HomeMy WebLinkAboutRoof Carport SpecificationsTABLE OF ROOF BEAT';' COLUMNS, PURLINS AP" GIRTS: 'HIS CARPORT STRUCTURE MEETS THE FLORIDA BUILDING CODE FOR A HEIGHT 8%6", 150 MPH, EXP. C. WIND SPEED. THE TABLES BELOW ARE BASED ON SIMULTANEOUS LOADING AS DEFINED'IN THE FLORIDA BUILDING CODE (FBC), CHAPTERS 16 AND 20, AND OTHER REFERENCES SUCH AS ALUMINUM ASSOCIATION OF FLORIDA (AAF). "GUIDELINES TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS". STRUCTURAL VALUES FOR EXTRUDED ALLOY 6005T5 ARE TAKEN FROM THE ALUMINUM DESIGN MANUAL, 2015 EDITION. TABLE 1 MAIN ROOF MEMBER SCHEDULE MEMBER -' MARK MANF. WEIGHT IWATERW THICKNESS ILENGTH DESIGN BASIS # I SKIN I POLY I SKIN I FT. L. PROD. APPR. POLY ROOF PANEL # 1 PRP1 I ELITE I 1 ALUM W 0.024 1"'IFL-1001, FL7561-R3, DWG. OR = 3-20-15 TABLE 2 MAIN MEMBER SCHEDULE, ____Fm_A_g_K_l MEMBER SIZE IMATERIALl TYPE I THICKNESS 1LENGTH DESIGN BASIS b x t I ALLOY I I W I F FT. COLUMN # 1 COLUMN # 2 CARRIER BEAM # 1 EDGE BEAM # 1 MID BEAM # 1 KNEE BRACE # 1 Cl 3x3-12 ALUM TUBE 0.125 0.125 8'-6" CALCULATION C2 3x3-12 ALUM TUBE 0.125 0.125 9'-3" CALCULATION CBI 2x7 ALUM SMB 0.550 0.120 8'-7" CALCULATION E131 2x3H ALUM HOLLOW. -, 0.090. 0.090 AV-0" CALCULATION.. MB1 2x3H ALUM HOLLOW 0.090 0.090 11'-0" CALCULATION KB1 2x3-7 ALUM HOLLOW ' 0.070 0.070 2'-10" • CALCULATION ADDITIONAL SITE SPECIFIC INFORMATION . NOTE:' AVERAGE THIS POLY ROOF CARPORT IS LOCATED IN A RESIDENTIAL COMMUNITY NORTH OF SAVANNA CLUB BLVD. AND EAST OF U.S. ROUTE 1 IN PORT ST. LUCIE. THE CARPORT HAS SOME OPEN AREAS AROUND IT. THE ENCLOSURE IS ABOUT 2500 FEET WEST OF THE SAVANNAS PRESERVE STATE PARK. PER THE EXPOSURE CATEGORIES' LISTED IN SECTION 1609.4.3 OF THE FLORIDA BUILDING CODE THIS ENCLOSURE SHALL CONSERVATIVELY BE CALLED AN EXPOSURE 'C'. ACCORDING TO THE COMPUTER PROGRAM "WINDSPEED BY LOCATION", A PRODUCT OF 'APPLIED TECHNOLOGY COUNCIL' THE DESIGN WIND LOAD REQUIREMENTS FOR A RISK CATEGORY I ENCLOSURE IN THIS LOCATION IS DICTATED BY A WIND SPEED OF 148 MPH. HENCE, THE DESIGN PARAMETERS BEING USED HERE ARE 150 MPH WIND LOAD, EXPOSURE 'C', RISK CATEGORY I. THE NEW POLY ROOF CARPORT IS BEING INSTALLED BECAUSE THE EXISTING CARPORT, WHICH WAS BUILT IN THE 1990S3 WAS DAMAGED DURING A RECENT HURRICANE IRMA THIS SEPTEMBER. THE FRONT IS 8'-6" HIGH AND THE REAR IS 9'-3" HIGH; WITH A RUN OF 11 FEET GIVES A SLOPE OF ABOUT 0.82 INCHES PER.FOOT. THE POLY ROOF CARPORT IS BEING BUILT ON AN EXISTING'NOMINAL 4" SLAB THAT IS IN GOOD CONDITION. THIS FOUNDATION IS ACCEPTABLE FOR THIS SCREEN ENCLOSURE. THE DESIGN DRAWING IS SHOWN ON SHEET 2. THE POLY ROOF CONNECTION DRAWINGS ARE SHOWN ON SHEETS 3. THE HOST STRUCTURE IS A MODULAR HOME SO 4TH WALL CONSTRUCTION FOR COMPOSITE ROOFS WILL BE USED. THEREFORE, THE COLUMNS, BRACING AND CONNECTIONS SHOWN ON SHEET 2 ARE THE SAME IN THE BACK AS IN THE FRONT EXCEPT THAT THE BACK IS 91NCHES HIGHER. THERE SHALL BE NO STRUCTURAL ATTACHMENT BETWEEN THE POLY ROOF CARPORT AND THE MOBILE HOME BUT IT IS ACCEPTABLE TO INSTALL FLASHING TO KEEP THE RAIN OUT. THE CARRIER BEAM TO COLUMN CONNECTION CAN BE MADE WITH 7" LONG CHANNELS AND FOURTEEN (14) #12 SMS, SEVEN (7) BETWEEN EACH CHANNEL AND COLUMN AND SEVEN (7) BETWEEN EACH CHANNEL AND EDGE OR MID BEAM, SIMILAR TO KNEE BRACE CONNECTIONS ON SHEET 2. ALSO, SEE OPTIONAL CONNECTION DRAWINGS BETWEEN COLUMNS AND CARRIER BEAMS BELOW. OPTIONAL CARRIER BEAM TO COLUMN CONNECTION BOLTED CONNECTION - OPTION # 1 THE ROOF BEAM CAN BE CONNECTED TO THE COLUMN WITH TWO 1/2" SS NUTS, BOLTS AND SS WASHERS. 2" WIDE CARRIER BEAM (CB) OR EDGE BEAM (EB) PLAN VIEW - CORNER COLUMN BOLTED CONNECTION - OPTION # 2 THE ROOF BEAM CAN BE CONNECTED TO THE COLUMN WITH TWO 1/2" SS NUTS, BOLTS AND SS WASHERS. 2" WIDE CARRIER BEAM (CB) OR EDGE BEAM (EB) PLAN VIEW - MIDDLE COLUMN SPECIFICATION NOTES AND DESIC PARAMETERS: THIS DESIGN COMPLIES WITH THE GUIDELINES DEFINED IN CHAPTERS 16 & 20 OF THE FLORIDA BUILDING CODE (FBC), 5TH EDITION (2014) BUILDING, USING THE ALLOWABLE STRESS DESIGN PRESSURES LISTED IN TABLE 2002.4 AND TABLE 2002.4A. THE AAF STANDARDS OF THE "GUIDELINES TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS" FOR TABLE 1 ARE APPLIED. A DESIGN BASICS: THIS POLY ROOF CARPORT IS A RISK CATEGORY I STRUCTURE. HEIGHT W-6", 150 MPH, EXP. 