ICC-ES Report
SECTION: 08 95 43—VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: SMARTVENT PRODUCTS, INC. 430 ANDBRO DRIVE, UNIT 1 PITMAN, NEW JERSEY 08071 EVALUATION SUBJECT: SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #1540-510; #1540-511; #1540-570; #1540-574; #1540-524; #1540-514 'CC P 1CC • 'CCck 91 tY PMG LlSTM Look for the trusted marks of Conformity! "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPQ Award in Excellence" A Subsidiary of Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC,' Evaluation Service, LLC, express or implied, as Im AWA=rMWPsw= 0 to any finding or other matter in this report, or as to any product covered by the report s F=Mft=N om Copyright 0 2016 ICC Evaluation Service, LLC. All rights reserved. IMES Evaluation Report ESR-2074 Reissued February 2015 Revised May 2016 This report is subject to renewal February 2017. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 08 00 00—OPENINGS allowing the door to rotate out of the way and allow flow. Section: 08 95 43 -Vents/Foundation Flood Vents The water level stabilizes, equalizing the lateral forces. Farh unit is fahrerated from stainless steel Smart Vente REPORT HOLDER: Automatic Foundation Flood Vents are available in various models and sizes as described in Table 1. The SMARTVENT PRODUCTS, INC. SmartVENT Stacking Model #1540,511 and FloodVENT"' 430 ANDBRO DRIVE, UNIT 1 Stacking Model #1540-521 units each contain two PITMAN, NEW JERSEY 08071 vertically arranged openings per unit. (877) 441-8368 www.smartvent.com infoCa)smartventcom EVALUATION SUBJECT: SMART VENT' AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1640-520; #1540.521; #1640510; #1540-511; #1540-670; #1540574; #1540524; #1540514 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2015, 2012, 2009 and 2006 .International Building Code® (IBC) ■ 2015, 2012, 2009 and 2006 Intemationa/ Residential Code® (IRC) ■ 2013 Abu Dhabi Intemationa/ Building Code (ADIBC)t t'rhe ADIBC is based on the 2009 IBC. 2009 IBC code sections referenced in this report are the same sections in the ADIBC. Properties evaluated: ■ Physical operation ■ Water flow 2.0 USES The Smart Vent® units are engineered mechanically operated flood vents (FVs) employed to equalize hydrostatic pressure on walls of enclosures subject to rising or falling flood waters. Certain models , also allow natural ventilation. 3.0 DESCRIPTION 3.1 General: When subjected to rising water, the Smart Vent® FVs internal floats are activated, then pivot open to allow flow in either direction to equalize water level and hydrostatic pressure from one side of the foundation to the other. The FV pivoting door is normally held in the closed position by a buoyant release device. When subjected to rising water, the buoyant release device causes the unit to unlatch, 3.2 Engineered Opening: The FVs comply with the design principle noted in Section 2.7.2.2 and Section 2.7.3 of ASCE/SEI 24-14 [Section 2.6.2.2 of ASCE/SEI 24-05 (2012, 2009, 2006 IBC and IRC)] for a maximum rate of rise and fall of 5.0 feet per hour (0.423 mm/s). In order to comply with. the engineered opening requirement of ASCE/SEI 24, Smart Vent FVs must be installed in accordance with Section 4.0. 3.3 Ventilation: The SmadVENT' Model #1540-510 and SmartVENTO Overhead Door Model #1540-514 both have screen covers with 1/4-inch-by-1/4-inch (6.35 by 6.35 mm) openings, yielding 51 square inches (32 903 mm) of net free area to supply natural ventilation. The SmartVENT® Stacking Model #1540-511 consists of two Model #1540-510 units in one assembly, and provides 102 square inches (65 806 mm) of net free area to supply natural ventilation. Other FVs recognized in this report do not offer natural ventilation. 4.0 DESIGN AND INSTALLATION SmartVENT® and FloodVENT' are designed to be installed into walls or overhead doors of existing or new construction from the exterior side. Installation of the vents must be in accordance with the manufacturer's instructions, the applicable code and this report Installation clips allow mounting in masonry and concrete walls of any thickness. In order to comply with the engineered opening design principle noted in Section 2.7.2.2 and 2.7.3 of ASCE/SEI 24-14 [Section 2.6.2.2 of ASCE/SEI 24-05 (2012, 2009, 2006 IBC and IRC)], the Smart Vent® FVs must be installed as follows: ■ With a minimum of two openings on different sides of each enclosed area. ■ With a minimum of one FV for every 200 square feet (18.6 m2) of enclosed area, except that the SmartVENT' Stacking Model #1540-511 and FloodVENT® Stacking Model #1540-521 must be installed with a minimum of one FV for every 400 square feet (37.2 m2) of enclosed area. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or arty other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its rose, There is no is arranh- he ICY' Rvaluation Service, Lf.C, express or implied a to mrvfmdinl; or other matter in this report, or as to any product covered by the report. copyright © 2016 ICC Evaluation Service, LLC. All rights reserved. o Page lc of 3 ■ Below the b; ■ With the bi 12 inches grade or flo under each i 5.0 CONDITIOI The Smart Ver or are suitabie codes listed it following condi 5.1 The Smar With this a conflict and Trusted flood elevation. )m of the FV located a maximum of 5.4 mm) above the higher of the final and finished exterior grade immediately 5 OF USE a FVs described in this report comply with, alternatives to what is specified in, those Section 1.0 of -this report, subject to the t Vent® FVs must be installed in accordance report, the applicable code and 'the irer's installation instructions. In the event of the instructions in this report govern. 2of3 5.2 The Smart Vent® FVs must not be used in the place of "breakaway walls" in coastal high hazard areas, but are permitted for use in conjunction with breakaway walls in other areas. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Mechanically Operated Flood Vents (AC364), dated August 2015. 7.0 IDENTIFICATION The Smart VENT® models recognized in this report must be identified by a label bearing the manufacturer's name (Smartvent Products,' Inc.), the model number, and the evaluation report number (ESR-2074). TABLE 1—MODEL SIZES MO EL NAME MODEL NUMBER MODEL SIZE (in.) COVERAGE (sq. ft.) ,R2910;VEN n �1540 52Q " q15� /4 X Z.;/4 ,. >,.200 SmartVENT® 1540-510 153/4' X 73/4" 200 FloodVENT® Ov rhead Door 1540-524 15%' X 73/4" 200 SmartVENT®'Ov rhead Door 1540-514 1,53/a' X 73/4" 200 Wood Wall Flooc VENT® 1540-570 , 14" X 83/4' 200 Wood Wall Flooc VENT® Overhead Door 1540-574 14" X 83/4' 200 SmartVENT® Ste. cker 1540-511 16" X 16" 400 FloodVent Stac er 1 1640-521 16" X 16" 400 rur an i mcn = Go. i mm; 1 square toot = m- Q