDUIT BODIES IN WHICH ANY OF THE AVAILABLE CONDUIT OPENINGS ARE UNUSED. (PER CODE: NEC 690.31) LABEL LOCATION: DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC690.13(B)) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC 705.12(D)(4)) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC690.15, 690.13(B)) 311 NOTICE THIS BUILDING CONTAINS DUAL POWER SOURCES. THE SECOND SOURCE IS A i1) PHOTOVOLTAIC SYSTEM. DISCONNECTS FOR THIS SYSTEM ARE LOCATED IN MAIN DISTRIBUTION PANEL LABEL TO BE PLACED AT METER CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN Al.® METER AND MAIN DISTRIBUTION PANEL AC DISCONNECT PV METER INVERTER p< MARKING CONTENT AND FORMAT • RED BACKGROUND • WHITE LETTERING • MINIMUM 3/8" LETTER HEIGHT • ALL CAPITAL LETTERS • ARIAL OR SIMILAR FONT, NON -BOLD • REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT) RC ENGINEERING, LLC COA#28345 2381 CREST RIDGE COURT SANFORD, FL32771 TEL 47-474.9191ERMOCRATES E CASTILL O - FL PE 52590 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER r r Co J IIIIUf Ljj ♦♦♦ ILL ) Z cc w OP '20JECf WNE'. ♦ ♦♦ '�ffffllllllltttt W U Z rn w M 0 J C 00 0 � Q 1U Z�w O o m SHEET NAME SYSTEM LABELING SHEET SIZE ANSI B 11" X 17" SHEET NUMBER E-03 08/12/2017 PV Watts Calculator asNREL RESULTS 6,630 kWhjYear* Caution: Photnvdtalc syia— DoPompnce pnM�Usorn owaw by Pvwatte^ nwea rAa^y Iwereat —Pidls an d system output may range tram 6.264 to 6,948kM r year near this location. ' Y P Y n9 per Y Ur—L-L- and m not IeL t vuiatims bans P/--f dV. ndr sae-spc�;ra '-------------___.------------------------�.---------------_...---..._--------------... dsa,aCt—Um except as neprasm°ad by Month Solar Radiation AC Energy Energy Value PJWattSL" Inputs- Fa erompk, PV mod°f. w;Ih Lauer Pedorrrenre4 me roc dJfinent¢[ed within PJlvaps� hom c ( kWh l m2l day) ( kWh) (S 1 pmfomCng rrio,10.1 8CN NREL .4 on --a O-Paoies Prueda nnre wisp td PV January 3.33 417 -- ' 43 niodeft toss (suds as the System Advkar Maid at hup:gsmn.nraLgor) that amw fd February 3.89 444 46 mote precise and mmplox moddmg of PV , sYs[=tM March 4.77 589 61 the mngt k 30 years of , l —a9 at acted neatlar dace ac Liss yrvm lotion qi Ana u "dm W P—de an itd atiw of April 5.45 645 67 I. van ation You .01 — For more irdmmatan, please refer to this NREL repaF , May 5.72 702 73 The Enm Report. June 5.45 636 66 ! OWN— IT. Pwiele Mndel ('htpdec') July 5.66 680 71 is pro,n by the NaUmal R—Are EneTy Lataratory YhM is byAln(•NREL'), opmarcd by ttw_ mce for Suszu:ade August 5.37 647 67 ' Enengy, CAltianre') for the U.S. 1311.1 and Of Erargy CDOE-) and may be • September P 4.88 569 59 •"" for my popree wtutsoeyer. Tho rsnmes DWNREUAWAN^CE steR n°t October 4.17 508 53 be u.d N any repr—.*boo, ad�[nisg, peblidty ar odmr rsL — hatsc—Y to ; ewarscardmnteaMCHltytluladmplsor November 3.47 414 43 ! irs Flodd. DOEINREL/ALLTANCE #sin Um . rIm vmsee December 3.04 380 ) 39 any s W t foo-AN, t1aamn9 of - a aa.,... or air nrd Yntn n yana m the or the Model or any updates, rerisims w Annual 4.60 6,631, $ 688 new venlons d the MadeL ' You AGREE TO INDEMNIFY OOMJ REI/ALLIANC, AND ITS AFFILIATES, — —^ OFFICERS • AGENTS, AND E"IPLDYEES AGAINST MN CLAIM OR DEFWID, Location andStationIdentification , INCLUDING REASOPWDLE ATTORNEYS'. — PEES, RELATED TO USE, RELIANCE, THE OR ADOPTION OF THE MODEL FOR ANY Q Re uested Location 6507 DORIS DR, FORT PIERCE, FL 34951 PURPOSE WHATSOEVER. THE MODEL IS PROVIDED BY IDDE NRE/ALLIANCE AS 17 Weather Data Source (TMY2) WEST PALM BEACH, FL 63 mi AND ANY IXRt6S OR IMPLIED , V/ARRMmES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRA"ES OF Latitude 26.68° N MERCTANTABILITY AND FITNESS FOR A PARTICDIAR PURPOSE ARE EXPRESSLY DISCLAIMED. IN NO EVEtdT SHALL Longitude g 60.1° W DOE/NRWAUAANCE DE LIABLE FOR ANY.— INDIRECT OR CONSEQUENTIAL PV System Specifications Residential (Residential) DAMM,t, DAMAGES DR ANY DAMAGES WluTsoEVER, Y P INCLUDING BUT NOT LIMITED TO CLAIMS ASSOCIATED WIT n IKE LOSS OF DATA OR DC System Size PROFITS, WHICH MAY RESULT FROM ANY Y 5.22 kW ' ACTION In CONTRAL7. NEGLIGENCE OR OTHER TORTIOUS CLAIM THAT ARISES OUT OF OR IN CONNECTION WITH THE USE OR " Module Type Standard PERFORMANCE OF THE MODEL ' Array Type Fixed (roof mount) The —9y output fmg9 is based on an°Iysis of 30 Ynas of l:stodml —it- Wt. for w1by . and is FmHUNd to P—ide ' t Array Tilt 22.6° m iidxdtim of me possm int&anmtal YanaWny In 9—atim far a F&ed (open Array Azimuth y 91° ' ,Trek) PV system at this I—m . System Losses 14% Inverter Efficiency 96% DC to AC Size Ratio 1.1 Economics------------------------ Average Cost of Electricity Purchased - from Utility 0.10 $lkWh Performance Metrics Capacity Factor 14.5% ---_ - _ _-----'-_^—_- _--- http://pvwatts.nrel.gov/pvwatts. php 1/1 4 RC ENGINEERING, LLC COA#28345 2381 CREST RIDGE COURT SANFORD, FL 32771 TEL• 407-474.9181ERNICCRATES E CASTILLO - FL PE M90 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER 19. co O ,,,�IIIIIf1l0///I U-3 0 Signature • A b U.s s o p O%� to CC to ~ O. O t' �•:GO o Z � p DTI �qt+ W U LO Z rn W M V! CO LL OLij 0 W a i) Z 0 0 LL m SHEET NAME PV WATTS SHEET SIZE ANSI B 11"X 17" SHEET NUMBER P-01 powered by e With its top performance and completely black design the new Q.PEAK BLK-134.1 is the ideal solution for all residential rooftop applications thanks to its innovative cell technology Q.MTUM. The world -record cell design was developed to achieve the best performance under real condi- tions - even with low radiation intensity and on clear, hot summer days. ®LOW ELECTRICITY GENERATION COSTS '` Higher yield per surface area and lower BOS costs thanks to higher power classes and an efficiency rate of up to 18.3%. ,j INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH PERFORMANCE nLong-term yield security with Anti-PID Technology', Hot -Spot -Protect and Traceable Quality Tra.QTm. EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for high snow (540OPa) and wind loads (4000Pa) regarding IEC. MAXIMUM COST REDUCTIONS Up to 10% lower logistics costs due to higher module capacity per box. A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance guarantee2. THE IDEAL SOLUTION FOR: Rooftop arrayson residential buildings Engineered in Germany 'EUPO RESEARCH raadlnEs r Quuu •sated 0.40032587 Phn tnn awls seat nodd&2014 sda moeole 2a14 4➢t�9�s APT test conditions: Cells at -1500V against grounded, with conductive me- tal foil covered module surface, 25•C, 168h ' See data sheet on rear for further information. OCELLS SPECIFICATIONMECHANICAL Format 65.7 in x 39.4in x 1.26in (including frame) •e (1670mm x 1000mm x 32mm) Weight 41.45lbs(18.8kg) s••�eq,m.aaw.� From Cover 0.13 in (32mm) thermally pre -stressed glass with anti -reflection technology Back Cover Composite film frame Black anodized aluminum + I Q,,, + ®••I Cell 6 x 10 monocrystalline Q.ANTUM solar cells Junctionbox 2.60-3.031n x4.37.3.54in x 0.59-0.75in (66.77mm x 111-90mm x 15-19mm), Protection class IP67, with bypass diodes + •,a.,,-�.„ '•'��a` Cable 4mm2 Solar cable;(+)a39.37in(1000mm), W a39.37in(1000mm) Connector Multi -Contact MC4 or MC4 intennateable, IP68 POWER CLASS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE +5 W Power at MPP' P_ IW] Short Cftcuft Current` I,c (A] Open Circuit Voltage- V. M � Currant at MPP• I- fAl Voltage at MPP• _ V_ IV] Efficiency' 0 (%] MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NBC' 290 1 295 300 290 295 300 9.63 9.70 9.77 39.19 39.48 39.76 9.07 9.17 9.26 31.96 32.19 32.41 2t17.4 t 17.7 z 18.0 PawetatMPP' P., 1W) 214.4 E Shalt Circuit Current* Open Circuit voltage. V,c M 36.65 Current at MPP• I- [A) 7.1E Voltage at MPP• V_ IV] 30.1E 11000W/m2, 25-C, spectrum AM 1.5G 'Measurement loleranas STC -3%; NOC 