HomeMy WebLinkAboutApplication - CommentRECEIVED JAN 1 0 2018 ST'. Lucie County, Permitting DON J. NUELLE , P.E. 11634 SW Rowena ST Port Saint Lucie, FL 34987 P.E. # 52046 PH. # 561-629-6975 APPLICATION5179 CONTRACTOR' 1'kLYL&Konstraction Inc OWNER NAME SHERRY ANDERSON ADDRESS 10725 SOUTH OCEAN DRIVE #482 JENSEN BEACH, FL., 34957 COMMENT Comment: PLANS EXAMINER REVIEW INCOMPLETE William Durden 1215/2017 12/5/2017 Comment: • PLEASE SUBMIT GEOTECHNICAL REPORT IN COMPLIANCE WITH R401 OF THE 2014 RESIDENTIAL BUILDING CODE. Comment: • PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND 12151217 0APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE 12/5/2017 Comment: • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE Comment: • ELEVATION ON SURVEY SHOWS THE NEW STRUCTURE'S FINISH FLOOR TO BE FINISHED AT BASE 12/512017 FLOOD ELEVATION. PLEASE SHOW ON PLANS THAT ALL MATERIALS BELOW BASE FLOOD MEETING THE REQUIREMENTS OF CHAPTER 3 SECTION 322 SUBSECTION R322.1.8 FLOOD RESISTANT MATERIALS. SEESlIRVEY Comment: • PLEASE FURNISH EITHER THE [CC EVALUATION REPORT OR A EVALUATION REPORT FROM A AND SNT A-4 Tf/EIST NOTE 12/512017 CERTIFIED TESTING LABORATORY THAT THE INSULATION LOCATED BELOW BASE FLOOD MEETS THINNOER GENERAL NOTES REQURRMENTS OF SECTION R322.1.8 OF THE 2014 FLORIDA RESIDENTIAL CODE FLOOD RESISTANT MATERIALS. SEE REPORT 12/5/2017 Comment: SEE PAGE A-8 SECTION B FINISH FLOOR ELEVATION IS INCORRECT. SEE SECTION 107 OF THE 2014 FLORIDA BUILDING CODE. ZFVrA-8 DON J. NUELLE , P.E. 11634 SW Rowena ST Port Saint Lucie, FL 34987 P.E. # 52046 PH. # 561-629-6975 APPLICATION # 1710-0579 CONTRACTOR L & C Construction Inc OWNER NAME SHERRY ANDERSON ADDRESS 10725 SOUTH OCEAN DRIVE #482 JENSEN BEACH, FL., 34957 I •aye � Comment: • PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING THE SQUARE FOOT INFORMATION OR A LETTER FROM THE DESIGN PROFESSIONAL SPECIFYING THE 12l5/2017 CUBIC VOLUME OF THE CONDITIONED SPACE. SEE CHAPTER 1 SECTION 107 OF THE 2014 FLORIDA BUILDINGCODE. SEES1TA-2 12/5/2017 Comment • INSULATION R VALUES STATED ON THE ENERGY CALC'S DO NOT MATCH THE SUBMITTED DRAWINGS RF(4KFCD FNFRGYCALCS TO FOR REVIEW_ SEE CHAPTER 4 SECTION 402 SUBSECTION 402.1.2 OF THE 2014 FLORIDA ENERGY CODE. SNOW INSULATION IN FIRST Comment: PLEASE CLARIFY THE DOOR LOCATED IN THE GARAGE NEAR THE BACK LEFT SIDE. IF THIS IS A DOOR 121512017 PLEASE SHOW THE TRANSITION FROM THE HOUSE TO THE GARAGE FLOOR ELEVATION. SEE SECTION FLOOR TRUSSFS 107 OF THE 2014 FLORIDA BUILDING CODE. T#IS IS A DOOR TO GO UNDER TNF FLOOR TRUSSES Comment: SURVEY SHOWS 5 INCH SEPARATION FROM THE PROPERTY LINE. PLANS SHOW 6 INCH SEPARATION. IF 12/512017 THE SURVEY IS CORRECT THE GUTTER IS 5 3/4 OF AN INCH WHICH PUTS YOU OVER THE PROPERTY LINE. PLEASE CORRECT AND SUBMIT. SEE SECTION 107 OF THE 2014 FLORIDA BUILDING CODE. Comment INCOMPLETE PRODUCT REVIEW AFFIDAVIT. SURKMWOULD SAY 611 • SUBMIT THE PRODUCT APPROVALS, IN DUPLICATE OR PRODUCT REVIEW AFFIDAVIT COMPLETE WITH FLORIDA PRODUCT APPROVAL OR N.O.A. NUMBER WITH INSTULATION INSTRUCTIONS AND SIGNED 12/5/2017 SEALED AND DATED BY THE DESIGN PERSON OF RECORD FOR ALL COMPONETS AND CLADING IN ACCORDANCE WITH 553.842 OF THE FLORIDA STATUTES. PRODUCT APPROVALS MUST BE HIGHLIGHTED OR MARKED IDENTIFYING THE OPENING OR CLADDING COMPONENTS, WITH FASTENERS AND DESIGN PRESSURES. SEE SPIT A-j Comment NOTE: IF SUBMITTING 2 COPIES OF PRODUCT APPROVALS (I.E. N.O.A. OR STATE OF FLORIDA APPROVAL) IN LUE OF THE PRODUCT APPROVAL AFFIDAVIT DOCUMENTS MUST BE HIGHLIGHTED OR 12/5/2017 MARKED IDENTIFYING THE OPENING OR CLADDING COMPONENTS, WITH FASTENERS AND DESIGN PRESSURES. Comment: • PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE 12/5/2017 SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS. ZONING REVIEW INCOMPLETE Lydia Galbraith 111212017 Comment: PROPERTY HAS TWO DIFFERENT FLOOD ZONE ELEVATIONS, AE-7 AND AE-8, BOTH NEED TO BE 11/212017 INDICATED ON THE SURVEY.PLEASE INDICATE THE DIVIDING LINE OF AE-7 AND AE-8 ON THE SURVEY AS WELL. SFESURW 1102017 Comment: PLEASE PROVIDE THE COST OF CONSTRUCTION. 11=017 Comment: PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW_ THE PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS.