EVALUATION REPORT FLORIDA BUILDING CODE, V EDITION (2014)
Manufacturer: TAMKO BUILDING PRODUCTS, INC. Issued August 22, 2016
P.O. Box 1404
Joplin, MO 64802 RECE
IVED
(417) 624-6644
h#R://wviw.taMko.com
Quality Assurance: UL LLC (QUA9625) n C T 2 4 2017
SCOPE Permitting Department
Category:
Subcategory:
Code Sections:
Properties:
Roofing
Underlayments
cie County, FL
1507.2.3, 1507.2.4, 1507.2.8,1507.2.9.2, 1507.3.3, 1507.4.5.1, 1507A.5.2,1507.4.5.3,
1507.5.3, 1507.5.3.2, 1507.6.3, 1507.663.2, 1507.6.5, 1507.7.3, 1507.7.3.2, 1507.8.3,
1507.8.3.2, 1507.8.8, T1507.8, 1507.9.3, 1507.9.3.2. 1507.9.5, 1507.9.9
Physical properties
REFERENCES
THESE PLANS AND ALL PROPOSFn
WORK
ARE T TO ANY CORRECTIONS
Enti
Report No.
RE ED BY FIELD
St ECTDRS THAT
PRI Construction Materials Technologies (TST6049)
TAP-191-02-01REV
A ESSARYZ�gRDER TO
PRI Construction Materials Technologies (TST6049)
TAP-192-02-01
A 11 MTN ALL ARB01l:ABLE CODES.
PRI Construction Materials Technologies (TST6049)
TAP-193-02-01
ASTM D 1970 2009
PRI Construction Materials Technologies (TST6049)
TAP-214-02-01
ASTM D 4869 2005e01
PRI Construction Materials Technologies (TST6049)
TAP-215-02-01
ASTM D 226 2006
PRI Construction Materials Technologies (TST6049)
TAP-216-02-03
ASTM D 6380 2003(2009)
PRI Construction Materials Technologies (TST6049)
TAP-217-02-01 REV
ASTM D 6380 2003(2009)
PRI Construction Materials Technologies (TST6049)
TAP-218-02-01
ASTM D 226 2006
PRI Construction Materials Technologies (TST6049)
TAP-219-02-01
ASTM D 226 20.06
PRI Construction Materials Technologies (TST6049)
TAP-220-02-01
ASTM D 6380 2003(2009)
PRI Construction Materials Technologies (TST6049)
TAP-222-02-01
ASTM D 4869 2005e01
PRI Construction Materials Technologies (TST6049)
TAP-319-02-01.1
ACC 188 2012
UL LLC (TST9628)
13CA12269
CpNCG9,A2TM D 226 2006
FASTENERS
ARET aRA
pO
PRODUCT DESCRIPTION AND APPLICATION.
Cnkrp. NSI l7-V�nAEyME>Y;
... Iw1,/ ��tt��++-nn,',,,�,,,, i nC
TAMKOO ASTM Slate ASTM D 6380, Class M, Type 11 undedgyment constructed from org�71mm saturated
Surfaced Roll Roofing with asphalt and. coated on both sides with asphalt and surfaced with granules.
Min. slope:
1710--ow Application:
ST. LUCIE COUNTY BT-ILD.EN PrvTcln%:
REVIEWED FOR C ICE
REVIL►VED B '
DATE
PLANS AtiD' R IT �' UST BE teJr84fcoverings:
OR NO INSPECTION WILL BE J111)E.
2:12
The underlayment shall be installed with minimum 2"
side laps and minimum 4" staggered end laps and in
accordance. with FRSA/TRI 07230 for tile
applications.
Attachment of asphalt shingle valleys and clay and
concrete the shall be permitted in accordance with
the FBC.
TBP14001.3 FL12328-R7 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK
TechnicalServices, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein. b CD �>�
.1
CREEK TAMKO, BUILDING PRODCUTS, INC.
TAMKO Underlayments
TECHNICAL SERVICES, LLC
TAMKOO ASTM Tile ASTM D 6380, Class M, Type I I undedayment constructed from an organic felt saturated
Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules.
Application:
The underlayment shall be installed with minimum 2"
side laps and minimum 4" staggered end laps and in
accordance with FRSA/TRI 07230 for tile
applications.
Allowable roof coverings:
Attachment of clay and concrete file 'shall be
permitted in accordance with the FBC.
TAMKOO Master
ASTM D 6380, Class S, Type IV
underlayment constructed from an organic felt saturated
Smooth
with asphalt then coated on both sides with asphalt and surfaced withr a fine mineral.
Application:
The underlayment shall be installed along the valley
in accordance with FBC requirements.
Allowable roof coverings:
Attachment of asphalt shingle valleys shall be
permitted in accordance with the FBC.
TAMKOO Moisture
Self -adhered, ASTM D 1970; fiberglass reinforced, modified bitumen sheet membrane
Guard Plus®
with a mineral surfacing and a removable release.film on the adhesive side.
