Loading...
HomeMy WebLinkAboutEPL Display CardFORM' R405-2014 p; ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the EnergyPerformance Index, the more efficient the home. 10725 SOUTH OCEAN DRIVE #482, JENSEN BEACH, FL, 34957 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete -Block - Int Insul, Exterior R=4.0 2118.80 ft2 b. Frame - Wood, Adjacent R=11.0 168.67 ftz 3. Number of units, if multiple family 1 c. Frame - Wood, Exterior R=19.0 106.67 ft2 4. Number of Bedrooms 3 d. other (see details) R= 100.00 ft2 5. Is this a worst case? No 10. Ceiling Types Insulation Area a. Cathedral/Single Assembly (Unvented) R=0.0 891.00 ft2 6. Conditioned floor area (ft2) 1777 b. Roof Deck (Unvented) R=21.0 886.00 ft2 7. Windows" Description Area c. other (see details) R= 285.00 ft2 a. U-Factor: Dbl, U=0.65 59.08 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: Garage R ft2 6 50 SHGC: SHGC=0.25 b. U-Factor. Sgl, U=0.65 - 12.85 ft2 SHGC: SHGC=0.25 12. Cooling systems kBtu/hr Efficiency c.. U-Factor. N/A ft2 a. Central Unit 37.0 SEER:16.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr SHGC: Efficiency a. Electric Strip Heat 4.0 Area Weighted Average Overhang Depth: 1.000 ft. COPA.00 Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 ' 915.00 ft2 a. Electric EF: 0.92 b. Raised Floor R=21.0 891.00 ft2 b. Conservation features c. other (see details) R= 886.00 ft2 None 15. Credits CF, CV, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: )� Date: Address of New Home: S City/FL Zip:�,J Z-d 7` ftZ 0 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/18/2018 6:06 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 I / FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: SHERRY ANDERSON Builder Name: Street: 10725 SOUTH OCEAN DRIVE #482 Permit Office: ST. LUCIE CO. City, State, Zip: JENSEN BEACH , FL, 34957 Permit Number: Owner: SHERRY ANDERSON Jurisdiction: 661100 Design Location: FL, Fort Pierce County:: ST. LUCIE (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2494.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.0 2118.80 ft2 b. Frame - Wood, Adjacent R=11.0 168.67 ft2 3. Number of units, if multiple family 1 c. Frame - Wood, Exterior R=19.0 106.67 ft2 4. Number of Bedrooms 3 d. other (see details) R= 100.00 ft2 5. Is this a worst case? No 10. Ceiling Types (2062.0 sqft.) Insulation Area a. Cathedral/Single Assembly (Unvented) R=0.0 891.00 ft2 6. Conditioned floor area above grade (ft2) 1777 b. Roof Deck (Unvented) R=21.0 886.00 ft2 Conditioned floor area below grade (ft2) 0 c. other (see details) R= 285.00 ft2 11. Ducts R ft2 7. Windows(71.9 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 50 a. U-Factor: Dbl, U=0.65 59.08 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 12.85 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 37.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 4.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (2692.0 sqft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 915.00 ft2 9 b. Conservation features b. Raised Floor R=21.0 891.00 ft2 None c. other (see details) R= 886.00 ft2 15. Credits CF, CV, Pstat Glass/Floor Area: 0.040 Total Proposed Modified Loads: 74.96 PASS Total Baseline Loads: 80.50 1 hereby certify that the plans and specifications covered by Review of the plans and c,04E ST,1A this calculation are in compliance with7thedda Energy specifications covered by this tiO Code. calculation indicates compliance �O with the Florida Energy Code. �r,�r"� - °f �,;:•'���� PREPARED BY: DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 * �, I hereby certify thZ his uilding, as designed, is in compliance Florida Statutes. ✓�, with the Florida Energy Code. a , C'OD W'E OWNER/AGENT' BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 On for whole house. 