Technical Product Data
.411'. �. Icynene MD=C=200 TM Technical Product Data THERMAL INSULATION AND AIR BARRIER ICC-ES ESR-3199 Specification Section: 07 21 19 Foamed -in -Place Insulation, 07 27 00 Air Barriers PRODUCT DESCRIPTION Icynene MD-C-200 is a closed cell spray applied polyurethane foam insulation and air barrier material suitable for buildings in accordance with the IRC and the IBC including Type I, II, III, IV and V construction. It delivers high R-value and Class 11 water vapor permeance required in certain climate zones. The product is for use as a thermal insulation and air barrier in: • exterior walls as continuous insulation • foundation walls • wall cavities • floor assemblies © ceiling assemblies • attics (vented and unvented) • crawl spaces (vented and unvented) • floor slabs PROPERTIES OF CURED FOAM Characteristic Test Method Value Core Density ASTM D 1622 2.4 Ib/ft3 Color Cream Aged Thermal R-6.6 Resistance: at 1" ---------------- at 2" (Calculated) ---------------- ASTM C 518 ---------------- R-13 ---------------- at 3" (Calculated) ---------------- R-20 ---------------- at 31/2" R-23 Air Permeance ASTM E 2178 < 0.02 Us.m2 at 1.4" Water Vapor ASTM E 96 0.9 perm at 1.5" Permeance Dimensional Stability ASTM D 2126 6% at 158°F at 7 days (% Volume) and 97% RH Compressive Strength ASTM D 1621 28 Ibfn2 Tensile Strength ASTM D 1623 46 Ib4n2 Closed Cell Content ASTM D 6226 97% (% Volume) Fungus Testing ASTM C 1338 No Growth BURN CHARACTERISTICS Surface Burning at Class 1 4 inches: ---------------- Flame Spread Index ASTM E84 ---------------- < 25 ---------------- Smoke Development ---------------- < 450 Commercial Fire NFPA 285 Assembly Passed* Resistance Commercial Fire ASTM E 119 1,2 & 3 Hour Ratings* Resistance DC 315 Thermal NFPA 286 > 15 minutes Barrier Wall & Ceiling No Limit for Code - Application Maximum NFPA 286 Prescribed Thermal Thickness Barrier Attic & Crawl ACC377 Walls - 6" Space Walls & Roof Appendix X Roof - 8" Uncoated Thickness *consult Icynene Engineering Department for details. Icynene MD-C-200"" is a combustible product and is therefore, consumed by flame, but will not sustain flame upon removal of the flame source. It leaves a charred foam residue. It will not melt or drip. Icynene MD-C-200'" must be covered with 112" of gypsum board, DC-315 intumescent paint coating at 24 wet mils or approved thermal barrier. Icynene MD-C-200"" is subject to all applicable National/ State and County building codes regarding fire prevention. Requirements for Thermal Barrier and Ignition Barrier coverings must be met as per the applicable building code as required by the authority having jurisdiction. AIR BARRIER/ MECHANICAL VENTILATION • Icynene MD-C-200" has been evaluated and listed by the Air Barrier Association of America (ABAA) as an air barrier material. • Icynene MD-C-200' fills any shaped cavity, and adheres to most construction materials, creating assemblies with very low air permeance. • Additional interior or exterior air infiltration protection is subject to applicable codes. • All buildings insulated and air sealed with Icynene MD-C-200" must be designed to include adequate mechanical ventilation/ outdoor air supply for optimum IAQ (Indoor Air Quality). • For mechanical ventilation see ASHRAE Standard 62 — Ventilation for Acceptable Indoor Air Quality or any other acceptable good engineering practice. RECEIVED JAN 10 2018 ST. Lucie County, Permitting, sue emvr I(YNENE° The Evolution of Insulation 3 VATER VAPOR PERMEANCE & ABSORPTION • Icynene MD-C-200- is a Class II vapor retarder, at 1112" thickness, which reduces the amount of moisture that can diffuse through the insulation. • Icynene MD-C-200- meets FEMA criteria for resisting water absorption. • It is resistant to moisture allowing it to be used below the base flooding elevation in flood prone areas. ENVIRONMENTAL AND HEALTH • Icynene MD-C-200- is California Department of Public Health EHLB v1.1-2010 Emissions Specification Section 01350 compliant for offices and classrooms. INSTALLATION • Icynene MD-C-200" is installed by a network of Licensed Dealers, trained in its installation. • Maximum thickness per pass is 2 inches. Wait until first layer cools before applying a second layer/lift over the initial layer/ lift. A wait time of 10 to 20 minutes is recommended. • This product should not be installed within 3" (76 mm) of heat emitting devices, (or as specified by Code) where the temperature is in excess of 180°F, in accordance with applicable codes. • It can be installed in hot, humid or freezing