'C' B THE BUILDING CLASSIFICATION RISK CATEGORIES. ARE FROM FBC, TABLE 1604.5 AND AREA LOCATION WIND SPEED PER FBC, FIGURE 1609C. BUILDING CLASSIFICATION PER.TABLE 27.2-1, ASCE 7-10. C DESIGN PRESSURE: FOR SOLID ROOF @ 30.96 PSF PER TABLE 2002.4. D MAXIMUM HEIGHT: HEIGHTS HIGHER THAN LISTED ABOVE REQUIRE SITE -SPECIFIC DESIGN BY THE ENGINEER OF RECORD. E ALLOWABLE DEFLECTION: L 160 MINIMUM, AS SPECIFIED IN TABLE #1604.3 OF FBC. F CONTINUOUS LOAD PATH IS PROVIDED WITHIN THE CALCULATIONS USING ALLOWABLE STRESS DESIGN PRESSURES. MATERIALS (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD): A ALL EXTRUSION MATERIALS SHALL BE ALUMINUM ALLOY # 6005T5 OR # 6061T6; ALLOY # 6063T6 IS NOT ACCEPTABLE. B FASTENERS: ALUMINUM ALLOYS #2024-T4 & #7075-T6, DOUBLE CAD -PLATED STEEL, HOT -DIPPED GALVANIZED STEEL OR 300-SERIES STAINLESS STEEL. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE FOR SEPARATION OF DISSIMILAR MATERIALS AS DEFINED IN THE FBC. HE/SHE MAY IMPLEMENT ANY OF THE MEANS LISTED IN THESE SECTIONS. ALTERNATIVES MUST BE REVIEWED AND APPROVED IN WRITING BY THE ENGINEER OF RECORD PRIOR TO ANY INSTALLATIONS UTILIZING THE SUBJECT METHODS. C. SCREEN CLOTH: SHALL BE VINYL -COATED, WOVEN FIBERGLASS, MAXIMUM DENSITY OF 18 X 14, 58% OPEN MINIMUM. OTHER SCREEN DENSITY REQUIRE ADDITIONAL ENGINEERING CONSIDERATION. D ANY CONNECTION USED, THAT IS NOT SHOWN ON THESE SHEETS, MUST MEET ALL F F GUIDELINES. E MATERIAL UPGRADES (STRONGER AND/OR HIGHER GRADE MATERIALS) CAN BE SU MNWR.OR ATTACHMENTS F A 2x2 OR A 2x3 SNAP MEMBER CAN ALWAYS REPLACE A 2x2 OR A 2x3 HOLLOW MEMBERA220KCREMSIBILITY OF THE G WHEREVER SCREENING OR KICKPLATES ABUTS THE HOUSE OR CONCRETE THE MEMBER UIF '�aRD SCREENING OR KICKPLATE WILL BE A 1" x 2" x 0.046" O.B. OR STRONGER ALUMINUM MEMBER. HALL DOOR JAMS (DJ) SHALL BE 2" x 2" x 0.046" ALUMINUM MEMBERS OR STRONGER. I IT IS ALWAYS ACCEPTABLE TO ADD OR RELOCATE A SCREEN DOOR AS LONG AS THE COLUMNS ARE NOT DISTURBED. 3 ALL HOUSE FASCIA DETAILS, BOLTING OR SCREW SELECTIONS, BEAM SPLICE DETAILS, DIAGONAL "K" BRACING DETAILS, COLUMN TO BEAM DETAILS, STRUCTURAL GUTTER DETAILS, WALL AND FASCIA DETAILS, CORNER ANCHOR DETAILS, ROOF BRACING DETAILS, EAVE BRACING DETAILS, ETC., IF NOT EXPLICITLY OUTLINED ON THIS SPECIFICATION, SHALL BE IN ACCORDANCE WITH THE LATEST FBC EDITION, INCLUDING THE AAF. ALL Il�iE.