1/18/2018 6:04 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: SHERRY ANDERSON Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1777 Lot # Owner: SHERRY ANDERSON Total Stories: 2 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 10725 SOUTH OCEAN Permit Office: ST. LUCIE CO. Cross Ventilation: Yes County: ST. LUCIE Jurisdiction: 661100 Whole House Fan: No City, State, Zip: JENSEN BEACH , Family Type: Single-family FL, 34957 New/Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 2692 25562 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 891 7128 Yes 2 1 1 Yes Yes Yes 2 2nd Floor 886 7088 No 2 2 1 Yes Yes Yes 3 1 st Floor 915 11346 No 0 0 1 Yes No No FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Raised Floor Main 891 ft2 21 0 0.5 0.5 2 Raised Floor 2nd Floor M- _-_ 886 ft2 0 0 0.5 0.5 3 Slab -On -Grade Edge Insulatio 1 st Floor 150 ft 0 915 ft2 --- 0 0 1 ROOF V Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 913 ft2 0 ft2 Unfinishe 0.96 No 0.4 No 21 14 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 886 ft2 N N 1/18/2018 6:01 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORAM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) 2nd Floor 21 Blown 886 ft2 0.11 Wood 2 Cathedral/Single Assembly (Unvented Main 0 Blown 891 ft2 0.11 Wood 3 Knee Wall (Unvented) 1st Floor 0 Blown 285 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below Ornt TO Wall Type1 S Exterior Concrete Block - Int Insul Main 4 17 9 12 5 220.4 ft2 0 0.75 0 _ 2 W Exterior Concrete Block - Int Insul Main 4 13 10 12 5 171.8 ft2 0 0.75 0 3 S Exterior Concrete Block - Int Insul Main 5 12 6 8 0 100.0 ft2 0 0.75 0 _ 4 W Exterior Concrete Block - Int Insul Main 4 24 8 192.0 ft2 0 0.75 0 _ 5 N Exterior Concrete Block - Int Insul Main 4 22 3 8 178.0 ft2 0 0.75 0 -6 N Exterior Concrete Block - Int Insul Main 4 12 5 8 99.3 ft2 0 0.75 0 _ 7 E Exterior Concrete Block - Int Insul Main 4 47 10 8 382.7 ft2 0 0.75 0 8 E Exterior Concrete Block - Int Insul Main 4 29 11 8 0 239.3 ft2 0 0.75 0 _ 9 S Exterior Concrete Block - Int Insul Main 4 13 8 0 104.0 ft2 0 0.75 0 10 E Exterior Concrete Block - Int Insul Main 4 4 6 8 0 36.0 ft2 0 0.75 0 _ 11 S Exterior Concrete Block - Int Insul2nd Floor 4 15 8 8 125.3 ft2 0 0.75 0 12 W Exterior Concrete Block - Int Insul2nd Floor 4 24 8 192.0 ft2 0 0.75 0 13 N Exterior Concrete Block - Int Insul2nd Floor 4 22 3 8 178.0 ft2 0 0.75 0 14 N Exterior Frame - Wood 2nd Floor 19 7 3 8 58.0 ft2 0 0.75 0 15 N Exterior Frame - Wood 2nd Floor 19 6 1 8 48.7 ft2 0 0.75 0 _ 16 S Garage Frame - Wood Main 11 12 6 8 0 100.0 ft2 0 0.75 0 _ 17 E Garage Frame - Wood Main 11 8 7 8 0 68.7 ft2 0 0.75 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated Main None .28 3 6 8 20 ft2 2 N Insulated 2nd Floor None .25 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 S 3 Metal Single (Tinted) Yes 0.65 0.25 12.8 ft2 1 ft 0 in 10 ft 3 in Drapes/blinds None 2 W 4 Metal Double (Tinted) Yes 0.65 0.25 16.2 ft2 1 ft 0 in 10 ft 3 in Drapes/blinds None 3 N 5 Metal Double (Tinted) Yes 0.65 0.25 6.9 ft2 1 ft 0 in 10 ft 3 in Drapes/blinds None 4 N 6 Metal Double (Tinted) Yes 0.65 0.25 23.2 ft2 1 ft 0 in 10 ft 3 in Drapes/blinds None 5 S 11 Metal Double (Tinted) Yes 0.65 0.25 12.8 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None Ill8/2018 6:01 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 128.1 ft2 128.1 ft2 24 ft 8 ft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1658.5 91.05 171.24 .3198 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPA 4 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 37 kBtu/hr 1110 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 40 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V # --- Supply --- Location R-Value Area — Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 50 ft2 Attic 10 ft2 Prop. Leak Free Garage — cfm 53.3 cfm 0.03 0.50 1 1 1/18/2018 6:01 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan HeatinHJan Feb HFeb Mar MMar A r E Apr I IMa May Jun Jun Jul Jul Au Aug ri Se Sep Oct Oct Nov Nov Dec Dec Ventin Jan Feb Mar [X] A r May Jun Jul Au Se [x Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 1 - Electric Strip Heat 0% 1 - Central Unit 1/18/2018 6:01 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5