HomeMy WebLinkAboutDisapproved Energy Efficiency CodeFORM R405-2014
"- ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 93. Rig �'l-°
The lower the EnergyPerformance Index, the more efficient the home. APR 0 ,pp�g
A_
-wag
10725 SOUTH OCEAN DRIVE #482, JENSEN BEACH, FL, 34957 a' Lu ie coUntyen!
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows"
Description
a. U-Factor:
Dbl, U=0.65
SHGC:
SHGC=0.25
b. U-Factor:
Sgl, U=0.65
SHGC:
SHGC=0.25
c. U-Factor:
N/A
SHGC:
d. U-Factor.
N/A
SHGC:
Area Weighted Average Overhang Depth
Area Weighted Average SHGC:
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Int Insul, Exterior
R=4.0
2118.80 ft2
b. Frame - Wood, Adjacent
R=11.0
168.67 ft2
1
c. Frame - Wood, Exterior
R=19.0
106.67 ft2
3
d. other (see details)
R=
100.00 ft2
No
10. Ceiling Types
Insulation
Area
a. Cathedral/Single Assembly (Unvented) R=0.0
891.00 ft2
1777
b. Roof Deck (Unvented)
R=21.0
886.00 ft2
Area
c. other (see details)
R=
285.00 ft2
59.08 ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: Garage
6 50
12.85 ft2
12. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
37.0 SEER:16.00
8. Floor Types
Insulation
a. Slab -On -Grade Edge Insulation
R=0.0
b. Raised Floor
R=21.0
c. other (see details)
R=
ft2
13. Heating systems
a. Electric Strip Heat
1.000 ft.
0.250
Area
14. Hot water systems
915.00 ft2
a. Electric
891.00 ft2
886.00 ft2
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: �, Date:
Address of New Ha e. %C��ZS Sc, ems/ 62Ly-e City/FL Zip: j4p
*Note: This is not a Building Energy Rating. If your Index is below 70, youl
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Cc
638-1492 or see the EnergyGauge web site at energygauge.com for informil
information about the Florida Building Code, Energy Conservation, contact t
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy q
1/18/2018 6:06 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 C
kBtu/hr Efficiency
4.0 COPA.00
Cap: 40 gallons
EF: 0.92
CF, CV, Pstat
0%4
E ST
fzQl .,
DISAPPROVED
',
FORM R405-2014
171ORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: - SHERRY ANDERSON
Builder Name:
Street: 10725 SOUTH OCEAN DRIVE #482
Permit Office: ST. LUCIE CO.
City, State, Zip: JENSEN BEACH , FL, 34957
Permit Number:
Owner: SHERRY ANDERSON
Jurisdiction: 661100
Design Location: FL, Fort Pierce
County:: ST. LUCIE (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(2494.2 sqft.)
Insulation- Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.0 2118.80 ft2
b. Frame - Wood, Adjacent
R=11.0 168.67 ft2
3. Number of units, if multiple family 1
c. Frame - Wood, Exterior
R=19.0 106.67 ft2
4. Number of Bedrooms 3
d. other (see details)
R= 100.00 ft2
10. Ceiling Types (2062.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Cathedral/Single Assembly (Unvented) R=0.0 891.00 ft2
6. Conditioned floor area above grade (ft2) 1777
b. Roof Deck (Unvented)
R=21.0 886.00 ft2
Conditioned floor area below grade (111:2) 0
c. other (see details)
R= 285.00 ft2
11. Ducts
R ft2
7. Windows(71.9 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 50
a. U-Factor. Dbl, U=0.65 59.08 ft2
SHGC: SHGC=0.25
b. U-Factor. Sgl, U=0.65 12.85 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
37.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
4.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (2692.0 sqft.) Insulation Area
EF: 0.920
a. Slab -On -Grade Edge Insulation R=0.0 915.00 ft2
b. Conservation features
b. Raised Floor R=21.0 891.00 ft2
None
c. other (see details) R= 886.00 ft2
15. Credits
CF, CV, Pstat
Glass/Floor Area: 0.040 Total Proposed Modified Loads: 74.96
PASS
Total Baseline Loads: 80.50
1 hereby certify that the plans and specifications covered by
Review of the plans and
- -vilE S-r
this calculation are in compliance witytheFl a Energy
specifications covered by this
Ip1+0�
�''��_
Code.
calculation indicates compliance
cy� iiq - �' .•�`
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
--
DATE:
this building will be inspected for
compliance with Section 553.908
7ga,s
I hereby certify that this buildi designed, is in compliance
Florida Statutes.
✓�,
with the Florida Energy C
CAD WE,
OWNER/AGENT: 4CC-&9zz4--
BUILDING OFFICIAL:
-ode
DATE: -
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house.
1/18/2018 6:01 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
l
T PROJECT
Title: SHERRY ANDERSON
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1777
Lot #
Owner: SHERRY ANDERSON
Total Stories: 2
Block/SubDivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
10725 SOUTH OCEAN
Permit Office: ST. LUCIE CO.