15% 1800W/m7, NOCT, spectrum AM 1.5G Q CELLS PERFORMANCE WARRANTY At least 98%of nominal power during first year. Thereafter max. 0.6% degradation per year. ---------------- At least92.6% of nominal paver up to 10 years. z 4 At least 83.6% of nominal power up to 25 years. --------------- €a r+t ff� All data within measurement tolerances. a Full warranties in accordance with the warranty terms of the Q CELLS sales ownisation of your F respective country. .r 218.1 221.8 7.82 7.88 36.92 37.19 7.20 7.27 30.30 30.49 `typical values, actual values may differ PERFORMANCE AT LOW IRRADIANCE __�-----r---- r----------- I I ; i r m I I I I i r I I I I W I I I I I I I I I I I 1 I i I 6 ® m mo ew w Iwo IRRADIANCE nvrm•I Typical module performance under tow irradiance conditions in comparison to STC conditions (256C, 1000W/m7). TEMPERATURE COEFFICIENTS Temperature Coefficient of I. a [%/K] +0.04 Temperature Coefficient of Vic (i [%/K] -0.28 Temperature Coefficient of P_ V [%/K] -0.39 Normal Operating Cell Temperature NOCT ["F] 113 f 5.4 (45 m3'C) • • FORSYSTEM PROPERTIESDESIGN Maximum System Voltage V_ IV] 1000 (IEC) ! 1000 (UL) Safely Class II Maximum $atlas Fuse Rating [A OC1 20 Fire Rating C (IEC) / TYPE 1 (UL) Design load, push (ULY I St tq 75 (3600 Pa) Permitted module temperature -40•F up to +185'F on continuous duty (-40'C up to +85'C) Design load, pull (ULY [Ibs/fPl 55.6 (2666Pa) 'see installation manual UL 1703; VDE QualityTested; CE-mmpliant; Number of Modules per Pallet 32 IEC 61215 (Ed.2); IEC 61730 (Ed.l) application class A Namher M Pallas per 53' Container 30 ♦ ♦ SP® Number of Pallets per 40' Container 26 DVE (♦ C Cvu Lis Pallet Dimensions (L x W x N 68.7 in x 45.3 in x 46.1 in z>.,<• (1745mm x 1150mm x 1170mm) Pallet Weight 1435lbs (651 kg) NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product Hanwha Q CELLS America Inc. 3DO Spectrum Center Drive, Suite 1250, Irvine, CA 92618, USA I TEL+1 949 748 59 961 EMAIL Inquiryous.q-cells.com I WEB vnvw.gtells.us e�s RC ENGINEERING, LLC COA tf 28345 2381 CREST RIDGE COURT SANFORD, FL 32771 TEL: 407474-9181ERMOCRATFS E. CASTILLO- FL PE 52590 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER C-A C0 v ty � 6111 1111 f �0 'ii0>, � � igRateroNdt�. /h • I� lJ 10 6 �. Q z w In O. _O CO Ojf,CT ME f e%% /1'111111►�' . U LO W clo 0 0 J LL OV 0 � a Q LLO � � Z O o M SHEET NAME DATA SHEET SHEET SIZE ANSI B 11If X 17" SHEET NUMBER DS-01 _C, tic .,'j ,i�:J C�.l.. ;i-i• w r �. 9ff_, �i_l�. I' ,';")).1 -Cr Vr S' I'v..�6.� / a. �I isl r+!z�-�,o Value -Added Improvements • Superior integration with SMA's MLPE Power+ Solution • World's first Secure Power Supply` now offers up to 2,000 W • Full grid management capabilities ensure a utility -compliant solution for any market Reduced Labor • New Installation Assistant with direct access via smartphone minimizes time in the field • Integrated disconnect simplifies equipment stocking and speeds installation Unmatched Flexibility • SMA's proprietary OptiTracr`4 Global Peak technology mitigates shade with ease • Multiple independent MPPTs accommodate hundreds of stringing possibilities SMA Trouble -Free Servicing • Two-part enclosure concept allows for simple, expedited servicing • Enhanced AFCI technology reduces false tripping while improving sensitivity in real arc SUNNY BOY 3.0-US / 3.8-US / 5.0-US / 6.0-US / 7.0-US / 7.7-US Reduce costs across your entire residential business model The residential PV market is changing rapidly. Your bottom line matters more than ever -so we've designed a superior residential solution to help you decrease costs at every stage of your business operations. The Sunny Boy 3.0-US/3.8- US/5.0-US/6.0-US/7.0-US/7.7-US join the SMA lineup of field -proven solar technology backed by the world's #1 service team, along with a wealth of improvements. Simple design, improved stocking and ordering, value -driven sales support and streamlined installation are just some of the ways that SMA helps your business operate more efficiently. And, Sunny Boy's superior integration with the innovative Power+ Solution means installers have even more flexibility in addressing their toughest challenges. www.SMA-America.com Technical data Sunny Boy 3.0-US 208 v 240 V Input (DC) Max. usable DC power 3100 W 31 DO W Max. DC voltage Rated MPP voltage range 155 -480 V MPPT operating voltage range Min: DC voltage / start voltage Max. operating input current per MPPT Max. short circuit current per MPPT - Number of MPPT tracker / string per MPPT tracker Output (AC) AC nominal power 3000 W 3000 W Max. AC apparent power 3000 VA 3000 VA Nominal voltage / adjustable 208 V / • 240 V / • AC voltage range 183 - 229 V 211 - 264V AC grid frequency Max. output current 14.5 A 12.5 A Power factor (cos rp) Output phases / line connections Harmonic Efficiency Max. efficiency 97.2 % 97.6 % CEC efficiency 96 % 96.5 % Protection devices Sunny Boy 5.0-US 208 V 240 V 5150 W 5150 W 220 - 480 V 3/1 5000 W 5000 W 5000 VA 5000 VA 208V/• 24OV/• 183 - 229 V 211 - 264 V 24.0 A 24.0 A 97.2 % 97.5 % 96.5 % 97 % DC disconnect device • DC reverse polarity protection Ground fault monitoring / Grid monitoring • AC short circuit. protection • A rpole sensitive residual current monitoring unit (RCMU) • Arc fault circuit interrupter [AFCI) . ' • Protection class / overvoitage category General data Dimensions (W / H / D) in mm (in) 535 x 730 x 198 (21.1 x 28.5 x 7.8) Packaging dimensions (W / H / D) in mm (in) 600 x 800 x 300 (23.6 x 31.5 x 11.8) Weight / packaging weight _ 26 kg'(57lb) / 30'k9 (66 lb) Operating temperature range - 25 •C .. +60•C Noise emission (typical) 39 dB(A) Internal power consumption at night <.5 W Topology - Transformerless Cooling concept - Convection Features Ethernet ports 2 • - Secure Power Supply - • • Display (2 x 16 characters) • , WIAN • Sensor module / External WIAN antenna O / O Warranty. 10 / 15 / 20 years •/O/O Certificates and approvals UL 1741, UL 1998, UL 1699B, IEEE 1547, FCC Part 15 (Gass A & B), CAN/CSA V22.2 167.1-1 • Standard features 0 Optional features - Not available Data at nominal condiBons NOTE: US inverters ship with gray lids. • Not functional with Power+ Solution Type designation- SB3.0-1SP-US-40 S83.8.1SP-US-40 S85.0-1SP-US40 Accessories MD.SEmodule EXTAN US40 om•n+a _ „ SMA RooBop MD.SEtJL5d0 EXTANT-US-0O � � Communimtion IGI p I ROOFCOMMKR-PWS --- ........................................................... Efficiency curve SUNNY BOY 6.0-1SP-US-40 i--- .... ............ •-•, i 96r .......94 9286-•- %IV•-480VI K..M 0.0 0.2 0.4 0.6 0.8 1.0ow Output power/ Rated per RC ENGINEERING, LLC COA#28345 2381 CREST RIDGE COURT SANFORD, FL32771 TEL: 407-474-9181ERMOCRATES E. CASTILLO- FL PE 52590 REVISIONS DESCRIPTION DATE _ REV PROJECT DEVELOPER O C'v Co v W `��fi11111/11 ,� Signa •• ••V •• U_ 6- •• �; k" O 0 co LO CO cc eL • LLJ rn O •V U) � I PR Tc,p-;T W U Z a� W M 0 ''0 CD _J W OV 0 W Ln I.- CC) IX Z MO W SHEET NAME DATA SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-02 x ."UNIRAC NILT GSOUF (GAl F: �YV SolarMount Technical Datasheet Pub 100602-ltd V1.0 June 2010 SolarMount Module Connection Hardware.................................................................. 