conditions. Minimum substrate temperature for application is 25°F (-4°C) • Surface preparation is generally not necessary. • Within seconds, the foaming process is complete. TECHNICAL Icynene Licensed Dealers and Icynene Inc. provide support on both technical and regulatory issues. Architectural specifications in CSI 3-Part format and design details are available at our website at www. icynene.com, REGULATORY • ESR-3199 has been issued by the ICC-ES for Icynene MD-C- 200-. • Icynene MD-C-200- has been tested as per the requirements of the International Code Council Evaluation Service's AC377 Acceptance Criteria (November 2012). • Icynene MD-C-200'" meets ASTM C1029 Type II classification. • For regulatory issues concerning Icynene MD-C-200- contact Icynene at 800-758-7325. RELATED REFERENCES All physical properties were determined through testing by accredited third party agencies. Icynene Inc. reserves the right to change specifications in its effort of continuous improvement. Please confirm that technical data literature is current. PACKAGING AND STORAGE • Packaging - 55 US gallon, closed top steel drums • Component 'A' — 520 lb. per drum. Base Seal® MDI • Component 'B' — 480 lb. per drum. Icynene MD-C-200" — Resin HANDLING AND SAFETY 0 Icynene MD-C-200' (Component A and Component B) For information on Health and Safety, refer to the Spray ideally should be stored between 60°F (15°C) and 85°F Polyurethane Foam Alliance Health and Safety guidance documents (30°C). at www.spraypolyurethane.com. 0 Component A should be protected from freezing. • Shelf life is 6 months. AVAILABILITY Contact Icynene Inc. at 800-758-7325 or visit our website at www.icynene.com. WARRANTY WHEN INSTALLED PROPERLY IN ACCORDANCE WITH INSTRUCTIONS, THE COMPANY WARRANTS THAT THE PROPERTIES OF THE PRODUCT MEET PRODUCT SPECIFICATIONS AS OUTLINED IN THIS TECHNICAL DATA SHEET. SAVE AND EXCEPT ANY EXCLUSIONS REFERENCED IN THE WARRANTY. i� I ( Y N E N E9 The Evolution of Insulation Telephone: 905.363.4040 Toll Free: 800.758.7325 www.Icynene.com inquiry@icynene.com SL-223 • Updated June 2016 r Health & Safety Geriified Sprayer Icynene spray foam insulation products have an excellent health and safety record spanning more than 425,000 projects over more than 25 years. Nonetheless, safe handling practices during and immediately following installation are required to eliminate the possibility of health effects from exposure to isocyanates. Asthma, other lung problems, and irritation of the nose and throat can result from inhalation of isocyanates. Direct contact with the skin and eyes can result in irritation. Different individuals will react differently to the same exposures; some will be more sensitive than others. Severe asthma attacks have been reported in some sensitized workers exposed repeatedly to isocyanates while not wearing proper protective equipment. Some reports indicate a reaction and sensitization can occur following a single, sustained occupational exposure to isocyanates without proper protective equipment above the OSHA permissible exposure limit. But sensitization might not occur immediately in some individuals. Consistent use of personal proper protective equipment to prevent exposure during spraying and within the 24 hour -period after spraying is completed is critical to eliminating the health hazard. Once sensitization has occurred, a worker might not be able work safely with spray foam insulation again. Sprayers, sprayer helpers, and anyone else present during spraying or within 24 hours after spraying is complete: You must wear proper Personal Protective Equipment (PPE) at all times during spray, including full -body -coverage, chemical -protective clothing and a NIOSH-certified respirator with fresh air supply. While spraying and for 24 hours after spraying is completed, no one must be allowed within 50 feet of the sprayed foam without wearing this type of PPE at all -times. Adequate active, negative pressure ventilation (exhaust fans) of the job site must be in place during spray and for 24 hours after spray is complete. EXCEPTION: For installations of low VOC products Icynene Classic Max, Icynene ProSeal and Icynene ProSeal LE in the United States ONLY, re-entry is permitted after 1 hour** and re - occupancy of the job site is permitted after 2 hours** provided that ventilation rates are followed as recommended on this page. Independent studies and third party toxicologist verification indicates that when the prescribed ventilation rates and periods are followed, Icynene spray foam