�1dtQ1���MEEORKHE FBC (AAF) AND THERE INSTALLATION ARE THE RESPONSIBILITY OF THE CONtRA&UMECT TO ANY CC ARECTIONS 13EQUIRED BY FIELD INSPLCTORS THAT 4 WHERE APPLICABLE, THE LOCATION OF ALL "K" BRACING, WIND BRACING,0NIAfFCfWWTM-ONG WITH ANY DESIGN ABNORMALITY, ARE SHOWN AND/OR LISTED ON SHEET 2, THE "SI MOMP1015MVRWABLE CODES. 5 ALL STRUCTURES ERECTED ON CONCRETE SLABS AND / OR FOOTERS SHALL BE CALCULATED TO ASSURE THERE IS SUFFICIENT HOLD DOWN CAPABILITY TO MEET THE REQUIREMENTS OF A THE ENCLOSURE. 6 THE AVERAGE SPACING BETWEEN BEAMS IS SHOWN ON THE "SITE SPECIFIC DRAWING". THE ACTUAL SPACING BETWEEN ANY TWO BEAMS MUST BE THE LISTED SPACING, .+/- 2". THE OVERALL AVERAGE SPACING MUST BE EQUAL TO THE AVERAGE SPACING SHOWN ON THE "SITE SPECIFIC DRAWING". ALL SPACING MUST NEVER BE GREATER THAN 8.0' O.C. ST 7 IN LIEU OF "SITE SPECIFIC ENGINEERING" AN EXISTING SLAB SHALL MEET THE FOLLOWING REQUIREMENTS: A THE SLAB MUST BE IN GOOD CONDITION, 4" OR GREATER THICKNESS, CONSTRUCTED WITH REBAR, WIRE OR FIBER MESH. B ALL HOLD DOWN FASTENERS MUST BE NO MORE THAN 24" ON CENTER WITH MINIMUM ENGAGEMENT OF 2". 8 ALL NEW SLABS, WITH OR WITHOUT FOOTERS, SHALL MEET THE FOLLOWING REQUIREMENTS AS A MINIMUM: A SOIL MUST BE WELL COMPACTED AND TREATED FOR TERMITES PER COUNTY REQUIREMENTS, B 4" NOMINAL PATIO SLAB REQUIRES A VAPOR BARRIER IF THE SLAB ABUTS LIVING QUARTERS, C 4" NOMINAL PATIO SLAB WITH CONCRETE @ 3000 PSI (MIN.) WITH FIBER MESH OR REBAR AND WIRE, D SHALL BE SECURED TO EXISTING CONCRETE WITH #5 REBAR EVERY 24" O.C. TO AVOID SETTLEMENT, IF APPLICABLE. POLY ROOF CARPORT DWG. # RVC-2017-106, REV. 0 October 7, 2017 SHEET 1 OF 3 GENERIC DESIGN DATA HEIGHT V-6", 150 MPH, EXP. 'C' R V CONSTRUCTION 3318 COLUMBRINA CIRCLE PORT ST. LUCIE, FL 34952 OFFICE (772) 380-8253 LICENSE # CRC 1330965 LOCATION: NAME: HANSEN RESIDENCE ADDRESS: 8215 E. BITTERBUSH LANE CITY/STATE: PORT ST. LUCIE, FL 34952 COUNTY: ST. LUCIE EL � Cl>u. C ALZI.^Di !tcInv D FOR CO:NPWNCE DATE=-N-DE"R_N'9T PLA,ti:LT ST BE KEPT ON JOB ORN 9 ALL NEW PERIMETER FOOTERS SHALL MEET THE FOLLOWING REQUIREMENTS AS A MINIMUM: A SOIL MUST BE WELL COMPACTED AND TREATED FOR TERMITES PER COUNTY REQUIREMENTS, B CONCRETE @ 3000 PSI (MIN.) WITH ONE #5 REBAR FOR 8" x 8" AND TWO #5 REBAR FOR LARGER FOOTERS. 