1 BottomUp Module Clip.................................................................................................1 MidClamp....................................................................................................................2 EndClamp....................................................................................................................2 SolarMount Beam Connection Hardware......................................................................3 L-Foot...........................................................................................................................3 SolarMountBeams..........................................................................................................4 SolarMount Module Connection Hardware BE SolarMount Bottom Up Module Clip Part No. 321001, 321002 1.24 Y .10 ►x Dimensions specified in inches unless noted • Bottom Up Clip material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear Anodized • Bottom Up Clip weight: -0.031 Ibs (14g) • Allowable and design loads are valid when components are assembled with SolarMount series beams according to authorized UNIRAC documents • Assemble with one'/4"-20 ASTM F593 bolt, one'/4"-20 ASTM F594 serrated flange nut, and one'/," flat washer • Use anti -seize and tighten to 10 ft-Ibs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory • Module edge must be fully supported by the beam * NOTE ON WASHER: Install washer on bolt head side of assembly. DO NOT install washer under serrated flange nut Applied Load Direction Average Ultimate Ibs (N) Allowable Load Ibs (N) Safety Factor, FS Design Load Ibs (N) Resistance Factor, 4) Tension, Y+ 1566 (6967) 686 (3052) 2.28 1038 (4615) 0.662 Transverse, X± 1128 (5019) 329 (1463) 3.43 497 (2213) 0.441 Sliding, Z± 66 (292) 1 27 (119) 1 2.44 41 (181)1 0.619 SolarMount Mid Clamp Part No. 320008, 320009, 320019, 320020, 320021, 320084, 320085, 320086, 320087, 320120, 320122 Mid Clams 1.00 DISTANCE BETWEEN MODULES I I Y - 1 L-► X Dimensions specified in inches unless noted SolarMount End Clamp Part No. 320002, 320003, 320004, 320005, 320006, 320012, 320013, 320014, 320015, 320016, 320017, 320079, 320080, 320081, 320082, 320083, 320117, 320118, 320123, 320124, 320173, 320185, 320220, 320233, 320234, 320331 _ Serrated, Flange Nut Y 1 -► X r Ls _ MINIMU-MI ,¢IDMr VARIES � �-- I 147TM MODULE 1 I TM CKNESS I i I Dimensions specie n In es un ess no ed a :"UNIRAC 1'71T.I GROUP C&MPANY • Mid clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • Mid clamp weight: 0.050 Ibs (23g) • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single mid clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble mid clamp with one Unirac'/4"-20 T-bolt and one'/4"-20 ASTM F594 serrated flange nut • Use anti -seize and tighten to 10 ft-Ibs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory Applied Load Direction Average Ultimate Ibs (N) Allowable Load Ibs (N) Safety Factor, FS Design Load Ibs (N) Resistance Factor, m Tension, Y+ 2020 (8987) 891 (3963) 2.27 1348 (5994) 0.667 Transverse, Z± 520 (2313) 229 (1017) 2.27 346(1539), 0.665 Sliding, X± 1194 (5312) 1 490 (2179) 1 2.44 741(3295)1 0.620 Clamp • End clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • End clamp weight: varies based on height: -0.058 Ibs (26g) • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single end clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble with one Unirac %%20 T-bolt and one'/4"-20 ASTM F594 serrated flange nut • Use anti -seize and tighten to 10 ft-Ibs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory • Modules must be installed at least 1.5 in from either end of a beam Applied Load Direction Average Ultimate Ibs (N) Allowable Load Ibs (N) Safety Factor, FS Design Loads Ibs (N) Resistance Factor, m Tension, Y+ 1321 (5876) 529 (2352) 2.50 800 (3557) 0.605 Transverse, Z± 1 63 (279) 14 (61) 4.58 21 (92) 0.330 Sliding, X± 1 142 (630) 1 52 (231) r 2.72 79(349)1 0.555 RC ENGINEERING, LLC COAK28345 2381 CREST RIDGE COURT SANFORD. FL $2771 TFU 407.47"181ERMOCRATES E. CASTILLO• FL PE 52590 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER O c� CD O v Uj O ,�tllllllf��� natu• l o p p. : Z Cv W (L u1 Ln 0 N �11,111111 p►,0% i Uj U Z rn w ct M 0 J fn LL OV C) IX J LU a Q t0 CD IX Z O o m SHEET NAME DATA SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-03