Cross Ventilation: Yes
County:
ST. LUCIE
Jurisdiction: 661100
Whole House Fan: No
City, State, Zip:
JENSEN BEACH ,
Family Type: Single-family
FL, 34967
New/Existing: New (From Plans)
Comment:
CLIMATE
v
IECC Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location
TMY Site Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90
70
75 299
62 Low
BLOCKS
Number Name
Area Volume
1 Block1
2692 25562
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1 Main
891 7128 Yes 2
1
1 Yes
Yes Yes
2 2nd Floor
886 7088 No 2
2
1 Yes
Yes Yes
3 1st Floor
915 11346 No 0
0
1 Yes
No No
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Raised Floor
Main w_
891 ft2
21
0 0.5 0.5
2 Raised Floor
2nd Floor — —r
886 ft2
0
0 0.5 0.5
3 Slab -On -Grade Edge Insulatio
1 st Floor 150 ft 0
915 ft2
—
0 0 1
ROOF
/
Roof Gable Roof
Solar
SA Emitt
Emitt Deck Pitch
V # Type Materials Area Area Color
Absor.
Tested
Tested Insul. (deg)
1 Hip
Metal 913 ftz 0 ft2 Unfinishe
0.96
No 0.4
No 21 14
ATTIC
V # Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Unvented 0 886 ft2
N N
1/1812018 6:01 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented) 2nd Floor
21
Blown
886 ft2
0.11
Wood
2
Cathedral/Single Assembly (Unvented Main
0
Blown
891 ft2
0.11
Wood
3
Knee Wall (Unvented) 1st Floor
0
Blown
285 ft2
0.11
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar
Belo
Space
w
1
S
Exterior
Concrete Block - Int Insul Main
4
17
9
12
5
220.4 ft2
0 0.75
0
2
W
Exterior
Concrete Block - Int Insul Main
4
13
10
12
5
171.8 ft2
0 0.75
0
3
S
Exterior
Concrete Block - Int Insul Main
5
12
6
8
0
100.0 ft2
0 0.75
0
4
W
Exterior
Concrete Block - Int Insul Main
4
24
8
192.0 ft2
0 0.75
0
5
N
Exterior
Concrete Block - Int Insul Main
4
22
3
8
178.0 ft2
0 0.75
0
6
N
Exterior
Concrete Block - Int Insul Main
4
12
5
8
99.3 ft2
0 0.75
0
7
E
Exterior
Concrete Block - Int Insul Main
4
47
10
8
382.7 ft2
0 0.75
0
8
E
Exterior
Concrete Block - Int Insul Main
4
29
11
8
0
239.3 ft2
0 0.75
0
9
S
Exterior
Concrete Block - Int Insul Main
4
13
8
0
104.0 ft2
0 0.75
0
10
E
Exterior
Concrete Block - Int Insul Main
4
4
6
8
0
36.0 ft2
0 0.75
0
11
S
Exterior
Concrete Block - Int Insul2nd Floor
4
15
8
8
125.3 ft2
0 0.75
0
12
W
Exterior
Concrete Block - Int Insul2nd Floor
4
24
8
192.0 ft2
0 0.75
0
13
N
Exterior
Concrete Block - Int Insul2nd Floor
4
22
3
8
178.0 ft2
0 0.75
0
14
N
Exterior
Frame - Wood 2nd Floor
19
7
3
8
58.0 ft2
0 0.75
0
15
N
Exterior
Frame - Wood 2nd Floor
19
6
1
8
48.7 ft2
0 0.75
0
16
S
Garage
Frame - Wood Main
11
12
6
8
0
100.0 ft2
0 0.75
0
_ 17
E
Garage
Frame - Wood Main
11
8
7
8
0
68.7 11:2
0 0.75
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Insulated Main
None
.28
3
6 8
20 ft2
2
N
Insulated 2nd Floor
None
.25
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Ornt ID
Frame Panes NFRC
U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
1
S 3
Metal Single (Tinted) Yes
0.65
0.25
12.8 ft2
1 ft 0 in
10 ft 3 in
Drapes/blinds
None
2
W 4
Metal Double (Tinted) Yes
0.65
0.25
16.2 ft2
1 ft 0 in
10 ft 3 in
Drapes/blinds
None
3
N 5
Metal Double (Tinted) Yes
0.65
0.25
6.9 ft2
1 ft 0 in
10 ft 3 in
Drapes/blinds
None
4
N 6
Metal Double (Tinted) Yes
0.65
0.25
23.2 ft2
1 ft 0 in
10 ft 3 in
Drapes/blinds
None
5
S 11
Metal Double (Tinted) Yes
0.65
0.25
12.8 ft2
1 ft 0 in
0 ft 6 in
Drapes/blinds
None
1/18/2018 6:01 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
128.1 ft2
128.1 ft2
24 ft 8 ft 0
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.000356
1658.5 91.05 171.24 .3198 7
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
Electric Strip Heat
None
COP:1 4 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit
Split
SEER: 16 37 kBtu/hr 1110 cfm 0.8 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.92 40 gal 50 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ft2
DUCTS
/
V #
— Supply ---
Location R-Value Area
— Return — Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT ON RLF
HVAC #
Heat Cool
1
Attic 6 50 ft2
Attic
10 ft2 Prop. Leak Free Garage -- cfm 53.3 cfm 0.03 0.50
1 1
1/18/2018 6:01 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM ,K405-2014
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan
HeatinH Jan
Feb
Feb
Mar
Mar
ki
Apr
Apr
f i
May X Jun
May 4 l Jun
Jui
n Jul
Au
r� Auri
Se [
Sep [ ]Oct
Oct
Nov
Nov
ki
Dec
Dec
Ventin Jan
Feb
Mar
Pc] Apr
[
May [
Jun
Jul
Aug
Se [X]
Oct
Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MECHANICAL VENTILATION
Type
Supply CFM
Exhaust CFM
Fan Watts
HRV
Heating System
Run Time Cooling System
None
0
0
0
1 - Electric Strip Heat
0%
1 - Central Unit
1/18/2018 6:01 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5