10 ALL NEW PERIMETER FOOTER POURED WITH A SLAB SHALL MEET THE FOLLOWING CONDITIONS: A PERIMETER FOOTER AND THE SLAB SHALL BE MONOLITHICALLY POURED, B ALL REQUIREMENTS OF ITEMS 8 AND 9 ABOVE. 11 ALUMINUM IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PROTECTED WITH AN ALKALI RESISTANT COATING. 12 THIS DRAWING COVERS ONLY THE ITEMS LISTED IN THE TITLE BOX. ANY OTHER TASK, SUCH AS ELECTRICAL, PLUMBING, ETC, SHALL BE BY OTHERS AND SHALL BE COVERED BY A SEPARATE DESIGN DOCUMENT. File COPY THIS DRAWING IS ONLY ACCEPTABLE FOR BUILDING PERMITS & ONLY WHEN IT HAS THE ENGINEER OF RECORD'S RAISED SEAL. COPIES ARE NOT DEEMED VALID. THIS DOCUMENT IS THE PROPERTY OF R. A. DUNLEA, P.E. AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF R. A. DUNLEA. R. A DUNLEA, P.E. 1513 CERVANTES PLACE THE VILLAGES, FLORIDA 32159 (772) 285-6444, (352) 750-6207 bobdunlea(a)centurviink.net FLORIDA P.E. Lic. No. 42835 WHO# • • %•(i�-T *� NO. ?D� :• S A OF " •: ��� 10'-6" 3' MODULAR HOME SITE SPECIFIC DRAWING I 9'-3" I 1 1 8'-6" . LEFT SIDE ELEVATION VIEW KNEE BRACE DETAIL rypg" mg,a ��� 24 fdak� n$�sk� h & 'x' z¢ "a r w �, a :r^`dk- ` �. « •,.z....- _. ..,... :, „F� ': +� r.t-..v. .ems.. «w� ■ <-COLUMN PER TABLE CHANNEL U TOTAL FO 2x3x0.070, BACK END MITERED W/ 1/8" U-CLIP, �IClf 6 # z s (6) #12 SMS INTO COLUMN / CARRY BEAM, (3) #12 24" �� SMS INTO EACH SIDE OF KNEE BRACE (TYP.) t ■ 1k ` CHANNEL NOTE: KNEE BRACES (KB) SHALL BE 2x3XO.O7 MEMBERS AND SHALL BE 2'-10" LONG AND EACH END SHALL BE CUT ON A 450 ANGLE. THIS WILL ALLOW FOR EACH END OF THE.KNEE BRACE TO BE 2'-0" FROM THE CORNER. NOTE: THE KNEE BRACES (KB) WILL BE ATTACHED TO THE COLUMNS AND CARRIER BEAMS USING A 2" x 2.25" x 2" x 0:125" THICK CHANNEL AS SEEN ABOVE. THERE WILL BE SIX (6) #12 SMS BETWEEN THE COLUMN AND THE CHANNEL AND BETWEEN THE CARRIER BEAM AND THE CHANNEL AND BETWEEN THE BRACE AND THE CHANNEL, 3 ON EACH SIDE, AT EACH END OF THE KNEE BRACE. A TOTAL OF TWENTY-FOUR (24) SCREWS FOR EACH KNEE BRACE. TWO (2) 318" BOLTS CAN BE SUBSTITUTED FOR EACH SIX SCREW CONNECTION. . 