Application:
The underlayment shall be attached by adhering
directly to the roof deck with minimum 3-1/2" side
laps and minimum 6" staggered end laps.
Min. application temperature:
400F.
Allowable roof coverings:
Attachment of asphalt shingles and mechanically
fastened concrete and clay file roofing shall be
permitted in accordance with the FBC.
TAMKO@ No. 15 ASTM
ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Organic Felt
Application:
The underlayment shall be installed with minimum 2"
side laps and minimum 4" end laps.
Allowable roof coverings:
Attachment of asphalt shingles, metal roofing, wood
shingles;. wood shakes, and roll roofing shall be
permitted in accordance with the FBC.
TAMKO® No. 15 UL
ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Organic Felt
Application:
The underlayment shall be installed with minimum 2"
side laps and minimum 4" end laps.
Allowable roof coverings:
Attachment of asphalt shingles, metal roofing, wood
shingles, wood shakes, and roll roofing shall be
permitted in accordance with the FBC.
TBP14001.3 FL12328-R7 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical.Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
TECHNICAL SERVICES, LLC
TAMKO® No. 30 ASTM ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
Application:. The underlayment shall be installed with minimum 2"
side laps and minimum 4" end laps.
Allowable roof.coverings: Attachment of asphalt shingles, metal .roofing, clay
and concrete tile, slate shingles, wood shingles,
wood shakes, and roll roofing shall be permitted in
accordance with the FBC.
TAMKOO No. 30 UL ASTM D 226; Type II underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Organic Felt
Application:
The underlayment shall be installed with minimum 2"
side laps and minimum 4" end laps.
Allowable roof coverings:
Attachment of asphalt shingles, metal roofing, clay
and concrete tile, slate shingles, wood shingles,
wood shakes, and. roll roofing shall be permitted in
accordance with the FBC'.
TAMKO® TW Metal and
Self -adhered, flexible, ASTM
D 1970, rubberized asphalt sheet membrane with a
Tile Underlayment
polymer film on the surface and
a removable release film on the adhesive side.
Application:
The underlayment shall be attached by adhering
directly to the roof deck with minimum 4" side laps
and minimum 6" staggered end laps.
Min. application temperature:
40'F
Allowable roof coverings:
Attachment of asphalt shingles, metal roofing, and
mechanically fastened clay and concrete tiles shall
be:permitted in accordance with the FBC.
TAMKO®TW
Self -adhered, flexible, ASTM
D 1970, rubberized asphalt sheet membrane with a
Underlayment
polymer film on the surface and
a removable release film on the adhesive side.
Application:
The underlayment shall be attached by adhering
directly to the roof deck with minimum 4" side laps
and minimum 6" staggered end laps.
Min. application temperature:
40°F
Allowable roof coverings:
Attachment of asphalt shingles and metal roofing
shall be permitted in accordance with the FBC.
TAMKO® TAM -FELT
Altemate to ASTM D 226, Type
I and Type II underlayment constructed from a non -
perforated organic felt that 'is saturated with asphalt. .
Application:
The underlayment shall be installed with minimum 2"
side laps and minimum 4" end laps.
Allowable roof coverings:
Attachment of asphalt shingles shall be permitted in
accordance with the FBC.
TBP14001.3 FL12328-R7 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any,product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
LIMITATIONS
TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
1) This evaluation report is not for use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Wind uplift resistance in not within scope of this evaluation.
4) Installation of the evaluated product shall comply with this report, the FBC; and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
5) Minimum application temperature shall be 50°F unless otherwise noted. Contact the manufacturer when
installing at temperatures below the minimum application temperature.
6) Deck substrates shall be clean, dry; and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
7) The. roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck
shall be installed in accordance with FBC requirements.
8) Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements.
9) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in successive courses installed up the deck in 'a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturer's application instructions.
10) The underlayment may be used as described in other current FBC product approval documents.
11) The underlayment shall not be installed over existing roof coverings.
12) Contactthe.mantfacturer regarding specific exposure limits for each underlayment.
13) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, a Edition (2014) as evidenced in the referenced documents submitted bythernamed manufacturer.
�.�`���F1Y
�����,Q . •v� C.E N SF ••,d'�'.
No 74021
STATE OF <U
Al
rrnlrnn►
CERTIFICATION OF INDEPENDENCE
2016.08.2
2 09:35:39
_041.0.01
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does nothave,.nor will it acquire, a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by company manufacturing or distributing products under this evaluation.
Zachary" R. priest, P.E. does nothave,:nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does nothave, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
END OF REPORT
TBP14001.3 FL.12328-R7 Page 4 of 4
This evaluation report is:provided for State of Florida product approval under Rule 61G20-3. Thet manufacturer shall notify CREEK
Technical. Services, LLC of any product changes or quality assurance changes throughout -the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.