insulation is safely cured. Icynene Inc. 6747 Campobello Road Mississauga, Ontario L5N 21-7 Canada Ph:1.800.758.7325 • ICYNENE.COM kll0`1 NSI I 11, 1 ro- W" " WEAR PROPER PERSONAL PROTECTIVE EQUIPMENT AT ALL ' TIMES ON PREMISES DURING SPRAYING AND WITHIN 24 HOURS • AFTER SPRAY IS COMPLETE RE-ENTRY AND RE -OCCUPANCY PERIODS Times based upon ventilating during and after a spray application. Re-entry period for Ventilation Rate sprayers, Re -occupancy (Air Changes helpers, period for all per Hour) informed trade others workers and contractors At 0.3 ACH 24 hours 24 hours At 1.0 ACH 12 hours* 24 hours At 10.0 ACH 4 hours* 24 hours At 10.0 ACH 1 hour** 2 hours** For Icynene aw§G Max At 40.0 ACH 1 hour** 2 hours** * Twelve (12) and four (4) hour re-entry for trades applies to all Icynene products sold in the United States. ** One (1) hour re-entry and two (2) hour re -occupancy applies only to low VOC products: • Icynene Classic Max at 10 ACH • Icynene ProSeal / Icynene ProSeal LE at 40 ACH I(YNENE' SL-505 • Updated April 2017 The Evolution of Insulation wealth & Safety --ul ertif ied Sprayer Icynene spray foam insulation products have an excellent health and safety record spanning more than 425,000 projects over more than 25 years. Nonetheless, safe handling practices during and immediately following installation are required to eliminate the possibility of health effects from exposure to isocyanates. Asthma, other lung problems, and irritation of the nose and throat can result from inhalation of isocyanates. Direct contact with the skin and eyes can result in irritation. Different individuals will react differently to the same exposures; some will be more sensitive than others. Severe asthma attacks have been reported in some sensitized workers exposed repeatedly to isocyanates while not wearing proper protective equipment. Some reports indicate a reaction and sensitization can occur following a single, sustained occupational exposure to isocyanates without proper protective equipment above the OSHA permissible exposure limit. But sensitization might not occur immediately in some individuals. Consistent use of personal proper protective equipment to prevent exposure during spraying and within the 24 hour -period after spraying is completed is critical to eliminating the health hazard. Once sensitization has occurred, a worker might not be able work safely with spray foam insulation again. Sprayers, sprayer helpers, and anyone else present during spraying or within 24 hours after spraying is complete: You must wear proper Personal Protective Equipment (PPE) at all times during spray, including full -body -coverage, chemical -protective clothing and a NIOSH-certified respirator with fresh air supply. While spraying and for 24 hours after spraying is completed, no one must be allowed within 50 feet of the sprayed foam without wearing this type of PPE at all times. Adequate active, negative pressure ventilation (exhaust fans) of the job site must be in place during spray and for 24 hours after spray is complete. EXCEPTION: For installations of low VOC products Icynene Classic Max, Icynene ProSeal and Icynene ProSeal LE in the United States ONLY, re-entry is permitted after 1 hour** and re - occupancy of the job site is permitted after 2 hours** provided that ventilation rates are followed as recommended on this page. Independent studies and third party toxicologist verification indicates that when the prescribed ventilation rates and periods are followed, Icynene spray foam insulation is safely cured. Icynene Inc. 6747 Campobello Road Mississauga, Ontario L5N 21-7 Canada Ph:1.800.758.7325 • ICYNENE.COM 0 WEAR PROPER PERSONAL PROTECTIVE EQUIPMENT AT ALL TIMES ON PREMISES DURING SPRAYING AND WITHIN 24 HOURS AFTER SPRAY IS COMPLETE RE-ENTRY AND RE -OCCUPANCY PERIODS Times based upon ventilating during and after a spray application. Re-entry period for Ventilation Rate sprayers, Re -occupancy (Air Changes helpers, period for all per Hour) informed trade others workers and contractors At 0.3 ACH 24 hours 24 hours At 1.0 ACH 12 hours* 24 hours At 10.0 ACH 4 hours* 24 hours At 10.0 ACH 1 hour** 2 hours** For Icynene Classic Max At 40.0 ACH 1 hour** 2 hours** * Twelve (12) and four (4) hour re-entry for trades applies to all Icynene products sold in the United States. ** One (1) hour re-entry and two (2) hour re -occupancy applies only to low VOC products: • Icynene Classic Max at 10 ACH • Icynene ProSeal / Icynene ProSeal LE at 40 ACH u� ICYNENEO SL-505 • Updated April 2017 The Evolution of Insulation