5" 8'-6" E X I S T I N G S H E D I 27'-0" I PLAN VIEW 3" -1 LB. POLY ROOF w/ 0.024" SKIN <-KB KB-> <-KB KB-> <-KB KB-> I • OPEN • OPEN • OPEN • 1 i I I r iP 7. w. r A a a. `-.�. �>� �, EXIS77NG N,QIUIINAL SLAB {E�� t Mr �.R''.� ��=�'x` „fm;..�e. tea.. � ca I I I 13" 8'-4" 13" 8'-4" 13" 8'-4" I3"I _ FRONT ELEVATION VIEW POLY ROOF CARPORT DWG. # RVC-2017-106, REV. 0 October 7, 2017 SHEET 2 OF 3 SITE DESIGN DRAWING HEIGHT 8'-6". 150 MPH, EXP. 'C' R V CONSTRUCTION 3318 COLUMBRINA CIRCLE PORT ST. LUCIE, FL 34952 OFFICE (772) 380-8253 LICENSE # CRC 1330965 LOCATION: NAME: HANSEN RESIDENCE ADDRESS: 8215 E. BITTERBUSH LANE CITY/STATE: PORT ST. LUCIE, FL 34952 COUNTY: ST. LUCIE DRAWINGS NOT TO SCALE R. A DUNLEA, P.E. 1513 CERVANTES PLACE THE VILLAGES, FLORIDA 32159 (772) 285-6444, (352) 750-6207 bobdunleaCa7centurviink.net FLORIDA P.E. Lic. No. 42835 PUN ew�o°�`q,�1T H O/yY N ..• • • 7A OF L�«�° :CON.NV CT TO STRIJCTU•RE: ':-.•i:�>,'.;,`SEEGENERAL'NOatr=10%•ORdShlilAisGl� ^ .'i:AG &OLTiL Fi ENDSTn.z' SOUND NFURP FASGiJ� i5' r� t rapt Y 74 F�4FE1!}ED 70 -e�ri-I RA4=7FR`VIIITFI:(1=4ii�-3.`'�'•;'LAGTLW�CEN-� r-.OZ4 C40NCREEIE OR FILED Y4'X1%4' EMBED TAPCON @ 2•' : & 414' FROM' �= ENDS BAL @ ie'� 1 MAX. O.C.* ROB PA-INEEL�O i�i FRONT ELEV ON EA-IiC1JVT _Ord NUCU5 , jAI(V iCOF T:=.� W F=AmAx SEALED TO ELUTE .5E 1 SJt V Al, i ��.'1!`�i�1 G _/EP-73 COLUMN 2' NOMINAL STRUCTURAL-/ELSTE FACIA MINIMUM EP-23 a14- AV SMS @ 7' O.C. (8) PER 4' PANEL TOP a/ TAPCONS, USE ' 8L 4'$' EMBED FROM BOTTOM. ACID (2) SMS 2' & 4" FROM EACH TAPGOPIS, 2Ys' h 43'i` FROM =_PIGS, ENCLOSURE END TOP EL BOTTOM. HEAVY 14 MAX O.C. TO HOLLOW BLOCK ADHESIVE CAULK TOP & BOTTOM CONTINUOUS ENCLOSDURi= -1-0 CONCRETE uECK AI C P- ORING D E T AIL *SEE GENERAL NOTE flO FOR ATION COLUIgN- PAR. TA'FSLES QA 3'x3'x3--%' ANGLE wlTti (7) -Yi' XI3/i EMBED. SEALED. SITE SPECIFIC TAPCUNs W/ SJe' MITI. WAsHt7L DIAMETER TG DRAWINGS/C.AL_C ULATIONS SLAB, 2)$° APART & 3' FROM SLAB EDGE & (fib 414 SMS TQ COLUMN, }4' FROM ANEC ED:_ ONE F CN SIDE OF COLIRHN ° v .O O " M(=NjJE)(IS�UNG CONCREiE SLAM & rDOTING: SE SITE SPECIFIC DETAl OR ADDI- ION b L FOOTING ENGFNEERING SHEET :EAVE BEAM CONNECTION @ WALL SEE GENERAL 110i. *10 FOR LIMIT TIO EPS POLY . _ (USED AS R�QURIED WHEN ROOF CONNECTING TO WALL) 3/q TFiRL6OLTTHR000H c 2°:3-A' ANGLE TO A00F, _ o o 3'Y.3°�e' ANGLE FASTENS] TO INSIDE & n BOTTOI•f OF CARRY BEAM W/ (2) Y+' Li• I BEAM P THRLFWLiS SIDE, (S) �i4 SMS BOl70M, iAI?LS�PA. 4tED FAS IENEDTO CBS WALL W/ (2) Vii xl/V EMBED TAPCONS OR TO WOOD (MIN 2), 'si?Eanc _rtyT�EGFdV BY OTHEL9) WITH (3)r14x%- x.IRUJS.IONS: fiir4EiVSiO(i5 �+1? i DESIGN r T11P. J 7,IR�tNSIlrliM.s2¢�R':77]. %JSE. T I4ti T ',:E34Cryc5pJNC- %,VILE 2 X 3 3E: �E4q G9J'rZ' L7'+1Eh15 0(45 BOX •TriP(I;i FfC]�� AS �- Ci I:=tED ,.L SEAM y :FALL-E)fRU_.IOMS'T05E . 2 X 3 smAP S Ll --PE • L td i.rj'3'l OwN. TOP IiYP BGTfOI) SEE TABLE --BMW �tL 0 2XVARIES LAP BE''Ali r` aE;um -cap ISIOE1 n 1 sa 2X4 1 'LG4� I 3 2Y.a _34`. !.OSLI'1 z Zn^ 13„ I-05i au 2 _ 2X5 .ZiQ�A7e 5 rI 2X'-0 ,3190 L.oez'j LAG =P.. - TABLE .A I i Q'3 .12'Q.C.3ana 9p, I �OQ C 30 ac 30�'dP 130Cs T3° . ANr7 L414 9�3 150 C s124° SMS L . / W. TOP -A 3�OM r�-� GLrCk—: ° `NL ='d1AL ROOF LOAD LOAD (OPT-) ° EARRY BEAM PEA'rABL3q OR OPTION 1: USE.'.," LAG BOLTS SEALED -SITE SPECIFIC W/ 1' NUM. WASHER DIAMETER,. DRAwINGQCALCULAlIGNS 1° MIN. LONGS¢ THAN P}1NL3 BOTH OPTIONS: (2) %'THRUBOLTS, T QCXT1E55 SP.4® PER LAG CARRY BEAM TQ OOLUMN SPACING TABLE TMs OEf_4-L a Q a o NOTCH -COLUMN I14 C$ITFR TO FIT OPTION 2: V4 THR.UBOLTS TO 0 CARRY BEAM SNUG ROOF, 4" FROM ENDS R 17- �j H OPTIONSM 3na'�%' ,4NGL`, (5) O.C. TCI 2'x2-96' ANGLES : 14 SKIS EA L ES, cA SIDE OF COW MN (EIT HESC SIDE IF REQUIRE[) BY ' BUILDING OEM. COLUMN PER TASLES OR SEALED SIi SPECIFIC DRAwING/CALCULA—i3ONS ' mom SECTION. AT SIDE -O'F ROOF PANEL W LAGS, 4' FROM E UI 5 a 24' MAYL O.G, I- MIN LONGER THAN PANEL TkICOIESS TO SEaJRE ROOF SMS La'� TO G4-PnHAAY WALLS ONLY- CAULK ALL. SCR5W TrP, TOP a HFJ1Ds` j BO iOM "q E-ITE ROOF ° ° PANEL 3[rc 2 X 2 BOX ENO 11P mm. OR �. VALAI4Cti a Q 2°_2'�'a''AMGLE, 13) 114 SMS EA LE:G, EA SIDE OF BEAM cf SIbE _ rsEF iABLZ BEL Oi rj "r14- SPAS 0 =-wqS a. 24" O.C. MAX TOP ? �GT7OM - BEA1'�I SPLICE -OVER COLUMN (1)'/,' LAG 40LT'I^IY'tb. J,Cri CNW BEAM a19fs; (5] 41.4 SMS E k 1° MIN LM4GEP_ TI FRI!I' CDE OF PLATE PANE T }MKNESS 