Loading...
HomeMy WebLinkAboutEvaluation ReportEVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION '26 GA. 5V CRIMP PANEL' FLORIDA BUILDING CODE 5TA EDITION (2014) FLORIDA PRODUCT APPROVAL FL 14645.3-R2 ROOFING THESE PLANS AND ALL PROPOSED WORK METAL ROOFING ARE SUBJECT TO ANY COVECTIONS REOUIRED BY FIELD INSKCTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. Prepared For: Metal Sales Manufacturing Corporation O 545 South 31 Street, Suite 400 Louisville, KY 40202 s Telephone: (502) 855-4300 T. L COUNTY Fax: (502) 855-4290 BUILDINGING DIVISION REVIEi4/EI) FOR CO CE REVI D BY / DATE . — % — PLANS A D PERMIT MUST BE KEPT ON JOB OR Prepared By: NO INSPECTION WILL BE MADE Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer #62240 1216 N Lansing Ave Suite C SC3VW 38 I1IM N01.103dSNl O (' d0 sor NO 1d3N 381S \ 11W113d aNV SN 31W AS a3M31A3d 401SIAIa 014mi 18 AlNf100 310fY1 as ., Tulsa, OK 74106 Telephone: (918); 492-5992 FAX: (866) 366-1543 This report consists of Evaluation Report (3 Pages including cover) Installation Details (1 Page) CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBOM OF THE CON RACiOR OF RECORD Report No. C2010-3 Date: 3.27.15 V%%** SOCK No 62 :O•:, STATE ��A�`Sj•<OR1 HLEw4 ... Manufacturer: Product Name: Panel Description: Materials: Deck Description: Deck Attachment: (Minimum) New Underlayment: rL I 645.E-1tl C2010-3 3.27.15 age 2 of 3 Metal Sales Manufacturing Corporation SV-Crimp 24" wide coverage with (5) 1/2" high ribs Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Min. 19/32" thick plywood for new and existing Designed and installed as per FBC 2014. 8d x 2.5" long ring shank nails or #8 x 2" long wood screws 6" O.C. in the plywood field and @ 4" o.c. at edges I Minimum underlayment as per FBC 2014 Section 1 07.4.5.1. Required for new construction and optional for reroofing con truction. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For (Optional) construction only. Slope: 1/2:12 or greater in accordance with FBC 2014 Section 1507 .2 Design Uplift Pressure: 41.6 psf @ fastener spacing of 36" o.c. (Factor of Safety = 2) :748 fs ekng:—sIf�� enof 16" o..c.; I 196.75 psf @ fasten spacing of 8" o.c. Fastener Pattern: Type: 49-16 or #10-14 hex head wood screws with sealed washer Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8". ,.c._acanl wi i �At,,,p�a en bends @ 6" oross pe ��4t�nferrxiediat� e� @`i�" o.c. across panel'widt Test Standards: Roof assembly tested in accordance with TAS 125-03 Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance vith FBC 2014 Section 1507.4 Product Limitations: Design wind loads shall be determined for each project in a cordance with FBC 2014 Section 1609 or ASCE 7-10 using allowa le stress design. The maximum support spacing listed herein sha 1 not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scop of this Evaluation Report. Refer to FBC 2014.Section 1505 an current 1. '' } / �,4 Y � £�• �� J � ,1 YL 19645.3-R2 C2010-3 3.27.15 Page 3 of 3 approved roofing materials directory or ASTM E108/UL 90 report from an accredited laboratory for fire ratings of this product. Supporting Documents: TAS 125 Test Reports Farabaugh Engineering and Testing Inc Project No. T181-05, Reporting Date 7/21/05 (Tests #1 & 2 Project No. T240-09, Reporting Date 9/22/09 Architectural Testing, Inc. — West Palm Beach, FL (Formerly Hurricane Test Laboratory, LLQ Project No. 0103-0712-09, Reporting Date 9/1/09 EXISTING SHINGLES (OPTIONAL) NEW UNDERLAYMENT (REQUIRED ONLY FOR NEW CONSTRUCTION) EXISTING SHINGLES (OPTIONAL) EXISTING UNDERLAYMENT (OPTIONAL) NEW UNDERLAYMENT - (REQUIRED ONLY FOR N - W CONSTRUCTION) �CCI3FING SHINGLES -16 4UMNAL) z tram- —�- ( npIsTTI UNDERLAYMENT L) 5 NFW UNDFRIAYMFNT EACTMED AT DAAIE, n A'r - - -- ,.. . TRUSS AT MAX. 24" O.C. TYPICAL PANEL INSTALLATION X-SECTION #9-16 OR #10-14 WOODSCREWS WITH SELF SEALING WASHER AT MAXIMUM SPACING OF 36" O.C. 5V-CRIMP MIN 26 GA. - PLYWOOD D ETA I L 1 19/32" THICK (MIN.) /- #9-16 OR #10-14 WOODSCREWS / WITH SELF SEALING WASHER AT /1 MAXIMUM SPACING OF 36" O.C. 5V-CRIMP MIN 26 GA. `- PLYWOOD D ETAI L 2 19/32` THICK (MIN.) 5V-CRIMP ALLOWABLE UPLIFT PRESSURE FASTENER SPACING (IN) PRESSURE (PSF) 36 41.6 16 74.8 _ 8 196.75 GENERAL NOTES: 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.0169"). EFFECTIVE COVERING WIDTH OF PANEL = 24". 3. THE ROOF PANELS SHALL BE INSTALLED.OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS, 4 N U wO z I-c to c to H� M c3 w� toEn - c (< I4 N o- i to i� 1 or 1