5• n°! FPM Ycr % ca�eY_aEalM — SIDE aFdntolr4'.::'� - auMN .ER'CAELZ-5. SECTION AT BEARING COLUMN - ELITE TYPE T GUTTER OPTIONAL USE V4' LAG BOLTS W/ 1" MIN. WASHER DIAMETER, 1" MIN. LONGER THAN PANEL THICKNESS SPACED 3x3 POST #14 SMS, 3 SMS PER SIDE (6 TOTAL) #12XY4" SMS @ 16" TYP. TOP & BOTTOM 0 0 0 0 0 O EPS POLY 0 0 0 o ROOF %/12 SLOPE ADAPTOR SHOWN BEAM PERTABLES . .--. �. -=Yyi'1'CIY.('AllEfiilNG E� :aL'�JBiit IJK4'USET UF.ASTF#Eix (•�° ; 3/ "') AT 8" O.O. FQft UP' FOR-COMPOSF-FE-`iOOFS: O 130 -MPFI )-'MND SPE6ED 910 x (i i-1/2' j �.k_i.S •Wl E,XPOSUR` "D"; o' O.e;. FOR 1-1/4-0 FEAJDER ,V�LASi LEAS ABOVE 1301IMPI i!;JVD UP 10 :@12�D.4,:/~L 7#= .11UQ MP.N WING SPEED PANEC i'rt10KA1�5 + 1"} - E�QSI]Rf ROOF GEARING -(SHOWN) -AND.24`-0;C. @ GAUU ALL EXPOSEDWR�EN �ION�F�R)RiG ELEI;lENT (5Il]E =HEADS: &-%P S 1ERS W fi FOR PAN ROOFS: PjEACH #Sx 1/z".L,ONG S_M-1 .:..::.. -::-:_.•`. _::....... .......:..:. P-ER-12'.PA4if L W13F4': . :r:.:..:..= - -ALt11,�iFI UW-PA14-- ASHER - - ROOFI?AI�iEL _ o SUPPORTMt BEA1V1 ROOFz:P.A- -EL' T-D BEANI.FASTEN'� ;EIETA � CONCRETE LDT38212-> (OR EQUAL) 1 NOTE: THE TAPCONS CAN.BE REPLACED WITH TWO (2) 1/2" WEDGE ANCHORS (REDCAP, HILTI, OR EQUAL) WITH 2-114" MINIMUM EMBEDDMENT. ALSO, IF BUCKET IS BEING ATTACHED TO WOOD USE THE 3/8" - 3" WOOD SCREWS, W/ 1-1/4" WASHERS, TO SECURE THE BUCKETS. WEDGE ANCHOR MUST BE EQUAL OR HIGHER STRENGTH. CONCRETE Nam: t" (MIN. EMB.=2-1/4") 3" x 3" BUCKET CONNU an POLY ROOF CARPORT DWG. # RVC-2017-106, REV. 0 October 7, 2017 SHEET 3 OF 3 POLY ROOF CONNECTIONS HEIGHT 8'-6", 150 MPH, EXP.-'C' R V CONSTRUCTION 3318 COLUMBRINA CIRCLE PORT ST. LUCIE, FL 34952 OFFICE (772) 380-8253 LICENSE # CRC 1330965 LOCATION: NAME: HANSEN RESIDENCE ADDRESS: 8215 E. BITTERBUSH LANE CITY/STATE: PORT ST. LUCIE, FL 34952 COUNTY: ST. LUCIE THIS "CIRCLED" CONNECTIONS ON THIS SHEET ARE BEING USED FOR THIS PROJECT. 1 2 3 4 5 6 7- 8 9 10 11 NOTE: DRAWINGS ARE NOT TO SCALE. R. A DUNLEA, P.E. 1513 CERVANTES PLACE THE VILLAGES, FLORIDA 32159 (772) 285-6444, (352) 750-6207 bobdunlea(d1centurVlink.net i FLORIDA P.E. Lic. No. 42835. .00.-NIATHO47S° * rN T �...•�- .� 7 � �• S A O .� kI O•o '••'2 P••; A: ��O�i.�ONAL Er.•�.